- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...300 or 0...1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detected gases: hydrogen, methane, acetylene, propane, butane
- Default calibration: methane CH4
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL
- Resolution: 0,1 / 1 % LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...10 / 0...200 / 0...1500 ppm
- Resolution: 0,1 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
- Stable long-life metal-oxide sensor
- Range: 0…1000 / 0…2500 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...100 ppm, 0...2000 ppm H2S
- Resolution: 1 ppm H2S
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL CH4
- Resolution: 0,1 / 1 % LEL CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0…250 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life optical NDIR sensor
- Range: 0…1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...25 % vol O2
- Resolution: 0,01 % vol O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Highly sensitive Photo Ionization Detector (PID) sensor
- Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
- Default calibration: Isobutylene
- Range: 0…40 / 0…200 ppm isobutylene
- Resolution: 0,01 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide sensor
- Detectable gases: acetone, ethanol, toluene, xylene etc.
- Default calibration: toluene
- Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
- Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
Thermal mass flow sensor for compressed air and gases VA 500
- 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
- Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
- Optional: Bi-directional measurement
- Pressure tight up to 50 bar
- Temperature range up to 110 °C
- Protection class IP65
- Suitable for gas velocities up to 224 Nm/s
- Integrated display for showing the measured values
- Can be used from 1/2" up to 40", larger diameters on request
- Easy installation under pressure
- Settings can be changed via the display
- Main counter reading can be reset via the display
- Calorimetric measuring principle
- Units freely selectable via keys at the display
- Display shows 2 values at the same time, twistable by 180 ° degree
- Integrated Modbus interface enables connection control systems, SCADA
- M-Bus (optional)
- Analog output 4...20 mA
- Pulse output (galvanic isolation)
- High measuring accuracy (ideal for leakage measurement)
The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.
- Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
- Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Accuracy at 25°C typically: ± 0.5 % FS typ.
- Membrane in Duplex steel 1.4462
- Pressure connection: G1/2” male, flush membrane
- Media temperature –10... +125 °C
- Ambient temperature: –10...+125 °C
- Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
- Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
- Flexible control: 3 relays (SPDT, potential-free, 250 V)
- Intelligent Communication: RS-485 interface with DGC and Modbus protocol
- Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
SKU: 5905309602212
- Efento Gateway automatically transfers gathered data from Efento BLE (Bluetooth Low Energy) sensors to Efento Cloud or any other IoT platform over 4G LTE
- Gateway stores 500,000 measurements in its buffer memory in case the connection to Efento Cloud is lost, it will send the measurements right after connection is restored
- If Gateway used without Efento cloud it can store sensors data in its memory
- In local mode you can check the current and historical measurements (table/chart) and export the data in a form of CSV report
- Gateway communicates with sensors wirelessly over BLE. The maximum distance between Gateway and sensor is 100 m in the open space and 20 – 30 m in the buildings
- One gateway supports up to 128 Efento sensors
- Gateway can be integrated with any cloud platform or software that supports HTTP protocol (REST API)
- Setup takes under 5 minutes and can be completed using a smartphone with a free mobile app
- SIM card slot for LTE Cat 1 connection
- Power supply: 5 V, 1 A (USB-C)
- Backup battery: LI-Po, 1900 mAh (up to 12 hours backup power)
- Operating temperature: 0…+40 °C
SKU: 5906660327066
- Efento Gateway automatically transfers gathered data from Efento BLE (Bluetooth Low Energy) sensors to Efento Cloud or any other IoT platform
