This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Sulfur dioxide (SO2) detectors

Sulfur dioxide (SO2) detectors
Показать:
Сортировка:
  • Applications of flue gas analyzer Si-Ca 230: boilers, burners, water heaters, gas and diesel engines, furnaces, industrial kilns, industrial heating systems, incinerators
  • Detectable gases: O2, CO (H2 comp.), CO2, NO, Low NO, NO2, Low NO2, NOx, Low NOx, SO2, Low SO2, CxHy (HC), H2S
  • Up to six gas sensors
  • CO measurement up to 50 000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
  • Color graphical touchscreen for control
  • Communication: USB, Bluetooth (mobile App), remote printer
  • Measurement storage: 2000 data points + smartphone and PC
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping

The enLink OAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (1.0, 2.5, 4.0 & 10), Barometric pressure, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • Power supply: 12…24V V DC, 0.15 Amp (max) / 4 x Li-SOCl2 (3.6V) AA / external solar panel
  • Configuration via USB cable / downlink
  • IP rating: IP42 (conformally coated electronics), do not expose to direct sunlight
  • Operating Temp. / Humidity: -10…40 °C / 0…95 % RH (be kondensacijos)
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution < 0,1 / 1,5 ppm SO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 2 / 5 ppm SO2
  • Attached or remote sensor
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution 0,1 / 1,5 ppm SO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...50 ppm SO2 / 0...2000 ppm SO2
  • Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265
Loading...