This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Датчики давления

Датчики давления
Показать:
Сортировка:
  • 1-Wire protocol ambient pressure sensor TSP200
  • Pressure measurement range: 300...1100 hPa
  • Excellent long-term stability
  • Warranty: 3 years
  • Connection: RJ-11
  • Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
  • Air flow and velocity measurement
  • Output: 0...10 V / 2...10 V or 4...20 mA
  • Option: autozero function and LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -40...+50°C (see datasheet)
  • Protection class: IP54
  • To measure air and neutral gases pressure in range -100...100 Pa
  • Solenoid valve for auto-calibration: frequency 1…60 min
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -100...100 Pa
  • Accuracy: ± 1 % of reading ± 2 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output: 0-10 V and 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply: 24 V AC / V DC
  • To measure air and neutral gases pressure in range -1000...1000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -1000...1000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 Pa
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
  • Overpressure tolerated: 21 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -2000...2000 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -2000...2000 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 4100 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
  • To measure air and neutral gases pressure in range -500...500 mbar
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -500...500 mbar
  • Accuracy: ± 1.5 % of reading ± 3 mbar
  • Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
  • Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
  • Response time: 0.3 s
  • Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 1400 mbar
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
  • PID controller
  • 2 set points (SP), chosen by binary input
  • Pressure measurement range: -250...2500 Pa
  • Output: 0...10 V
  • Input: NTC10, NTC20, Pt1000, Ni1000
  • LCD screen
  • Temperature compensation
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...2500 Pa
  • 8 field selectable measurement ranges (via jumper)
  • Output: 4...20 mA
  • Option: LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -10...+50°C
  • Protection class: IP54
  • Two pressure transmitters in one device
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Option: DPT-DUAL-MOD-AHU – with air flow transmitter
  • Output: Modbus RTU
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Input: 2 x  0...10 V, NTC10k, Pt1000, Ni1000, binary
  • Output: Modbus RTU
  • Temperature compensation in range of 0...50 °C
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Pressure measurement range: from 0...1 bar to 0...6 bar
  • Made to be used for air-conditioning, heating and water systems
  • For neutral fluids and non-aggressive gases, compatible with refrigerants
  • Output: 4...20 mA
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+80°C
  • Protection class: IP65
  • Input: differential pressure
  • Typical areas of use are chemical industry and process engineering
  • Measurement range: 75 mbar...70 bar
  • Output: 4...20 mA HART
  • Supply: 12...30 VDC
  • Operating temperature: -40…+85 °C
  • Protection class: IP65
  • Process connection: 1/4-18NPT
  • Pressure range: from 0...1 to 0...16 bar
  • Output signal: 4 ... 20 mA (P1–P2)
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f
  • Protection class: min. IP65
  • PID controller
  • Pressure measurement range: 0...2500 Pa / 0...7000 Pa
  • Switchable between air flow and pressure measurement
  • Output: 0...10 V / 4...20 mA
  • Option: autozero function
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • PID controller
  • Pressure measurement range: 0...2500 Pa
  • Modbus RTU communication
  • Control output: 0...10 V
  • External input: 0...10 V / thermistor / binary
  • LCD display
  • Temperature compensation
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65

The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
  • Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Membrane in Duplex steel 1.4462
  • Pressure connection: G1/2” male, flush membrane
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
  • Hydrogen pressure transmitter’s measuring principle: Thin-film-on-steel
  • EC79 and ECER-134 certification pending (see product website for current situation)
  • Applications: Fuel cells, fueling stations, hydrogen compressors, hydrogen tanks, vehicles with H drive
  • Measuring range: 0…1050 bar / 0…15000 psi *(see product datasheet)
  • Measuring accuracy at 25 °C typ.: ± 0.3 / 0.5 % FS typ.
  • Output signal: 4...20 mA, 0.5...4.5 VDC, 0...5 VDC, 1...5 VDC, 1...6 VDC, 0...10 VDC, 0.1...10.1 VDC, 0.5...4.5 VDC ratiometric, Switching output: 1 or 2 PNP
  • Pressure connections: G1/4" m, 1/4"NPT m, 7/16"-20UNF SAE4 m
  • Ambient temperature: 40°C…+85°C
  • Industrial pressure transmitter’s measuring principle: Thin-film-on-steel
  • Applications: hydraulics, industrial applications, machine tools
  • 5-fold overpressure resistance
  • Measuring range: 0...2.5 / 0...700 bar // 0...30 / 0...10000 psi
  • Measuring accuracy at 25 °C typ.: ± 0.5 % FS typ. ± 0.3 % FS typ
  • Output signal: 4...20 mA, 0...5 VDC, 0.5...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Ambient temperature: -40°C…+125°C
  • Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (in range: 0...100 m/s) and flow m3/h
  • Sheathed thermocouple K probe integrated, with connection cable length 1,5 m (option)
  • Introduced perpendicularly in the pipe
  • Particularly adapted for measurement in warm air, charged with particles and for high speed
  • Accuracy: Better than 1 % for an alignment in relation to the flow axis of the fluid of ± 10 °
  • Coefficient: 1,0015 ± 0,01
  • Max static pressure: 2 bar
  • Temperature of use: 0…600 °C (up to 1000 °C in option)

PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T4611, T3611, T7611. Only to be used with external sensors.

