PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T0610, T3610, T7610. Only to be used with internal sensors.
Application:
- Storage rooms
- Greenhouses
- Telecommunication devices
- Servers
- A/C units
- Measuring range: -1…100 bar (see datasheet)
- Basic accuracy 0,5% of range
- Output: 4…20 mA
- Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
- Operating temperature: -20…+85 / 200 °C (see datasheet)
- Stainless steel housing and diaphragm material
- Protection class: IP67 / IP68
- Pressure range: from -0,9...1,5 to 4...40 bar
- Output signal: 1 Floating change-over contact (SPDT)
- Process temperature: -40...+150 °C
- Process connection: G1/4" f, G1/2" m
- Protection class: IP66
- Pressure range: from 1...10 to 60...600 bar
- Output signal: 1 Floating change-over contact (SPDT)
- Process temperature: -30...+100 °C / -15...+150 °C
- Process connection: G1/4" f, G1/2" m
- Protection class: IP66
- Pressure range: from 0...2,5 to 0...600 bar
- Output signal: 1 or 2 PNP transistors
- Process temperature: -40...+125 °C
- Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
- Protection class: IP65, IP67
- Pressure range: from 0...2,5 to 0...700 bar
- Process temperature: -40...+125 °C
- Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
- Protection class: IP65, IP67
The small sensor dimension combined with IO-Link, the pressure and temperature value of the media make the NAI 8273 the ideal choice in various applications.
- Measuring range: -0.2...0.2 to 0...700 bar
- Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN
- Accuracy at 25°C typically: ± 0.3 % FS typ., ± 0.5 % FS typ.
- Measuring principle: Thin-film-on-steel
- Media temperature –40... +125 °C
- Ambient temperature: –40...+125 °C
- Protection class: IP65, IP67
- Applications: Hydraulics, Machine tools, Process technology
- Pressure transmitter ATM (analog output)
- Pressure measurement range: from 0 to 0,1...1000 bar
- Accuracy: < ± 0,50 / 0,25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
- Process temperature: -40...150 °C
- Operating temperature: -25..85 °C
- Materials: stainless steel, titanium
- Pressure transmitter ATM.1ST/Ex (high precision, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...1000 bar
- Accuracy: ≤ ± 0.10 / 0.05 % FS
- Output: 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -40...125 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
- Pressure transmitter ATM/Ex (for explosive Ex environment)
- Various pressure measurement ranges: 0,1...1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx, EAC
- Pressure transmitter ATM/F (hygienic)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...100 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Pressure transmitter ATM/F/Ex (hygienic, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Certificates: ATEX, EAC
- Pressure range: from 0...0,1 to 0...40 bar
- Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
- Process temperature: -25...+125 °C
- Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
- Applications: Machine tools, hydraulics, water treatment
- Protection class: IP65, IP67, IP68
- Certificates Ex ATEX and IECEx
- Ex-zones 0, 1, 2 (gas), 20, 21, 22 (dust) and mining
- High reliability and safety
- Extraordinary long-term parameter stability
- Range:
- from 0...0.4 bar to 0...2000 bar
- standard 0...0.4 bar to 0...250 bar
- accuracy: ± 0.2% of range
- Process connection: G1/4"
- Output: 4...20 mA
- Process temperature: -40°C...+120°C
- Ambient temperature: -40°C...+120°C
- Supply: 10...30 VDC
- Protection class: IP65
- Casing material: stainless steel 1.4452 (AISI630)/ 1.4301 (AISI304)
- Pressure range: from 0...6 to 0...600 bar
- Output signal: 4...20 mA / 1 x PNP / 2 x PNP
- Process temperature: -40...+125 °C
- Accuracy: 0,3 %
- Dielectric strength: 710 V
- Measurement principle: thin film on steel
- Protection class: IP65, IP67
- Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
- Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
- Pressure transmitter PTM (programmable)
- Various pressure measurement ranges: 0,1...1000 bar
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Various pressure measurement ranges: 0,1...1000 bar
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, EAC
- Various pressure measurement ranges: 0,1...1000 bar
- Temperature measurement range: -25...85 °C
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 2 x 4...20 mA
- Digital output: RS-485
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Various pressure measurement ranges: 0,1...1000 bar
- Relay output: 2 units
- Output: 0...20 mA / 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Supports devices: NAT 8252, NAH 8254, NAR 8258, ECL 8439
- Fast and easy operation via Android app “Sensor Master Communicator SMC”
- Read out of sensor data
- Parametrization of switich points on NAx pressure switches
- Measuring range adjustment on submersible pressure transmitter ECL
- Reset pressure measurement instruments to factory settings
- Ambient temperature: 0...40 °C
- Supply: 5 V (USB)
- Communication: Bluetooth Low Energy
The RUVAC WH / WHU series pumps are high throughput, hermetically sealed, water-cooled roots blower pumps with high efficiency motors that provide optimum price-to-performance ratio. Both motors and oil reservoirs are water cooled thereby perfectly balancing the internal temperature management of the pumps.
