This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Измерения и регулирования газов

Измерения и регулирования газов
Показать:
Сортировка:
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...25 % vol O2
  • Resolution: 0,01 % vol O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector (PID) sensor
  • Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
  • Default calibration: Isobutylene
  • Range: 0…40 / 0…200 ppm isobutylene
  • Resolution: 0,01 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Detectable gases: acetone, ethanol, toluene, xylene etc.
  • Default calibration: toluene
  • Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
  • Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
  • Detectable gases: O2, CO, CO2, NO, NOx
  • Up to three gas sensors
  • CO measurement up to 8000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
  • Color display screen with buttons
  • Communication: Bluetooth (mobile App), remote printer
  • Measurement storage: smartphone
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping
  • Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
  • Flexible control: 3 relays (SPDT, potential-free, 250 V)
  • Intelligent Communication: RS-485 interface with DGC and Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
  • Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
  • Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
  • Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
  • Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensor
  • GSM modem (GPRS)
  • SMS and JSON messages can be sent via GPRS data connection
  • Messages can be sent on alarms and periodically
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate of manufacturer included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years
  • Long-life metal-oxide gas sensor
  • Range 0...100 % LEL H2
  • Resolution 0,1 % LEL H2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Hydrogen pressure transmitter’s measuring principle: Thin-film-on-steel
  • EC79 and ECER-134 certification pending (see product website for current situation)
  • Applications: Fuel cells, fueling stations, hydrogen compressors, hydrogen tanks, vehicles with H drive
  • Measuring range: 0…1050 bar / 0…15000 psi *(see product datasheet)
  • Measuring accuracy at 25 °C typ.: ± 0.3 / 0.5 % FS typ.
  • Output signal: 4...20 mA, 0.5...4.5 VDC, 0...5 VDC, 1...5 VDC, 1...6 VDC, 0...10 VDC, 0.1...10.1 VDC, 0.5...4.5 VDC ratiometric, Switching output: 1 or 2 PNP
  • Pressure connections: G1/4" m, 1/4"NPT m, 7/16"-20UNF SAE4 m
  • Ambient temperature: 40°C…+85°C
  • Stable long-life electrochemical gas sensor
  • Range 0...100 / 0...1000 ppm H2S
  • Resolution 0,1 / 1 ppm H2S
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 10 / 20 ppm H2S
  • Stable long-life electrochemical gas sensor
  • Range 0...100 / 0...1000 ppm H2S
  • Resolution 0,1 / 1 ppm H2S
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor option
  • Electrochemical gas sensor
  • Range: 0...100 / 0...2000 ppm H2S
  • Resolution: 0,1 / 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Applications of flue gas analyzer Si-Ca 230: boilers, burners, water heaters, gas and diesel engines, furnaces, industrial kilns, industrial heating systems, incinerators
  • Detectable gases: O2, CO (H2 comp.), CO2, NO, Low NO, NO2, Low NO2, NOx, Low NOx, SO2, Low SO2, CxHy (HC), H2S
  • Up to six gas sensors
  • CO measurement up to 50 000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation), stack gas velocity
  • Color graphical touchscreen for control
  • Communication: USB, Bluetooth (mobile App), remote printer
  • Measurement storage: 2000 data points + smartphone and PC
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping

The new leak meters LD 500/510 with integrated camera and leakage calculation are ideal to find even smallest leakages (0.1 l/min) easily even in far distances and calculate potential saving (€/year).

  • 30 MEMS digital microphones for image of leaks
  • Measuring distance: up to 6,5 m
  • 3,5” TFT color display with touch panel
  • Additional sensor input to measure: dew point, flow, pressure, and temperature (LD 510 only. See datasheet)
  • Possibility to take photo of leaking parts
  • Data transfer via USB to PC
  • Easy data and work assignment with CS Leak Reporter cloud solution
  • ISO 50001 report
  • Power supply: 7,2 V lithium-ion battery (> 9 h continuous operation)
  • Operating temperature: -5…+40 °C

The enLink OAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (1.0, 2.5, 4.0 & 10), Barometric pressure, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • Power supply: 12…24V V DC, 0.15 Amp (max) / 4 x Li-SOCl2 (3.6V) AA / external solar panel
  • Configuration via USB cable / downlink
  • IP rating: IP42 (conformally coated electronics), do not expose to direct sunlight
  • Operating Temp. / Humidity: -10…40 °C / 0…95 % RH (be kondensacijos)
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...5 % vol) CH4
  • Resolution 0,1 % LEL (50 ppm) CH4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 / 50 % LEL CH4
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL CH4
  • Resolution 0,1 % LEL CH4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 / 50 % LEL CH4
  • Visual and acoustic alarms
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...5 % vol) CH4
  • Resolution 0,1 % LEL (50 ppm) CH4
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Metal-oxide gas sensor
  • Range: 0...100% LEL (0...5 %) CH4
  • Resolution: 0,1 % LEL (50 ppm) CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

TSM400-4-CP is a multi parameters sensor that supports MODBUS RTU protocol over the RS-485 interface. The sensor measures barometric pressure and CO2 concentration.. Suitable for environmental quality monitoring, indoor air, smart ventilation systems, restaurants and breweries CO2 level and CO2 leakage control.

