This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Рели

Рели
Показать:
Сортировка:
  • SandSet-1000 is designed for sludge and sand detection in separators, basins and tanks
  • Easy to install, does not need calibration
  • Reliable long-term se in harshest conditions
  • Acoustic and visual alarms
  • 2 switch outputs or output to LabkoNet remote monitoring system
  • Ultrasonic sensor SET/S, 5 meter cable
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz
  • Relay output
  • Smoke sensitivity complies with EN 54-7:2000+ A1:2002
  • Digital signal processing
  • Very low current consumption
  • Excellent long-term stability
  • LED indication
  • Supply: 10...30 VDC
  • Warranty: 3 years

RSP-E25-... is a Class I+II SPD for surge and lightning protection of low-voltage power supply systems, especially in high-risk exposure areas or building entrances in LPZ 0-2 (IEC 62305-4), protecting against damage caused by direct or nearby lightning strikes; suitable for use in main distribution boards.

  • IEC / EN / VDE category: Class I+II / Type 1+2 / B+C
  • Application: main distribution boards (MB)
  • Power networks: TT, TN-S, TN-C
  • Protection modes: L-N, N-PE
  • Protective elements: MOV, MOV+GDT
  • Enclosure: modular (replaceable module)
  • Mechanical status indicator: green/red flag
  • Compliant with standards: IEC/EN 61643-11:2011, IEC 60364-4-53, IEC 62305, CE, RoHS
  • Temperature range: from +20...+110 °C iki +40...+300 °C
  • Output signal: 1 floating change-over contact
  • Process temperature: +20...+300 °C
  • Approval: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, RMRS, EN60730-1/ EN60730-2-9: Typ 2.B.H
  • Protection class: IP65
  • Input: RTD: Pt100 (2-wire) / TC: K
  • Output: relay (NC/NO)
  • Configuration: via HART (switching point, hysteresis, switching delay, damping), with magnet (switching point)
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC
  • Operates as a temperature switch (thermostat), transducer, data logger
  • Accumulated temperature data is read using a mobile phone with NFC interface
  • Parametrization via NFC interface
  • Display and electrical connection are independently rotatable 335°/343°
  • Temperature measurement range: -50...+150 °C
  • Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
  • Switch output: 2 x PNP
  • Sensor: Pt1000 A
  • Data logger memory: 3518 measurement points
  • Measurement interval: 0,1...999,9 s
  • Operating temperature: -25...+85 °C
  • Supply: 15...30 VDC

Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.

  • Flow and temperature sensor for liquids in pipes
  • Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
  • Flow measurement range: 1...150 cm/s (water)
  • Temperature measurement switching points: 15, 30, 45, 60, 75 °C
  • Flow rate measurement is shown in a bar graph by five green LEDs
  • Settings provided by magnetic pen
  • Stainless steel case
  • Supply: 12...34 VDC
  • Ambient temperature: -20...+80 °C
  • Protection class: IP67 / IP68

They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.

  • Three-phase power controller (phase angle load control)
  • Control input: DC voltage 0...10 V DC or current 4...20 mA
  • SCR output (thyristors)
  • Load current 25...80 A
  • Max. load voltage 530 V AC (three-phase)
  • Dielectric strength 4 000 Vrms (opto-isolation)
  • MOV protection (built-in varistor)
  • Mounting on heatsinks
  • Recognitions, certifications, directives: RoHS, REACH, CE, EAC

The RE12S Universal PID Controller is an advanced and versatile device designed for precise process control in various industrial applications. With adaptive, auto, and self-tuning PID as well as ON-OFF control capabilities, the RE12S ensures optimal performance in maintaining desired setpoints. It features a dual LED display, capacitive touch keypad, and supports up to 128-step profiling for complex control requirements. The unit's robust communication options, including RS485 MODBUS RTU, allow seamless integration into existing systems, enhancing both functionality and connectivity.

