The principle of operation of this instrument is based on a high frequency band, enabling a very accurate detection of the level of media with a small emitting angle.
- Radar level transmitter TLR designed for accurate level measurement in liquids and solids
- Reflection removal mode
- High frequency band: 77-81 GHz
- Measuring range: 10, 20, 30, 50 m
- Measuring accuracy: 2 mm
- Output signal: 4…20 mA, Modbus RS485, Hart protocol
- Bluetooth app for programming and settings
- Process temperature: -20…+200 °C*
- Process connection: Threads G 1 ½, G 1 ½ / 2, G 2 and customized flanges for all models*
- Process pressure: -1…+16 bar*
- Protection class: IP67
Destined for direct (up to 63A) and indirect measurements in 3 phase 4 wire/3 wire balanced and unbalanced systems. For direct (up to 63A) and indirect measurement (x/1A or x/5A). Indications considering values of programmed ratios.
Reactive power controller RMB-10S. The device is designed for reactive power compensation battery control. Version with 6 switch outputs is available.
- The MQTT protocol is ideal for communication in distributed acquisition systems data (IoT applications)
- Data visualization in WWW server
- Convenient login from various devices (PC, tablet, phone)
- Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
- 8 GB Flash memory
- Real time clock (RTC)
- 2 alarm outputs or 2 binary inputs
- RS-232, RS-485, USB, Ethernet
SI-COLO3 and SI-COLO4 series sensors operate by using 3-color-range method.
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- MOS gas sensor
- Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
- Standard calibration: R-404a
- Range: 0...1000 ppm HFC
- Resolution: 1 ppm HFC
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+60 °C
- Supply: 11..30 VDC / 24 VAC arba 90...265 VAC
- Ethernet connection
- Digital inputs: 2
- 1-Wire input (up to 2 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- Webserver
- HTTP and XML API commands
- E-mail alarms, SMTP, SNMP
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- TC Monitor is remote monitoring software that collects data and controls your TCG (GSM) and TCW (Ethernet) Teracom I/O modules
- User-friendly WEB interface for easy configuration and control
- Free version let monitor up to 10 items
- The monitored parameters can be sensors, digital and analog inputs and relay outputs
- Graphical and Data dashboards for better visualization
- TC Monitor allows flexible administration of user accounts
- Easy access to the raw data tables, export in .csv format
- Alarm notifications
- User activities log
- Ethernet connection
- Digital inputs: 2
- Relay outputs: 2 (NO/NC)
- Webserver
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- Molded epoxy resin protects against aggressive environmental factors
- Primary current: 60...160 A or 200...320 A
- Secondary current: 1 A or 5 A
- Hole diameter: 30 mm or 50 mm
- Hole depth: 50 mm or 40 mm
- Accuracy class: 1
The RUVAC WH / WHU series pumps are high throughput, hermetically sealed, water-cooled roots blower pumps with high efficiency motors that provide optimum price-to-performance ratio. Both motors and oil reservoirs are water cooled thereby perfectly balancing the internal temperature management of the pumps.
RUVAC WHU pumps are equipped with a bypass line and may be operated at its maximum power from atmospheric pressure. The WHU is equipped with improved valve technology for maximum efficiency in short cycle operation. The integrated bypass line allows for the WHU pumps to be operated starting at atmospheric pressure while the unique control flap provides extreme contamination resistance.
- Output relay: SPDT / 3A / 250VAC
- Application: level sensing for solids and powder
- Speed: 1 RPM
- Supply: 24 VDC or 220 VAC
- Operating temperature: - 10...+ 70 °C
- Operating pressure: - 0,6...+ 0,6 bar
- Protection class: IP66
- LW and LE series of current transformers with a round hole for a cable
- Ranges of primary current from 50A up to 5000A
- Maximum operating voltage 0,72 kV
- Secondary current: 1A or 5A
- Accuracy classes: 0.2S, 0.2, 0.5S, 0.5, 1; 3
- Terminals of the secondary circuit are protected by cover that protects them against accidental contact
- Operating temperature: -10…+55 °C
The PD9W is an industrial RS-232 / RS-485 to WiFi and Ethernet converter.
- Communication interfaces: 1x RS485, 1 x RS232, 1x Ethernet and WiFi (802.11b/g/n)
- Modes: AP, STA, AP + STA, AP + LAN, AP + WAN, Route and Bridge
- Work modes: transparent transmission mode, serial port command mode, HTTP Client mode, Modbus TCP<=>Modbus RTU mode and AT command mode
- Configuration the parameters via the WEB server
- RS232 port for RTS/CTS signals
- Hardware Watchdog, Heartbeat
- Electrostatic protection 15 / 8 kV
- Power supply: 5…36 V dc
PD9-Modbus RS485 to Ethernet converter can realize bidirectional transparent transmission between RS485 and Ethernet. It carries ARM processor, low power, fast speed, high stability. Via web-page or software, Rs-485 to Ethernet Converter can realize serial data and TCP/IP data package transparent transmission.