- Gateway stores 500,000 measurements in its buffer memory in case the connection to Efento Cloud is lost, it will send the measurements right after connection is restored
- If Gateway used without Efento cloud it can store sensors data in its memory
- In local mode you can check the current and historical measurements (table/chart) and export the data in a form of CSV report
- Gateway communicates with sensors wirelessly over BLE. The maximum distance between Gateway and sensor is 100 m in the open space and 20 – 30 m in the buildings
- One gateway supports up to 128 Efento sensors
- Gateway can be integrated with any cloud platform or software that supports HTTP protocol (REST API)
- Configuration of Efento Gateway using any internet browser over LAN
- Ethernet connection for data transfer
- Power supply: 5 V, 1 A (mini USB)
- Operating temperature: 0…+40 °C
- Data converter which connects reader in safe zone with network switches and temperature cables/spears in dangerous zone
- Input: 4 x temperature cables (from switches GWNET11 and cables GWSL 1100 or GWSL 2100)
- Output: Modbus RTU, RS-485
- Reads data from 68 individual temperature cables and spears
- Supply: 230 VAC / 115 VAC
- Protection class: IP66
- Certificates: IECEx, ATEX
- Works as a multiplexer, enabling 4 additional temperature cables or spears to be connected to GWAB11 converter
- Another GWNET11 can be connected in parallel, further expanding inputs of GWAB11 by 4
- Operating temperature: -20...+50 °C
- Protection class: IP66
- Certificates: IECEx, ATEX
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø9,8 mm
- Length: 1...35 m
- Tensile strength: ≤ 2,5 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø17 mm
- Length: 1...100 m
- Tensile strength: ≤ 8 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Digital inputs: 2
- 1-Wire input (up to 8 sensors)
- RS-485 input (up to 8 sensors)
- Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
- Relay outputs: 4 (NO/NC)
- Setup via USB or SMS
- Data logger for up to 52 000 records
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- SMS alarms (up to 5 numbers)
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...24 VDC
- Digital inputs: 2
- 1-Wire input (up to 4 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- Setup via USB or SMS
- Webserver
- HTTP Post, HTTP API
- SMS alarms (up to 5 numbers)
- E-mail alarms (up to 5 recipients), SMTP with TLS support
- Operating temperature: 0...40 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Enables the PC to be connected to HART interface, i.e. to configure a device
- Active operation: current loop is supplied
- Passive operation: used in an existing current loop
- Included HART-Tool software
- Supply: from USB
- Galvanic isolation between USB and HART
- Communicates with devices supporting HART and LHP interfaces
- Supports universal, common commands
- HART connector: BNC
- Supply: 9 V accumulator (charged via USB)
- Operating temperature: -20...+50 °C
- Operating humidity: 0...80 % RH
- Protection class: IP40
- Temperature measurement range: 0...50 °C
- Humidity measurement range: 0...100 %
- Output: 2 x 0...10 V / 2...10 V / 4...20 mA
- Option: LCD display
- Option: relay output
- Option: Modbus RTU
- Supply: 24 VDC/VAC
- Operating temperature: 0...50 °C
- Protection class: IP20
- Temperature measurement range: 0...50 °C
- Humidity measurement range: 0...100 %
- Output: 2 x 0/2...5/10 VDC
- Option: LCD display
- Option: Modbus RTU
- Supply: 24 VDC/VAC
- Operating temperature: 0...50 °C
- Protection class: IP54
- Temperature measurement range:
a) Ambient model: -20...+80 °C
b) Remote model with polycarbonate probe: -20...+80 °C
c) Remote model with stainless steel probe: -40...180 °C - Relative humidity measurement range: 0...100 %
- Calculates dew point, absolute humidity, enthalpy and combination ratio
- 4-wire analog output: 0...5/10 V or 0/4...20 mA
- 2 relay outputs
- Versions with or without display
- Protection class: IP65 (ABS V0 housing)
The P18L transducer is a device destined for the continuous measurement and conversion of relative humidity and ambient temperature into a standard analog signal 4...20mA.
- P18L transducer is supplied from a current loop.
- Applied sensor shields enable the application of the P18L transducer to operate in various ambient conditions.
