- 1-Wire protocol ambient light sensor
- Light measurement range: 0...83000 lux
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
TSM400-1-TH is a digital temperature and humidity sensor with a 1-Wire interface. Suitable for monitoring air quality of server rooms, data centers, offices and stores.
- Temperature measurement range: -20…+60°C
- Accuracy (min): ± 0,4 °C (in -10…+60°C range)
- Accuracy (max): ± 0,6 °C (in -20…+60°C range)
- Resolution: 0,1 °C
- Relative humidity measurement range: 10 to 90% (non-condensing)
- Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
- Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
- Resolution: 0,1 %RH
- Excellent long-term stability
- The unique 64-Bit serial number for multi-sensors support
- Ingress protection: IP20
- Operating voltage range: 4,5…26 VDC
The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.
- 64 MEMS digital microphones for image of leaks
- Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
- Measuring distance: 3…15 m
- Integrated visual light camera
- The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
- Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
- Option for IO support through fieldbus coupler
- Integration: HTTP REST API, Modbus
- Operating temperature: -20…+50 °C
- Protection class: IP54
- Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
Ambient humidity and temperature logger TERMIOPLUS-S with external sensor is designed for logging of ambient humidity and temperature in its internal memory.
- Temperature range: -30...+70°C
- Temperature accuracy: In range -30...+70 °C: ± 0,3 °C
- Resolution: 0.1
- Humidity range: 0...100 % RH
- Humidity accuracy: ±2 %RH at 25 °C (30…70 %RH); ±3 %RH at 25 °C (10…90 %RH); ±4 %RH at 25 °C (0…100 %RH)
- Memory: 32000 (16000 temperature and 16000 humidity)
- USB interface for data download
- Logging interval: 15 s...10000 min
- Supply: 2xAA battery, 3.6 V
- Battery lifetime: 1 one year with 30 min. interval recording at +10 °C
- Size: 45 x 100 x 19 mm
Carbon dioxide (CO2) and temperature transmitter with a display CDT2000 Duct. The device is designed for measurement of air parameters in ventilation channels.
- CO2 range 400...2000 ppm
- Temperature range 0...50 °C
Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.
- Carbon dioxide (CO2) range: 400...2000 ppm
- Humidity range: 0...100 %
- Temperature range: 0...50 °C
Carbon dioxide transmitter CMT is designed for CO concentration measurement. The transmitter is used to control interior ventilation systems.
- CO range 0...300 ppm
- Measures carbon dioxide concentration in air
- Measurement range: 0...2000 ppm
- Operating temperature: -30...60 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- Measures carbon dioxide concentration in air
- Measurement range: 0...10000 ppm
- Operating temperature: -30...80 °C
- Cable length: 1 / 2 / 5 / 10 m
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- Measures carbon dioxide concentration in air
- Duct mount
- Measurement range: 0...2000 ppm
- Operating temperature: -30...60 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- Measures carbon dioxide concentration in air, temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: 0...2000 ppm, -30...+80 °C, 5...95 %RH
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s; CO2: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
- Measures carbon dioxide concentration in air, temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: 0...10000 ppm, -30...+105 °C, 5...95 %RH
- Temperature and humidity sensor cable length: 1 / 2 / 4 m
- Carbon dioxide concentration sensor cable length: 1 2 / 5 / 10 m
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s; CO2: 15 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
SM400-4-CPTH is a multi-sensor that supports MODBUS RTU protocol over the RS-485 interface. The sensor measures CO2 concentration, humidity, temperature and barometric pressure. Suitable for environmental quality monitoring, indoor air, smart ventilation systems, restaurants and breweries CO2 level and CO2 leakage control.
- Changeable bitrate and other communication parameters
- Non-volatile memory for all setting
- Temperature measurement range: -20 to 60°C
- Accuracy (min): ±0.4 °C (in -10 to +60°C range)
- Accuracy (max): ±0.6 °C (in -20 to +60°C range)
- Resolution: 0.1 °C
- Relative humidity measurement range: 10 to 90% (non-condensing) *
- Accuracy (min): ±3.0 %RH (in 20 to 80 %RH range)
- Accuracy (max): ±5.0 %RH (in 10 to 90 %RH range) *
- Resolution: 0.1 %RH
- CO2 measurements range: 400…5000 ppm
- Accuracy: ± (40 ppm + 5 %)
- Resolution: 1 ppm
- Calibration: Automatic, if the sensor is exposed to fresh air for more than 30 minutes
- Pressure measurements range: 10 to 1200 hPa
- Accuracy (min): ±1.5 (25°C, 750 hPa)
- Accuracy (max): ±2.5 (-20°C to + 85°C, 300 to 1100 hPa)
- Resolution: 1 hPa
- Ingress protection: IP20
- Operating voltage range: 4.5…26 VDC
TSH202B is a compact humidity and temperature sensor with 1-Wire interface. It is ideal for use in a variety of applications where space is limited, such as environmental monitoring systems, HVAC control, and more.
