- Fully functional data logger
- Two-line digital LCD display
- 4 control buttons
- 32 alarm LEDs
System of data logging MS6D, MS6R (Comet System, Czech Republic). For mounting to 19" rack - one rack unit 1U. The device can be integrated into the MP033, MP034 waterproof housing. With backlight display, 4 control buttons (for configuration), 32 LED for alarm.
- Universal datalogger with 4 hardware MiniDIN inputs for connecting temperature and humidity probes.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 hardware MiniDIN inputs for thermocouples K, J, S, B, T, N.
- Cold junction compensation (CJC).
- Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Thermocouples are ordered separately.
- Open collector transistor alarm output.
- Universal datalogger with 4 hardware MiniDIN inputs, 2 for thermocouples K, J, S, B, T, N and 2 for connecting temperature and humidity probes.
- Cold junction compensation (CJC).
- Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures barometric pressure using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
Data logger PD22. The device is designed for usage in telemetric systems, to be located between a controller and slave devices. PD22 increases the data transfer speed and enables the system to contain more devices. Slave devices are connected to the RS-485 port (Port.1, MODBUS). System controller is connected to RS-485 or RS-232 (Port.2). Data logger has a real time clock and is mounted on 35 mm rail.
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
- Free software for configuration and data visualization
- Bluetooth communication for smartphones and tablets (Android and IOS)
- Safety lock magnetic mounting with inviolability system holder (accessories)
- Compatible with food industry environment
- Up to 4 recordable parameters simultaneously
- Optional calibration certificate
- Data visualization in WWW server
- Convenient login from various devices (PC, tablet, phone)
- Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
- 1 GB Flash memory
- E-mail messages in case of alarm occurrence
- 2 alarm outputs or 2 binary inputs
- RS-232, RS-485, USB, Ethernet, RTC
- Portable analyzer NP40 is designed for power network quality parameter analysis
- Analyses voltage and current harmonics up to 51-st, THD
- Real-time waveform display (4 voltage / 4 current)
- Measurement of TRMS currents up to 3000 A (with standard sensor)
- Half cycle RMS measurement (voltage and current)
- Measurement in 1-phase and 3-phase systems (3- and 4-wire)
- Voltage, current, harmonics, power, energy and other parameter measurement
- Graphical representation of data in a waveform and vector diagram
- Record of events: dips, swells, overvoltages
- Built-in 8 GB memory card
- Ethernet interface for remote monitoring
- USB interface for data transfer
- Color 5,6” TFT display, 320 x 240 px
DPC 8380 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.
DPS 8381 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.
- Range: 0...2,5 iki 0...600 bar / 0...30 iki 0...7500 psi
- Sensor type: Thick film on steel
- Accuracy: ±0,5 %
- Output (chosen): 4...20 mA / 0...5 VDC / 0...10 VDC / 1...6 VDC
- Switching outputs: 2 x PNP
- Shown measuring units: bar, psi, MPa, kPa, m WC, mm WC
- Ambient temperature: -25...+85 °C
- Media temperature: -25...+85 °C
- Protection class: IP65
- Process connection: G1/4" m, R1/4" m, 1/4"NPT m, 1/2"NPT m
- Data logger memory: 3518 points
- Measurement channels: up to 24
- Analog inputs: 12
- Relay outputs: 6 or 32
- Analog outputs: 4 or 8
- Digital outputs: RS-232, RS-485, USB
- Screen: touchscreen LCD TFT 5.7”
- Memory: CompactFlash memory card, up to 4 GB
- Visualization of measurements in digital form, analog indicators, diagrams, bargraphs
- Ethernet, Webserver, FTP server, Modbus Slave TCP/IP
- Diversified users’ access rights
- PC software
- Protection class: IP65 (front)
- Operating temperature: 0...55 °C
- Supply: 230 VAC
- Digital data logger KD8 with a colored touchscreen LCD display
- The device is designed for measurement and logging of parameters in industry, energy sector, control and monitoring systems
- Software for data analysis in PC
- 4-language menu, electronic signature for data protection
- Digital multimeter with data logging view function (up to 32000 readings)
- Four versions: NP15-2, NP15-3, NP15-5, NP15-6 TRMS (see datasheet below)
- TRMS measurement
- Low input impedance
- Capacity measurement from 1 pF to 40 mF
- AC and DC voltage measurement up to 1000 V
- AC and DC current measurement up to 10 A
- Resistance measurement
- Frequency measurement
- Diode measurement and continuity testing
- Filtering
- Square wave signal generator
- Hold function, backlight, maximal and minimal value presentation
- External supply
- Duty cycle (%) measurement
- Temperature measurement (K, J type thermocouples, Pt100 and Pt1000)
- Automatic / manual range selection
- USB connectivity (optional)