This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:

The device is designed to measure ambient air pollution by detecting concentration and distribution of particles.

  • Įėjimas: Pt100, Pt1000, 0…4000 Ω, TC (E, J, K, N, R, S), -75…310 mV, -10…10 V, -24…24 mA, potenciometras
  • Relinė išėjimas: 1 x NO kontaktas, apkrovos galia 6 A / 250 V AC; 6 A / 30 V DC
  • Skaitmeninis išėjimas: RS-485 / MODBUS RTU
  • Išorinio įrenginio maitinimas: 24 V DC / 24 mA
  • Matematinės funkcijos matavimo reikšmės konvertavimui
  • Dviejų eilučių LCD ekranas (1 eilutė – 6 skaitmenys, 2 eilutė – 5 skaitmenys)
  • Apsaugos klasė: priekio – IP65 / galo – IP10
  • Darbinė temperatūra: -20...23...60 °C
  • Maitinimas: 40…253 V AC / 20…300 V DC
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...5 % vol) CH4
  • Resolution 0,1 % LEL (50 ppm) CH4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 / 50 % LEL CH4
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL CH4
  • Resolution 0,1 % LEL CH4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 / 50 % LEL CH4
  • Visual and acoustic alarms
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...5 % vol) CH4
  • Resolution 0,1 % LEL (50 ppm) CH4
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Metal-oxide gas sensor
  • Range: 0...100% LEL (0...5 %) CH4
  • Resolution: 0,1 % LEL (50 ppm) CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Range: -250...2550 Pa
  • Maximal overpressure: 30 kPa
  • Accuracy: ±1,4 %
  • Pressure and air flow measurements from air diffusers and valves
  • Data can be uploaded on your computer for visualization and further analysis
  • Over 700 programmed valve types
  • Mediums: air and non-aggressive gases
  • Operating temperature: -10... +50 °C
  • Connection: ø 5 mm pressure hoses
  • Can be used with Pitot tube
  • 5 year warranty
  • Included: calibration certificate, 2 x 2 m PVC hoses

TSM400-4-CP is a multi parameters sensor that supports MODBUS RTU protocol over the RS-485 interface. The sensor measures barometric pressure and CO2 concentration.. Suitable for environmental quality monitoring, indoor air, smart ventilation systems, restaurants and breweries CO2 level and CO2 leakage control.

  • Changeable bitrate and other communication parameters
  • Non-volatile memory for all setting
  • CO2 measurements range: 400…5000 ppm
    • Accuracy: ± (40 ppm + 5 %)
    • Resolution: 1 ppm
    • Calibration: Automatic, if the sensor is exposed to fresh air for more than 30 minutes
  • Pressure measurements range: 10…1200 hPa
    • Accuracy (min): ±1.5 (25°C, 750 hPa)
    • Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
    • Resolution: 1 hPa
  • Operating temperature range: -20…+60°C
  • Operating relative humidity range: 5…95% (non-condensing)
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC
  • Input: Modbus RTU – RS-485
  • Output: 4-channel SPST relay contacts
  • Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
  • Non-volatile memory to retain and restore relay states following power outages
  • Watchdog functionality for communication loss
  • Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years
  • Moisture reading range:
    • 4…18 % for Lint cotton
    • 6…20 % for Seed cotton
    • 12…30 % for Wool
    • 6…25 % Viscose / Rayon
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app. timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 20,40 x 7.24 x 4.06 cm
  • Weight: meter only: 218 gr
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
  • Moisture reading range:
    • Hay: 6…40 %
    • Hops: 8…23 % (FX-30)
    • Hemp: 7…34 % (FX-30)
    • Tobacco: 8…37 % (FX-30)
    • Brazil Nuts: 6…25 % (FX-30)
    • Dates: 6…25 % (FX-30)
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app (FX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app FX-30)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 20,40 x 7,24 x 4,06 cm
  • Weight: meter only: 218 gm
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration

The JX-30 features the Delmhorst EDGE™ App with expanded wood species, customizable settings, and the ability to share data from any location.