- Fully calibrated digital output
- Excellent long-term stability
- A unique 64-bit serial number for multi-sensor systems
- 3.0% relative humidity accuracy
- 12-bit resolution for humidity measurements
- 14-bit resolution for temperature measurements
Compact sensor VA 525 for measuring compressed air or nitrogen inline.
- 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
- Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
- Pressure range up to 16 bar
- Temperature range up to 60°C
- For speeds up to 224 Nm/s
- Integrated display to show the measured values
- Available from 1/4" to 2''
- Settings adjustable via the keys of the display
- Main counter can be reset via the display
- Triton Vape Detector of vaped and burn nicotine, THC, and other substances. Does not differentiate the substances
- Monitoring of Humidity, Particulate Matter Index and VOC Index
- Rejects most aerosols with a similar profile to vape/smoking
- Alert Options: SMS Text Message, Email, App, Notification, 3rd Party Integration, Audible Alarm
- Tamper protection: Device Vandalism, Device Disconnect, Masking and Sensor Cover, Ultra-loud alarm to dissuade tampering
- Integrations: Integrates with numerous 3rd party video management systems to give context to alerts through automatic camera recording
- Manage devices through the Triton Sync online dashboard and app in Cloud. Real-time monitoring and customizable alerts
- Operating environment Temperature / Humidity: 0…40 °C / 0…90 % RH (non-condensing)
- Power Supply PoE (IEEE 802.3af Class 3 Compliance) 9W 48V
- RS-485 (Modbus) protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 5...95 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
- Resolution: 12 bits for temperature and humidity
- Long-term stability
- Warranty: 3 years
- 1-Wire protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 10...90 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (10...90 %RH) / ±0,4 °C (-10...+60 °C) / ±1 °C (-20...+60 °C)
- Resolution: 14 bits for temperature, 12 bits for humidity
- Long-term stability
- Warranty: 3 years
- Connection: RJ-11
- RS-485 protocol temperature and humidity sensor
- Temperature measurement range: -20...+60 °C
- Humidity temperature range: 5...95 %RH
- Accuracy: ±3 %RH (20...80 %RH) / ±5 %RH (5...95 %RH) / ±0,4 °C (-10...+60 °C) / ±0,6 °C (-20...+60 °C)
- Resolution: 14 bits for temperature, 12 bits for humidity
- Long-term stability
- Warranty: 3 years
- Connection: RJ-45
Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.
- Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
- Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
- CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
- Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
- Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
- Air quality (VOC) measuring range: 0…100 %
- Data output: galvanically separated RS-485 Modbus RTU interface
- Variants: with / without LCD display
- One sensor covers about 30 m² of room area
- Power supply: 24 V ac/dc (200 mA)
- Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
Thermal mass flow sensor for compressed air and gases VA 500
- 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
- Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
- Optional: Bi-directional measurement
- Pressure tight up to 50 bar
- Temperature range up to 110 °C
- Protection class IP65
- Suitable for gas velocities up to 224 Nm/s
- Integrated display for showing the measured values
- Can be used from 1/2" up to 40", larger diameters on request
- Easy installation under pressure
- Settings can be changed via the display
- Main counter reading can be reset via the display
Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:
- Periodic measurement of solid state particle concentration in stationary sources of emission
- Solid state particle concentration measurement in gasses
- Testing of dust removal equipment
- Gas flow rate measurement
- Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
- Dioxins, furans, PAH, mercury concentration measurement
- Heavy meal, HCL, HF concentration measurement
A simple handheld, accurate vape particulate, vape smoke detector FD-VAPE-HAND that indicates air quality for home, work, vehicles, or other occupational spaces. Excellent to detect vape, cigarette smoke, and e-cig smoke.