RUVAC WHU pumps are equipped with a bypass line and may be operated at its maximum power from atmospheric pressure. The WHU is equipped with improved valve technology for maximum efficiency in short cycle operation. The integrated bypass line allows for the WHU pumps to be operated starting at atmospheric pressure while the unique control flap provides extreme contamination resistance.
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
- The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- With integrated K type thermocouple
- Accuracy: 1 %
- Coefficient: 0,84 ± 0,01
- Static pressure: Atmospheric
- Temperature of use: 0…1000 °C
- Measures ambient temperature, humidity, pressure
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measuring ranges: -30...+80 °C, 0...100 %RH, 600...1100 hPa
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Calibration certificate included
- Protection class: IP30
Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.
Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.
- Flow and temperature sensor for liquids in pipes
- Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
- Flow measurement range: 1...150 cm/s (water)
- Temperature measurement switching points: 15, 30, 45, 60, 75 °C
- Flow rate measurement is shown in a bar graph by five green LEDs
- Settings provided by magnetic pen
- Stainless steel case
- Supply: 12...34 VDC
- Ambient temperature: -20...+80 °C
- Protection class: IP67 / IP68
Traditional U-shaped with easily controlled zero point. For air and non-aggressive gasses.
- Range: -500...500 Pa
- Pressure range: from -0,9...1,5 to 4...40 bar
- Output signal: 1 Floating change-over contact (SPDT)
- Process temperature: -40...+150 °C
- Process connection: G1/4" f, G1/2" m, 1/4" NPT f
- Protection class: IP65
Fluid manometer for air and non-aggressive gasses – high quality pressure meter for narrow temperature ranges.
- Range: 0…10 kPa
- Temperature measurement range: -20…+60 °C
- Humidity measuring range: 0…95 % RH
- Dew point measuring range: -60…+60 °C
- CO2 measuring range: 0…5000 ppm
- Atmospheric pressure measuring range: 700…1100 hPa
- Simple sensor connection to existing WIFI network (standard: IEEE 802.11 b/g/n)
- Measured values can be sent to the internet storage COMET Cloud or COMET Database
- Communication protocols: HTTP(S), SMTP, Modbus TCP, SNMP (v1, v2c, v3), HTTP POST, HTTP GET (JSON, XML)
- Alarm signalization: e-mail, acoustic, LED, SMS - additional order
- Measuring interval: 1 s
- Sending interval to COMET Cloud: adjustable 5 min. to 12 hours
- Calibration certificate of manufacturer included
- Operating temperature: -30…+60 °C
- Supply: 5,0…5,4 VDC USB-C connector
- Protection class: IP30
Sensor SKU: 5905309601338 (IP30)
Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.
