  • Operating on the Pitot tube principle
  • Insensitive to airflow direction
  • Accuracy: 2 %
  • Pairs well with HK Instruments DPT-FLOW transducers
  • Connection: 1/4” OD tubing
  • Operating temperature: 5...95 °C
  • Round or rectangular duct
  • Various duct size options (up to 1200 mm)
  • Air velocity measurement range: 0...2 / 0...10 / 0...20 m/s (selectable via jumper)
  • Temperature measurement range: 0...50 °C
  • Output: 0...10 V / 4...20 mA
  • Option: LCD screen
  • Option: relay output
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...7000 Pa
  • Air flow and velocity measurement
  • LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 9 V battery
  • Operating temperature: 10...+50°C
  • Protection class: IP54
  • Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
  • Air flow and velocity measurement
  • Output: 0...10 V / 2...10 V or 4...20 mA
  • Option: autozero function and LCD screen
  • Allowed overpressure: 25 kPa
  • Supply: 10...35 VDC
  • Operating temperature: -40...+50°C (see datasheet)
  • Protection class: IP54
  • Universal airflow monitor with Safety Integrity Level 1 (SIL1) according to IEC 61508/IEC61511 (alternatively device with SIL2 certification available)
  • With switching output suitable for control cabinet installation
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Large measuring range from 0.1 ... 30 m/s, quick and easy commissioning
  • Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC
  • Compact air flow meter with switching output (1 NO)
  • Robust sensor design, protection class IP67 and compact dimensions
  • Switching point continuously adjustable between 0.1...15 m/s (extended measuring range available with RLSW5)
  • Exemplary areas of application: monitoring of fans, heating registers, extraction, soldering and air curtain systems
  • Compact air flow meter with analogue output (0…10 V & 4…20 mA)
  • Robust sensor design, protection class IP67 and compact dimensions
  • Media temperature up to 70 °C
  • Switching point continuously adjustable between 0.1...30 m/s
  • Exemplary areas of application: Visualization and control of air flows in building automation, filter and fan monitoring as well as in industrial applications such as catalytic converters
  • Flow monitors for water and air flows
  • Robust stainless steel sensor housing for industrial environments
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Switching point sensitive and continuously adjustable both for liquids (0.03 ... 3 m/s) and for gases (0.5 ... 20 m/s)
  • With switching output (1 NO/ 1 NC)
  • Exemplary areas of application: Monitoring of air and water flows, cooling circuits up to 30% glycol content, pump monitoring

Compact sensor VA 525 for measuring compressed air or nitrogen inline.

  • 4...20 mA and pulse or a Modbus RTU (RS 485) interface as standard
  • Optional interfaces such as Modbus TCP (Ethernet), PoE, M-Bus available
  • Pressure range up to 16 bar
  • Temperature range up to 60°C
  • For speeds up to 224 Nm/s
  • Integrated display to show the measured values
  • Available from 1/4" to 2''
  • Settings adjustable via the keys of the display
  • Main counter can be reset via the display
  • Air flow monitor with switching output for control cabinet installation
  • Safely and reliably monitor hot air flows up to 400°C
  • Sensitive response behaviour
  • Large measuring range (0.1...30 m/s), simple and fast commissioning
  • Areas of application: Monitoring of heating coils, drying plants, industrial ovens, granulate dryers, surface technology plants, thermoprocess technology
  • Flow monitoring with SIL1 certification according to IEC 62061 (corresponds to Performance Level c according to EN ISO 13849-1)
  • Can be used in ATEX zones 1 and 2 in conjunction with 2 Zener barriers supplied
  • Large measuring range from 0.1 to 30 m/s with media temperatures from 0°C to 60°C
  • With switching output suitable for control cabinet installation
  • Developed for demanding industrial applications, IP40
  • Example areas of application: Flow monitoring in paint shops, paper factories and research facilities
  • Air flow monitor for monitoring air flow in ATEX zones 1 and 2 (optionally additionally with SIL1 or SIL2 certification)
  • With switching output (1 NO/ 1 NC) for control cabinet installation
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Large measuring range (0.1...30 m / s), simple and fast commissioning
  • Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC, industrial furnaces, granulate dryers

Thermal mass flow sensor for compressed air and gases VA 500

  • 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
  • Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
  • Optional: Bi-directional measurement
  • Pressure tight up to 50 bar
  • Temperature range up to 110 °C
  • Protection class IP65
  • Suitable for gas velocities up to 224 Nm/s
  • Integrated display for showing the measured values
  • Can be used from 1/2" up to 40", larger diameters on request
  • Easy installation under pressure
  • Settings can be changed via the display
  • Main counter reading can be reset via the display
  • Calorimetric measuring principle
  • Units freely selectable via keys at the display
  • Display shows 2 values at the same time, twistable by 180 ° degree
  • Integrated Modbus interface enables connection control systems, SCADA
  • M-Bus (optional)
  • Analog output 4...20 mA
  • Pulse output (galvanic isolation)
  • High measuring accuracy (ideal for leakage measurement)

♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option

  • Range: -250...2550 Pa
  • Maximal overpressure: 30 kPa
  • Accuracy: ±1,4 %
  • Pressure and air flow measurements from air diffusers and valves
  • Data can be uploaded on your computer for visualization and further analysis
  • Over 700 programmed valve types
  • Mediums: air and non-aggressive gases
  • Operating temperature: -10... +50 °C
  • Connection: ø 5 mm pressure hoses
  • Can be used with Pitot tube
  • 5 year warranty
  • Included: calibration certificate, 2 x 2 m PVC hoses
  • Measured parameters (with respective sensors):
    a) Temperature (Pt100 or thermocouple)
    b) Humidity
    c) Air quality
    d) Air velocity
    e) Airflow
    f) Tachometry
  • Two inputs for Pt100 temperature sensors (range -200...600 °C)
  • Up to 6 measurements simultaneously
  • Power supply: Lithium-Ion battery (up to 57 hours)
  • Calibration certificate, additional battery, transport case included
  • Operating temperature: 0...50 °C
  • Protection class: IP54
  • Air velocity, airflow and temperature measurement
  • Air flow measurement with a cone
  • Automatic average
  • Display of minimum and maximum values, hold function
  • Adjustable auto shut-off
  • Detection of flow direction
  • Selection of units
  • Supplied with calibration certificate
  • Display of minimum and maximum values, hold function
  • Adjustable auto shut-off
  • Automatic average
  • Selection of units
  • Detection of flow direction (LV 110/LV 117)
  • Supplied with calibration certificate
  • Air flow measurement with a cone (LV 110/LV 117)
  • Volumetric flow and air velocity meter with linear analogue output in control quality (0...10 V & 4...20 mA) and switch
  • Suitable for media temperatures up to 350°C
  • Measured value display by means of LCD and LED
  • Freely scalable measuring range m/s, m³/h, l/min
  • Sensitive and fast airflow detection up to 30 m/s
  • Exemplary areas of application: Measurement and control of air flows, building services, PLC, filter monitoring, extraction and extrusion systems, exhaust gases and test benches

Mechanical air flow (wind) indication relay JSL-1E.