  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached.
  • Weight: 163 g; Buoy volume: 280 cm3: Maximum pressure:< 1 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
  • Double water- and air-resistant sealant increases protection against infiltration even more
  • Weight: 250 g; Buoy volume: 430 cm3; Maximum pressure: < 1 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
  • Double water- and air-resistant sealant increases protection against infiltration even more
  • Weight: 1050 g; Buoy volume: 990 cm3; Maximum pressure: < 2 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Boasts for great reliability and small size
  • Weight: 111 g; Buoy volume: 225 cm3; Maximum pressure: < 2 bar / < 5 bar

Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.

  • Material of float: stainless steel AISI 316 SS
  • Max. temperature: -30...+105 °C
  • Switch rating: 50 VA
  • Switching voltage: 230 AC / DC
  • Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC 
  • Float level switches AUREGIS LJ-V with an extension for level control
  • Operating temperature: -30...+130°C
  • Protection class: IP65 
Horizontal float level sensor LH, designed for fluid tank monitoring, usage in automation, testing, measuring and control devices.  Switching power ≤ 10 W Switching voltage ≤ 200 V AC/DC Switching current ≤ 0,5 A AC/DC Ambient temperature -20...90 ºC  Casing material PP (polypropylene) for water and weak acid devices More information PDF [LT] ..
Horizontal stainless steel float level sensor LB-1. Technical specificationsHousing: side;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..
Horizontal stainless steel float level sensor LB-2. Technical specificationsHousing: side;Material of float: stainless steel AISI 316 SS;Process connection:  1/2 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..

The AUREGIS LJ-VD4M12 multi-zone floating, stainless steel level relay with standard M12 connector is designed for liquid level measurement and regulation.

  • Connection connector: M12 (4 / 8 pins)
  • Floats and float holders are customizable (on request)
  • Connection thread: G3/4" or larger (on request)
  • Switching power: 25 VA
  • Switching voltage: 24 V AC/DC
  • Process part operating temperature: -30...+105 °C
  • Process part: Stainless steel AISI316L
  • Protection class: IP65
  • Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
  • Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Multipoint float level switches LJ-VDT for fluid level measurement and control
  • Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
Vertical float level sensor LV for fluid tank monitoring, automation, testing, measuring and control devices. Technical specifications Switching power ≤ 10 W Switching voltage ≤ 200 V Switching current ≤ 0,5 A Ambient temperature -20...90 ºC Casing material PP (polypropylene) for water and weak acid devices  LV datasheet [LT] ..
Vertical stainless steel float level sensor LB-3. Technical specificationsHousing: top;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..
Vertical stainless steel float level sensor LB-4. Technical specificationsHousing: side, 90° angle;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..