Safety Sport TotoSystem of data logging MS6D, MS6R (Comet System, Czech Republic). For mounting to 19" rack - one rack unit 1U. The device can be integrated into the MP033, MP034 waterproof housing. With backlight display, 4 control buttons (for configuration), 32 LED for alarm.
TECHNICAL SPECIFICATIONS | |
Memory type: | Internal SRAM |
Memory capacity: | 2MB (up to 480 000 values) |
Data logging modes: | noncyclic - logging stops after filling the memory |
Data logging interval: | adjustable individually for all input channels from 1 second to 24 hours |
Interface: | RS232(RxD,TxD,RTS,CTS), USB, RS485, Ethernet(SNMP, SOAP) |
Communication speed: | 9600, 19200, 57600, 115200 bods |
Alarm indication: | Red LED indication |
Supply: | 24 Vdc |
Operating storage temperature: | 0…+50°C |
Dimension with connectors (MS6D): | 215 x 225 x 44 mm (W x H x D) |
Dimension with connectors (MS6R): | 483 x 230 x 44 mm (W x H x D) rack 1U |
Dimension without rack holder (MS6R): | 225 x 230 x 44 mm (W x H x D) |
Protection class: | IP20 |
Configurable input parameters | ||
Measuring value | Accuracy | Description |
dc current 4...20mA | ±0.1% FS (±0.02mA) | (±10 mV) input resistance approximately 10 Mohms, |
dc voltage -1...1V | ±0.1% FS (±10mV) | input resistance approximately 10 Mohms, |
dc voltage -100mV...+100mV | ±0.1% FS (±1mV) | input resistance approximately 10 Mohms, |
dc voltage -18...+18mV | ±0.1% FS (±100μV) | input resistance approximately 10 Mohms, |
Thermocouple K (NiCr-Ni) | ±0.1% FS (±18μV) | linearized, cold junction compensation, |
-200...1300°C | ±0.3% ~ 1.5°C | linearized, cold junction compensation, |
-200...750°C | ±0.3% ~ 1.5°C | linearized, cold junction compensation, |
0...1700°C | ±0.3% ~ 1.5°C | linearized,without cold junction compensation,input terminals IN and COM |
100...1800°C | ±0.3% ~ 1°C | linearized, cold junction compensation, |
-200...400°C | ±0.3% ~1.5°C | two-wire connection, measuring current approximately 0.8mA in pulse 50ms, |
-200...600°C | ±0.2°C (-200…100)°C range | two-wire connection, measuring current approximately 0.5mA in pulse 50ms, |
-200...600°C | ±0.2°C (-200…100)°C range | two-wire connection, measuring current approximately 0.5mA in pulse 50ms, |
0...300Ω | 0.1% FS (±0.3Ω) | measuring current approximately 0.8mA / 50ms, |
0...3000Ω | 0.1% FS (±3Ω) | measuring current approximately 0.5mA / 50ms, |
0...10000Ω | 0.1% FS (±10Ω) | measuring current approximately 0.1mA / 50ms, |
Binary inputs (for two-states signals) | input voltage for state "L" (IN-COM) < 0.8 V (Rin < 1 kOhm). | |
RS485IN | E.g. data acquisition from temperature, humidity, pressure sensors Tx41x, Hx43x. | |
MS6D monitoring system with data logger‘s description on Comet System website [EN]