- Temperature transmitter 5334A with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5334B for explosive Ex atmosphere with 4...20 mA output, designed for TC, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5335A with 4...20 mA HART protocol output, designed for TC, RTD, mV signal conversion to analog
- To be mounted into B-type electric head
- Temperature transmitter 5350A with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
- Temperature transmitter 5350B for explosive Ex atmosphere with PROFIBUS PA communication, designed for TC, RTD, mV signal conversion
- To be mounted into B-type electric head
Temperature transmitter DAT1010 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm) ir voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1015 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1066 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA). With galvanic isoliation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
- Input (configurable): TC, RTD, mV, resistance and potentiometer
- Output: Modbus RTU / ASCII Slave device over RS-485
- 1500 Vac 3-ways Galvanic Isolation
- High accuracy
- Remotely configurable over RS-485
- EMC compliance (CE mark)
- Mounting in B-type head
- Easy implementation in existing PLCs and SCADA systems
- Operating temperature: -40...+85°C
- Supply voltage: 18...30 VDC
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.
Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
- Measures ambient temperature, humidity, pressure
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measuring ranges: -30...+80 °C, 0...100 %RH, 600...1100 hPa
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Calibration certificate included
- Protection class: IP30
Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.
Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.
- Flow and temperature sensor for liquids in pipes
- Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
- Flow measurement range: 1...150 cm/s (water)
- Temperature measurement switching points: 15, 30, 45, 60, 75 °C
- Flow rate measurement is shown in a bar graph by five green LEDs
- Settings provided by magnetic pen
- Stainless steel case
- Supply: 12...34 VDC
- Ambient temperature: -20...+80 °C
- Protection class: IP67 / IP68
- Air velocity, airflow and temperature measurement
- Air flow measurement with a cone
- Automatic average
- Display of minimum and maximum values, hold function
- Adjustable auto shut-off
- Detection of flow direction
- Selection of units
- Supplied with calibration certificate
- Display of minimum and maximum values, hold function
- Adjustable auto shut-off
- Automatic average
- Selection of units
- Detection of flow direction (LV 110/LV 117)
- Supplied with calibration certificate
- Air flow measurement with a cone (LV 110/LV 117)
The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.
- Temperature measuring range: 0… +1800 °C
- Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
- Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
- Gastight process connection: (to 0.1 MPa / 1 bar)
- Optionally the head can be installed with a local temperature display (DANWdie-LED)
- ATEX and EAC Ex versions
- For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444
Capillary thermometer TXC is designed for temperature measurement from -200 to +800 °C. Capillary parameters, diameter and length of measuring element, measurement dial range, process connection, contact type and other parameters must be chosen from the catalogue.
Stainless steel thermometer TXR is designed for temperature measurement from -200 to +800 °C. Diameter and length of measuring element, measurement dial range, process connection, contact type and other parameters must be chosen from the catalogue.
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Versions according to PN-79/M-53857/05
- Threads for thermometer: metric M12x1.5, M14x1.5
- Lengths: according to customer's specification
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Bore diameters: Ø3.5 mm, Ø7 mm
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Optional designs per DIN 43772 ( form 4 )
- Other materials, threads and dimensions
- Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT or other
- Immersion lengths: from 50 mm to 2500 mm (according to customer's specification)
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti )
- Dimension tolerance according to DIN ISO 2768
- Protection tube coated by layer of CrC to increase abrasion resistance
- Protection tube coated by teflon® PTFE to increase corrosion resistance
- Other materials, threads, flanges and dimensions
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Designed to measure the thickness of non-magnetic layers
- Can be used for construction, ships, tanks, piping, boilers, vehicles protective layer quality control
- High accuracy in wide temperature (with compensation) range using the same probe
- Fit for work outside
- Certificate of calibration included
They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.
- Three-phase power controller (phase angle load control)
- Control input: DC voltage 0...10 V DC or current 4...20 mA
- SCR output (thyristors)
- Load current 25...80 A
- Max. load voltage 530 V AC (three-phase)
- Dielectric strength 4 000 Vrms (opto-isolation)
- MOV protection (built-in varistor)
- Mounting on heatsinks
- Recognitions, certifications, directives: RoHS, REACH, CE, EAC
- Self-operating signal lamps (optic signaling of AC/DC voltage presence in 3-phase network – 3(N) 400 / 230 V via lighting of one non-replaceable LED)
- LED colors: green, red, (red, yellow, green)
- Cover - modular, width 17,5 mm
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Applications: in low-voltage systems (400 / 230 V)
- Compliance with standards: EN 62094-1, EN 61000-4-2, 3, 4, 5, 6, 11
- Recognitions, certifications, directives: RoHS, CE, EAC, UKCA
- Wood moisture transmitter KP (0...20 mA), made by Tanel (Poland)
- Output signal 0...20 mA which corresponds to range 0...60 %; practically used range is 8...60 %
- Display: LCD 8 digits, 7 mm; LED 6 digits, 7 mm.