  • Control algorithm: Adaptive, Auto, Self-tune PID, ON-OFF
  • Input: Thermocouple (J, K, T, R, S, C, E, B, N, L, U, W, Platinel II), RTD (PT100), - 5…56mV, 0…10V, 0…20mA
  • Alarm Outputs 3x: Multiple settings including deviation high/low, absolute high/low, band, sensor break
  • Profile Controller: Up to 128 steps
  • Special Modes: Heat-Cool PID, Auto/Manual, Single point ramp/soak, Soft start
  • Communication: RS485 MODBUS RTU
  • Power Supply: 90...270 VAC / DC (50/60Hz)
  • Display: 4+4 digit, 7 segments
  • Ambient temperature / humidity: 0…+50 °C / < 85%RH
  • Dimensions: 52 x 52 x 76 mm
  • RTKSA series thermostat have cooling or / and heating functions
  • Temperature control range: -10, 0, 20, 30, …50, 110, 120, 150 °C
  • Two-way switching contact
  • Number of outputs: up to 4
  • Number of control ranges: up to 2
  • Sensor element: capillary tube
  • Capillary tube length: up to 12 m
  • Maximum switching voltage: 230 V AC 50 / 60 Hz, 230 V DC
  • Maximum switching current: NC: 16 (2.5) A; NO: 6.3 (2.5) A, 0,25 ADC
  • Minimum switching voltage: 24 V AC / 50 Hz, 24 V DC
  • Universal mounting
  • Ambient temperature for head: up to 80 °C
  • Protection class: up to IP65
  • Safety and EMC: in accordance DIN EN 60730
  • Pressure range: from -0,9...1,5 to 4...40 bar
  • Output signal: 1 Floating change-over contact (SPDT)
  • Process temperature: -40...+150 °C
  • Process connection: G1/4" f, G1/2" m, 1/4" NPT f
  • Protection class: IP65
Vertical stainless steel float level sensor LB-3. Technical specificationsHousing: top;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..
Vertical stainless steel float level sensor LB-4. Technical specificationsHousing: side, 90° angle;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..

The LP10-V monitors the AC voltage of the system / equipment and protects it against overvoltage, undervoltage and phase failure problems. It also indicates faults with LED indicators.

Applications: Motor protection, Server rooms, Control system

Features:

  • Compact size 17.5 mm
  • True RMS measurement
  • Under voltage protection
  • Over voltage protection
  • Phase unbalance protection
  • Phase failure protection
  • Phase incorrect sequence protection
  • Neutral failure protection
  • Adjustable Nominal voltage, Trip point, Trip time delay
  • Onsite selection of VLL / VLN value-based tripping
  • Self-powered
  • 1CO, 1CO+1CO relay configuration
  • LED indication for faults
  • Disabling of Over & Under Voltage fault on site is possible

The TSF400-0 is a compact water-leak detector designed for early detection of water presence on floors, trays, or inside equipment enclosures. It operates from a wide 4.5–26 VDC supply and provides an N-channel open-drain output for direct connection to PLCs, controllers, alarm modules, or building-automation systems.

Applications:

  • Leak detection in server rooms, UPS rooms and telecom shelters
  • HVAC drip trays, cooling/condensation lines
  • Under-floor and raised-floor monitoring
  • Domestic and commercial flood-alert systems

Specifications:

  • Operating temperature range: 0...50 °C
  • Ingress protection: IP65
  • Cable length: 3 m

Sensor SKU: 5905309600072 (IP30)

Sensor SKU: 5905309600607 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.

  • Wireless 4…20 mA / 0…10 V analog signal sensor interface, data logger, NB-IoT measures analog readings and can send data over NB-IoT
  • Device can be equipped with up to four analog interfaces / transducers (2 x 4…20 mA and 2 x 0…10 V)
  • Transducer can be powered* either from the device’s battery or by an external power source
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -35…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection (IP67 on request)

Sensor SKU: 5905309601376 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Device monitor state of relays or reed switches (1 channel for input)
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327714 (IP30)