- Communication interfaces: 1x RS485, 1x Ethernet WAN/LAN
- Easy configuration the parameters via the webpage or set-up software
- Compact size, DIN rail mount
- Working mode: TCP server, TCP client, UDP server, UDP client
- Modbus RTU to TCP conversion, Modbus Polling
- DHCP support, IP dynamic or static
- Watchdog function
- Working temperature: -40…85°C
- Power supply: 5…36 V dc
Temperature regulator SCD210 is designed for temperature control in various devices and rooms. Made in three variants with different inputs. SCD210 has a step set point (SP) value change by signal option in binary input.
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
- The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- With integrated K type thermocouple
- Accuracy: 1 %
- Coefficient: 0,84 ± 0,01
- Static pressure: Atmospheric
- Temperature of use: 0…1000 °C
- Digital input: 4 ch. pulse
- Independent modes: OPEN / CLOSED (“Dry contact”) and COUNTER (S0 standard)
- Output: RS-485 MODBUS RTU interface
- Non-volatile memory for counters storage and settings
- Galvanically isolated inputs
- DIN rail mounting
- Protection class: IP40 (connections IP20)
- Operating temperature range: -20…+60 °C
- Power supply: 5…28 VDC
- Designed to measure the moisture of wood, sawdust, shavings, chips, straws and hay
- Moisture measurement method: resistive
- Sawdust moisture range: 8...30 %
- Hay moisture range: 8...25 %
- Sample size: 120 cm3
- Sample compression pressure: 0,2 MPa
- Portable wood moisture meter WTR-1E (needle), designed for moisture measurement from 6 to 100 %
- Designed to measure the moisture of wood, sawdust, scobs, shavings, slivers
- Moisture measurement method: resistive
- Moisture measurement range: 8...50 %
- Step value: 0,1 %
- Sample size: 120 cm3
- Sample compression pressure: 0,2 MPa
- Display: LCD
- Supply: 12 V battery
- Modern SCADA system
- Free license allows to work with up to 50 objects (each having 10 variables / tags / atoms)
- Free license supports only one chosen driver (i.e. Modbus)
- Hardware-independent, communicates with all major industry-standard
- Mobile application (in full version)
- 25 year experience in the marketplace - developed by 7-Technologies which belongs to Schneider Electric
- Up to 60 logical channels for data logging (max. up to 8 analog channels)
- Inputs:
- Measuring programmable: 0, 4 or 8
- Binary: 2 or 6
- Modbus RTU Client: 10 devices, 10 registers each
- Outputs:
- Relay: 2, 6 or 8
- Analog 0 / 4...20 mA: 0, 4 or 8
- Supplying output for external devices: 24V d.c. / 30 mA
- Communication interfaces:
- RS-485 MODBUS (Client and Server)
- Ethernet: MODBUS TCP/IP, Webserver (www), FTP
- USB Host 2.0
- Screen: Graphical color display LCD TFT 3.5”
- Internal memory 8 GB for Archiving of measured parameters
- Visualization of measurements in digital form, analog indicators, line charts, bargraphs
- Advanced mathematical functions on measured values
- Archiving and visualization of measuring data transmitted to KD6 from external devices via RS-485 MODBUS
- Settings secured with access password
- PC software for easier setup
- Protection class: IP65 (front)
- Operating temperature: -10...55 °C
- Supply: 85...253 V a.c., 90...300 V d.c. or 20...60 V d.c.
- Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
- Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
- 2000 VAC galvanic isolation
- High accuracy
- EMC compliance - CE symbol
- Mounting on DIN rail - EN-50022 complience
- Supply voltage: 10...30 VDC
- Ambient temperature: -10...+60°C
- Signal splitter DAT5022
- Configurable with switches on body
- 3-way galvanic isolation (2000 VAC)
- Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
- Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
- Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
- Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
- Environment: -20...+70 °C / (non-condensing) 0-90%
- Housing: Self-extinguishing material
- EMC
- Immunity: EN 61000-6-2
- Emission: EN 61000-6-4
- Ethernet 10/100 Base-T Modbus TCP interface (RJ-45 connector)
- Configurable using webserver
- RS-485 (Modbus RTU Master)
- Distance up to 1200 m, up to 32 modules
- LED indication
- Galvanic isolation in all ways (1500 VAC)
- EMC compliance
- Mounting on DIN rail - EN-50022 compliance
- Modbus Slave over RS-485
- Modbus RTU / Modbus ASCII protocols
- Communication parameters configurable by dip-switches
- Watch-dog alarm
- Remotely configurable
- 3-way galvanic isolation (1500 VAC)
- High accuracy
- Mounting on DIN rail - EN-50022 compliance
- Ethernet 10/100 Base-T interface
- Modbus TCP server
- Webserver for configuration of device and representation of actual input values
- Galvanic isolation on all the ways (1500 VAC)
- Remotely configured
- LED indication
- EMC compliance
- DIN rail mounting
Tempmate-S1 data loggers are specially designed for temperature monitoring in any cold chain logistics. The automatically created PDF and CSV report, containing detailed information such as data curve, every single measurement as a table and statistical information.
