This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Transmitters

Transmitters
Show:
Sort By:

Pressure transmitter CMP 8270 with CANopen output is designed for pressure measurement from 0...1 bar to 0...600 bar. Medium accuracy, small size, high temperature- and strong vibration-resistant.

  • Output: CANopen, protocol DS301 / DS404 
  • Range: from 0...1 bar to 0...600 bar 
  • Accuracy: ±0,2%
  • Process connection: G¼ 
  • Supply: 8...32 VDC
  • Temperature: -50...135ºC
  • Ambient temperature: -40...125ºC
  • Sensor material: stainless steel (1.4542)
  • Protection class: IP67
  • Pressure range: from 0...0,1 to 0...40 bar
  • Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
  • Process temperature: -25...+125 °C
  • Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
  • Applications: Machine tools, hydraulics, water treatment
  • Protection class: IP65, IP67, IP68
  • Pressure transmitter for shipbuilding, engine manufacturing
  • Measured pressure from 0...1 bar to 0...250 bar
  • Technology: thick film on ceramic
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %
  • Operating temperature: -25...+125 °C
  • Ambient temperature: -25...+125 °C
  • Conformity: DNV, GL, KRS, RINA
  • Protection class: min. IP68

Pressure transmitter EPN/EPNCR 8298 is suited for ship industry (up to 2500 bar). Totally enclosed, stainless steel sensor system. Long-term reliability and stability, resistance to mechanical factors.

  • Range: nuo 0...2,5 iki 0...2500 bar
  • Accuracy: ± 0,3%
  • Output: 4...20mA / 0.5...4.5V DC
  • Process connection: G1/4“, R1/4“, G1/2“, M14x1.5, M18x1.5
  • Process temperature: -40°C...+125°C
  • Supply: 9...32 VDC / 5 VDC ±0.25 VDC
  • Protection class: IP67
  • Sensor material: nerūdijantis plienas 1.4548 (AISI630)     
  • Certification: GL, ABS, BV, DNV, RINA, LRS, KRS, NKK, RMRS
  • Certificates Ex ATEX and IECEx
    • Ex-zones 0, 1, 2 (gas), 20, 21, 22 (dust) and mining
  • High reliability and safety
  • Extraordinary long-term parameter stability
  • Range:
    • from 0...0.4 bar to 0...2000 bar
    • standard 0...0.4 bar to 0...250 bar
    • accuracy: ± 0.2% of range
  • Process connection: G1/4"
  • Output: 4...20 mA
  • Process temperature: -40°C...+120°C
  • Ambient temperature: -40°C...+120°C 
  • Supply: 10...30 VDC
  • Protection class: IP65
  • Casing material: stainless steel 1.4452 (AISI630)/ 1.4301 (AISI304)
  • Pressure transmitter is suited for ship industry, has extended temperature range and increased accuracy, M12 connection and IP67 protection class
  • Small size
  • Totally enclosed, stainless steel sensor system
  • Long-term reliability and stability, resistance to mechanical factors
  • Range: from 0...2,5 to 0...700 bar
  • Accuracy: ± 0,2%
  • Output: 4...20 mA
  • Process connection: G1/4" m; G1/4" m (Manometer EN 837); G1/8" a, DIN3852-E; 1/4"NPT m; M10x1 m
  • Process temperature: -25°C...+125°C
  • Ambient temperature: -40°C...+125°C
  • Supply: 9...32 VDC
  • Protection class: IP67
  • Sensor material: Stainless steel (1.4542)
  • Certification: ABS, BV, DNV, GL, KRS, LRS, RINA, for shipbuilding
  • Pressure range: from 0...6 to 0...600 bar
  • Output signal: 4...20 mA / 1 x PNP / 2 x PNP
  • Process temperature: -40...+125 °C
  • Accuracy: 0,3 %
  • Dielectric strength: 710 V
  • Measurement principle: thin film on steel
  • Protection class: IP65, IP67
  • Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
  • Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
  • Pressure transmitter for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measured pressure from 0...2,5 bar to 0...250 bar
  • Technology: thick film on steel
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %, 0,3 %
  • Operating temperature: -40...+100 °C
  • Ambient temperature: -40...+100 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS
  • Increased vibration resistance
  • Totally enclosed, stainless steel sensor system
  • Long-term reliability and stability, resistance to mechanical factors
  • Measurement range: from 0…2 to 0…2.5 bar
  • Accuracy: 0,15...0,8 % (at 25 °C
  • Output: 4...20 mA, 0...5 V, 0...10 V
  • Process connection: G1/4 (optional G1/2 with additional adapter), 1/4” NPT
  • Process temperature: -40°C...+125 °C
  • Ambient temperature: -40°C...+125 °C
  • Supply: 9/15...32 VDC
  • Protection class: IP65 / IP67
  • Sensor material: stainless steel (1.4542)
  • Pressure transmitter PTM (programmable)
  • Various pressure measurement ranges: 0,1...1000 bar
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Various pressure measurement ranges: 0,1...1000 bar
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 4...20 mA
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Certificates: ATEX, EAC
  • Various pressure measurement ranges: 0,1...1000 bar
  • Temperature measurement range: -25...85 °C
  • Adjustable 1:4 of the nominal range within -5 % to +105 %
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Output: 2 x 4...20 mA
  • Digital output: RS-485
  • Process temperature: -40... 150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Various pressure measurement ranges: 0,1...1000 bar
  • Relay output: 2 units
  • Output: 0...20 mA / 4...20 mA
  • Process temperature: -40...150 °C
  • Operating temperature: -25...85 °C
  • Materials: stainless steel, titanium
  • Measuring function: differential pressure, volume flow
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
  • Allowed overpressure: 50 kPA
  • Supply: 24 VAC
  • Medium: clear air, non-aggressive, non-combustible gases
  • Protection class: IP 54
  • Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
  • Webserver
  • Functional Block programming software
  • LED signaling for Link/Act Ethernet, serial RX-TX, power supply
  • Configurable by the software DEV9K
  • Galvanic isolation  on all the ways (1500 VAC)
  • Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
  • Webserver
  • Functional Block programming software
  • LED signaling for Link/Act Ethernet, serial RX-TX, power supply, digital inputs and digital outputs state
  • Configurable by the software DEV9K
  • Capable to connect the sensors to the analog inputs
  • Galvanic isolation on all the ways (1500 VAC)