  • Moister measurement range: 6…60% Wood (Douglas Fir)
  • Large, custom display with auto backlight – easy to read under all conditions
  • Species: 74 plus 123 additional available through EDGE™ App
  • Wood temperature correction (°F/°C)
  • Pins/electrode correction (insulated or non-insulated)
  • Alarm set point: alerts to user-selected moister level
  • On-screen statistics: High, Low, Average, Standard Deviation, View all readings
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer. Set to 1 min, 4 min or 10 min
  • Integral contact pins max 5/16” penetration (use 2498/A-100)
  • Compatible with any Delmhorst external electrode
  • Color-coded LED’s: adjustable through EDGE ™app
  • Power: 2x AA batteries – Alkaline Energizer (included)
  • QR code on meter for easy access to support materials
  • Size: meter only: 220 mm x 72mm x 39mm; in carry case - 241mm x 165mm x 64mm
  • Weight with case: 510 g
  • Moisture reading range:
    • 4,3…18 % moisture for paper (kraft paper calibration)
    • 5…40 % for baled scrap paper (PX-30)
    • 0…100 reference scale for obtaining relative moisture levels on other materials without calibration (PX-30)
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app (PX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app PX-30)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 21.97 x 7.24 x 4.06 cm
  • Weight: meter only: 218 / 244 gm
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
  • Paper moisture and temperature meter WCPT-100P, made by Tanel (Poland)
  • Moisture range: 20...95 %RH; Ambient temperature: -5...+60 ºC
  • Mounting brackets for easy installation of temperature sensors in measuring point
  • UZ11 – full bracket
  • UZ21 – bracket without body (only flange)
  • Diameter: 15 / 22 / 32 mm
  • Body and flange material: 1.0401 steel
  • Sealing part material: Teflon / glass fiber
  • High quality
  • Complies with DIN EN 50 446

The Triton ULTRA is a multifunctional vape sensor capable of detecting e-cigarette vapor, marijuana smoke (THC), smoking, loitering, the number of people, gunshots, loud noise, and glass breakage.

  • Measured parameters: Temperature, humidity, PM1.0, PM2.5, PM10, TVOC, CO2, NO2, CO, HCHO, sound level
  • Customizable instant alarms based on the situation: Email notification, loud alarm, lights, *integration
  • Tamper protection: device vandalism, masking and covering
  • Real-time monitoring of student loitering via live video streaming
  • No license subscription required for use
  • The sensor independently performs all measurements and detections and sends alarms itself
  • *Integration capability with many third-party systems: TCP, HTTP, MQTT, RTSP
  • Event logging of alarms in the device
  • Communication: LAN, WiFi
  • Operating environment temperature / humidity: 0...44 °C / 0...90% RH (non-condensing)
  • Power supply: PoE+ (IEEE 802.3at Class 3 compliance). Ability to connect up to 4 devices in series
  • Designed for air temperature and humidity sensors / transmitters
  • Transmitter entirely protected inside the shield
  • Prevention of condensation by downward sensor orientation
  • Advanced weather protection by maximized top cover area (Ø 250 mm)
  • Passively ventilated, requires no power
  • Plate system permits air flow through the sensor
  • ASA plastic is resistant to mechanical damage and UV radiation. It is anti-static and very stable over time.
  • Temperature sensor: HQ digital internal or optional external sensor*
  • Temperature measurement range: -30...+70 °C (-40...+90 °C with ext T sensor) (-80...+200 °C with ext Pt100 sensor)
  • Accuracy: ±0.3 °C (-20...+40 °C); ±0.5 °C
  • Memory: 60,000 values ​​(up to 6 months)
  • Display: multifunction LCD
  • Battery: CR2450 3V
  • Dimensions: 100mm x 53mm x 12mm (L x W x H)
  • Weight: 54 g
  • Protection class: IP65
  • Automatic PDF, CSV reporting: Yes
  • Connection interface: USB 2.0, A-Type
  • Temperature sensor: HQ digital temperature/ relative humidity internal or optional external sensor
  • Temperature measurement range: -30...+70 °C (-40...+90 °C with ext T sensor) (-80...+200 °C with ext Pt100 sensor)
  • Temperature accuracy: ±0.3 °C (-20...+40 °C); ±0.5 °C
  • Humidity measurement range: 0...100 % rH
  • Humidity accuracy: ± 3 % rH (20...80 %), 5 % kitur (25 °C)
  • Memory: 60,000 values ​​(up to 6 months)
  • Display: multifunction LCD
  • Protection class: IP65
  • Automatic PDF, CSV reporting: Yes
  • Connection interface: USB 2.0, A-Type

Multifunction astronomical digital clocks RDT-TPA2 are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise.

