This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Реле уровня

Реле уровня
Показать:
Сортировка:
  • The Si-83 tank pump is perfect for residential A/C (up to 20 kW) and heating units (up to 40 kW)
  • Max discharge head: 5,4 m
  • Max pressure: 5,7 m
  • Tank volume: 2 L
  • Automatic turn on specific level in tank
  • Overdraft level safety switch
  • Stainless steel motor shaft
  • Protection class: IP44
  • Max condensate temperature: 55 °C
  • Max condensate acidity: pH > 2,5 (Gas condensing boilers)
  • Quick installation with mobile app
  • SET-1000 + SET/OSK2 is designed for oil detection on water surface
  • Can be used in tanks where water level is alternating
  • Control device SET-1000 is a one-channel level switch
  • SET/OSK2 sensor detects more than 15 mm width hydrocarbon layer on water surface
  • Polypropylene floats
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz
  • The versatile Si 2052 is suitable for replacement of some market standards drain pumps used in cassette type air-conditioning units up to 20 kW
  • Max discharge head: 0,9 m (flow rate = 24 l/h)
  • The single level detection unit can be used as a safety contact (NC 50 VA resistive – 250 V) to cut off automatically the air conditioning system compressor or solenoid valve
  • The centrifugal technology inside this pump is specifically designed for removing condensates continuously, in any kind of environment, with a very low sound level (≤ 30 dBA)
  • Protection class: IPX4
  • Operating conditions: 100 % - continuous duty
  • Lokaset 20 is designed for high wastewater level detection in septic tanks
  • Easy to install, does not need calibration
  • Switch output
  • Visual and acoustic alarms
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz

Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.

  • Material of float: stainless steel AISI 316 SS
  • Max. temperature: -30...+105 °C
  • Switch rating: 50 VA
  • Switching voltage: 230 AC / DC
  • GA-1 is designed for grease detection in separators, basins and tanks
  • Easy to install, does not need calibration
  • Switch output
  • Remote monitoring capability
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • GA-2 is designed for grease detection in separators, basins and tanks
  • Two sensors – one is for grease detection, other – for blockage control
  • Easy to install, does not need calibration
  • 2 switch outputs
  • Remote monitoring capability
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz

High frequency limit level sensors with elimination of deposits and foam on the electrode for vertical mounting

  • High frequency limit level sensors with elimination of deposits and foam on the electrode for vertical mounting,
  • Resistant to adhesion of viscous and sticky media (ketchup, yoghurt, spreads, syrups, creams, pastes, cleaning agents, alkalis, etc.)
  • Unique material type resolution function "Medium window" (the sensor is sensitive only to the set medium and does not react to substances with lower and higher permittivity)
  • Can replace vibration level sensors
  • Universal design for all types of liquids (electrically conductive or non-conductive)
  • For vertical mounting
  • Adjustment with a magnetic pen before installation
  • High level detection
  • Oil on water surface detection
  • Designed for usage in separators, basins and tanks
  • Easy to install, does not need calibration
  • Reliable long-term se in harshest conditions
  • Acoustic and visual alarms
  • 2 switch outputs
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
Horizontal stainless steel float level sensor LB-1. Technical specificationsHousing: side;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..
Horizontal stainless steel float level sensor LB-2. Technical specificationsHousing: side;Material of float: stainless steel AISI 316 SS;Process connection:  1/2 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..

idOil sensors are an integral part of the idOil oil separator alarm system and they are to be used with the idOil control units. All idOil sensors are digital and polarity free. Standard cable length is 5 m.

 

  • idOil-LIQ high liquid level sensor|
    Indicates when the liquid level in the oil separator rises excessively e.g. in an outlet blockage situation.
  • idOil-OIL oil sensor
    Detects oil and indicates when the separator’s oil storage is full.
  • idOil-SLU sludge sensor
    Monitors the sludge layer in the oil separator and indicates when the sludge layer has reached its maximum level.

