Ничего не куплено!
- Temperature measurement range: 0...+50 °C
- Humidity measurement range: 0...85 %
- Pressure measurement range: 300...1100 hPa
- CO2 concentration measurement range: 0...9999 ppm
- Operational range (in line-of-sight): up to 10 m (Bluetooth Low Energy)
- Data is sent to smartphone (Android, iOS), no need for special receiver
- Data transmission: 1, 2, 5, 10 min
- Aranet4 anti-theft wall mount is available
- Data encryption
- Supply: 2 x AA batteries
- Battery lifetime (20 °C): up to 2 years
- Operating temperature: 0...+50 °C
- Protection class: IP20
- Temperature measurement range: 0...+50 °C
- Humidity measurement range: 0...85 %
- Pressure measurement range: 300...1100 hPa
- CO2 concentration measurement range: 0...9999 ppm
- Operational range (in line-of-sight): up to 3 km
- Bluetooth Low Energy operational range for direct connection with smartphone (Android or iOS): up to 10 m
- Data transmission: 1, 2, 5, 10 min
- Aranet4 anti-theft wall mount is available
- Data encryption
- Supply: 2 x AA batteries
- Battery lifetime (20 °C): up to 2 years
- Operating temperature: 0...+50 °C
- Protection class: IP20
- CO2 concentration measurement range: 0...10 000 ppm
- Output: 4...20 mA
- Programmable
- External probe cable length: 1 / 2 / 4 m
- LCD display
- Calibration certificate included
- Ambient temperature: -30...+80 °C
- Supply: 9...30 VDC
- Protection class: IP65
- Warranty: 3 years
- SF6 gas monitor for high and medium voltage switchgear
- Measurement range: 0...60 kg SF6/m3
- Output signal: current pulses onto supply current, current loop
- Media temperature: -40...+70 °C
- Protection class: IP65
- Shock proof, suitable for outdoor usage, compact
- SF6 gas monitor for high voltage switchgear
- Four versions: 1 / 2 / 3 / 4 stages (8716 / 8726/ 8736 / 8746)
- Measurement range: 0...1.1 MPa
- Output signal: floating change-over contact (SPDT)
- Switch point: factory calibrated
- Media temperature: -40...+80 °C
- Protection class: IP67
- Independent, galvanically separated circuits
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Stable long-life metal-oxide gas sensor
- Range 0....1000 ppm NH3
- Resolution 1 ppm NH3
- Default alarms at 25 ppm / 35 ppm NH3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Electrochemical gas sensor
- Range: 0...100, 0...300, 0...1000, (0...10000 on request) ppm NH3
- Resolution: 1 / 2 / 5 ppm NH3
- Sensor lifetime: > 2 years
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -10...+50 °C
- Supply: 11..30 VDC / 24 VAC or 90...265 VAC
- Metal-oxide gas sensor
- Range: 0...1000 ppm NH3
- Resolution: 1 ppm NH3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C / 15...90 %RH
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- NDIR gas sensor
- Range: 0...50 000 ppm CO2 (up to 100 % CO2 on request)
- Resolution: 0.01 % vol.
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -25…+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Electrochemical (CO) and optical NDIR (CO2) gas sensors
- Range: 0...100 ppm CO, 0...10000 ppm CO2
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Electrochemical gas sensors
- Range: 0...100 ppm CO, 0...20 ppm NO2
- Resolution: 1 ppm CO, 0,1 NO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Operating temperature: -20...+50 °C
- Supply: 24 VDC/VAC
- Protection class: IP65
- Photo ionization detector
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: isobutylene
- Range: 0...40 / 0...200 ppm (isobutylene)
- Resolution: 1 / 1 ppb
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+65 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Metal-oxide gas sensor
- Detected vapors: acetone, ethanol, toluene, xylene, etc.
- Standard calibration: toluene
- Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
- Resolution: 0,1 % LEL / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,3 / 1 ppm O3
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...5 ppm O3
- Resolution: 0,01 ppm O3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
The oxygen concentration meter MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 °C.
- SF6 gas density monitor for high voltage switchgear
- Three versions: 1 / 2 / 3 stages (8781 / 8782 / 8783)
- Measurement range: 0...1,1 MPa (mechanical), 0...0,85 MPa (electronic)
- Output signal: floating change-over contact (SPDT) / 6.5...20 mA current loop
- Switch point: factory calibrated
- Media temperature: -40...+80 °C
- Ambient temperature: -40...+80 °C
- Protection class: IP65
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- Pressure measurement range: 600...1100 hPa
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Long-life MOS or electrochemical gas sensor
- Range 0....1000 ppm NH3
- Resolution 1 ppm NH3
- Outputs 4...20 mA / 0...10 V, RS-485
- To measure carbon dioxide in air and neutral gases range 0…5000 ppm
- Configuration with switches or software: measuring ranges, outputs settings
- Optional with display or without display
- Ambient and duct models. Duct model available only without display
- To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
- Configuration with keypad or software: measuring ranges, units, outputs settings
- Optional with display or without display
- Galvanic isolation all the ways
- On request range increase up to 0...20 000 ppm
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Long-life MOS sensor
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...2,5 % vol.) C2H2
- Resolution 0,1 % LEL (25 ppm) C2H2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor