- Temperature measurement range: -30...+80 °C
- Humidity measurement range: 0...100 %
- Output: RS-485 Modbus RTU
- Calculates absolute humidity and dew-point temperature
- Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
- Operating temperature: -20...+60 °C
- Supply: 9...28 VAC/VDC
- Ambient temperature and humidity transducer with 4...20 mA output
- Stem length 700 mm
- Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
- Display with two periodically changed shown values (can be switched off)
- Integrated sensors
- Calibration certificate is included
- Programmable output
- Low temperature inertia
- For use in non-aggressive environment
- 3 year warranty
Moisture measuring of sand, minerals, clay, grain, foodstuffs, sawdust, ores, sewage sludge. During operation, the sensor requires nothing but a power supply and a display or a controller that can receive the measurement signal. The BMMS sensor is designed for applications in which no multi-part systems are to be used but still the highest precision is required. Due to the in-process calibration, all potential interference from the sensor installation is directly compensated for.
- Capacitive moisture measurement
- Temperature range of measuring material: 4...50 °C
- Direct measured values transfer from the sensor
- Calibration is made directly at sensor, beyond the process
- Capacitive moisture measurement
- Up to 16 sensors per signal processing unit
- Temperature range of measuring material: 4...80 °C
- Measured value transfer: Profibus DP or analogue standard signal (e.g. 4...20 mA) optional
- Continuous measurement or batch operation
Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.
- Carbon dioxide (CO2) range: 400...2000 ppm
- Humidity range: 0...100 %
- Temperature range: 0...50 °C
- Temperature measurement range: -35…+80 ºC
- Humidity measurement range: 0…100 % RH
- Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
- Output: Modbus RTU
- Allowed overpressure/ bellow: ± 50 kPa
- Operating temperature: 24 VAC / 15…35 VDC
- Protection class: IP 65
At extra cost: 2 analog outputs (0...10V, 4...20mA), membranous filter, teflon filter, bronze filter.
The sensor changes measured parameters to an analog or a digital signal.
- Temperature measurement range: 0...50 °C
- Humidity measurement range: 0...100 %
- Output: 2 x 0...10 V / 2...10 V / 4...20 mA
- Option: LCD display
- Option: relay output
- Option: Modbus RTU
- Supply: 24 VDC/VAC
- Operating temperature: 0...50 °C
- Protection class: IP20
- Temperature measurement range: 0...50 °C
- Humidity measurement range: 0...100 %
- Output: 2 x 0/2...5/10 VDC
- Option: LCD display
- Option: Modbus RTU
- Supply: 24 VDC/VAC
- Operating temperature: 0...50 °C
- Protection class: IP54
- Temperature measurement range:
a) Ambient model: -20...+80 °C
b) Remote model with polycarbonate probe: -20...+80 °C
c) Remote model with stainless steel probe: -40...180 °C - Relative humidity measurement range: 0...100 %
- Calculates dew point, absolute humidity, enthalpy and combination ratio
- 4-wire analog output: 0...5/10 V or 0/4...20 mA
- 2 relay outputs
- Versions with or without display
- Protection class: IP65 (ABS V0 housing)
The P18L transducer is a device destined for the continuous measurement and conversion of relative humidity and ambient temperature into a standard analog signal 4...20mA.
- P18L transducer is supplied from a current loop.
- Applied sensor shields enable the application of the P18L transducer to operate in various ambient conditions.
- Long-lasting stainless steel screw electrodes
- Measurement range: 7...20 % (-40...+125 °C)
- Resolution: 0,1 %
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Electrode cable: FEP, -50...+200 °C, 5/10/15 m
- Timber temperature compensation
- Electrode length: 15 / 25 mm
- Supply: 11...30 VDC
- Protection class: IP68
- Designed for air temperature and humidity sensors / transmitters
- Transmitter entirely protected inside the shield
- Prevention of condensation by downward sensor orientation
- Advanced weather protection by maximized top cover area (Ø 250 mm)
- Passively ventilated, requires no power
- Plate system permits air flow through the sensor
- ASA plastic is resistant to mechanical damage and UV radiation. It is anti-static and very stable over time.
Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.
- Measures ambient air temperature and humidity
- Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time
Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.
- Integrated temperature and humidity sensor
- Calculated values – dew point temperature, absolute humidity
- Minimal and maximal value memory
- Isolated RS-485 port
- Measures air temperature, humidity
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...+80 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...105 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- External sensor cable length: 1 / 2 / 4 m
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
Temperature and humidity transmitter with 4-20mA output.
- Measures air temperature, humidity in ducts
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measurement ranges: -30...125 °C / 0...100 %RH
- Operating temperature: -30...+60 °C
- Ex marking: EX II 3G Ex ic IIC T6 Gc
- Output: 4...20 mA, galvanically isolated
- Adjustable by PC
- Supply: 9...30 VDC
- Calibration certificate included
Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.
Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.
- Wood moisture transmitter KP (0...20 mA), made by Tanel (Poland)
- Output signal 0...20 mA which corresponds to range 0...60 %; practically used range is 8...60 %