  • Changeable bitrate and other communication parameters
  • Non-volatile memory for all setting
  • CO2 measurements range: 400…5000 ppm
    • Accuracy: ± (40 ppm + 5 %)
    • Resolution: 1 ppm
    • Calibration: Automatic, if the sensor is exposed to fresh air for more than 30 minutes
  • Pressure measurements range: 10…1200 hPa
    • Accuracy (min): ±1.5 (25°C, 750 hPa)
    • Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
    • Resolution: 1 hPa
  • Operating temperature range: -20…+60°C
  • Operating relative humidity range: 5…95% (non-condensing)
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC

SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.

  • Measuring elements:
    • CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
    • VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
    • PM: Laser-based light scattering particle sensing
    • Temperature: Integrated to CMOS
    • Relative humidity: Thermoset polymer capacitive sensing element
  • Field configurable outputs for selected measurements; Configuration possible through MODBUS
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
  • Optional LCD-display and buttons
  • Operating temperature: 0…50 °C
  • Protection standard: IP20
  • Electrochemical gas sensor
  • Range: 0...250 ppm NO
  • Resolution: 1 ppm NO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 3 / 6 ppm NO2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range:
  • -- 0...20 ppm NO2
  • -- 0...200 ppm NO2
  • Resolution:
  • -- 0,1 ppm NO2 for 20 ppm range
  • -- 1 ppm NO2 for 200 ppm range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...20 % vol O2
  • Resolution 0,01 % vol O2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 19,5 / 18 % vol O2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 % vol O2
  • Resolution 0,01 % vol O2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Electrochemical gas sensor
  • Range: 0...25 % O2
  • Resolution: 0,01 % O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 12...36 VDC, 24 VAC or 230 VAC
  • Oxygen concentration measuring in air and inert gas mixtures
  • Specially developed for use in composting plants
  • Measuring range of oxygen concentration: 0,1…25 % (0…100 % range on request)
  • Value indicator of measured oxygen concentration
  • Output: 4…20 mA analog or bidirectional digital signal (for calibration, operation diagnostic)
  • Length and diameter of the sensor protection tube to the handle: 1200 x 30 mm
  • Length of the protective tube part to be stuck in the compost heap: ~ 1000 mm
  • Material of protective tube: Stainless steel 1.4301
  • Housing ambient temperature: -10…+50 °C
  • Probe ambient temperature: -10…+100 °C
  • Protection class of housing electronic: IP65
  • Protection class of probe: IP40
  • Rechargeable battery with indication of voltage
  • It is possible to connect the sensor to a stationary data processing system
  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • MOS gas sensor
  • Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
  • Standard calibration: R-404a
  • Range: 0...1000 ppm HFC
  • Resolution: 1 ppm HFC
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+60 °C
  • Supply: 11..30 VDC / 24 VAC arba 90...265 VAC
SF6 gas concentration control base station SF6-Network Monitor. The device manages up to 5 units of SF6-Air sensor. Warning and alarm thresholds can be set for each SF6 Air Sensor.The plug-and-play operating concept makes the handling very comfortable. Measuring values can be stored and called on the 5.7" colored touch screen, if necessary. Technical specifications Connection: max. 5 SF6 Air Sensors via bus system Indication: colored 14.5 cm (5.7") touch screen Max. length ..
SF6 gas concentration meter SF6-Air Sensor for indoor air control. The device measures small SF6 gas concentration and shows actual values. SF6-Air sensor does not use radioactive materials, so no special safety measures must be taken. Ambient humidity and other gasses do not affect the measurements. No calibration needed in all device lifespan. Reliable measurement. Alarm levels can be set according to demand. Technical specifications Sensor:  NDIR, 2 Measuring range: 0 ... 1000 ppm ..
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution < 0,1 / 1,5 ppm SO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 2 / 5 ppm SO2
  • Attached or remote sensor
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution 0,1 / 1,5 ppm SO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...50 ppm SO2 / 0...2000 ppm SO2
  • Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265
  • Simultaneous detection of two gases (please ask for available gas combinations and possible limitations)
  • Switch output: 4 x SPDT (2 for each sensor)
  • Alarms: LED indicators and buzzers (85 dB)
  • Supply: 24 VDC/VAC / 90...265 VAC
  • Protection class: IP65
  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm LEL
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Remote probe option
  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 relays with switch-over contacts
  • Default alarm set-points 10 % / 25 % LEL
  • Visual and acoustic alarms
  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL (0...1 % vol) toluene
  • Resolution 3 ppm toluene
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Acoustic alarm
  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm toluene
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • For toluene, xylene, ethanol and 2-propanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range: 0...100 % LEL or 0…500 ppm
  • Resolution 0,1 % LEL or 1 ppm
  • Outputs: 2 relays with switch-over contacts
  • Acoustic and visual alarms
  • Temperature measurement range: -20…+60 °C
  • Humidity measuring range: 0…95 % RH
  • Dew point measuring range: -60…+60 °C
  • CO2 measuring range: 0…5000 ppm
  • Atmospheric pressure measuring range: 700…1100 hPa
  • Simple sensor connection to existing WIFI network (standard: IEEE 802.11 b/g/n)
  • Measured values can be sent to the internet storage COMET Cloud or COMET Database
  • Communication protocols: HTTP(S), SMTP, Modbus TCP, SNMP (v1, v2c, v3), HTTP POST, HTTP GET (JSON, XML)
  • Alarm signalization: e-mail, acoustic, LED, SMS - additional order
  • Measuring interval: 1 s
  • Sending interval to COMET Cloud: adjustable 5 min. to 12 hours
  • Calibration certificate of manufacturer included
  • Operating temperature: -30…+60 °C
  • Supply: 5,0…5,4 VDC USB-C connector
  • Protection class: IP30