- Atmospheric pressure measurement range: 300…1100 hPa, accuracy: absolute +/- 3 hPa in temperature 0…+65°C, relative +/- 0,12 hPa in temperature 0…+65°C
- Temperature measurement range: -35…+70 °C, accuracy up to 0,4 °C in the range from -20°C to +70°C and 0,5 °C in the range -35…-20 °C
- Relative humidity measurement range: 0…99 % RH, accuracy up to 4 % in 0…80 % RH and 7 % in the range 81…99 %
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -35…+70 °C / 0…99 %
- Case IP30 protection
Sensor SKU: 5906660327660 (IP30)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.
- Atmospheric pressure measurement range: 300…1100 hPa, accuracy: absolute +/- 3 hPa in temperature 0…+65°C, relative +/- 0,12 hPa in temperature 0…+65°C
- Temperature measurement range: -15…+70 °C, accuracy: up to 0,4 °C
- Relative humidity measurement range: 0…99 % RH, accuracy 4 % in 0…90 % RH
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
- Case IP30 protection
Sensor SKU: 5906660327868 (IP30)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.
- Carbon dioxide (CO2) measurement range: 400…5000 ppm, accuracy: +/- (40 ppm + 5 % of reading)
- Atmospheric pressure measurement range: 300…1100 hPa, accuracy: absolute +/- 3 hPa in temperature 0…+65°C, relative +/- 0,12 hPa in temperature 0…+65°C
- Temperature measurement range: -15…+70 °C, accuracy: up to 0,4 °C
- Relative humidity measurement range: 0…99 % RH, accuracy 4 % in 0…80 % RH
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
- Case IP30 protection
Sensor measures carbon dioxide (CO2) concentration, temperature, and atmospheric pressure. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- CO2 measurements:
- Range: 0…9999 ppm
- Resolution: 1 ppm
- Accuracy: ± (30 ppm + 3 % of reading)
- Atmospheric pressure measurements:
- Range: 300…1100 hPa
- Resolution: 1 hPa
- Accuracy: +3 hPa / -2 hPa
- Temperature measurements:
- Range: 0…50 °C
- Resolution: 0,1 °C
- Accuracy: ± 0.3 °C
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply: 1 x AA battery
- Battery lifetime (20 °C): up to 8 years
- Operating temperature: -40…60 °C
- Protection class: IP67
Sensor SKU: 5905309601475 (IP30)
Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.
- Differential pressure measurement range: +/- 500 Pa, accuracy: up to 1 Pa
- Length of measuring tubes: 1 m (another lengths on request)
- Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh, 3xAA battery (replaceable)
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
- Possibility to integrate sensor to other third-party systems
- Operating temperature / humidity: -15…+70 °C / 0…99 %
- Case IP30 protection
Sensor SKU: 5906660327820 (IP30)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.
- Differential pressure measurement range: +/- 500 Pa, accuracy: up to 1 Pa
- Length of measuring tubes: 1 m (another lengths on request)
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Case IP30 protection
Measure the difference in air pressure between two points as needed in HVAC (air filter condition), building automation and Pharma. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.
- Pressure range: ± 500 Pa
- Resolution: 0,02 Pa
- Accuracy: ± (0.10 Pa + 3 % of reading)
- Long term drift: 0,05 Pa / year
- Response time: (99 %) <1 s
- Calibrated for Air, N2
- Gas compatibility: Air, N2, O2
- Operational range (in line-of-sight): up to 3 km
- Data transmission: 1, 2, 5, 10 min
- Data encryption
- Supply: 1 x AA battery
- Battery lifetime (20 °C): up to 10 years
- Operating temperature: -40…60 °C
- Protection class: IP65
Sensor SKU: 5905309600584 (IP67)
Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.
- Pressure measurement range: 0…7 bar (0…101 PSI), accuracy: +/- 0,25% FSO (0…20 bar on request)
- Pressure type: Gage
- Probe cable length: 1m
- Communication NB-IoT bands: default B8 and B20 (others on request)
- Measurement period: 1 minutes to 18 hours (configurable by the user)
- Measurement sending interval: 5 minutes to 7 days (configurable by the user)
- Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
- The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
- Possibility to integrate sensor to other third-party systems
- Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
- Case IP67 protection
Radon gas is tasteless, odorless, and hard to detect, posing serious health risks. It escapes from the ground into the air and can accumulate in your home. Radon is a radioactive element, and higher concentrations entering the lungs can cause cancer. Since its levels can fluctuate regular radon monitoring is vital.
