  • Temperature measurement range: -30...+80 °C
  • Humidity measurement range: 0...100 %
  • Output: RS-485 Modbus RTU
  • Calculates absolute humidity and dew-point temperature
  • Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
  • Operating temperature: -20...+60 °C
  • Supply: 9...28 VAC/VDC
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Stem length 700 mm
  • Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
  • Display with two periodically changed shown values (can be switched off)
  • Integrated sensors
  • Calibration certificate is included
  • Programmable output
  • Low temperature inertia
  • For use in non-aggressive environment
  • 3 year warranty

Moisture measuring of sand, minerals, clay, grain, foodstuffs, sawdust, ores, sewage sludge. During operation, the sensor requires nothing but a power supply and a display or a controller that can receive the measurement signal. The BMMS sensor is designed for applications in which no multi-part systems are to be used but still the highest precision is required. Due to the in-process calibration, all potential interference from the sensor installation is directly compensated for.

  • Capacitive moisture measurement
  • Temperature range of measuring material: 4...50 °C
  • Direct measured values transfer from the sensor
  • Calibration is made directly at sensor, beyond the process
  • Capacitive moisture measurement
  • Up to 16 sensors per signal processing unit
  • Temperature range of measuring material: 4...80 °C
  • Measured value transfer: Profibus DP or analogue standard signal (e.g. 4...20 mA) optional
  • Continuous measurement or batch operation

Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.

  • Carbon dioxide (CO2) range: 400...2000 ppm
  • Humidity range: 0...100 % 
  • Temperature range: 0...50 °C
  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65

At extra cost: 2 analog outputs (0...10V, 4...20mA), membranous filter, teflon filter, bronze filter.

The sensor changes measured parameters to an analog or a digital signal.

  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0...10 V / 2...10 V / 4...20 mA
  • Option: LCD display
  • Option: relay output
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP20
  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0/2...5/10 VDC
  • Option: LCD display
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP54
  • Temperature measurement range:
    a) Ambient model: -20...+80 °C
    b) Remote model with polycarbonate probe: -20...+80 °C
    c) Remote model with stainless steel probe: -40...180 °C
  • Relative humidity measurement range: 0...100 %
  • Calculates dew point, absolute humidity, enthalpy and combination ratio
  • 4-wire analog output: 0...5/10 V or 0/4...20 mA
  • 2 relay outputs
  • Versions with or without display
  • Protection class: IP65 (ABS V0 housing)

The P18L transducer is a device destined for the continuous measurement and conversion of relative humidity and ambient temperature into a standard analog signal 4...20mA.

 

  • P18L transducer is supplied from a current loop.
  • Applied sensor shields enable the application of the P18L transducer to operate in various ambient conditions.
  • Long-lasting stainless steel screw electrodes
  • Measurement range: 7...20 % (-40...+125 °C)
  • Resolution: 0,1 %
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Electrode cable: FEP, -50...+200 °C, 5/10/15 m
  • Timber temperature compensation
  • Electrode length: 15 / 25 mm
  • Supply: 11...30 VDC
  • Protection class: IP68
  • Designed for air temperature and humidity sensors / transmitters
  • Transmitter entirely protected inside the shield
  • Prevention of condensation by downward sensor orientation
  • Advanced weather protection by maximized top cover area (Ø 250 mm)
  • Passively ventilated, requires no power
  • Plate system permits air flow through the sensor
  • ASA plastic is resistant to mechanical damage and UV radiation. It is anti-static and very stable over time.

Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.

  • Measures ambient air temperature and humidity
  • Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time

Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.

 

  • Integrated temperature and humidity sensor
  • Calculated values – dew point temperature, absolute humidity
  • Minimal and maximal value memory
  • Isolated RS-485 port
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included

Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.

Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.

  • Wood moisture transmitter KP (0...20 mA), made by Tanel (Poland)
  • Output signal 0...20 mA which corresponds to range 0...60 %; practically used range is 8...60 %