- SF6 gas density monitor for high voltage switchgear
- Three versions: 1 / 2 / 3 stages (8781 / 8782 / 8783)
- Measurement range: 0...1,1 MPa (mechanical), 0...0,85 MPa (electronic)
- Output signal: floating change-over contact (SPDT) / 6.5...20 mA current loop
- Switch point: factory calibrated
- Media temperature: -40...+80 °C
- Ambient temperature: -40...+80 °C
- Protection class: IP65
- Long-life metal-oxide gas sensor
- Range 0...100 % LEL H2
- Resolution 0,1 % LEL H2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor options
- Hydrogen pressure transmitter’s measuring principle: Thin-film-on-steel
- EC79 and ECER-134 certification pending (see product website for current situation)
- Applications: Fuel cells, fueling stations, hydrogen compressors, hydrogen tanks, vehicles with H drive
- Measuring range: 0…1050 bar / 0…15000 psi *(see product datasheet)
- Measuring accuracy at 25 °C typ.: ± 0.3 / 0.5 % FS typ.
- Output signal: 4...20 mA, 0.5...4.5 VDC, 0...5 VDC, 1...5 VDC, 1...6 VDC, 0...10 VDC, 0.1...10.1 VDC, 0.5...4.5 VDC ratiometric, Switching output: 1 or 2 PNP
- Pressure connections: G1/4" m, 1/4"NPT m, 7/16"-20UNF SAE4 m
- Ambient temperature: 40°C…+85°C
- Stable long-life electrochemical gas sensor
- Range 0...100 / 0...1000 ppm H2S
- Resolution 0,1 / 1 ppm H2S
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 10 / 20 ppm H2S
- Stable long-life electrochemical gas sensor
- Range 0...100 / 0...1000 ppm H2S
- Resolution 0,1 / 1 ppm H2S
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor option
- Electrochemical gas sensor
- Range: 0...100 / 0...2000 ppm H2S
- Resolution: 0,1 / 1 ppm H2S
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -40...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Suitable for thick and viscous media
- Different materials for optimum media compatibility
- EMC protection class is IEC 61000 (lightning, electrical discharge)
- Range: 0...0,1 bar to 0...6 bar
- Accuracy: +/- 0.3 %
- Output: 4...20 mA
- Ambient temperature: -25°C...+70 °C
- Process temperature: -25°C...+70 °C
- Supply: 9...32 VDC
- Protection class: IP68
- Material: Stainless steel (1.4404 (316L) / 1.4462 (318LN))
- Sensor technology: Thick film on ceramic
- Sensor material: Ceramics, Al2O3 96%
- Cable insulation: PUR / Radox / PE
- Universal input (for standard signals and temperature sensors)
- Alarm output
- OLED display
- Configuration via miniUSB connector
- Supply: 24 VDC or 230 VDC / VAC
- IP65 protection class
- Measurement of parameters: voltage, current, active, reactive and apparent power, cosφ, tgφ, frequency, active, reactive and apparent energy, active power 15 minutes, voltage 10 minutes
- Current and voltage harmonics analysis up to 51st (measurements available via RS-485)
- Programmable input:
- Current: 0…1 / 0…5A
- Voltage: 0…100V / 0…230V / 0…400V
- Output:
- Analog: 0/4...20 mA or 0...10 V
- Relays: 1 or 4
- Binary (OC)
- Digital output: RS-485 modbus (can be programmed through RS-485)
- Two-line LCD display
- Pulse output to measure energy consumption
- 4 alarm outputs with signaling on LED diodes, working in 7 different modes
- Conversion of any measured value into an analog signal 0/4...20 mA or 0...10V
- Protection grade: frontal side – IP65 / from terminal side – IP10
- Operating temperature: -25...23...55 °C
Industrial IoT module TCW242 for remote real-time monitoring and control of industrial equipment, facilities, production lines, renewable energy systems, greenhouses and water stations
- Web-based configuration and control with password protection
- 4 digital inputs for dry contacts
- 4 analog inputs with 0-10V and 0-20mA options
- 4 relays with normally open/normally closed contacts
- RS-485 interface for MODBUS RTU sensors. Up to 24 sensors (registers)