- Radon measurement range: 0…4000 Bq/m3
- Temperature measurement range: 0...+50 °C
- Humidity measurement range: 0...99 %
- Pressure measurement range: 600...1100 hPa
- Operational range (in line-of-sight): up to 3 km*
- Bluetooth Low Energy connection with smartphone (Android or iOS) using Aranet Home mobile app
- Supply: 2 x AA batteries
- Battery lifetime (20 °C): up to 7 years (see datashet)
- E-Ink display for longer battery life
- Operating temperature: 0...+50 °C
- Protection class: IP20
- Temperature measurement range: 0...+50 °C
- Humidity measurement range: 0...85 %
- Pressure measurement range: 300...1100 hPa
- CO2 concentration measurement range: 0...9999 ppm
- Operational range (in line-of-sight): up to 10 m (Bluetooth Low Energy)
- Data is sent to smartphone (Android, iOS), no need for special receiver
- Data transmission: 1, 2, 5, 10 min
- Aranet4 anti-theft wall mount is available
- Data encryption
- Supply: 2 x AA batteries
- Battery lifetime (20 °C): up to 2 years
- Operating temperature: 0...+50 °C
- Protection class: IP20
- Temperature measurement range: 0...+50 °C
- Humidity measurement range: 0...85 %
- Pressure measurement range: 300...1100 hPa
- CO2 concentration measurement range: 0...9999 ppm
- Operational range (in line-of-sight): up to 3 km
- Bluetooth Low Energy operational range for direct connection with smartphone (Android or iOS): up to 10 m
- Data transmission: 1, 2, 5, 10 min
- Aranet4 anti-theft wall mount is available
- Data encryption
- Supply: 2 x AA batteries
- Battery lifetime (20 °C): up to 2 years
- Operating temperature: 0...+50 °C
- Protection class: IP20
- Pressure measurement range: 5...25000 μm
- Operating temperature: -10...+50 °C
- Overload: 610 bar
- Two valve system
- Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
- 124 refrigerant gases
- Pressure measurement range: -1...60 bar
- Pressure measurement accuracy: ± 0,5 % of full scale
- Overload: 65 bar
- Operating temperature: -20...+50 °C
- Used with wireless manifold
- 124 refrigerant gases
Differential manometer MM for air and non-aggressive gasses, designed for pressure measurement in narrow ranges.
- Range: -100…1500 Pa
- Operating temperature: -40… +60°C
- Measurement range: -40...+150 °C, -1...60 bar
- Temperature measurement accuracy: ± 1,3 °C
- Pressure measurement accuracy: ±0,5 % of full scale
- Operating temperature: -20...+50 °C
- Overload: 65 bar
- Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
- 124 refrigerant gases
- Measurement range: -40...+150 °C, -1...60 bar
- Temperature measurement accuracy: ± 1,3 °C
- Pressure measurement accuracy: ±0,5 % of full scale
- Operating temperature: -20...+50 °C
- Overload: 65 bar
- Two valve system
- Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
- 124 refrigerant gases
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: piston
- Measured pressure from -0,6...3,4 to 4...40 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: -25...+125 °C / -40...+125 °C
- Ambient temperature: -25...+125 °C / -40...+125 °C
- Protection: IP65
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: piston
- Measured pressure from 1...10 to 40...400 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: -25...+125 °C
- Ambient temperature: -25...+85 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, EN60730-1 / EN60730-2-9: Typ 2.B.H
- Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measuring principle: membrana
- Measured pressure from 1...10 to 10...100 bar
- Output signal: floating change-over contact (SPDT)
- Switching differential: not adjustable
- Media temperature: 0...+80 °C
- Ambient temperature: 0...+80 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option