- Sensor: Laser scattering PM1.0, PM2.5, PM10 sensor
- Detection Range: 0-1000 µg/m3
- Response Time: <10 seconds
- Temperature measurement range: 0…50 °C (can be selected between Fahrenheit and Celsius)
- Humidity measurement range: 10…95 %RH
- Sound alarm when vape detected
- Auto off: after 5 minutes
- Power: 1000 mAh Li-Ion Battery, up to 8 hours of operation, (recharge USB 5V/1A)
- Dimensions: 5,1 x 1,8 x 8,6 cm
- Weight: 142 gr
SM400-4-TH humidity and temperature sensor supports MODBUS RTU protocol over the RS-485 interface. Suitable for environmental quality monitoring offices, server room, data center and indoor air
- Changeable communication parameters
- Non-volatile memory for all settings
- Operating temperature range: -20…60°C
- Accuracy (min): ± 0.4 °C (in -10…+ 60 °C range)
- Accuracy (max): ± 0.6 °C (in -20…+ 60 °C range)
- Resolution: 0.1 °C
- Operating relative humidity range: 10…90% (non-condensing)
- Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
- Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
- Resolution: 0.1 % RH
- Ingress protection: IP20
- Operating voltage range: 4.5…26 VDC
The CM22 provides essential video security features in a compact form. It is a 3MP (2048x1536) camera with 10 meters of IR light range, and includes people and vehicle detection for motion search and trajectory analysis. The CM22 camera, combined with the SV23 vape detector and air quality sensor, and powered by the Verkada Command cloud computing platform, creates a powerful vape prevention and logging system.
- 30, 60 and 90 days of data retention (256…768 GB) on hardware and cloud back-up. If the connection to the Command cloud is lost, data is saved onboard and synced once the internet connection is restored
- Easy to install: no NVR, DVR, servers or port forwarding, just PoE connection
- Alerts: Camera status (offline), motion detection, people detection, vehicle detection, crowd detection, line-crossing detection, loitering detection
- Privacy: live face blur, privacy regions and audit log
- Field of view: Horizontal: 95°; Vertical: 69°; Diagonal: 130°
- Operating temperature / humidity: -10…50 °C / 0…90 %
- Connection and power input: RJ-45, PoE (IEEE 802.3af type 1)
- Certifications: FCC, ICES, RCM, VCCI, CE, UKCA, EN 50155 railway compliance, UL/cUL/IEC 62368-1, NOM
- Warranty: 5 years
Indoor temperature meter / transducer Txx18, designed for temperature, humidity and barometric pressure measurement.
Analog laser light barriers and their electronic control units. Round or rectangular cross-sections are used for measuring, positioning or detection of objects starting from 0,01 mm (i.e. threads) from great distance (up to 100 m, depending on model).
C-LAS compact laser light barriers are ideally suited for positioning tasks.
The new leak meters LD 500/510 with integrated camera and leakage calculation are ideal to find even smallest leakages (0.1 l/min) easily even in far distances and calculate potential saving (€/year).
- 30 MEMS digital microphones for image of leaks
- Measuring distance: up to 6,5 m
- 3,5” TFT color display with touch panel
- Additional sensor input to measure: dew point, flow, pressure, and temperature (LD 510 only. See datasheet)
- Possibility to take photo of leaking parts
- Data transfer via USB to PC
- Easy data and work assignment with CS Leak Reporter cloud solution
- ISO 50001 report
- Power supply: 7,2 V lithium-ion battery (> 9 h continuous operation)
- Operating temperature: -5…+40 °C
The enLink IAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (0.1, 0.3, 0.5, 1.0, 2.5, 5.0 & 10), Barometric pressure, Sound*, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
- Distinguishes between vaping and smoke and counts the number of detections
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours or adaptive (triggered by vape or smoke)
- Power suplly: 12…24V V DC, 0.15 Amp (max)
- Configuration via USB cable / downlink
- Operating Temp. / Humidity: 0…40 °C / 0…95 % RH
The enLink OAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (1.0, 2.5, 4.0 & 10), Barometric pressure, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours
- Power supply: 12…24V V DC, 0.15 Amp (max) / 4 x Li-SOCl2 (3.6V) AA / external solar panel
- Configuration via USB cable / downlink
- IP rating: IP42 (conformally coated electronics), do not expose to direct sunlight
- Operating Temp. / Humidity: -10…40 °C / 0…95 % RH (be kondensacijos)
The Wx9xx series of sensors from COMET SYSTEM enables accurate measurement of temperature, relative humidity, and atmospheric pressure, with data transmitted via the low-power LoRaWAN network. This technology allows data to be sent to a cloud storage, where users can easily view both current and historical values through a standard web browser. Each sensor has an LCD display showing the measured value and battery status.
