Linear encoder MLS130. Very small size.
Technical specifications
- Very small measuring head (in metal enclosure)
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS210. With spiral connection and slider joints.
Technical specifications
- Protection class IP67
- Twin sliders
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS210. With spiral connection.
Technical specifications
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
The enLink Status-VC transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- 0…20 mA, 0…10 V or resistance input
- 12 bit resolution
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours
- 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
- Configuration via USB cable / downlink
- Case IP40 protection (IP 67 on request)
The enLink OAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (1.0, 2.5, 4.0 & 10), Barometric pressure, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours
- Power supply: 12…24V V DC, 0.15 Amp (max) / 4 x Li-SOCl2 (3.6V) AA / external solar panel
- Configuration via USB cable / downlink
- IP rating: IP42 (conformally coated electronics), do not expose to direct sunlight
- Operating Temp. / Humidity: -10…40 °C / 0…95 % RH (be kondensacijos)
The enLink Status-P transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- 3 channels pulse counter (S0 standard) and monitor of state (open / closed)
- With the transmit on Change of State enabled the unit operates as a standard pulse counter and also transmits a message when the state of the input changes from closed to open or open to closed
- The pulse counts for each channel are written to memory every 5 – 10 minutes
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours or adaptive (triggered by change of state)
- 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
- Configuration via USB cable / downlink
- Case IP40 protection (IP 67 on request)
The enLink Status-T transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.
- External sensor measurement range: -55…+125 °C
- Accuracy: ± 0.5 °C (-10…+85 °C)
- Up to two probes (cable length: 1 m, others on request)
- Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
- Measurement sending interval: 30 s to 3 hours or adaptive (triggered by alarm)
- 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
- Configuration via USB cable / downlink
- Each sensor can be programmed individually for different alarm type: No alarming, High threshold alarm, Low threshold alarm, In band alarm, Out of band alarm
- Each alarm type has an individual alarm status message with the following parameters: Alarm status, Total number of alarm activations, Alarm duration
- Case IP40 protection (IP 67 on request)
The Wx9xx series of sensors from COMET SYSTEM enables accurate measurement of temperature, relative humidity, and atmospheric pressure, with data transmitted via the low-power LoRaWAN network. This technology allows data to be sent to a cloud storage, where users can easily view both current and historical values through a standard web browser. Each sensor has an LCD display showing the measured value and battery status.
- Possibility to connect Pt1000 sensors
- Covers up to 15 km in rural areas and 2…5 km in urban areas
- Work with Comet System LoRaWAN gateway SP041
- Battery life: from 1 to 10 years depending on transmission time and environment temperature
- Unlimited space for data in cloud
- Alarm: email and app notification
- Mobile applications for Android and iOS
- The battery or mains powered wireless M-Bus gateway B4 is highly configurable plug-and-play device used for collecting data from Wireless M-Bus meters / sensors and transmitting the data using LTE CAT-M1 and MQTT protocol
- Long range and high sensitivity internal (or external mounted) antennas
- To maximize the battery lifetime possible configuration to listen number of minutes, specific time during day, specific days and limit number of packets stored per meter / week / day / hour
- The gateway firmware can be upgraded remotely using MQTT
- B4 series gateway can be used with Lansen R4 series repeaters and transmit additional information (see datasheet)
- Configuration can be done with: Lansen Wireless M-BUS programming dongle together with our program, Lansen Configurator, other wireless M-BUS transmitters or remotely using the MQTT protocol
- Possible to activate 128 bit AES-key encryption
- Gateway suited for harsh environments, operating temperature: -30…+85 °C, protection class: IP40, IP65 and IP67
- IoT LTE M SIM card needed (acquired separately)
- Long-lasting stainless steel screw electrodes
- Measurement range: 7...20 % (-40...+125 °C)
- Resolution: 0,1 %
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Electrode cable: FEP, -50...+200 °C, 5/10/15 m
- Timber temperature compensation
- Electrode length: 15 / 25 mm
- Supply: 11...30 VDC
- Protection class: IP68
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...5 % vol) CH4
- Resolution 0,1 % LEL (50 ppm) CH4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 / 50 % LEL CH4
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL CH4
- Resolution 0,1 % LEL CH4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 20 / 50 % LEL CH4
- Visual and acoustic alarms
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...5 % vol) CH4
- Resolution 0,1 % LEL (50 ppm) CH4
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Metal-oxide gas sensor
- Range: 0...100% LEL (0...5 %) CH4
- Resolution: 0,1 % LEL (50 ppm) CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+70 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Input: Modbus RTU – RS-485
- Output: 4-channel SPST relay contacts
- Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
- Non-volatile memory to retain and restore relay states following power outages
- Watchdog functionality for communication loss
- Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
- DIN rail mounting
- Power supply: 5…28 Vdc
- Warranty: 3 years
- The module setting can be done through USB or one of the RS-485 (master/slave) interface using the available for free eCon program
- Possibility of connection via internal RS-485 port in order to increase no of analog outputs in network
- Master Modbus function dedicated to read out data from other RS-485 devices and to scale analog value.
