- Pressure transmitter ATM/F (hygienic)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...100 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Pressure transmitter ATM/F/Ex (hygienic, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Certificates: ATEX, EAC
- Pressure range: from 0...0,1 to 0...40 bar
- Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
- Process temperature: -25...+125 °C
- Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
- Applications: Machine tools, hydraulics, water treatment
- Protection class: IP65, IP67, IP68
- Certificates Ex ATEX and IECEx
- Ex-zones 0, 1, 2 (gas), 20, 21, 22 (dust) and mining
- High reliability and safety
- Extraordinary long-term parameter stability
- Range:
- from 0...0.4 bar to 0...2000 bar
- standard 0...0.4 bar to 0...250 bar
- accuracy: ± 0.2% of range
- Process connection: G1/4"
- Output: 4...20 mA
- Process temperature: -40°C...+120°C
- Ambient temperature: -40°C...+120°C
- Supply: 10...30 VDC
- Protection class: IP65
- Casing material: stainless steel 1.4452 (AISI630)/ 1.4301 (AISI304)
- Pressure range: from 0...6 to 0...600 bar
- Output signal: 4...20 mA / 1 x PNP / 2 x PNP
- Process temperature: -40...+125 °C
- Accuracy: 0,3 %
- Dielectric strength: 710 V
- Measurement principle: thin film on steel
- Protection class: IP65, IP67
- Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
- Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
- Pressure transmitter PTM (programmable)
- Various pressure measurement ranges: 0,1...1000 bar
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Various pressure measurement ranges: 0,1...1000 bar
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, EAC
- Various pressure measurement ranges: 0,1...1000 bar
- Temperature measurement range: -25...85 °C
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 2 x 4...20 mA
- Digital output: RS-485
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Various pressure measurement ranges: 0,1...1000 bar
- Relay output: 2 units
- Output: 0...20 mA / 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Measuring function: differential pressure, volume flow
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
- Allowed overpressure: 50 kPA
- Supply: 24 VAC
- Medium: clear air, non-aggressive, non-combustible gases
- Protection class: IP 54
- Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
- Webserver
- Functional Block programming software
- LED signaling for Link/Act Ethernet, serial RX-TX, power supply
- Configurable by the software DEV9K
- Galvanic isolation on all the ways (1500 VAC)
- Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
- Webserver
- Functional Block programming software
- LED signaling for Link/Act Ethernet, serial RX-TX, power supply, digital inputs and digital outputs state
- Configurable by the software DEV9K
- Capable to connect the sensors to the analog inputs
- Galvanic isolation on all the ways (1500 VAC)
- Supports devices: NAT 8252, NAH 8254, NAR 8258, ECL 8439
- Fast and easy operation via Android app “Sensor Master Communicator SMC”
- Read out of sensor data
- Parametrization of switich points on NAx pressure switches
- Measuring range adjustment on submersible pressure transmitter ECL
- Reset pressure measurement instruments to factory settings
- Ambient temperature: 0...40 °C
- Supply: 5 V (USB)
- Communication: Bluetooth Low Energy
Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.
- The MQTT protocol is ideal for communication in distributed acquisition systems data (IoT applications)
- Data visualization in WWW server
- Convenient login from various devices (PC, tablet, phone)
- Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
- 8 GB Flash memory
- Real time clock (RTC)
- 2 alarm outputs or 2 binary inputs
- RS-232, RS-485, USB, Ethernet
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- MOS gas sensor
- Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
- Standard calibration: R-404a
- Range: 0...1000 ppm HFC
- Resolution: 1 ppm HFC
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+60 °C
- Supply: 11..30 VDC / 24 VAC arba 90...265 VAC
- Ethernet connection
- Digital inputs: 2
- 1-Wire input (up to 2 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- Webserver
- HTTP and XML API commands
- E-mail alarms, SMTP, SNMP
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
The PD9W is an industrial RS-232 / RS-485 to WiFi and Ethernet converter.
- Communication interfaces: 1x RS485, 1 x RS232, 1x Ethernet and WiFi (802.11b/g/n)
- Modes: AP, STA, AP + STA, AP + LAN, AP + WAN, Route and Bridge
- Work modes: transparent transmission mode, serial port command mode, HTTP Client mode, Modbus TCP<=>Modbus RTU mode and AT command mode
- Configuration the parameters via the WEB server
- RS232 port for RTS/CTS signals
- Hardware Watchdog, Heartbeat
- Electrostatic protection 15 / 8 kV
- Power supply: 5…36 V dc
PD9-Modbus RS485 to Ethernet converter can realize bidirectional transparent transmission between RS485 and Ethernet. It carries ARM processor, low power, fast speed, high stability. Via web-page or software, Rs-485 to Ethernet Converter can realize serial data and TCP/IP data package transparent transmission.