Programmable pulse counter P30O, designed to convert frequency, pulse, input period, time and revolution speed signals into standard voltage or current signals. The device is programmed via PC (RS-485 interface) or with buttons.

 

Main properties:

  • 2 universal pulse inputs
  • Mathematical functions for every input
  • Individual output characteristic (up to 21 point)
  • Option – internal transducer supply source 24 VDC, 30 mA
  • RS-485 interface (protocols Modbus RTU Slave, Modbus TCP Slave)
  • Data logging function (internal 4 MB memory or SD/SDHC card (up to 8 GB))
  • Supports devices: NAT 8252, NAH 8254, NAR 8258, ECL 8439
  • Fast and easy operation via Android app “Sensor Master Communicator SMC”
  • Read out of sensor data
  • Parametrization of switich points on NAx pressure switches
  • Measuring range adjustment on submersible pressure transmitter ECL
  • Reset pressure measurement instruments to factory settings
  • Ambient temperature: 0...40 °C
  • Supply: 5 V (USB)
  • Communication: Bluetooth Low Energy
  • Designed to replace cable data transmission into aerial
  • Can be used in telemetric and information systems

Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.

  • Data visualization in WWW server
  • Convenient login from various devices (PC, tablet, phone)
  • Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
  • 1 GB Flash memory
  • E-mail messages in case of alarm occurrence
  • 2 alarm outputs or 2 binary inputs
  • RS-232, RS-485, USB, Ethernet, RTC
  • The MQTT protocol is ideal for communication in distributed acquisition systems data (IoT applications)
  • Data visualization in WWW server
  • Convenient login from various devices (PC, tablet, phone)
  • Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
  • 8 GB Flash memory
  • Real time clock (RTC)
  • 2 alarm outputs or 2 binary inputs
  • RS-232, RS-485, USB, Ethernet
  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Long-life MOS sensor
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • MOS gas sensor
  • Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
  • Standard calibration: R-404a
  • Range: 0...1000 ppm HFC
  • Resolution: 1 ppm HFC
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+60 °C
  • Supply: 11..30 VDC / 24 VAC arba 90...265 VAC

Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.

  • Ethernet connection
  • Digital inputs: 2
  • 1-Wire input (up to 2 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • Webserver
  • HTTP and XML API commands
  • E-mail alarms, SMTP, SNMP
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC

The PD9W is an industrial RS-232 / RS-485 to WiFi and Ethernet converter.

  • Communication interfaces: 1x RS485, 1 x RS232, 1x Ethernet and WiFi (802.11b/g/n)
  • Modes: AP, STA, AP + STA, AP + LAN, AP + WAN, Route and Bridge
  • Work modes: transparent transmission mode, serial port command mode, HTTP Client mode, Modbus TCP<=>Modbus RTU mode and AT command mode
  • Configuration the parameters via the WEB server
  • RS232 port for RTS/CTS signals
  • Hardware Watchdog, Heartbeat
  • Electrostatic protection 15 / 8 kV
  • Power supply: 5…36 V dc

PD9-Modbus RS485 to Ethernet converter can realize bidirectional transparent transmission between RS485 and Ethernet. It carries ARM processor, low power, fast speed, high stability. Via web-page or software, Rs-485 to Ethernet Converter can realize serial data and TCP/IP data package transparent transmission.