  • 80 programs (astronomical and annual), holiday mode, random mode
  • Automatic summer/winter digital clockover
  • Automatic transfer of weekdays
  • Sealable cover of the front panel, easy setting by 4 buttons
  • Backlighted LCD display (can be turned off)
  • 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
  • Number and type of contacts: 2 CO (each channel can be assigned an individual program)
  • Rated load: 16 A / 250 V AC
  • Direct mounting on 35 mm rail mount acc. to EN 60715
  • Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS
  • Measured parameters (with respective sensors):
    a) Temperature (Pt100 or thermocouple)
    b) Humidity
    c) Air quality
    d) Air velocity
    e) Airflow
    f) Tachometry
  • Two inputs for Pt100 temperature sensors (range -200...600 °C)
  • Up to 6 measurements simultaneously
  • Power supply: Lithium-Ion battery (up to 57 hours)
  • Calibration certificate, additional battery, transport case included
  • Operating temperature: 0...50 °C
  • Protection class: IP54
  • Display: LCD 6-digit, 9 mm; LED 6-digit, 7,6 mm
  • Sampling frequency: 5 kHz / 30 Hz
  • Display: LCD, 2-row (1 row 9.3mm / 2 row: 7,2 mm)
  • Sampling frequency: Up to 60 kHz

SIRO is an indoor air quality transmitter with a modern design. The transmitter is available with several optional air quality sensors. The modular device can be equipped with CO2 concentration and VOC (Volatile Organic Compounds) measurements or alternatively PM (Particulate Matter) measurement, and in addition, temperature and humidity measurements. SIRO-MOD series models use Modbus serial communication protocol.

  • Measuring elements:
    • CO2: Non-dispersive infrared (NDIR); 0...2000 ppm
    • VOC: Complementary Metal Oxide Semiconductor (CMOS); range: * - see datasheet
    • PM: Laser-based light scattering particle sensing
    • Temperature: Integrated to CMOS
    • Relative humidity: Thermoset polymer capacitive sensing element
  • Field configurable outputs for selected measurements; Configuration possible through MODBUS
  • Proportional output options including voltage (0–10 V, 0–5 V, 2–10 V) and optional current (4–20 mA); MODBUS
  • Offset feature enabling field calibration for each measurement parameter (CO2, VOC, PM, RH, T)
  • Optional LCD-display and buttons
  • Operating temperature: 0…50 °C
  • Protection standard: IP20
  • 10 time functions. With control signal and without additional signal
  • 10 time ranges. Ranging from 0,1 sec. to 30 hours
  • Operating voltage: 12…240 V AC / DC
  • Operating power: < 4 VA
  • Mounting on DIN rail
  • Operating temperature: -20…+55 °C

The AUREGIS LJ-VD4M12 multi-zone floating, stainless steel level relay with standard M12 connector is designed for liquid level measurement and regulation.

  • Connection connector: M12 (4 / 8 pins)
  • Floats and float holders are customizable (on request)
  • Connection thread: G3/4" or larger (on request)
  • Switching power: 25 VA
  • Switching voltage: 24 V AC/DC
  • Process part operating temperature: -30...+105 °C
  • Process part: Stainless steel AISI316L
  • Protection class: IP65
Multipoint thermocouple temperature sensor TTP-328 is designed for temperature measurement. Suitable for energetics, oil and chemistry industries Every sensor is made out of mineral-insulted cable Process connection is threaded or flanged Compact design Maximum immersion depth is 30 m ATEX design Various variants are possible, depending on client’s request Every sensor can be mounted by up to 24 temperature transmitters. In order to bring the start-up cost down, sensor can be configured by our company. More on TTP-328 multipoint thermocou..
  • Electrochemical gas sensor
  • Range: 0...250 ppm NO
  • Resolution: 1 ppm NO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 3 / 6 ppm NO2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range:
  • -- 0...20 ppm NO2
  • -- 0...200 ppm NO2
  • Resolution:
  • -- 0,1 ppm NO2 for 20 ppm range
  • -- 1 ppm NO2 for 200 ppm range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Infrared temperature meter KIRAY 100 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.