- Monitor up to 24 channels
- Set up to 24 independent alarms
- SNMPv3 protocol support
- Alarm notifications via SNMP traps
- NTP protocol support
- HTTP API commands
- 4 schedules for real-time control of relay outputs
- Custom logical functions
- Secured email transfer with TLS 1.0, TLS 1.1, and TLS 1.2 support
- Data logging capacity for up to 70,000 records
- Dynamic DNS support for DynDNS, No-IP, and DNS-O-Matic providers
- Periodical HTTP / HTTPS Post of XML / JSON status files for client-server systems
- MODBUS TCP / IP protocol support
- MQTT 3.1.1 protocol support
- Rugged DIN-Rail / wall-mountable enclosure
- Operating temperature range: -20…+55 °C
- Industrial pressure transmitter’s measuring principle: Thin-film-on-steel
- Applications: hydraulics, industrial applications, machine tools
- 5-fold overpressure resistance
- Measuring range: 0...2.5 / 0...700 bar // 0...30 / 0...10000 psi
- Measuring accuracy at 25 °C typ.: ± 0.5 % FS typ. ± 0.3 % FS typ
- Output signal: 4...20 mA, 0...5 VDC, 0.5...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Ambient temperature: -40°C…+125°C
- Ethernet connection
- Digital inputs: 2
- 1-Wire input (up to 2 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- IP watchdog function
- Webserver
- SNMP alarms
- VLAN and MAC address filtering
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- For galvanic separation of current signal between explosive (Ex) and normal areas
- Input: 0...20 mA, 4...20 mA
- Output: 0...20 mA, 4...20 mA, version with 0...10 V
- Version with support for HART signal
- DIN rail-mounted
- Supply: 24 VDC / 230 VAC
- Operating temperature: -20...60 °C
- Protection class: IP20
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (in range: 0...100 m/s) and flow m3/h
- Sheathed thermocouple K probe integrated, with connection cable length 1,5 m (option)
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- Accuracy: Better than 1 % for an alignment in relation to the flow axis of the fluid of ± 10 °
- Coefficient: 1,0015 ± 0,01
- Max static pressure: 2 bar
- Temperature of use: 0…600 °C (up to 1000 °C in option)
The new leak meters LD 500/510 with integrated camera and leakage calculation are ideal to find even smallest leakages (0.1 l/min) easily even in far distances and calculate potential saving (€/year).
- 30 MEMS digital microphones for image of leaks
- Measuring distance: up to 6,5 m
- 3,5” TFT color display with touch panel
- Additional sensor input to measure: dew point, flow, pressure, and temperature (LD 510 only. See datasheet)
- Possibility to take photo of leaking parts
- Data transfer via USB to PC
- Easy data and work assignment with CS Leak Reporter cloud solution
- ISO 50001 report
- Power supply: 7,2 V lithium-ion battery (> 9 h continuous operation)
- Operating temperature: -5…+40 °C
- Incremental encoder output: A, B / A, B, Z / A, /A, B, /B / A, B, Z, /A, /B, /Z
- Resolution: 5 / 10 / 25 / 50 μm
- Magnetic measurement (contactless, non-friction system)
- Vibration-resistant
- Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
- Supply: 10...30 VDC / 5 VDC
- Operating temperature: -25...+85 °C
- Protection class: IP67
- Incremental encoder output: A, B / A, B, Z / A, /A, B, /B / A, B, Z, /A, /B, /Z
- Resolution: 5 / 10 / 25 / 50 μm
- Portable reference point
- Stroke values up to 2000 mm
- Vibration-resistant
- Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
- Supply: 10...30 VDC / 5 VDC
- Operating temperature: -25...+85 °C
- Protection class: IP65
Linear encoder MLS110. With cable connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With spiral connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS120.
Technical specifications
- Casing integrated into slider
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC