This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Transmitters

Transmitters
Show:
Sort By:
  • Sensor: Pt100 (3-wire) / TC: K (with display / without display)
  • Output: HART / sensor output
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Various connection options
  • Supply: 12...40 VDC (HART), CR2032 (for screen)
  • Protection class: IP65
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitters with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…80 °C
  • Operating temperature: -40…80 °C
  • The sensor can be distanced, meaning the TJ-O can be equipped with the following external temperature sensors: TJ-1, TJ-2, TJ-4, TJ-S
  • Sensor tube:
    • Material: Stainless steel AISI304 (1.4301)
    • Diameter: Ø6 mm
    • Length: 25 mm
  • Mounting box:
    • Material: Polystyrene
    • Dimentions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-1 is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-4 is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-S is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Operates as a temperature switch (thermostat), transducer, data logger
  • Accumulated temperature data is read using a mobile phone with NFC interface
  • Parametrization via NFC interface
  • Display and electrical connection are independently rotatable 335°/343°
  • Temperature measurement range: -50...+150 °C
  • Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
  • Switch output: 2 x PNP
  • Sensor: Pt1000 A
  • Data logger memory: 3518 measurement points
  • Measurement interval: 0,1...999,9 s
  • Operating temperature: -25...+85 °C
  • Supply: 15...30 VDC
  • Temperature transducer TJ-DIN AV, designed to convert temperature measurement signal into 4...20 mA, 0...10 V
  • Mounted on 35 mm DIN rail
  • Temperature transmitter 5331A with 4...20 mA output, designed for TC, RTD, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5333A with 4...20 mA output, designed for RTD signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5334A with 4...20 mA output, designed for TC, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5334B for explosive Ex atmosphere with 4...20 mA output, designed for TC, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
  • To be mounted into B-type electric head
  • Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
  • To be mounted into B-type electric head

Temperature transmitter DAT1010 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm) ir voltage (mV) signal conversion to analog (4...20 mA).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1015 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N)  and voltage (mV) signal conversion to analog (4...20 mA).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1066 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N)  and voltage (mV) signal conversion to analog (4...20 mA). With galvanic isoliation (1500 VAC).

The transmitter is mounted into a B-type head. Programming can be done in our company.

Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).

The transmitter is mounted into a B-type head. Programming can be done in our company.

  • Input (configurable): TC, RTD, mV, resistance and potentiometer
  • Output: Modbus RTU / ASCII Slave device over RS-485
  • 1500 Vac 3-ways Galvanic Isolation
  • High accuracy
  • Remotely configurable over RS-485
  • EMC compliance (CE mark)
  • Mounting in B-type head
  • Easy implementation in existing PLCs and SCADA systems
  • Operating temperature: -40...+85°C
  • Supply voltage: 18...30 VDC
  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.

Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.

  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.

Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.