Sensor SKU: 5906660327868 (IP30)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.

  • Carbon dioxide (CO2) measurement range: 400…5000 ppm, accuracy: +/- (40 ppm + 5 % of reading)
  • Atmospheric pressure measurement range: 300…1100 hPa, accuracy: absolute +/- 3 hPa in temperature 0…+65°C, relative +/- 0,12 hPa in temperature 0…+65°C
  • Temperature measurement range: -15…+70 °C, accuracy: up to 0,4 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy 4 % in 0…80 % RH
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection

Sensor measures carbon dioxide (CO2) concentration, temperature, and atmospheric pressure. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • CO2 measurements:
    • Range: 0…9999 ppm
    • Resolution: 1 ppm
    • Accuracy: ± (30 ppm + 3 % of reading)
  • Atmospheric pressure measurements:
    • Range: 300…1100 hPa
    • Resolution: 1 hPa
    • Accuracy: +3 hPa / -2 hPa
  • Temperature measurements:
    • Range: 0…50 °C
    • Resolution: 0,1 °C
    • Accuracy: ± 0.3 °C
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply: 1 x AA battery
  • Battery lifetime (20 °C): up to 8 years
  • Operating temperature: -40…60 °C
  • Protection class: IP67

Sensor SKU: 5905309601321 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Indoor air quality IAQ measurement range: 0…500
  • Temperature measurement range: -35…+70 °C, accuracy up to 0,4 °C in the range from -20°C to +70°C and 0,5 °C in the range -35…-20 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy up to 4 % in 0…80 % RH and 7 % in the range 81…99 %
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327813 (IP30)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Indoor air quality IAQ measurement range: 0…500
  • Temperature measurement range: -15…+70 °C, accuracy: up to 0,4 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy 4 % in 0…80 % RH
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection
  • Sensor E2-VOC measures VOC (Volatile organic compounds), ambient temperature and humidity, transmits instant values, average hourly values, and average 24-hour values
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: T (C or S can be custom ordered)
    • AES-128 encryption mode 5, profile A
  • Measurement range
    • Temperature: -40…+85 °C
    • Humidity: 0…100 % RH (non condensing)
    • VOC: 0…60000 ppb
  • Measurement accuracy
    • Temperature: ± 0,2 °C in the range of +5…+55 °C
    • Humidity: ± 2 % RH in the range of 10…90 %
    • VOC: typical ± (15…25 %) of value at 25 °C / 50 % RH
  • Transmission interval: 90 s both sampling and sending. Custom sending interval on request (60 s…1 hr)
  • Device has 2 antennas for maximum range in both vertical and horizontal directions
  • Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
    • Battery lifetime up to 14 years, depends on configuration and operating temperature

Radon gas is tasteless, odorless, and hard to detect, posing serious health risks. It escapes from the ground into the air and can accumulate in your home. Radon is a radioactive element, and higher concentrations entering the lungs can cause cancer. Since its levels can fluctuate regular radon monitoring is vital.

  • Radon measurement range: 0…4000 Bq/m3
  • Temperature measurement range: 0...+50 °C
  • Humidity measurement range: 0...99 %
  • Pressure measurement range: 600...1100 hPa
  • Operational range (in line-of-sight): up to 3 km*
  • Bluetooth Low Energy connection with smartphone (Android or iOS) using Aranet Home mobile app
  • Supply: 2 x AA batteries
  • Battery lifetime (20 °C): up to 7 years (see datashet)
  • E-Ink display for longer battery life
  • Operating temperature: 0...+50 °C
  • Protection class: IP20
Loading...