- Slave Modbus function to set the signal on analog outputs
- Possibility of configuration through USB without power supply
- 4 analog inputs (standard signals, RTD, thermocouple)
- RS-485 Modbus output (Slave mode)
- 2 alarm outputs
- Galvanic isolation of inputs (2 from other 2)
- Programmable individual characteristics, mathematical functions
- Programmable time counters
- Rail-mounted
2-channel binary input converter SM3 with RS-485/232 interface. Modbus RTU and ASCII.
8 binary output converter SM4 with RS-485/232 interface. Modbus RTU and ASCII.
8-channel binary input converter SM5 with RS-485/232 interface. Modbus RTU and ASCII.
- Designed for air temperature and humidity sensors / transmitters
- Transmitter entirely protected inside the shield
- Prevention of condensation by downward sensor orientation
- Advanced weather protection by maximized top cover area (Ø 250 mm)
- Passively ventilated, requires no power
- Plate system permits air flow through the sensor
- ASA plastic is resistant to mechanical damage and UV radiation. It is anti-static and very stable over time.
SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.
- Measuring elements:
- CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
- VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
- PM: Laser-based light scattering particle sensing
- Temperature: Integrated to CMOS
- Relative humidity: Thermoset polymer capacitive sensing element
- Field configurable outputs for selected measurements; Configuration possible through MODBUS
- Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
- Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
- Optional LCD-display and buttons
- Operating temperature: 0…50 °C
- Protection standard: IP20
- Electrochemical gas sensor
- Range: 0...250 ppm NO
- Resolution: 1 ppm NO
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 3 / 6 ppm NO2
- Stable long-life electrochemical gas sensor
- Range 0...20 / 0...200 ppm NO2
- Resolution 0,02 / 0,1 ppm NO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Electrochemical gas sensor
- Range:
- -- 0...20 ppm NO2
- -- 0...200 ppm NO2
- Resolution:
- -- 0,1 ppm NO2 for 20 ppm range
- -- 1 ppm NO2 for 200 ppm range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 19,5 / 18 % vol O2
- Stable long-life electrochemical gas sensor
- Range 0...20 % vol O2
- Resolution 0,01 % vol O2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Electrochemical gas sensor
- Range: 0...25 % O2
- Resolution: 0,01 % O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+50 °C
- Supply: 12...36 VDC, 24 VAC or 230 VAC
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,3 / 1 ppm O3
- Attached or remote sensor
- Stable long-life electrochemical gas sensor
- Range 0...5 ppm O3
- Resolution 0,03 % ppm O3
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...5 ppm O3
- Resolution: 0,01 ppm O3
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
The instrument uses a pH/ORP sensor and RTD Pt100 temperature sensors. If the Pt100 is connected the transmitter makes automatic temperature compensation (pH only).
- pH range: 0 ÷ 14.00 pH
- ORP range: 0 ÷ 1000 / 0 ÷ -1000 / -1000 ÷1000 / 0 ÷ 2000 / 0 ÷ -2000 mV
- Temperature range: -10.0 ÷ 110.0 °C / 14.0 ÷ 230.0 °F
- Resolution: 0.01 pH, 1 mV, 0.1 °C
- Digital output: RS-485 isolated
- Analog output: 4-20 mA galvanically isolated, "current loop" two wires
- Power supply: 9 / 36 Vdc
- Dimensions: 71x95x58 mm. Rail Din (4 modules)
- Operating temperature: 0…+50 °
- EMC/RFI conformity: EN 61326
LTC potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.
The main difference from LTM transducers is that LTC has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.
Application:
- Press Brake Machines
- Marble Machines
- Tension Control
- Horizontal Band Saw Machines
- Transfer Machines
- Hydraulic Machines
- Sheet Metal Working Machines
- Bending Presses
- Textile Machines
LTM potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.
Movement of up to 1000 mm. High resolution (0,01 mm). No additional parts such as gears are needed, because transducer construction enables the direct connection into mechanical system.
Application:
- Press Brake Machines
- Marble Machines
- Tension Control
- Horizontal Band Saw Machines
- Transfer Machines
- Hydraulic Machines
- Sheet Metal Working Machines
- Bending Presses
- Textile Machines
LTP potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.
The main difference from LTM transducers is that LTP has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.
