Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.
- Material of float: stainless steel AISI 316 SS
- Max. temperature: -30...+105 °C
- Switch rating: 50 VA
- Switching voltage: 230 AC / DC
Horizontal stainless steel float level sensor LB-1. Technical specificationsHousing: side;Material of float: stainless steel AISI 316 SS;Process connection: 1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC; LB datasheet [EN]
..
Horizontal stainless steel float level sensor LB-2. Technical specificationsHousing: side;Material of float: stainless steel AISI 316 SS;Process connection: 1/2 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC; LB datasheet [EN]
..
The AUREGIS LJ-VD4M12 multi-zone floating, stainless steel level relay with standard M12 connector is designed for liquid level measurement and regulation.
- Connection connector: M12 (4 / 8 pins)
- Floats and float holders are customizable (on request)
- Connection thread: G3/4" or larger (on request)
- Switching power: 25 VA
- Switching voltage: 24 V AC/DC
- Process part operating temperature: -30...+105 °C
- Process part: Stainless steel AISI316L
- Protection class: IP65
Vertical stainless steel float level sensor LB-3. Technical specificationsHousing: top;Material of float: stainless steel AISI 316 SS;Process connection: 1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC; LB datasheet [EN]
..
Vertical stainless steel float level sensor LB-4. Technical specificationsHousing: side, 90° angle;Material of float: stainless steel AISI 316 SS;Process connection: 1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC; LB datasheet [EN]
..
Vertical float level sensor LV for fluid tank monitoring, automation, testing, measuring and control devices. Technical specifications
Switching power
≤ 10 W
Switching voltage
≤ 200 V
Switching current
≤ 0,5 A
Ambient temperature
-20...90 ºC
Casing material
PP (polypropylene) for water and weak acid devices LV datasheet [LT]
..
Horizontal float level sensor LH, designed for fluid tank monitoring, usage in automation, testing, measuring and control devices.
Switching power
≤ 10 W
Switching voltage
≤ 200 V AC/DC
Switching current
≤ 0,5 A AC/DC
Ambient temperature
-20...90 ºC
Casing material
PP (polypropylene) for water and weak acid devices More information PDF [LT]
..
- Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
- Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Multipoint float level switches LJ-VDT for fluid level measurement and control
- Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Float level switches AUREGIS LJ-V with an extension for level control
- Operating temperature: -30...+130°C
- Protection class: IP65
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
- Double water- and air-resistant sealant increases protection against infiltration even more
- Weight: 1050 g; Buoy volume: 990 cm3; Maximum pressure: < 2 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached.
- Weight: 163 g; Buoy volume: 280 cm3: Maximum pressure:< 1 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
- Double water- and air-resistant sealant increases protection against infiltration even more
- Weight: 250 g; Buoy volume: 430 cm3; Maximum pressure: < 1 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Boasts for great reliability and small size
- Weight: 111 g; Buoy volume: 225 cm3; Maximum pressure: < 2 bar / < 5 bar