- Possibility to connect Pt1000 sensors
- Covers up to 15 km in rural areas and 2…5 km in urban areas
- Work with Comet System LoRaWAN gateway SP041
- Battery life: from 1 to 10 years depending on transmission time and environment temperature
- Unlimited space for data in cloud
- Alarm: email and app notification
- Mobile applications for Android and iOS
- Wide gap between the two parts of sensor
- Protection class: IP65
- Max switching voltage: 100 V
- Max switching current: 0,5 A
- Cable length: 0,45 m
- Warranty: 3 years
The device is designed to measure ambient air pollution by detecting concentration and distribution of particles.
The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.
- Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
- Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
- Tamper protection: device vandalism, masking and covering
- Real-time monitoring of student loitering via live video streaming
- No license subscription required for use
- The sensor independently performs all measurements and detections and sends alarms itself
- *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
- Event logging of alarms in the device
- Communication: LAN, WiFi
- Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
- Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
- Measured parameters (with respective sensors):
a) Temperature (Pt100 or thermocouple)
b) Humidity
c) Air quality
d) Air velocity
e) Airflow
f) Tachometry - Two inputs for Pt100 temperature sensors (range -200...600 °C)
- Up to 6 measurements simultaneously
- Power supply: Lithium-Ion battery (up to 57 hours)
- Calibration certificate, additional battery, transport case included
- Operating temperature: 0...50 °C
- Protection class: IP54
The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.
- 30 - 365 days (1TB - 8TB) of onboard storage
- Redundant cloud backup and unlimited cloud-based archiving of footage
- Sensor Resolution: 4 x 5MP (2688 x 1944)
- Protection class / Impact rating: IP66 / IK10
- Operating temperature: -40…+50 °C
- Warranty: 10 Years
- Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant
The instrument uses a pH/ORP sensor and RTD Pt100 temperature sensors. If the Pt100 is connected the transmitter makes automatic temperature compensation (pH only).
- pH range: 0 ÷ 14.00 pH
- ORP range: 0 ÷ 1000 / 0 ÷ -1000 / -1000 ÷1000 / 0 ÷ 2000 / 0 ÷ -2000 mV
- Temperature range: -10.0 ÷ 110.0 °C / 14.0 ÷ 230.0 °F
- Resolution: 0.01 pH, 1 mV, 0.1 °C
- Digital output: RS-485 isolated
- Analog output: 4-20 mA galvanically isolated, "current loop" two wires
- Power supply: 9 / 36 Vdc
- Dimensions: 71x95x58 mm. Rail Din (4 modules)
- Operating temperature: 0…+50 °
- EMC/RFI conformity: EN 61326
pH electrode sensors (glass, epoxy body and submersible)
- Oxygen concentration measuring in air and inert gas mixtures
- Specially developed for use in composting plants
- Measuring range of oxygen concentration: 0,1…25 % (0…100 % range on request)
- Value indicator of measured oxygen concentration
- Output: 4…20 mA analog or bidirectional digital signal (for calibration, operation diagnostic)
- Length and diameter of the sensor protection tube to the handle: 1200 x 30 mm
- Length of the protective tube part to be stuck in the compost heap: ~ 1000 mm
- Material of protective tube: Stainless steel 1.4301
- Housing ambient temperature: -10…+50 °C
- Probe ambient temperature: -10…+100 °C
- Protection class of housing electronic: IP65
- Protection class of probe: IP40
- Rechargeable battery with indication of voltage
- It is possible to connect the sensor to a stationary data processing system
Tempmate-S1 data loggers are specially designed for temperature monitoring in any cold chain logistics. The automatically created PDF and CSV report, containing detailed information such as data curve, every single measurement as a table and statistical information.
- Relay output
- Smoke sensitivity complies with EN 54-7:2000+ A1:2002
- Digital signal processing
- Very low current consumption
- Excellent long-term stability
- LED indication
- Supply: 10...30 VDC
- Warranty: 3 years
For on-line measurements of air pollution or combustion gases flow in chimneys or flues.
- Temperature measurement range: -100…+300 °C
- Accuracy: ±0.07 °C (-10…+100 °C); ±0.15 °C (+101…+150 °C); otherwise ±0.4 °C
- Resolution: 0.01 °C
- Memory: 32 000 readings
- Power supply: battery 3.6V 1/2AA
- Operating temperature: -30…+70°C
- Protection class: IP65
- Wall mount available as optional accessory