“idOil®” is an alarm system intended for monitoring liquid levels particularly in oil and sand separators. The system consists of the idOil control unit and the idOil sensors installed in the separator. The sensor cables can be extended with a cable connector or connection box. One to three digital idOil sensors of the same or different type can be connected to the control unit. The sensors can be used to monitor the following:

  • High liquid level (idOil-LIQ high liquid level sensor)
  • Oil layer detection (idOil-OIL oil sensor is for class IIA explosive liquids and idOil-OIL-Soil sensor is for class IIB explosive liquids)
  • Sludge layer detection (idOil-SLU sludge sensor)

“idOil®” is an alarm system intended for monitoring liquid levels particularly in oil and sand separators. The system consists of the idOil control unit and the idOil sensors installed in the separator. The sensor cables can be extended with a cable connector or connection box. One to three digital idOil sensors of the same or different type can be connected to the control unit. The sensors can be used to monitor the following:

  • High liquid level (idOil-LIQ high liquid level sensor)
  • Oil layer detection (idOil-OIL oil sensor is for class IIA explosive liquids and idOil-OIL-Soil sensor is for class IIB explosive liquids)
  • Sludge layer detection (idOil-SLU sludge sensor)
  • Adjustable start time delay: 0...16 s
  • Operating resistance: 0...100 kΩ
  • Mounting on DIN rail
  • Operating temperature: -10...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP20
  • Three versions by sensitivity: NS (standard), AS (high), SR (adjustable)
  • Operating resistance: 5,6 kΩ (NS) 70 kΩ (AS) 0...100 kΩ (SR)
  • Mounting on DIN rail
  • Operating temperature: -10...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP20
  • Input: standard 4...20 mA signal or capacitive Labkotec 3W probe
  • Current output: 0/4...20 mA
  • Switch outputs: 2 units
  • LCD display
  • Programmable using buttons
  • ATEX certified
  • Wall-mounted, IP65
  • Supply: 230 VAC, 50/60 Hz
  • High level detection
  • Oil on water surface detection
  • Sludge under water detection
  • Designed for usage in separators, basins and tanks
  • Version with GSM module available – for alarms and service reminders
  • Acoustic and visual alarms
  • 2 switch outputs
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • For liquids limit level sensing on non-conductive (glass or plastic) gauge-pipes, tubes and tank walls
  • Output: switch or PNP
  • Sensitivity setting by means of magnetic pen
  • LED indication
  • Prismatic or planar electrode
  • Versions with a fixed cable or a connector
  • Supply: 6...30 VDC
  • Operating temperature: -20...+80 °C
  • Protection class: IP67
  • Output: switch
  • Application: level sensing for solids
  • Supply: 24 VDC / 220 VAC
  • Sensitivity setting: 3 positions
  • Rotation speed: 1 per minute
  • Operating temperature: -20...+70 °C
  • Operating pressure: up to 0,8 bar
  • Material: body – plastic, other component – stainless steel
  • Protection class: IP65
  • Weight: 1 kg

The AUREGIS LJ-VD4M12 multi-zone floating, stainless steel level relay with standard M12 connector is designed for liquid level measurement and regulation.

  • Connection connector: M12 (4 / 8 pins)
  • Floats and float holders are customizable (on request)
  • Connection thread: G3/4" or larger (on request)
  • Switching power: 25 VA
  • Switching voltage: 24 V AC/DC
  • Process part operating temperature: -30...+105 °C
  • Process part: Stainless steel AISI316L
  • Protection class: IP65
  • OilSET-1000 is designed for oil detection in separators, basins and tanks
  • Easy to install, does not need calibration
  • 2 switch outputs
  • Ultrasonic sensor SET/S, 5 meter cable
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz
  • Output relay: SPDT / 3A / 250VAC
  • Application: level sensing for solids and powder
  • Speed: 1 RPM
  • Supply: 24 VDC or 220 VAC
  • Operating temperature: - 10...+ 70 °C
  • Operating pressure: - 0,6...+ 0,6 bar
  • Protection class: IP66
  • Sludge and sand detection
  • Oil on water surface detection
  • Designed for usage in separators, basins and tanks
  • Easy to install, does not need calibration
  • Reliable long-term se in harshest conditions
  • Acoustic and visual alarms
  • 2 switch outputs
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • SandSet-1000 is designed for sludge and sand detection in separators, basins and tanks
  • Easy to install, does not need calibration
  • Reliable long-term se in harshest conditions
  • Acoustic and visual alarms
  • 2 switch outputs or output to LabkoNet remote monitoring system
  • Ultrasonic sensor SET/S, 5 meter cable
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz
  • Separator alarm system for applications where mains supply is not available
  • ATEX certified
  • Alarms:
    • high level detection
    • oil on water surface detection
    • sludge under water detection
  • SolarSet Beacon consists of:
    • housing containing and panel
    • battery
    • charger controller
    • flashing beacon for alarm
    • sludge and oil level sensor system LevelSet S
  • Separator alarm system for applications where mains supply is not available
  • ATEX certified
  • Alarms:

• high level detection

• oil on water surface detection

• sludge under water detection

  • SolarSet Beacon consists of:

• housing containing and panel

• battery

• charger controller

• GSM/GPRS modem

• flashing beacon for alarm

• sludge and oil level sensor system LevelSet S

  • Separator alarm system for applications where mains supply is not available
  • ATEX certified
  • Alarms:
    • high level detection
    • oil on water surface detection
    • sludge under water detection
  • SolarSet Beacon consists of:
    • housing containing and panel
    • battery
    • charger controller
    • GSM/GPRS modem
    • sludge and oil level sensor system LevelSet S
  • Up to 10 / 15 m level measurement with automatic temperature compensation
  • Calculation of filling in the tank or flow in open channels
  • Galvanically isolated 0/4...20 mA analog output
  • Digital RS-485 Modbus RTU interface
  • 2 alarm outputs
  • Internal data and setup memory
  • Two 32-points individual characteristics (for recalculation)
  • LCD screen
  • Housing protection grade: IP66
  • Sensor protection grade: IP66 / IP 68
  • Supply: 12...25...40 VDC
  • Operating temperature: -20...23...55 °C
Vertical stainless steel float level sensor LB-3. Technical specificationsHousing: top;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..
Vertical stainless steel float level sensor LB-4. Technical specificationsHousing: side, 90° angle;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..
Vertical float level sensor LV for fluid tank monitoring, automation, testing, measuring and control devices. Technical specifications Switching power ≤ 10 W Switching voltage ≤ 200 V Switching current ≤ 0,5 A Ambient temperature -20...90 ºC Casing material PP (polypropylene) for water and weak acid devices  LV datasheet [LT] ..

Level sensor with elimination of rests or foam on the electrode:

  • Designed for reliable limit level sensing of wide-range of fluids (electrically conductive or non-conductive), mashed and paste-like materials
  • Resistant to adhesion of viscous and sticky media (ketchup, yoghurt, spreads, syrups, creams, pastes, cleaning agents, alkalis, etc.)
  • Replacement of vibration level sensors
  • Unique function for media recognition “Medium window” (sensor is sensitive only to set medium and does not react to substances with a lower or higher permittivity)
  • Direct mounting into tanks, vessels, sumps, pipes or funnels and containers
  • Settings by the magic pen (included)
Horizontal float level sensor LH, designed for fluid tank monitoring, usage in automation, testing, measuring and control devices.  Switching power ≤ 10 W Switching voltage ≤ 200 V AC/DC Switching current ≤ 0,5 A AC/DC Ambient temperature -20...90 ºC  Casing material PP (polypropylene) for water and weak acid devices More information PDF [LT] ..
  • Designed for the remote monitoring of measurements in industrial, domestic and environmental maintenance applications
  • Typical applications include oil separator alarms, tank surface level measurements, monitoring pumping stations and real estate, and surface and groundwater measurements
  • The device sends alarms and measurement results as text messages either directly to GSM phone or to the LabkoNet server
  • Settings can be easily modified with a GSM phone
  • Analog inputs: 4 units 4...20 mA (passive or active)
  • Digital inputs: 4 units
  • Relay outputs: 2 units
  • Communication: SMS, GPRS
  • Operating temperature: -20...+50 °C
  • Supply: 230 VAC / 12 VDC battery
  • Protection class: IP65
  • Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
  • Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Multipoint float level switches LJ-VDT for fluid level measurement and control
  • Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC 
  • Float level switches AUREGIS LJ-V with an extension for level control
  • Operating temperature: -30...+130°C
  • Protection class: IP65 
  • System consists of alarm device SET-1000 and fixed level vibration sensor SET/V
  • For usage separators, basins and tanks
  • Alarm device SET-1000 is a single-channel level switch
  • When used with SET/V, SET-1000 alarms when set high level in tank is exceeded
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
  • Double water- and air-resistant sealant increases protection against infiltration even more
  • Weight: 1050 g; Buoy volume: 990 cm3; Maximum pressure: < 2 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached.
  • Weight: 163 g; Buoy volume: 280 cm3: Maximum pressure:< 1 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
  • Double water- and air-resistant sealant increases protection against infiltration even more
  • Weight: 250 g; Buoy volume: 430 cm3; Maximum pressure: < 1 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Boasts for great reliability and small size
  • Weight: 111 g; Buoy volume: 225 cm3; Maximum pressure: < 2 bar / < 5 bar
Loading...