Пассивный сепаратор сигналов, стандартного 0/4…20мA тока, питаемый от токовой петли.
- Устройство предназначено для преобразования сопротивления, стандартного напряжения и тока термодатчика на сигналы постоянного напряжения и тока
- Ввод гальванически изолирован от выхода и питания
- С помощью программатором PD14 можно запрограммировать тип выхода, период усреднения, настроить индивидуальную характеристику выхода и измеряемый сигнал
- Input: Pt100 (2-, 3-, 4-wire)
- Measurement range: -200...+850 °C
- Resolution: 24 bits
- Very low current consumption
- No external power supply needed
- Warranty: 3 years
- Connection: RJ-11
- Air velocity measurement range: 0...2 / 0...10 / 0...20 m/s (selectable via jumper)
- Temperature measurement range: 0...50 °C
- Output: 0...10 V / 4...20 mA
- Option: LCD screen
- Option: relay output
- Supply: 24 VDC/VAC
- Operating temperature: 0...+50°C
- Protection class: IP54
- Temperature measurement range: -30...+80 °C
- Humidity measurement range: 0...100 %
- Output: RS-485 Modbus RTU
- Calculates absolute humidity and dew-point temperature
- Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
- Operating temperature: -20...+60 °C
- Supply: 9...28 VAC/VDC
Carbon dioxide (CO2) and temperature transmitter with a display CDT2000 Duct. The device is designed for measurement of air parameters in ventilation channels.
- CO2 range 400...2000 ppm
- Temperature range 0...50 °C
Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.
- Carbon dioxide (CO2) range: 400...2000 ppm
- Humidity range: 0...100 %
- Temperature range: 0...50 °C
Temperature transducers P4141, P4121, P4151, P4131, P4161, P4171, P4191 with 4...20 mA output and Pt1000 input.
P4121 – P4171 class transducers are designed to convert RTD Pt1000 (3850ppm/°C) signal to current. These transducers have 4...20 mA output. RTD sensor Pt1000 is not included.
- Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
- Temperature input: none / Pt100 / Pt1000 / thermocouple
- Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
- Relay output: 3 units
- Communication interface: none / RS-232 / RS-485 / USB / CANopen
- Invertible analogue output (10...0 V, 20...0 mA)
- Fast and easy parameter configuration via USB
- Optional tare function (scaling to zero)
- Supply: 220 VAC / 24 VAC/DC
- Operating temperature: 0...50 °C
- Protection class: IP60 (front)
- Pressure measurement range: -250...2500 / -250...7000 Pa
- Input: 2 x 0...10 V, NTC10k, Pt1000, Ni1000, binary
- Output: Modbus RTU
- Temperature compensation in range of 0...50 °C
- Allowed overpressure: 25 kPa
- Supply: 24 VDC/VAC
- Operating temperature: -20...+50°C
- Protection class: IP54
- PID controller
- Pressure measurement range: 0...2500 Pa
- Modbus RTU communication
- Control output: 0...10 V
- External input: 0...10 V / thermistor / binary
- LCD display
- Temperature compensation
- Allowed overpressure: 25 kPa
- Supply: 24 VDC
- Operating temperature: -20...+50°C
- Protection class: IP54
Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.
Duct temperature transducer with 0...10 V output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Output temperature range is user adjustable. Calibration certificate is included.
- Temperature measurement range: -35…+80 ºC
- Humidity measurement range: 0…100 % RH
- Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
- Output: Modbus RTU
- Allowed overpressure/ bellow: ± 50 kPa
- Operating temperature: 24 VAC / 15…35 VDC
- Protection class: IP 65
- Ethernet connection
- Analog inputs: 2 (0...10 VDC)
- Digital inputs: 2
- Relay outputs: 2 (NO/NC)
- 1-Wire input (up to 8 sensors)
- Memory: 70 000 values
- Modbus TCP/IP support
- Webserver
- XML/JSON, HTTP API commands
- SNMP alarms (up to 5 recipients)
- E-mail alarms (up to 5 recipients)
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Calorimetric measuring principle
- Units freely selectable via keys at the display
- Display shows 2 values at the same time, twistable by 180 ° degree
- Integrated Modbus interface enables connection control systems, SCADA
- M-Bus (optional)
- Analog output 4...20 mA
- Pulse output (galvanic isolation)
- High measuring accuracy (ideal for leakage measurement)
- Temperature measurement range: 0...50 °C
- Humidity measurement range: 0...100 %
- Output: 2 x 0...10 V / 2...10 V / 4...20 mA
- Option: LCD display
- Option: relay output
- Option: Modbus RTU
- Supply: 24 VDC/VAC
- Operating temperature: 0...50 °C
- Protection class: IP20
- Temperature measurement range: 0...50 °C
- Humidity measurement range: 0...100 %
- Output: 2 x 0/2...5/10 VDC
- Option: LCD display
- Option: Modbus RTU
- Supply: 24 VDC/VAC
- Operating temperature: 0...50 °C
- Protection class: IP54
- Temperature measurement range:
a) Ambient model: -20...+80 °C
b) Remote model with polycarbonate probe: -20...+80 °C
c) Remote model with stainless steel probe: -40...180 °C - Relative humidity measurement range: 0...100 %
- Calculates dew point, absolute humidity, enthalpy and combination ratio
- 4-wire analog output: 0...5/10 V or 0/4...20 mA
- 2 relay outputs
- Versions with or without display
- Protection class: IP65 (ABS V0 housing)
- Ethernet connection
- Digital inputs: 2
- 1-Wire input (up to 2 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- IP watchdog function
- Webserver
- SNMP alarms
- VLAN and MAC address filtering
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- Designed for air temperature and humidity sensors / transmitters
- Transmitter entirely protected inside the shield
- Prevention of condensation by downward sensor orientation
- Advanced weather protection by maximized top cover area (Ø 250 mm)
- Passively ventilated, requires no power
- Plate system permits air flow through the sensor
- ASA plastic is resistant to mechanical damage and UV radiation. It is anti-static and very stable over time.