  • Flow and temperature sensor for liquids in pipes
  • Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
  • Flow measurement range: 1...150 cm/s (water)
  • Temperature measurement switching points: 15, 30, 45, 60, 75 °C
  • Flow rate measurement is shown in a bar graph by five green LEDs
  • Settings provided by magnetic pen
  • Stainless steel case
  • Supply: 12...34 VDC
  • Ambient temperature: -20...+80 °C
  • Protection class: IP67 / IP68
  • Designed to measure the thickness of non-magnetic layers
  • Can be used for construction, ships, tanks, piping, boilers, vehicles protective layer quality control
  • High accuracy in wide temperature (with compensation) range using the same probe
  • Fit for work outside
  • Certificate of calibration included
  • Wood moisture transmitter KP (0...20 mA), made by Tanel (Poland)
  • Output signal 0...20 mA which corresponds to range 0...60 %; practically used range is 8...60 %
  • Transducer for AC current and voltage into DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Transducer for DC current and voltage into other DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • Solves grounding problem in meshed signal networks
  • User selectable type and range of input
  • Transducer for DC current and voltage into other DC signal (2 outputs)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
  • This enables to increase device number in the system and extend its range
  • Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
  • Input is isolated from input and supply
  • Has fixed inputs and outputs – non-programmable
  • In PD24 converter are used 2 interfaces (USB, RS232) - galvanically isolated
  • USB interface (type A) – destined for the device communication with the computer
  • RS-232 interface - destined for the communication with devices from the object side
  • PD24 is programmer of LUMEL products to configure settings using eCon software
  • Compliance with the standard USB 1.1 and USB 2.0
  • Data transmission rate up to 115.2 kbps
  • Support virtual serial port (COM)
  • Device supplied from USB port and from the RS-232 (TTL) side
  • Set includes 1,5 m data transmission cable with RJ12 plugs to configure LUMEL products
  • External dimension: 62 x 25 x 20 mm
  • In PD20 converter are used 2 interfaces (USB, RS485) - galvanically isolated
  • USB interface (type A) – destined for the device communication with the computer
  • RS-485 interface - destined for the communication with devices from the object side
  • Compliance with the standard USB 1.1 and USB 2.0
  • Data transmission rate up to 115.2 kbps
  • Support virtual serial port (COM)
  • Bi-directional data transmission (half duplex)
  • Device supplied from USB port
  • External dimension: 76 x 25 x 20mm
  • Converter does not interfere into the structure of data transmission and is compatible with many industrial communication protocols
  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm LEL
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Remote probe option
  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 relays with switch-over contacts
  • Default alarm set-points 10 % / 25 % LEL
  • Visual and acoustic alarms
  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL (0...1 % vol) toluene
  • Resolution 3 ppm toluene
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Acoustic alarm
  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm toluene
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • For toluene, xylene, ethanol and 2-propanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range: 0...100 % LEL or 0…500 ppm
  • Resolution 0,1 % LEL or 1 ppm
  • Outputs: 2 relays with switch-over contacts
  • Acoustic and visual alarms
  • Photo ionization detector
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: isobutylene
  • Range: 0...40 / 0...200 ppm (isobutylene)
  • Resolution: 1 / 1 ppb
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+65 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: toluene
  • Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
  • Resolution: 0,1 % LEL / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

The TSF400-0 is a compact water-leak detector designed for early detection of water presence on floors, trays, or inside equipment enclosures. It operates from a wide 4.5–26 VDC supply and provides an N-channel open-drain output for direct connection to PLCs, controllers, alarm modules, or building-automation systems.

Applications:

Leak detection in server rooms, UPS rooms and telecom shelters
HVAC drip trays, cooling/condensation lines
Under-floor and raised-floor monitoring
Domestic and commercial flood-alert systems

Specifications:

Operating temperature range: 0...50 °C
Ingress protection: IP65
Cable length: 3 m

  • MA series converters reads Wired M-Bus meters and transmit the data wirelessly using the Wireless M-Bus protocol
  • Reads data from up to 500 devices
  • Communication: wM-BUS EN 13757-3/4:2013, complies OMS 4.0.2
    • Modes: T1
  • AES-128 encryption mode 5, profile A
  • Automatically search wired meters and sends data
  • Two internal antennas or one external antenna
  • Power supply: 100…240 VAC
  • Protection class: IP67

Sensor SKU: 5905309601192 (IP30)

Sensor SKU: 5905309601482 (IP67)

Wireless 4…20 mA / 0…10 V analog signal data logger, sensor interface, BLE allows users to connect analog sensors to the cloud**. Device can be equipped with up to four analog interfaces / transducers (2 x 4…20 mA and 2 x 0…10 V). Transducer can be powered* either from the device’s battery or by an external power source.

You can use a free mobile application to configure the device and read the data from its memory. If you add Efento Gateway, you can build a remote monitoring system.

  • Communication: BLE (Bluetooth Low Energy)
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery (on request 1000 mAh rechargeable battery (USB 5V))
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • External transducers can be powered by the device's battery (max. 16V, 30 mA)
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -15…+70 °C / 0…99 %
  • Case IP30 protection (IP 67 on request)

Sensor SKU: 5905309600072 (IP30)

Sensor SKU: 5905309600607 (IP67)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.