Application:

  • Storage rooms
  • Greenhouses
  • Telecommunication devices
  • Servers
  • A/C units

PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T0610, T3610, T7610. Only to be used with internal sensors.

Application:

  • Storage rooms
  • Greenhouses
  • Telecommunication devices
  • Servers
  • A/C units
  • Measuring range: -1…100 bar (see datasheet)
  • Basic accuracy 0,5% of range
  • Output: 4…20 mA
  • Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
  • Operating temperature: -20…+85 / 200 °C (see datasheet)
  • Stainless steel housing and diaphragm material
  • Protection class: IP67 / IP68
  • Pressure range: from 0...2,5 to 0...700 bar
  • Process temperature: -40...+125 °C
  • Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
  • Protection class: IP65, IP67
  • Pressure transmitter ATM (analog output)
  • Pressure measurement range: from 0 to 0,1...1000 bar
  • Accuracy: < ± 0,50 / 0,25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
  • Process temperature: -40...150 °C
  • Operating temperature: -25..85 °C
  • Materials: stainless steel, titanium
  • Pressure transmitter ATM.1ST/Ex (high precision, for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Output: 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -40...125 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
  • Pressure transmitter ATM/Ex (for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, IECEx, EAC
  • Pressure transmitter ATM/F (hygienic)
  • Various pressure measurement ranges: 0,1...25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process temperature: -25...100 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel
  • Pressure transmitter ATM/F/Ex (hygienic, for explosive Ex environment)
  • Various pressure measurement ranges: 0,1...25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
  • Process temperature: -25...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel
  • Certificates: ATEX, EAC
  • Pressure range: from 0...0,1 to 0...40 bar
  • Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
  • Applications: Machine tools, hydraulics, water treatment
  • Protection class: IP65, IP67, IP68
  • Certificates Ex ATEX and IECEx
    • Ex-zones 0, 1, 2 (gas), 20, 21, 22 (dust) and mining
  • High reliability and safety
  • Extraordinary long-term parameter stability
  • Range:
    • from 0...0.4 bar to 0...2000 bar
    • standard 0...0.4 bar to 0...250 bar
    • accuracy: ± 0.2% of range
  • Process connection: G1/4"
  • Output: 4...20 mA
  • Process temperature: -40°C...+120°C
  • Ambient temperature: -40°C...+120°C 
  • Supply: 10...30 VDC
  • Protection class: IP65
  • Casing material: stainless steel 1.4452 (AISI630)/ 1.4301 (AISI304)
  • Pressure range: from 0...6 to 0...600 bar
  • Output signal: 4...20 mA / 1 x PNP / 2 x PNP
  • Process temperature: -40...+125 °C
  • Accuracy: 0,3 %
  • Dielectric strength: 710 V
  • Measurement principle: thin film on steel
  • Protection class: IP65, IP67
  • Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
  • Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
  • Pressure transmitter PTM (programmable)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Various pressure measurement ranges: 0,1...1000 bar
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, EAC
  • Various pressure measurement ranges: 0,1...1000 bar
  • Temperature measurement range: -25...85 °C
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 2 x 4...20 mA
  • Digital output: RS-485
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Various pressure measurement ranges: 0,1...1000 bar
  • Relay output: 2 units
  • Output: 0...20 mA / 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Measuring function: differential pressure, volume flow
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
  • Allowed overpressure: 50 kPA
  • Supply: 24 VAC
  • Medium: clear air, non-aggressive, non-combustible gases
  • Protection class: IP 54
  • Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
  • The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
  • Introduced perpendicularly in the pipe
  • Particularly adapted for measurement in warm air, charged with particles and for high speed
  • With integrated K type thermocouple
  • Accuracy: 1 %
  • Coefficient: 0,84 ± 0,01
  • Static pressure: Atmospheric
  • Temperature of use: 0…1000 °C

Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.

Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.

  • Flow and temperature sensor for liquids in pipes
  • Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
  • Flow measurement range: 1...150 cm/s (water)
  • Temperature measurement switching points: 15, 30, 45, 60, 75 °C
  • Flow rate measurement is shown in a bar graph by five green LEDs
  • Settings provided by magnetic pen
  • Stainless steel case
  • Supply: 12...34 VDC
  • Ambient temperature: -20...+80 °C
  • Protection class: IP67 / IP68

Sensor measures carbon dioxide (CO2) concentration, temperature, and atmospheric pressure. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • CO2 measurements:
    • Range: 0…9999 ppm
    • Resolution: 1 ppm
    • Accuracy: ± (30 ppm + 3 % of reading)
  • Atmospheric pressure measurements:
    • Range: 300…1100 hPa
    • Resolution: 1 hPa
    • Accuracy: +3 hPa / -2 hPa
  • Temperature measurements:
    • Range: 0…50 °C
    • Resolution: 0,1 °C
    • Accuracy: ± 0.3 °C
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply: 1 x AA battery
  • Battery lifetime (20 °C): up to 8 years
  • Operating temperature: -40…60 °C
  • Protection class: IP67
  • Suitable for thick and viscous media
  • Different materials for optimum media compatibility
  • EMC protection class is IEC 61000 (lightning, electrical discharge)
  • Range: 0...0,1 bar to 0...6 bar
  • Accuracy: +/- 0.3 %
  • Output: 4...20 mA
  • Ambient temperature: -25°C...+70 °C
  • Process temperature: -25°C...+70 °C
  • Supply: 9...32 VDC
  • Protection class: IP68
  • Material: Stainless steel (1.4404 (316L) / 1.4462 (318LN))
  • Sensor technology: Thick film on ceramic
  • Sensor material: Ceramics, Al2O3 96%
  • Cable insulation: PUR / Radox / PE

Pressure transmitter CMP 8270 with CANopen output is designed for pressure measurement from 0...1 bar to 0...600 bar. Medium accuracy, small size, high temperature- and strong vibration-resistant.

  • Output: CANopen, protocol DS301 / DS404 
  • Range: from 0...1 bar to 0...600 bar 
  • Accuracy: ±0,2%
  • Process connection: G¼ 
  • Supply: 8...32 VDC
  • Temperature: -50...135ºC
  • Ambient temperature: -40...125ºC
  • Sensor material: stainless steel (1.4542)
  • Protection class: IP67
  • Pressure transmitter for shipbuilding, engine manufacturing
  • Measured pressure from 0...1 bar to 0...250 bar
  • Technology: thick film on ceramic
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %
  • Operating temperature: -25...+125 °C
  • Ambient temperature: -25...+125 °C
  • Conformity: DNV, GL, KRS, RINA
  • Protection class: min. IP68

Pressure transmitter EPN/EPNCR 8298 is suited for ship industry (up to 2500 bar). Totally enclosed, stainless steel sensor system. Long-term reliability and stability, resistance to mechanical factors.

  • Range: nuo 0...2,5 iki 0...2500 bar
  • Accuracy: ± 0,3%
  • Output: 4...20mA / 0.5...4.5V DC
  • Process connection: G1/4“, R1/4“, G1/2“, M14x1.5, M18x1.5
  • Process temperature: -40°C...+125°C
  • Supply: 9...32 VDC / 5 VDC ±0.25 VDC
  • Protection class: IP67
  • Sensor material: nerūdijantis plienas 1.4548 (AISI630)     
  • Certification: GL, ABS, BV, DNV, RINA, LRS, KRS, NKK, RMRS
  • Pressure transmitter is suited for ship industry, has extended temperature range and increased accuracy, M12 connection and IP67 protection class
  • Small size
  • Totally enclosed, stainless steel sensor system
  • Long-term reliability and stability, resistance to mechanical factors
  • Range: from 0...2,5 to 0...700 bar
  • Accuracy: ± 0,2%
  • Output: 4...20 mA
  • Process connection: G1/4" m; G1/4" m (Manometer EN 837); G1/8" a, DIN3852-E; 1/4"NPT m; M10x1 m
  • Process temperature: -25°C...+125°C
  • Ambient temperature: -40°C...+125°C
  • Supply: 9...32 VDC
  • Protection class: IP67
  • Sensor material: Stainless steel (1.4542)
  • Certification: ABS, BV, DNV, GL, KRS, LRS, RINA, for shipbuilding
  • Pressure transmitter for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measured pressure from 0...2,5 bar to 0...250 bar
  • Technology: thick film on steel
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %, 0,3 %
  • Operating temperature: -40...+100 °C
  • Ambient temperature: -40...+100 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS
  • Increased vibration resistance
  • Totally enclosed, stainless steel sensor system
  • Long-term reliability and stability, resistance to mechanical factors
  • Measurement range: from 0…2 to 0…2.5 bar
  • Accuracy: 0,15...0,8 % (at 25 °C
  • Output: 4...20 mA, 0...5 V, 0...10 V
  • Process connection: G1/4 (optional G1/2 with additional adapter), 1/4” NPT
  • Process temperature: -40°C...+125 °C
  • Ambient temperature: -40°C...+125 °C
  • Supply: 9/15...32 VDC
  • Protection class: IP65 / IP67
  • Sensor material: stainless steel (1.4542)
  • To measure air and neutral gases pressure in range -10 000...10 000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -10 000...10 000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 mmH2O
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional):0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 69 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
Loading...