This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Контроллеры, регуляторы

Контроллеры, регуляторы
Показать:
Сортировка:
  • Stable long-life electrochemical gas sensor
  • Range 0...5 ppm O3
  • Resolution 0,03 % ppm O3
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Stable long-life metal-oxide gas sensor
  • Range 0....1000 ppm NH3
  • Resolution 1 ppm NH3
  • Default alarms at 25 ppm / 35 ppm NH3
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, (0...10000 on request) ppm NH3
  • Resolution: 1 / 2 / 5 ppm NH3
  • Sensor lifetime: > 2 years
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -10...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Range: 0...1000 ppm NH3
  • Resolution: 1 ppm NH3
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C / 15...90 %RH
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • NDIR gas sensor
  • Range: 0...50 000 ppm CO2 (up to 100 % CO2 on request)
  • Resolution: 0.01 % vol.
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -25…+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Electrochemical (CO) and optical NDIR (CO2) gas sensors
  • Range: 0...100 ppm CO, 0...10000 ppm CO2
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Electrochemical gas sensors
  • Range: 0...100 ppm CO, 0...20 ppm NO2
  • Resolution: 1 ppm CO, 0,1 NO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Operating temperature: -20...+50 °C
  • Supply: 24 VDC/VAC
  • Protection class: IP65
  • Photo ionization detector
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: isobutylene
  • Range: 0...40 / 0...200 ppm (isobutylene)
  • Resolution: 1 / 1 ppb
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+65 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: toluene
  • Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
  • Resolution: 0,1 % LEL / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...5 ppm O3
  • Resolution 0,03 % ppm O3
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 0,3 / 1 ppm O3
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...5 ppm O3
  • Resolution: 0,01 ppm O3
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Input (single option): 100 V, 250 V, 400 V, 1 A, 5 A, 20...500 Hz
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40/60 VAC/VDC
  • Protection class: IP65
  • Input (single option): 0...100 V, ±100 V, 0...400 V, ±400 V
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65
  • Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
  • Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
  • Current measurement range: 0/4...20 mA; ±20 mA (DC)
  • Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Auxiliary 24 VDC output to supply transducers
  • Display: 3-color LED, 5-digit
  • Temperature compensation
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65
  • Universal input (for standard signals and temperature sensors)
  • Alarm output
  • OLED display
  • Configuration via miniUSB connector
  • Supply: 24 VDC or 230 VDC / VAC
  • IP65 protection class

Single-phase commutator – controller RP7. The device can be used or circuit commutations. Can be used for resistive and inductive loads and single-phase motor speed control. Possible control with standard analog signal.

 

Other functions:

  • Load current limiting
  • Soft start
  • Isolated inputs
  • Load current control
  • Fuse failure detection
  • Overload indication

Single-phase controller – commutator RP1. The device can be used or circuit commutations in heat element devices. Can be used for resistive and inductive loads. Possible control: pulse or standard (analog signal).

 

Other functions:

  • Load current limiting
  • Soft start
  • Initial load power setting
  • Control with an external signal
  • Load current control
  • Fuse failure detection
  • Overload indication
  • Master/slave output
  • Switch output

Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.

  • Data visualization in WWW server
  • Convenient login from various devices (PC, tablet, phone)
  • Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
  • 1 GB Flash memory
  • E-mail messages in case of alarm occurrence
  • 2 alarm outputs or 2 binary inputs
  • RS-232, RS-485, USB, Ethernet, RTC
  • Long-life MOS or electrochemical gas sensor
  • Range 0....1000 ppm NH3
  • Resolution 1 ppm NH3
  • Outputs 4...20 mA / 0...10 V, RS-485
  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Long-life MOS sensor
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...2,5 % vol.) C2H2
  • Resolution 0,1 % LEL (25 ppm) C2H2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor

Regulator RE22 is designed to control furnace, dryer, cast machine and other devices’ temperature.

Temperature regulator RE72 for ladder control, designed for temperature stabilization in plastics and food industries.

 

  • Universal measurement input
  • Auxiliary measurement input 0/4...20 mA
  • Binary input
  • Ladder temperature control, 15 programs with 15 intervals
  • Soft start
  • ON/OFF, PID, PID step-by-step (step valve control) or PID heating – cooling
  • 8 alarm types, alarm control
  • Timer function
  • Front panel protection class IP65
  • Backside protection class IP20

Process regulator RE82 is designed for temperature stabilization in plastics and food industry.

Humidity and temperature regulator AR247 is designed for temperature and humidity control. The device is made with either integrated or cable-connected sensor. Protection class is IP65. Optionally can be ordered: RS-232 or RS-485 ports, analog output 0/4...20 mA or 0...10 VDC (for control or signal transmission).

  • Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
  • PID or ON/OFF control
  • Automatic selection of PID parameters
  • One relay output and one alarm relay
  • Manual control mode
  • One binary input
  • Operating temperature: 0...50 °C
  • Supply: 230 VAC
  • Protection class: front IP65, back IP20

Regulator RE55 is designed to control temperature in food and chemistry industry.

Temperature regulator RE71 is designed for fixed range and sensor. Input type is selected while ordering. Control: ON/OFF, PID, PID+Autotuning, Smart PID.

Temperature regulator RE81 for fixed range and sensor, with 2 switch or SSR outputs, designed for control in heating, conditioning systems. Function for 3-position control. Control: ON/OFF, PID, PID+Autotuning, Smart PID and 3-position. Input type selected when ordering.

Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.

 

Technical specifications

  • One or more level control
  • Switch output 2A, 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)

Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.

 

Technical specifications

  • One or more level control
  • Switch outputs: switching + NO 2 A / 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • One or more level control
  • Switch outputs: switching + 3 x NO 2 A / 250 VAC
  • Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC
  • One or two level control
  • Switch outputs – switching + 5 x NO, 2A / 250 VAC
  • Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – filling, draining, dry flow, overflow, two/three pump control and others
  • Valve or gate control
  • Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
  • Mounted on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC
  • System consists of alarm device SET-1000 and fixed level vibration sensor SET/V
  • For usage separators, basins and tanks
  • Alarm device SET-1000 is a single-channel level switch
  • When used with SET/V, SET-1000 alarms when set high level in tank is exceeded
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz

Counter ALC77-C for linear and rotary encoders (up/down).

 

Technical specifications

  • 600 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs + RS-232
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC77-T for linear and rotary encoders (for tachometers).

 

Technical specifications

  • 5 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC77-B for linear and rotary encoders (batch).

 

Technical specifications

  • 10 kHz input frequency
  • Encoder input (A and B signals)
  • 7-digit LED screen
  • Range -999...9999
  • 2 programmable set points (SPs)
  • 2 switch outputs
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 72 x 72 mm

Counter ALC94UNI for linear and rotary encoders (up/down), universal.

 

Technical specifications

  • 600 kHz input frequency
  • Encoder input
  • 6-digit LED screen
  • Range -99999...999999
  • 2 programmable set points (SPs)
  • 2 switch outputs OR RS-232
  • Protection class IP65
  • Supply 24 VAC/VDC or 230 VAC
  • Sensor supply 5 VDC or 12 VDC
  • Size 96 x 48 mm
  • Modern, simple and user-friendly service
  • Communication interfaces: RS-485 Modbus Slave, Modbus TCP Slave and optionally Ethernet
  • FTP server (available in controller versions with Ethernet interface)
  • Selection of PID parameters for any unit
  • For easy programming and devices configuration, LUMEL offers one common LPCon software
  • Parameter logging on SD card

General purpose regulator AR630 is designed for usage in humid or dusty environment (IP65). RS-232, RS-485 or analog ports are optional. Two programmable inputs (for temperature sensors and DC). Settings are protected by password. Set point blocking. Manual output control. Modification AR632 has two indicators (for set point (SP) and process value (PV)).

General purpose regulator with one programmable input and 2 or 3 outputs. Variant with RS-485 is used for work in measuring systems. Programmable binary input for remote work mode modification. PID autotuning. Free software for configuration. Manual control feature.

  • Universal measuring inputs, it can be used for controlling of temperature (RTD, thermocouple) and other physical values
  • Colored TFT display presentation of measured values (numerical values, bar graph, meter, graph)
  • Control algorithms On-Off; PID; 12 segmental adjustment program
  • Interfaces: USB, RS485 (MODBUS-RTU) and Ethernet (100Base-T, TCP / IP protocols: Modbus-TCP, HTTP, SMTP)
  • Internal webserver, information about the active channel, measuring parameters and the status of the regulation, requires access
  • Available alarm sound and visual, status outputs and alarm notification e-mail
  • Write data in a standard text file located in the internal controller memory (4GB) FAT with the possibility of editing in spreadsheets such as Microsoft Excel
  • Selection of PID parameters for each output
  • The possibility of creating inter-channel type mathematical and logical operations: the difference, average, sum, bigger, smaller measurement
  • Function digital inputs (BIN) to changes modes associated outputs, retransmission of measurements
  • Free software for data processing and device programming
  • Controller is destined to control the temperature and other physical quantities like pressure, humidity, level
  • Three optional outputs (0/4...20 mA ± 0,2 %, 0...10 V ± 0,2 %, 0/5 V, relay voltage output)
  • Universal input for RTDs, thermocouples and analog signals
  • Configuration parameters via keys or an optional RS-485 Modbus and free eCon software
  • The controller has three alarms, which can be assigned to each output
  • The output signals are galvanic isolated from the input signals and power supply
  • Selection of PID parameters for any unit, or auto-tuning
  • Protection class from frontal side: IP30, from terminal side: IP20
Loading...