Application:
- Press Brake Machines
- Marble Machines
- Tension Control
- Horizontal Band Saw Machines
- Transfer Machines
- Hydraulic Machines
- Sheet Metal Working Machines
- Bending Presses
- Textile Machines
Measurement of 54 power network parameters, including current and voltage harmonics up to 63rd in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems
- High accuracy class (0.2S for active energy)
- Interface: RS-485 (Modbus RTU 8N2,8E1,8O1,8N1)
- Graphical color display: LCD TFT 3,5’’, 320 x 240 pixels, fully configurable by a user (10 screens, 8 parameters in each)
- Additional 2 screens for harmonics presentation and 1 dedicated screen for visualization in the form of an analog meter
- Memory of minimum and maximum values
- 2 configurable alarm outputs
- Supervisory relay mode for alarm outputs
- Password protection
- Programming of parameters using free eCon software
- Battery backup RTC
- Supply: 85...253 V ac / 90...300 V dc
- Operating temperature: -10…23…+55 °C
- Overall dimensions: 96 x 96 x 77 mm
Power network transducer P41 is designed to convert 1-phase power network parameters into analog or digital signal. Measured parameters: voltage (U), current (I), frequency (f), active power (P), reactive power (Q), apparent power (S), power factor (PF), reactive power coefficient (tgφ), phase angle difference (φ), active energy (Ep), reactive energy (Eq).
- universal inputs (1 A or 5 A, 100 V or 400 V)
- programmable analog output ( -20 mA...+20 mA)
- parameter transfer via RS-485 interface (Modbus RTU protocol)
- chosen values memory (9000 records)
- programmable current and voltage transformer coefficients
- transducer settings are changed via „LPConfig“ software (USB)
Power network transducer P43 is designed to measure 3-phase (three or four-wire systems) power network parameters. Two parameter values are converted into analog output signal -20...+20 mA. Other parameter values are sent over RS-485 or USB ports. All parameter min and max values are measured. Data refresh interval is less than 1 s. Output signals are isolated from input and supply. Two programmable alarm outputs. Pulse (passive) output OC can be used for energy accounting. Mounted on 35 mm rail.
- Measuring ranges:
- current 1/5 A L1...L3: 0,02...6 A
- voltage L-N/L-L: 2,9...276/ 10...480 V
- frequency: 45,00...66 Hz
- active power: -1,65 kW...1,4 W...1,65 kW
- reactive power: -1,65 kvar...1,4 var...1,65 kvar
- apparent power: 1,4 VA...1,65 kVA
- power factor: -1...0...1
- active energy: 0...99 999 999,9 kWh
- sum energy: 0...99 999 999,9 kvarh
- Consumed power: ≤ 6 VA
- Transformation coefficients: Ku = 1...4000, Ki = 1...10000
- Supply: 85...253 VDC or AC 40...400 Hz
- Ambient temperature: -10...23...+55 °C
- Measuring range: -1…100 bar (see datasheet)
- Basic accuracy 0,5% of range
- Output: 4…20 mA
- Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
- Operating temperature: -20…+85 / 200 °C (see datasheet)
- Stainless steel housing and diaphragm material
- Protection class: IP67 / IP68
DPC 8380 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.
DPS 8381 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.
- Range: 0...2,5 iki 0...600 bar / 0...30 iki 0...7500 psi
- Sensor type: Thick film on steel
- Accuracy: ±0,5 %
- Output (chosen): 4...20 mA / 0...5 VDC / 0...10 VDC / 1...6 VDC
- Switching outputs: 2 x PNP
- Shown measuring units: bar, psi, MPa, kPa, m WC, mm WC
- Ambient temperature: -25...+85 °C
- Media temperature: -25...+85 °C
- Protection class: IP65
- Process connection: G1/4" m, R1/4" m, 1/4"NPT m, 1/2"NPT m
- Data logger memory: 3518 points
- Pressure range: from 0...2,5 to 0...700 bar
- Process temperature: -40...+125 °C
- Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
- Protection class: IP65, IP67
- Pressure transmitter ATM (analog output)
- Pressure measurement range: from 0 to 0,1...1000 bar
- Accuracy: < ± 0,50 / 0,25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
- Process temperature: -40...150 °C
- Operating temperature: -25..85 °C
- Materials: stainless steel, titanium
- Pressure transmitter ATM.1ST/Ex (high precision, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...1000 bar
- Accuracy: ≤ ± 0.10 / 0.05 % FS
- Output: 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -40...125 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
- Pressure transmitter ATM/Ex (for explosive Ex environment)
- Various pressure measurement ranges: 0,1...1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx, EAC
- Pressure transmitter ATM/F (hygienic)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...100 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Pressure transmitter ATM/F/Ex (hygienic, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Certificates: ATEX, EAC