- Communication interfaces: 1x RS485, 1x Ethernet WAN/LAN
- Easy configuration the parameters via the webpage or set-up software
- Compact size, DIN rail mount
- Working mode: TCP server, TCP client, UDP server, UDP client
- Modbus RTU to TCP conversion, Modbus Polling
- DHCP support, IP dynamic or static
- Watchdog function
- Working temperature: -40…85°C
- Power supply: 5…36 V dc
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
- The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- With integrated K type thermocouple
- Accuracy: 1 %
- Coefficient: 0,84 ± 0,01
- Static pressure: Atmospheric
- Temperature of use: 0…1000 °C
- Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
- Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
- 2000 VAC galvanic isolation
- High accuracy
- EMC compliance - CE symbol
- Mounting on DIN rail - EN-50022 complience
- Supply voltage: 10...30 VDC
- Ambient temperature: -10...+60°C
- Signal splitter DAT5022
- Configurable with switches on body
- 3-way galvanic isolation (2000 VAC)
- Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
- Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
- Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
- Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
- Environment: -20...+70 °C / (non-condensing) 0-90%
- Housing: Self-extinguishing material
- EMC
- Immunity: EN 61000-6-2
- Emission: EN 61000-6-4
- Ethernet 10/100 Base-T Modbus TCP interface (RJ-45 connector)
- Configurable using webserver
- RS-485 (Modbus RTU Master)
- Distance up to 1200 m, up to 32 modules
- LED indication
- Galvanic isolation in all ways (1500 VAC)
- EMC compliance
- Mounting on DIN rail - EN-50022 compliance
- Modbus Slave over RS-485
- Modbus RTU / Modbus ASCII protocols
- Communication parameters configurable by dip-switches
- Watch-dog alarm
- Remotely configurable
- 3-way galvanic isolation (1500 VAC)
- High accuracy
- Mounting on DIN rail - EN-50022 compliance
- Ethernet 10/100 Base-T interface
- Modbus TCP server
- Webserver for configuration of device and representation of actual input values
- Galvanic isolation on all the ways (1500 VAC)
- Remotely configured
- LED indication
- EMC compliance
- DIN rail mounting
- Stable long-life electrochemical cell
- Range 0...50 / 0...2000 ppm SO2
- Resolution < 0,1 / 1,5 ppm SO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 2 / 5 ppm SO2
- Attached or remote sensor
- Stable long-life electrochemical cell
- Range 0...50 / 0...2000 ppm SO2
- Resolution 0,1 / 1,5 ppm SO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...50 ppm SO2 / 0...2000 ppm SO2
- Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11..30 VDC / 24 VAC or 90...265
- Patented quality product (immersion sensor patent)
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: 0 – 10 V or 4...20 mA
- Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
- Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
- Medium: in liquid or gaseous media
- For aggressive media, stainless steel immersion sleeves must be used
- Ambient temperature: -30…+70 ºC
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-1 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-4 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-S is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Operates as a temperature switch (thermostat), transducer, data logger
- Accumulated temperature data is read using a mobile phone with NFC interface
- Parametrization via NFC interface
- Display and electrical connection are independently rotatable 335°/343°
- Temperature measurement range: -50...+150 °C
- Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
- Switch output: 2 x PNP
- Sensor: Pt1000 A
- Data logger memory: 3518 measurement points
- Measurement interval: 0,1...999,9 s
- Operating temperature: -25...+85 °C
- Supply: 15...30 VDC
- Temperature transmitter 5331A with 4...20 mA output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5333A with 4...20 mA output, designed for RTD signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334A with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334B for explosive Ex atmosphere with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
Temperature transmitter DAT1010 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm) ir voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1015 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1066 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA). With galvanic isoliation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
- Input (configurable): TC, RTD, mV, resistance and potentiometer
- Output: Modbus RTU / ASCII Slave device over RS-485
- 1500 Vac 3-ways Galvanic Isolation
- High accuracy
- Remotely configurable over RS-485
- EMC compliance (CE mark)
- Mounting in B-type head
- Easy implementation in existing PLCs and SCADA systems
- Operating temperature: -40...+85°C
- Supply voltage: 18...30 VDC
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.
Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.