This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Другие продукты

Другие продукты
Показать:
Сортировка:

Astronomical digital clocks RAT-TPA1B are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise with an option to program a night break, which means a temporary switching off of the receivers for savings purposes

  • 52 programs, holiday mode
  • Automatic summer/winter digital clockover
  • Automatic transfer of weekdays
  • Sealable cover of the front panel, easy setting by 4 buttons
  • Backlighted LCD display (can be turned off)
  • 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
  • Number and type of contacts: 1 CO
  • Rated load: 16 A / 250 V AC
  • Direct mounting on 35 mm rail mount acc. to EN 60715
  • Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS
  • Designed to be weld-in into pipelines and boilers
  • Instrument standard threads (F): G1/2", G1/4"
  • Dimensions according to customer's needs
  • Case production: solid or welded
  • Available materials: 1.4301 (AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
  • Dimension tolerances according to DIN ISO 2768
  • Available other materials, threads, flanges and dimensions
  • Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
  • Standard instrument threads (F): G1/2", G1/4"
  • Dimensions according to customer's needs
  • Case production: welded or solid (flange welded)
  • Available materials: 1.4301(AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
  • Dimension tolerances according to DIN ISO 2768
  • Available other materials, threads, flanges and dimensions

Solid drilled threaded thermowells, protective cases:

  • Protect and extend the lifetime of temperature sensors and thermometers in processing applications
  • Facilitate the replacement of sensors
  • Allow sensor maintenance without process interruption

A and B connection threads:

G1/4, G1/2, M20x1,5, M10x1, M12x1,5, M20x1,5, G3/4, M16x1,5, M22x1,5,

Spec,  G1/2L*

*  -  left-hand thread

 

Material: stainless steel-DIN 1.4301 (AISI 304)

Note: other ordering versions possible.

Thermowells protect and extend the lifetime of temperature sensors and thermometers in processing applications where the sensors are not mechanically or chemically compatible with the process environment. Moreover, thermowells facilitate the replacement of sensors and allow sensor maintenance without process interruption.

  • Communicates with devices supporting HART and LHP interfaces
  • Supports universal, common commands
  • HART connector: BNC
  • Supply: 9 V accumulator (charged via USB)
  • Operating temperature: -20...+50 °C
  • Operating humidity: 0...80 % RH
  • Protection class: IP40
Inserts for thermocouple sensors (changeable, with ceramic block). Technical specifications Example Model Range Sensor Accuracy Measuring tube   w2 -40 ... +1150°C K (NiCr-NiAl),J (FeCu-Ni)  1 class (standard)or 2 according to EN 60751   INCONEL 600 w4 0 ... +1800°C ceramics C610 ir C79..
Non-reversible temperature labels, 10 temperature ranges.  A °F°C 10440  10842 11144 11546 12049 12954 14060 14462 14965 16071  B °F°C  17177 18082 19088 19993 21099 ..
  • Mounting brackets for easy installation of temperature sensors in measuring point
  • UZ11 – full bracket
  • UZ21 – bracket without body (only flange)
  • Diameter: 15 / 22 / 32 mm
  • Body and flange material: 1.0401 steel
  • Sealing part material: Teflon / glass fiber
  • High quality
  • Complies with DIN EN 50 446

Multifunction astronomical digital clocks RDT-TPA2 are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise.

  • 80 programs (astronomical and annual), holiday mode, random mode
  • Automatic summer/winter digital clockover
  • Automatic transfer of weekdays
  • Sealable cover of the front panel, easy setting by 4 buttons
  • Backlighted LCD display (can be turned off)
  • 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
  • Number and type of contacts: 2 CO (each channel can be assigned an individual program)
  • Rated load: 16 A / 250 V AC
  • Direct mounting on 35 mm rail mount acc. to EN 60715
  • Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS

The innovative Leybold SOGEVAC B single-stage oil sealed rotary vane pumps are ideal for modern industrial applications distinguished by low noise levels, high pumping speeds and high reliability.

  • Compact design and small footprint
  • No motor coupling up to SV65 B
  • Very low oil emission
  • State of the art sealing technology
  • Very low noise level in any working condition
  • Customized configurations possible
  • Simplified maintenance and service

SOGEVAC B pumps have a pumping capacity range from 10 to 750 m3/h @ 50 Hz with an ultimate pressure of ≤ 8 X 10-2 mbar.

Industry proven double stage rotary vane pumps with a performance driven and low noise design.

Leybold TRIVAC B oil sealed double stage vane pumps are well known and being used in all areas of vacuum engineering and are equally suited for both industrial production and research applications. The TRIVAC B pumps, used to generate a rough and medium vacuum or as backing pumps in pump combinations with Roots vacuum pumps or high vacuum pumps, have the ability of pumping down from the atmosphere.

  • Compact design and small footprint
  • No motor coupling up to SV65 B
  • Very low oil emission
  • State of the art sealing technology
  • Very low noise level in any working condition
  • Customized configurations possible
  • Simplified maintenance and service

The TRIVAC B range is available in six different sizes with an ultimate pressure of 10-4 mbar and a pumping speed in the range of 4 m3/h to 65 m3/h.