- Ethernet connection
- Digital inputs: 2
- 1-Wire input (up to 2 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- Webserver
- HTTP and XML API commands
- E-mail alarms, SMTP, SNMP
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
- Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
- 2000 VAC galvanic isolation
- High accuracy
- EMC compliance - CE symbol
- Mounting on DIN rail - EN-50022 complience
- Supply voltage: 10...30 VDC
- Ambient temperature: -10...+60°C
- Modbus Slave over RS-485
- Modbus RTU / Modbus ASCII protocols
- Communication parameters configurable by dip-switches
- Watch-dog alarm
- Remotely configurable
- 3-way galvanic isolation (1500 VAC)
- High accuracy
- Mounting on DIN rail - EN-50022 compliance
- Ethernet 10/100 Base-T interface
- Modbus TCP server
- Webserver for configuration of device and representation of actual input values
- Galvanic isolation on all the ways (1500 VAC)
- Remotely configured
- LED indication
- EMC compliance
- DIN rail mounting
- Flexible spears for grain temperature measurement
- Rigid construction
- Diameter: Ø8 mm
- Penetration depth: up to 12 m
- Digital temperature sensor
- Measurements are done using PC software or handheld reader GW-200
- Temperature spears and cables can be integrated into single system
- Measures ambient air temperature and humidity
- Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time
Temperature and humidity transmitter with 4-20mA output.
- Patented quality product (immersion sensor patent)
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: 0 – 10 V or 4...20 mA
- Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
- Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
- Medium: in liquid or gaseous media
- For aggressive media, stainless steel immersion sleeves must be used
- Ambient temperature: -30…+70 ºC
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-1 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
- Electrical connection:
- A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
- 2-wire, 3-wire, a contact terminal
- Measuring range: -40…180 °C (depends on probe)
- Operating temperature (case with transmitter): -40…80 °C
- The sensor TJ-4 is selected according to the individual order
- Mounting box:
- Material: Polystyrene
- Dimensions: 64,4x 88,4x 42,2mm
- Protection class: IP65
- The design could be changed according the requirements and drawings of the customer
- Operates as a temperature switch (thermostat), transducer, data logger
- Accumulated temperature data is read using a mobile phone with NFC interface
- Parametrization via NFC interface
- Display and electrical connection are independently rotatable 335°/343°
- Temperature measurement range: -50...+150 °C
- Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
- Switch output: 2 x PNP
- Sensor: Pt1000 A
- Data logger memory: 3518 measurement points
- Measurement interval: 0,1...999,9 s
- Operating temperature: -25...+85 °C
- Supply: 15...30 VDC
- Temperature transmitter 5331A with 4...20 mA output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5333A with 4...20 mA output, designed for RTD signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334A with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334B for explosive Ex atmosphere with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
Temperature transmitter DAT1010 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm) ir voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1015 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1066 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA). With galvanic isoliation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
- Input (configurable): TC, RTD, mV, resistance and potentiometer
- Output: Modbus RTU / ASCII Slave device over RS-485
- 1500 Vac 3-ways Galvanic Isolation
- High accuracy
- Remotely configurable over RS-485
- EMC compliance (CE mark)
- Mounting in B-type head
- Easy implementation in existing PLCs and SCADA systems
- Operating temperature: -40...+85°C
- Supply voltage: 18...30 VDC
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.
Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
The sensor SVT300-V require to be used with Broadsens's wireless gateway and advanced vibration analysis software BroadVibra.
- Alarm sent out in 0,5 second when accident detected
- Acceleration range: 2g to 16g auto adjustment
- Acceleration sampling rate: Low speed & 6.4kHz sampling rate dynamic adjustment based on vibration level
- Acceleration resolution: 16 bit
- -3dB bandwidth (Hz): x,y,z axis: 0.1Hz to 3.2kHz
- Temperature measurement range: -40…+125 °C
- Wireless data transmission (BLE): 2.4GHz; up to 300 m in open space. FCC / IC approved
- Battery life: 3…4 (12-hour running machine a day); 14250 battery, 1200 mAh
- Mounting: M6 screw hole or two screw-hole case
- Working temperature: -55…+85 °C; IP68 (IP69K optional)
- Explosive atmosphere: Intrinsic safe. ATEX & IECEx: Ex ia IIC T4 Ga; Ex ia IIIC T135 Da