  • Noncontact infrared temperature meter 3i Plus (pyrometer), designed for metalworking industry where casting, hardening, heating take place. Also suitable for ceramics, semiconductor, chemical furnace temperature measurement
  • It is a new generation, small size IR device for high temperature measurement
  • Precise high-resolution optics guarantee high accuracy, resistant casing let the device survive falls from up to 1 meter height
  • That said, measurements can be done in various environments and from various distances
  • Noncontact stationary infrared temperature meter CM for temperature measurement
  • Range: -20...500 °C
  • Outputs: 0...5V, or TC K / J type (chosen while ordering)
  • Software “DataTemp Multidrop” for remote monitoring and configuration
  • Noncontact infrared thermal meter (pyrometer) ENDURANCE
  • for temperature measurement up to 3200 ºC with the resolution of 0,1 ºC
  • Outputs: Ethernet, profinet, 0/4...20mA (isolated), RS485, relay 48V and 300mA
  • Web server
  • Wider area can be measured when used with SpotScan
  • Noncontact infrared thermal meter Marathon MM, wide range of accessories for various applications
  • Range: -40...3000°C (in fixed ranges)
  • Outputs: 0/4...20mA, RS485, mechanical switch
  • Noncontact infrared thermal meter Thermalert TX, additional accessories for various applications
  • Can be used in an explosive area
  • Range: -18...2000 °C (in fixed ranges)
  • Outputs: 4...20mA, HART į RS232, mechanical switch (depends on version)
  • OilSET-1000 is designed for oil detection in separators, basins and tanks
  • Easy to install, does not need calibration
  • 2 switch outputs
  • Ultrasonic sensor SET/S, 5 meter cable
  • ATEX certified
  • Wall-mounted, IP67
  • Supply: 230 VAC, 50/60 Hz

The innovative Leybold SOGEVAC B single-stage oil sealed rotary vane pumps are ideal for modern industrial applications distinguished by low noise levels, high pumping speeds and high reliability.

  • Compact design and small footprint
  • No motor coupling up to SV65 B
  • Very low oil emission
  • State of the art sealing technology
  • Very low noise level in any working condition
  • Customized configurations possible
  • Simplified maintenance and service

SOGEVAC B pumps have a pumping capacity range from 10 to 750 m3/h @ 50 Hz with an ultimate pressure of ≤ 8 X 10-2 mbar.

Industry proven double stage rotary vane pumps with a performance driven and low noise design.

Leybold TRIVAC B oil sealed double stage vane pumps are well known and being used in all areas of vacuum engineering and are equally suited for both industrial production and research applications. The TRIVAC B pumps, used to generate a rough and medium vacuum or as backing pumps in pump combinations with Roots vacuum pumps or high vacuum pumps, have the ability of pumping down from the atmosphere.

  • Compact design and small footprint
  • No motor coupling up to SV65 B
  • Very low oil emission
  • State of the art sealing technology
  • Very low noise level in any working condition
  • Customized configurations possible
  • Simplified maintenance and service

The TRIVAC B range is available in six different sizes with an ultimate pressure of 10-4 mbar and a pumping speed in the range of 4 m3/h to 65 m3/h.

Industrial vacuum pumps for the rough vacuum industry.

The CLAWVAC series of oil-free industrial dry vacuum pumps have a corrosion-resistant pump chamber and stainless-steel claws. This makes them extremely robust, especially for challenging applications which include handling of particles and vapor-contaminated gases. The CLAWVAC dry vacuum pumps are simple to use, easy to clean onsite and have efficient air cooling that let’s our customers experience a trouble-free and cost-saving operation.

CLAWVAC can replace your liquid ring vacuum pump.

Thanks to its unique design, CLAWVAC combined with the right Leybold accessories can replace a liquid ring vacuum pump in many processes.