Industrial vacuum pumps for the rough vacuum industry.

The CLAWVAC series of oil-free industrial dry vacuum pumps have a corrosion-resistant pump chamber and stainless-steel claws. This makes them extremely robust, especially for challenging applications which include handling of particles and vapor-contaminated gases. The CLAWVAC dry vacuum pumps are simple to use, easy to clean onsite and have efficient air cooling that let’s our customers experience a trouble-free and cost-saving operation.

CLAWVAC can replace your liquid ring vacuum pump.

Thanks to its unique design, CLAWVAC combined with the right Leybold accessories can replace a liquid ring vacuum pump in many processes.

Switch to dry claw technology for cost savings:

  • Huge cost savings: no water consumption, no water treatment or disposal
  • Lower power consumption
  • Stable process performance, independent of water temperature
  • Better environmental impact of your industrial plant, as water is a valuable asset
Overload protector 05-04. Designed to protect pressure measuring devices from too fast or too big step change of pressure. This device blocks bigger than expected pressure until system gets back into normal state. Technical specificationsMaximum working pressure: 400 bar;Process connection: 1/2 BSP MxF, 1/2 NPT MxF, 1/4 BSP MxF, 3/8 BSP MxF, 3/8 NPT MxF;Material of construction: AISI 316 SS;Operating temperature: -40°C .. 120°C;  05-04 datasheet [EN] ..
  • Supports devices: NAT 8252, NAH 8254, NAR 8258, ECL 8439
  • Fast and easy operation via Android app “Sensor Master Communicator SMC”
  • Read out of sensor data
  • Parametrization of switich points on NAx pressure switches
  • Measuring range adjustment on submersible pressure transmitter ECL
  • Reset pressure measurement instruments to factory settings
  • Ambient temperature: 0...40 °C
  • Supply: 5 V (USB)
  • Communication: Bluetooth Low Energy
  • Protective transparent flexible rubber casings for panel-mounted devices, designed to increase device front protection class to IP65
  • The casing does not interfere with pressing of buttons
  • Protects from wear-out and erasing of writings
  • Thermosetting cabinet with double doors. The cabinet dimension: 600 x 500 mm (max 2x 5,5 kW) or 800 x 600 (max 2x 7,5 kW; ... max 2x 22 kW).
  • Plinth or foundation for fixing the cabinet.
  • PLC controller with a display that changes the backlight depending on operating mode.
  • Program saved in the controller and on the SD card, enabling transferring the program to another controller in the event of a failure.
  • Router equipped with a 2G / 3G / 4G / LTE modem, 1 LAN 10 / 100 Mb/s port and radio module in the 802.11 b/g/n standard, supporting MIMO 2x2.
Fluid level electrode ASTA 460 MM4.  Electrode length 460 mm Electrode material Stainless steel (AISI 304) Thread M4  More information on electrode extension ASTA 460 MM4 on Lovato website [EN] ..
Stainless steel gauge cock, vent hole type. Technical specificationsProcess connection:  in case of 3 way gauge cock 1/2 (MxFxF), in case of 2 way gauge cock 1/4, 1/2, 3/8, (FxF), (MxF), (MxM); Operating temperature: up to 180 °C;Max pressure: up to 100 kg/cm²;Housing: stainless steel AISI 316 SS;  05-03 datasheet [EN] ..
  • 300Mbps wireless data rates
  • Tiny
  • Supports AP (default), Client, Router, Repeater and Bridge modes
  • Powered through a micro USB port by an included external power adapter or USB connection to a computer
  • Compatible with Comet System devices which have Ethernet interface
  • Rated load: 5...500 kg (chosen from list)
  • Output: 2 mV/V
  • Connection: 3 m cable, 4-wire
  • Operating temperature: -35...+65 °C
  • Supply: 10 VDC
  • Protection class: IP67
  • Rated load: 20...10 000 kg (chosen from list)
  • Output: 2 mV/V
  • Connection: 3 / 6 m cable, 4-wire
  • Operating temperature: -35...+65 °C
  • Supply: 10 VDC
  • Protection class: IP66 / IP67
Pressure peak damping element, designed to be used to protect measuring devices from sharp pressure changes in system. Made by Trafag (Switzerland).Environment: air, waterProcess connection: G1/4 male, G1/4 female (brass), G1/2 male, G1/4 male (stainless steel)Material: Stainless steel (model K5) or brass (model F5) Pressure peak damping element datasheet [EN, DE, FR] ..
  • Rated load: 1000 / 1500 / 3000 kg
  • Output: 4...20 mA HART / 10 VDC
  • Function: tension / compression / tension and compression
  • Vibration protection
  • Operating temperature: -25...+60 °C
  • Supply: out of current loop / 10 VDC
  • Protection class: IP54
  • Used for measuring range extension and conform to EN 60051 standard
  • Can be used in various measuring systems
  • Shunts are selected by nominal current (1 – 15000 A)
Loading...