Sensor SKU: 5905309600713 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Device monitor state of relays or reed switches (1 channel for input)
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Sensor's configuration can be changed remotely from the cloud or with a mobile application over Bluetooth Low Energy
  • Operating temperature: -35…+70 °C
  • Case IP30 protection (IP67 on request)
  • Device G2-DC designed to monitor state of relays or reed switches
  • Input: 2 dry contacts
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: C, T, or S (selectable on order)
    • Standard T1-mode, transmission 90 seconds, encryption ON
  • Transmission interval: configurable 60 s…1 h (selectable on order)
  • Every message contains the contact status and battery level
  • The message is sent as soon as a dry contact switch is detected
  • AES-128 encryption mode 5, profile A (can be ordered with custom configuration)
  • Power supply: 3.6V Li-SOCl2, AA battery
    • Warning about low battery
    • Up to 14 years battery lifetime, depending on configuration and operating temperature
  • Operating temperature: -30…+85 °C (Recommended: +5…50 °C) (none condensing)
  • Water leakage detector G2-LD detects leakage with active 1 meter cable
  • Up to 2 leakage cables mountable
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: configurable C, T, or S (configurable)
    • AES-128 encryption mode 5, profile A
  • Transmission interval: configurable 60 s…1 hour
  • Operating temperature: -30…+85 °C (recommended +5…+50 °C) (None condensing)
  • Warnings about low battery, case opened or removed from wall (opt.), leakage detected (red LED)
  • Power supply: ER14505 3.6 V Li-SOCI2 battery
    • Battery lifetime up to 14 years, depends on configuration and operating temperature

Sensor SKU: 5905309601369 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Sensor detects change of state (open / close) with reed switch
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327691 (IP30) – plastic magnetic detector

Sensor SKU: 5906660327707 (IP30) – metal magnetic detector

Sensor SKU: 5905309600768 (IP67) – metal magnetic detector

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Sensor detects change of state (open / close) with reed switch
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection (IP67 on request)

Sensor SKU: 5905309601352 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Sensor detects the presence of conductive liquid (e.g. water) at any point along the entire length of the cable
  • Probe maximum working temperature: 70 °C
  • Probe length: 3 m (different probe length on request)
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327684 (IP30)

Sensor SKU: 5905309600348 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Sensor detects the presence of conductive liquid (e.g. water) at any point along the entire length of the cable
  • Probe maximum working temperature: 70 °C
  • Probe length: 3 m (different probe length on request)
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection (IP67 on request)

Sensor SKU: 5905309601345 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Detection of the presence of a conductive fluid (e.g. water) on the level at which the probe is mounted
  • Probe length: 3 m
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327677 (IP30)

Sensor SKU: 5905309600645 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Detection of the presence of a conductive fluid (e.g. water) on the level at which the probe is mounted
  • Probe length: 3 m
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection (IP67 on request)
Vertical float level sensor LV for fluid tank monitoring, automation, testing, measuring and control devices. Technical specifications Switching power ≤ 10 W Switching voltage ≤ 200 V Switching current ≤ 0,5 A Ambient temperature -20...90 ºC Casing material PP (polypropylene) for water and weak acid devices  LV datasheet [LT] ..

Level sensor with elimination of rests or foam on the electrode:

  • Designed for reliable limit level sensing of wide-range of fluids (electrically conductive or non-conductive), mashed and paste-like materials
  • Resistant to adhesion of viscous and sticky media (ketchup, yoghurt, spreads, syrups, creams, pastes, cleaning agents, alkalis, etc.)
  • Replacement of vibration level sensors
  • Unique function for media recognition “Medium window” (sensor is sensitive only to set medium and does not react to substances with a lower or higher permittivity)
  • Direct mounting into tanks, vessels, sumps, pipes or funnels and containers
  • Settings by the magic pen (included)
Horizontal float level sensor LH, designed for fluid tank monitoring, usage in automation, testing, measuring and control devices.  Switching power ≤ 10 W Switching voltage ≤ 200 V AC/DC Switching current ≤ 0,5 A AC/DC Ambient temperature -20...90 ºC  Casing material PP (polypropylene) for water and weak acid devices More information PDF [LT] ..
  • SF6 gas monitor for high voltage switchgear
  • Four versions: 1 / 2 / 3 / 4 stages (8716 / 8726/ 8736 / 8746)
  • Measurement range: 0...1.1 MPa
  • Output signal: floating change-over contact (SPDT)
  • Switch point: factory calibrated
  • Media temperature: -40...+80 °C
  • Protection class: IP67
  • Independent, galvanically separated circuits
  • SF6 gas density monitor for high voltage switchgear
  • Three versions: 1 / 2 / 3 stages (8781 / 8782 / 8783)
  • Measurement range: 0...1,1 MPa (mechanical), 0...0,85 MPa (electronic)
  • Output signal: floating change-over contact (SPDT) / 6.5...20 mA current loop
  • Switch point: factory calibrated
  • Media temperature: -40...+80 °C
  • Ambient temperature: -40...+80 °C
  • Protection class: IP65
  • Designed for the remote monitoring of measurements in industrial, domestic and environmental maintenance applications
  • Typical applications include oil separator alarms, tank surface level measurements, monitoring pumping stations and real estate, and surface and groundwater measurements
  • The device sends alarms and measurement results as text messages either directly to GSM phone or to the LabkoNet server
  • Settings can be easily modified with a GSM phone
  • Analog inputs: 4 units 4...20 mA (passive or active)
  • Digital inputs: 4 units
  • Relay outputs: 2 units
  • Communication: SMS, GPRS
  • Operating temperature: -20...+50 °C
  • Supply: 230 VAC / 12 VDC battery
  • Protection class: IP65
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from  -0,6...3,4 to 4...40 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C / -40...+125 °C
  • Ambient temperature: -25...+125 °C / -40...+125 °C
  • Protection: IP65
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from 1...10 to 40...400 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C
  • Ambient temperature: -25...+85 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: membrana
  • Measured pressure from 1...10 to 10...100 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: 0...+80 °C
  • Ambient temperature: 0...+80 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
  • Compact thermostat for shipbuilding
  • ISP version – with capillary tube, ISPT version – without capillary tube
  • Measured temperature from +5...95 °C to +20...150 °C
  • Switching differential: not adjustable
  • Output signal: floating change-over contact
  • Ambient temperature: -30...+70 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H

Single-phase commutator – controller RP7. The device can be used or circuit commutations. Can be used for resistive and inductive loads and single-phase motor speed control. Possible control with standard analog signal.

 

Other functions:

  • Load current limiting
  • Soft start
  • Isolated inputs
  • Load current control
  • Fuse failure detection
  • Overload indication

Single-phase controller – commutator RP1. The device can be used or circuit commutations in heat element devices. Can be used for resistive and inductive loads. Possible control: pulse or standard (analog signal).

 

Other functions:

  • Load current limiting
  • Soft start
  • Initial load power setting
  • Control with an external signal
  • Load current control
  • Fuse failure detection
  • Overload indication
  • Master/slave output
  • Switch output
  • Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
  • Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Multipoint float level switches LJ-VDT for fluid level measurement and control
  • Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Deactivation of the control system in the case of excessive temperature, or in the case of sensor error
  • Universal input for thermocouples and resistance thermometers
  • Relay output for disconnecting the temperature control system
  • Supply: 230 VAC
  • Operating temperature: 0...50 °C
  • Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC 
  • Float level switches AUREGIS LJ-V with an extension for level control
  • Operating temperature: -30...+130°C
  • Protection class: IP65 

DPC 8380 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

DPS 8381 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

  • Range: 0...2,5 iki 0...600 bar / 0...30 iki 0...7500 psi
  • Sensor type: Thick film on steel
  • Accuracy:  ±0,5 %
  • Output (chosen): 4...20 mA / 0...5 VDC / 0...10 VDC / 1...6 VDC
  • Switching outputs: 2 x PNP
  • Shown measuring units: bar, psi, MPa, kPa, m WC, mm WC
  • Ambient temperature: -25...+85 °C
  • Media temperature: -25...+85 °C
  • Protection class: IP65
  • Process connection: G1/4" m, R1/4" m, 1/4"NPT m, 1/2"NPT m
  • Data logger memory: 3518 points

Humidity and temperature regulator AR247 is designed for temperature and humidity control. The device is made with either integrated or cable-connected sensor. Protection class is IP65. Optionally can be ordered: RS-232 or RS-485 ports, analog output 0/4...20 mA or 0...10 VDC (for control or signal transmission).

Differential pressure switch EXPD 920/924/932. Technical specifications Range -1...18 bar Accuracy  ±2 % Output Switch Switching voltage, current 250 VDC, 0,25 A 250 VAC, 5 A 30 VDC, 5 A Ambient temperature -30...+65 °C Process temperature < 150 °C  Protection class IP65 Process connection ..
  • Used for controlling pumps in traditional boosting systems, with expansion tank
  • Possible ranges: 1,5...6 bar, 4...10 bar (programmable)
  • 1- or 3-phase
  • Mounting on pipe
  • Operating temperature: 0...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP44
Loading...