Без НДС: 24.70 €
They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.
- Single-phase power controller (phase angle load control)
- Control input: DC voltage 0...10 V DC (RSR92-..V..) or current 4...20 mA (RSR92-..I..)
- SCR output (thyristors)
- Load current 25...80 A
- Max. load voltage 280, 530 V AC (single-phase)
- Dielectric strength 4 000 Vrms (opto-isolation)
- MOV protection (built-in varistor)
- Mounting on panel or on heatsinks
- Recognitions, certifications, directives: RoHS, REACH, CE, EAC
- Self-operating signal lamps (optic signaling of AC/DC voltage presence in 1-phase network via lighting of one non-replaceable LED)
- LED colors: green, red, yellow
- Cover - modular, width 17,5 mm
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Applications: in low-voltage systems (130…260 V)
- Compliance with standards: EN 62094-1, EN 61000-4-2, 3, 4, 5, 6, 11
- Recognitions, certifications, directives: RoHS, CE, EAC, UKCA
Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.
- Temperature measurement range*: -200…+100 °C
- Relative humidity measurement range*: 0…100 %
- Ambient light measurement range*: 0…10000 lx
- Local storage capacity*: 24200 values for Temperature, Humidity and Light
- Shelf-Life:
- Lithium Battery devices: 12 months (possibility to charge)
- Non-Lithium Battery devices: 6 months (possibility to charge)
- External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
- Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
- Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
- Recording Duration:
- Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Certifications: CE, EN12830, EMC, RoHS, FCC
- Connectivity: LTE 4G cat 1 with 2G Fallback
- Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
- Location: LBS - GSM Localization
- Recommended Storage Temperature: -15…+25 °C
- Sludge and sand detection
- Oil on water surface detection
- Designed for usage in separators, basins and tanks
- Easy to install, does not need calibration
- Reliable long-term se in harshest conditions
- Acoustic and visual alarms
- 2 switch outputs
- ATEX certified
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- SandSet-1000 is designed for sludge and sand detection in separators, basins and tanks
- Easy to install, does not need calibration
- Reliable long-term se in harshest conditions
- Acoustic and visual alarms
- 2 switch outputs or output to LabkoNet remote monitoring system
- Ultrasonic sensor SET/S, 5 meter cable
- ATEX certified
- Wall-mounted, IP67
- Supply: 230 VAC, 50/60 Hz
- Relay output
- Smoke sensitivity complies with EN 54-7:2000+ A1:2002
- Digital signal processing
- Very low current consumption
- Excellent long-term stability
- LED indication
- Supply: 10...30 VDC
- Warranty: 3 years
- Software to work with Comet devices Sxxxx, Rxxxx, UxxxxM, Dxxxx and Mxxxx
- Device settings
- Data download
- Analysis of critical situations
- Presentation of measured data
- Reports
- Database import/export
- Free license
- Separator alarm system for applications where mains supply is not available
- ATEX certified
- Alarms:
• high level detection
• oil on water surface detection
• sludge under water detection - SolarSet Beacon consists of:
• housing containing and panel
• battery
• charger controller
• flashing beacon for alarm
• sludge and oil level sensor system LevelSet S
- Separator alarm system for applications where mains supply is not available
- ATEX certified
- Alarms:
• high level detection
• oil on water surface detection
• sludge under water detection
- SolarSet Beacon consists of:
• housing containing and panel
• battery
• charger controller
• GSM/GPRS modem
• flashing beacon for alarm
• sludge and oil level sensor system LevelSet S
- Separator alarm system for applications where mains supply is not available
- ATEX certified
- Alarms:
• high level detection
• oil on water surface detection
• sludge under water detection - SolarSet Beacon consists of:
• housing containing and panel
• battery
• charger controller
• GSM/GPRS modem
• sludge and oil level sensor system LevelSet S
For on-line measurements of air pollution or combustion gases flow in chimneys or flues.