System of data logging MS6D, MS6R (Comet System, Czech Republic). For mounting to 19" rack - one rack unit 1U. The device can be integrated into the MP033, MP034 waterproof housing. With backlight display, 4 control buttons (for configuration), 32 LED for alarm. 

 

TECHNICAL SPECIFICATIONS

Memory type:

Internal SRAM

Memory capacity:

2MB (up to 480 000 values)

Data logging modes:

noncyclic - logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new

Data logging interval:

adjustable individually for all input channels from 1 second to 24 hours

Interface:

RS232(RxD,TxD,RTS,CTS), USB, RS485, Ethernet(SNMP, SOAP)

Communication speed:

9600, 19200, 57600, 115200 bods

Alarm indication:

Red LED indication
Relay max. 8A/250V ac
Voltage signal 0V/4.8V, max. current 50mA
Messages could be sent via e-mail, SNMP, SMS

Supply:

24 Vdc

Operating storage temperature:

0…+50°C

Dimension with connectors (MS6D):

215 x 225 x 44 mm (W x H x D)

Dimension with connectors (MS6R):

483 x 230 x 44 mm (W x H x D) rack 1U 

Dimension without rack holder (MS6R):

225 x 230 x 44 mm (W x H x D)

Protection class:

IP20

 

Configurable input parameters

Measuring value

Accuracy

Description

dc current 4...20mA
dc voltage -10...+10V

±0.1% FS (±0.02mA)

(±10 mV) input resistance approximately 10 Mohms,
input terminals IN and COM

dc voltage -1...1V

±0.1% FS (±10mV)

input resistance approximately 10 Mohms,
input terminals IN and COM

dc voltage -100mV...+100mV

±0.1% FS (±1mV)

input resistance approximately 10 Mohms,
input terminals IN and COM

dc voltage -18...+18mV

±0.1% FS (±100μV)

input resistance approximately 10 Mohms,
input terminals IN and COM

Thermocouple K (NiCr-Ni)

±0.1% FS (±18μV)

linearized, cold junction compensation,
input terminals IN and COM

-200...1300°C
Thermocouple J (Fe-Co)

±0.3% ~ 1.5°C
reading error

linearized, cold junction compensation,
input terminals IN and COM

-200...750°C
Thermocouple S (Pt10%Rh-Pt)

±0.3% ~ 1.5°C
reading error

linearized, cold junction compensation,
input terminals IN and COM

0...1700°C
Thermocouple B (Pt30%Rh-Pt)

±0.3% ~ 1.5°C
reading error

linearized,without cold junction compensation,input terminals IN and COM

100...1800°C
Thermocouple T(Cu-CuNi)

±0.3% ~ 1°C
reading error
300…1800°C range

linearized, cold junction compensation,
input terminals IN and COM

-200...400°C
Platinum RTD sensor Pt100

±0.3% ~1.5°C
reading error

two-wire connection, measuring current approximately 0.8mA in pulse 50ms,
input terminals IN and COM

-200...600°C
Platinum RTD sensor Pt1000

±0.2°C (-200…100)°C range
±0.2% (100…600)°C range

two-wire connection, measuring current approximately 0.5mA in pulse 50ms,
input terminals IN and COM

-200...600°C
Nickel RTD sensor Ni1000

±0.2°C (-200…100)°C range
±0.2% (100…600)°C range

two-wire connection, measuring current approximately 0.5mA in pulse 50ms,
input terminals IN and COM

0...300Ω
Via 2-wiring interface measuring resistance.

0.1% FS (±0.3Ω)

measuring current approximately 0.8mA / 50ms,
input terminals IN and COM

0...3000Ω
Via 2-wiring interface measuring resistance.

0.1% FS (±3Ω)

measuring current approximately 0.5mA / 50ms,
input terminals IN and COM

0...10000Ω

0.1% FS (±10Ω)

measuring current approximately 0.1mA / 50ms,
input terminals IN and COM

Binary inputs (for two-states signals)

input voltage for state "L" (IN-COM) < 0.8 V (Rin < 1 kOhm).
resistance of closed contact for state "L" (IN-COM) < 1 kOhm.
input voltage for state "H" (IN-COM) > 2 V.
resistance of closed contact for state "H" (IN-COM) > 10 kOhm.
minimum duration for sensing of change: 200ms.

RS485IN

E.g. data acquisition from temperature, humidity, pressure sensors Tx41x, Hx43x.
input serves for reading from devices supporting protocol ModBus RTU or Advantech.
Connected to terminals next to terminals for channel 15 and 16.
Input can work with 16 devices.
Maximum speed 115200Bd.
Galvanically isolated.

 

MS6D monitoring system with data logger‘s description on Comet System website [EN]

MS6D description [EN]