  • Wireless 4…20 mA / 0…10 V analog signal sensor interface, data logger, NB-IoT measures analog readings and can send data over NB-IoT
  • Device can be equipped with up to four analog interfaces / transducers (2 x 4…20 mA and 2 x 0…10 V)
  • Transducer can be powered* either from the device’s battery or by an external power source
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -35…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection (IP67 on request)

Sensor SKU: 5905309601338 (IP30)

Efento BLE sensors transmit the data over BLE (Bluetooth Low Energy) and send data to the Efento cloud** through Efento gateway or to other third-party integration. Free mobile application let to configure the device and read the data from its memory.

  • Atmospheric pressure measurement range: 300…1100 hPa, accuracy: absolute +/- 3 hPa in temperature 0…+65°C, relative +/- 0,12 hPa in temperature 0…+65°C
  • Temperature measurement range: -35…+70 °C, accuracy up to 0,4 °C in the range from -20°C to +70°C and 0,5 °C in the range -35…-20 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy up to 4 % in 0…80 % RH and 7 % in the range 81…99 %
  • Measurement and transmission period: 5 seconds to 30 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation (15 min. measurement interval), 2700 mAh, 3,6 V, AA battery (replaceable)
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • The device can be used as a stand-alone data logger or connected to the Efento gateway to view and store data in the Efento cloud
  • Possibility to integrate sensor to other third-party systems
  • Operating temperature / humidity: -35…+70 °C / 0…99 %
  • Case IP30 protection

Sensor SKU: 5906660327660 (IP30)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud platform or any other third party systems.

  • Atmospheric pressure measurement range: 300…1100 hPa, accuracy: absolute +/- 3 hPa in temperature 0…+65°C, relative +/- 0,12 hPa in temperature 0…+65°C
  • Temperature measurement range: -15…+70 °C, accuracy: up to 0,4 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy 4 % in 0…90 % RH
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection

Sensor SKU: 5906660327868 (IP30)

Efento NB-IoT sensors transmit the data over cellular network (Narrowband IoT) and do not require any additional devices (router, gateway, etc.). Sensors are also equipped with Bluetooth Low Energy interface, which allows quick and easy configuration with a smartphone. Efento NB-IoT sensors can be integrated with Efento Cloud** platform or any other third party systems.

  • Carbon dioxide (CO2) measurement range: 400…5000 ppm, accuracy: +/- (40 ppm + 5 % of reading)
  • Atmospheric pressure measurement range: 300…1100 hPa, accuracy: absolute +/- 3 hPa in temperature 0…+65°C, relative +/- 0,12 hPa in temperature 0…+65°C
  • Temperature measurement range: -15…+70 °C, accuracy: up to 0,4 °C
  • Relative humidity measurement range: 0…99 % RH, accuracy 4 % in 0…80 % RH
  • Communication NB-IoT bands: default B8 and B20 (others on request)
  • Measurement period: 1 minutes to 18 hours (configurable by the user)
  • Measurement sending interval: 5 minutes to 7 days (configurable by the user)
  • Battery ensures up to 5 years of maintenance-free operation, 6300 mAh battery
  • The device stores 40,000 measurements in its memory, when the memory is full, the oldest measurements are overwritten
  • Possibility to integrate sensor to other third-party systems
  • Operating environmental: -15…+70 °C / 0…99 % RH non-condensing
  • Case IP30 protection

Sensor measures carbon dioxide (CO2) concentration, temperature, and atmospheric pressure. This device, belonging to the PRO sensor series, includes Aranet Sub-GHz ISM band radio which wirelessly transmits sensor measurements to the Aranet PRO base station.

  • CO2 measurements:
    • Range: 0…9999 ppm
    • Resolution: 1 ppm
    • Accuracy: ± (30 ppm + 3 % of reading)
  • Atmospheric pressure measurements:
    • Range: 300…1100 hPa
    • Resolution: 1 hPa
    • Accuracy: +3 hPa / -2 hPa
  • Temperature measurements:
    • Range: 0…50 °C
    • Resolution: 0,1 °C
    • Accuracy: ± 0.3 °C
  • Operational range (in line-of-sight): up to 3 km
  • Data transmission: 1, 2, 5, 10 min
  • Data encryption
  • Supply: 1 x AA battery
  • Battery lifetime (20 °C): up to 8 years
  • Operating temperature: -40…60 °C
  • Protection class: IP67
Loading...