Switch to dry claw technology for cost savings:

  • Huge cost savings: no water consumption, no water treatment or disposal
  • Lower power consumption
  • Stable process performance, independent of water temperature
  • Better environmental impact of your industrial plant, as water is a valuable asset
  • The dry vacuum pumps of the SCROLLVAC plus family operate on the principle of a scroll compressor
  • A scroll pump consists of two engaged spiral forms. One scroll form is mounted eccentrically to the other and is made to move in an orbiting path relative to the fixed scroll. This creates crescent shaped volumes that are driven from the outside to the inside of the forms thereby pumping the gas
  • Increased pumping speed combined with low ultimate pressures, low power consumption and low noise levels
  • Gas ballast allows for pumping of condensable vapors including water, solvents, dilute acids, and bases
  • Latest in tip seal technology: allows for significantly longer intervals between tip seal changes
  • Integrated smart drive with auto sensing voltage input, delivers optimized pumping performance globally
  • Designed to be field serviceable
  • ATEX certified to meet the requirements of group II category 3 equipment (ATEX II 3 G c IIB T4 internal)
  • CE, CSA/UL approved
  • A great choice for general laboratories, light industrial and research applications, as well as certain chemical applications
ORP electrode sensors (glass, epoxy body and submersible) Hовый

ORP electrode sensors (glass, epoxy body and submersible)

The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.

  • 30 - 365 days (1TB - 8TB) of onboard storage
  • Redundant cloud backup and unlimited cloud-based archiving of footage
  • Sensor Resolution: 4 x 5MP (2688 x 1944)
  • Protection class / Impact rating: IP66 / IK10
  • Operating temperature: -40…+50 °C
  • Warranty: 10 Years
  • Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant
Overload protector 05-04. Designed to protect pressure measuring devices from too fast or too big step change of pressure. This device blocks bigger than expected pressure until system gets back into normal state. Technical specificationsMaximum working pressure: 400 bar;Process connection: 1/2 BSP MxF, 1/2 NPT MxF, 1/4 BSP MxF, 3/8 BSP MxF, 3/8 NPT MxF;Material of construction: AISI 316 SS;Operating temperature: -40°C .. 120°C;  05-04 datasheet [EN] ..

Applications:

Surge protection for 2 pair lines or 4 single lines with common reference potential in the data, signal and communication systems: 0-20 mA, 4-20 mA current loop, TTY 4-20 mA, TTY, TTL, V24 (RS232C), high-frequency transmission system.

Specifications:

  • ANSI / IEEE C62.41 category: B, C
  • Rated operating voltage Un 24 V DC
  • Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
  • Rated load current at 25°C IL 1 A
  • Nom. discharge current (8/20 μs) In 10 kA
  • Max. discharge current (8/20 μs) Imax 20 kA
  • D1 current impulse (10/350 μs, per line) 2,5 kA
  • Voltage protection level Up:
    • at In, C2 (8/20 μs, line-line, line-PG) ≤ 55 V
    • at C3, 1 kV/µs (line-line, line-PG) ≤ 48 V
  • Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019

Applications:

surge protection for 2 pair lines of closed circuit (loops) in the data, signal and communication systems: 4-20 mA current loop, analog/digital communication, RS485, RS422 (V11) interface, high-frequency bus system, 2 wires video transmission system.

Specifications:

  • ANSI / IEEE C62.41 category: B, C
  • Rated operating voltage Un 24 V DC
  • Max. continuous operating voltage Uc 33 V DC / 23,3 V AC
  • Rated load current at 25°C IL 1 A
  • Nom. discharge current (8/20 μs) In 10 kA
  • Max. discharge current (8/20 μs) Imax 20 kA
  • D1 current impulse (10/350 μs, per line) 2,5 kA
  • Voltage protection level Up:
    • at In, C2 (8/20 μs, line-line) ≤ 55 V
    • at In, C2 (8/20 μs, line-PG) ≤ 500 V
    • at C3, 1 kV/µs (line-line) ≤ 48 V
    • at C3, 1 kV/µs (line-PG) ≤ 600 V
  • Compliance with standards: EN 61643-11:2012, EN 61643-21:2001+A1:2009+A2:2013, EN 61643-31:2019
Loading...