  • Communication interfaces: 1x RS485, 1x Ethernet WAN/LAN
  • Easy configuration the parameters via the webpage or set-up software
  • Compact size, DIN rail mount
  • Working mode: TCP server, TCP client, UDP server, UDP client
  • Modbus RTU to TCP conversion, Modbus Polling
  • DHCP support, IP dynamic or static
  • Watchdog function
  • Working temperature: -40…85°C
  • Power supply: 5…36 V dc
  • Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
  • The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
  • Introduced perpendicularly in the pipe
  • Particularly adapted for measurement in warm air, charged with particles and for high speed
  • With integrated K type thermocouple
  • Accuracy: 1 %
  • Coefficient: 0,84 ± 0,01
  • Static pressure: Atmospheric
  • Temperature of use: 0…1000 °C
  • SF6 gas monitor for high and medium voltage switchgear
  • Measurement range: 0...60 kg SF6/m3
  • Output signal: current pulses onto supply current, current loop
  • Media temperature: -40...+70 °C
  • Protection class: IP65
  • Shock proof, suitable for outdoor usage, compact
  • SF6 gas monitor for high voltage switchgear
  • Four versions: 1 / 2 / 3 / 4 stages (8716 / 8726/ 8736 / 8746)
  • Measurement range: 0...1.1 MPa
  • Output signal: floating change-over contact (SPDT)
  • Switch point: factory calibrated
  • Media temperature: -40...+80 °C
  • Protection class: IP67
  • Independent, galvanically separated circuits
  • Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
  • Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
  • 2000 VAC galvanic isolation
  • High accuracy
  • EMC compliance - CE symbol
  • Mounting on DIN rail - EN-50022 complience
  • Supply voltage: 10...30 VDC
  • Ambient temperature: -10...+60°C
  • Signal splitter DAT5022
  • Configurable with switches on body
  • 3-way galvanic isolation (2000 VAC)
  • Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
  • Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
  • Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
  • Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
  • Environment: -20...+70 °C / (non-condensing) 0-90%
  • Housing: Self-extinguishing material
  • EMC
    • Immunity: EN 61000-6-2
    • Emission: EN 61000-6-4

The P17 transducer, supplied from a current loop, converts the signal from temperature sensors or a standard voltage signal into a 4...20 mA current.

  • Ethernet 10/100 Base-T Modbus TCP interface (RJ-45 connector)
  • Configurable using webserver
  • RS-485 (Modbus RTU Master)
  • Distance up to 1200 m, up to 32 modules
  • LED indication
  • Galvanic isolation in all ways (1500 VAC)
  • EMC compliance
  • Mounting on DIN rail - EN-50022 compliance
  • Modbus Slave over RS-485
  • Modbus RTU / Modbus ASCII protocols
  • Communication parameters configurable by dip-switches
  • Watch-dog alarm
  • Remotely configurable
  • 3-way galvanic isolation (1500 VAC)
  • High accuracy
  • Mounting on DIN rail - EN-50022 compliance
  • Ethernet 10/100 Base-T interface
  • Modbus TCP server
  • Webserver for configuration of device and representation of actual input values
  • Galvanic isolation on all the ways (1500 VAC)
  • Remotely configured
  • LED indication
  • EMC compliance
  • DIN rail mounting
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution < 0,1 / 1,5 ppm SO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 2 / 5 ppm SO2
  • Attached or remote sensor
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution 0,1 / 1,5 ppm SO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...50 ppm SO2 / 0...2000 ppm SO2
  • Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265

Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.

 

  • Integrated temperature and humidity sensor
  • Calculated values – dew point temperature, absolute humidity
  • Minimal and maximal value memory
  • Isolated RS-485 port
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)
  • Patented quality product (immersion sensor patent)
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: 0 – 10 V or 4...20 mA
  • Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
  • Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
  • Medium: in liquid or gaseous media
  • For aggressive media, stainless steel immersion sleeves must be used
  • Ambient temperature: -30…+70 ºC
  • Temperature sensor TJ-B with pipe mounting
  • Measuring range: -30 to 180, 250, 400°C
  • Sensor type: RTD (Pt100, Pt1000), TC (K, J)
  • Accuracy: A or B class / cl. 2
  • Output: RTD (Pt100, Pt1000), TC (K, J), 4...20 mA, 4...20 mA +HART, 0...10 V, RS-485, IO-LINK
  • Measuring part: Plate by pipe
    • Material: Stainless steel AISI304 (1.4301) 
  • Connection head
    • Type: B
    • Protection class: IP65
  • Extension tube
    • Material: Stainless steel AISI304 (1.4301) 
    • Diameter: Ø 10 mm
    • Length: 10; 50 mm, or according to request
  • Straps: 2 pcs., not included
  • Probe for process tube: Ø 15 - 40 mm
  • Sensor: Pt100 / Pt1000 / 2x Pt100 / 2x Pt1000, 2 / 3 / 4-wire
  • Output: 4..20 mA HART / RTD / CANopen
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Fitting length: 50...1000 mm
  • Process connection: G1/2”, hygienic
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Supply: 12...40 VDC (HART), 8...40 VDC (CANopen)
  • Protection class: IP65
Loading...