- Calculation frequency: Min. 30 Hz / 20 Hz (type 3), max. 7,5 kHz
Totalizing counter Type 634 – “MINI I”.
- Display 6 or 7 digit, 4mm
- Protection class IP65
- Transducer for DC current and voltage into other DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- Solves grounding problem in meshed signal networks
- User selectable type and range of input
Trigger light barriers are mainly used in the field of metal stamping. The TLB series comprises light barriers with infrared light beam (IR) or visible light beam (VIS), in split shape as well as in fork shape (with or without compressed air supply). Characteristic for all light barriers of TLB Series is the external electronics: Pulsating light or constant light amplifier with digital output or analog output (voltage output and current output).
- Input: infrared sensor (850 nm)
- Output: 4...20 mA current loop with HART interface, 2x PNP or NPN
- Measurement range: 0...10 kNTU
- Measurement rate: 10 measurements per second
- Display, LED indication
- Operating temperature: -40...+75 °C
- Protection class: IP65
- Supply: 24...30 VDC
- Simultaneous detection of two gases (please ask for available gas combinations and possible limitations)
- Switch output: 4 x SPDT (2 for each sensor)
- Alarms: LED indicators and buzzers (85 dB)
- Supply: 24 VDC/VAC / 90...265 VAC
- Protection class: IP65
Traditional U-shaped with easily controlled zero point. For air and non-aggressive gasses.
- Range: -500...500 Pa
- For continuous non-contact water level measurement in outdoor applications - rivers, canals, sumps, liquid and slurry, pastes and bulk materials
- Remote installation and communication via HART® protocol
- Output: 4…20 mA, HART®
- Variable installation thanks to the possibility of connection via lower or upper thread
- Intelligent numerical signal processing with the elimination of false reflections
- Protection class: IP68
- With the help of a directional funnel it is possible to increase the reception of the reflected echo and to measure problematic media (foaming levels, loose materials, etc.)
- Operating temperature: -30…+60…+70 °C
- Up to 10 / 15 m level measurement with automatic temperature compensation
- Calculation of filling in the tank or flow in open channels
- Galvanically isolated 0/4...20 mA analog output
- Digital RS-485 Modbus RTU interface
- 2 alarm outputs
- Internal data and setup memory
- Two 32-points individual characteristics (for recalculation)
- LCD screen
- Housing protection grade: IP66
- Sensor protection grade: IP66 / IP 68
- Supply: 12...25...40 VDC
- Operating temperature: -20...23...55 °C
- Ultrasonic level sensor ULS-53 is designed for non-contact level sensing of various liquid and bulk-solid materials in closed or open tank, vessels, sumps, reservoirs etc.
- Adjustment are made by two buttons or by magnetic pen
- State indication by two LEDs
- Output:
- PNP transistor with an open collector (max. switch current 300 mA)
- Two-state current switch 4…20 mA
- Xi version for usage in explosive areas
- Up to 10 / 15 m level measurement
- Analog output: 4…20 mA
- Digital output: RS-485 Modbus RTU
- Resolution: 3 mm
- Supply: 24 VDC / 300 mA
- Operating temperature: -20...60 °C
- Cable length: 1 m
The RE4X series controllers have a wide range of process control options and versions. Programmable inputs for standard signals, signal difference measurement between channels, control algorithms ON / OFF, PID, soft start and Fuzzy logic. Remote control with SCADA system through RS-485. The required output types can be selected during ordering (relays, SSR, analog).
Main features:
- Sampling rate (5 times / second)
- 1 input: TC and RTD sensors; standard signals 0 / 4…20 mA and 0…10 V
- 2 input: 0 / 4…20 mA and 0…10 V
- Binary input for changing the function of the controller and SP switching
- Outputs: relays - NO, SSR; analog - 0 / 4…20 mA and 0…10 V
- Galvanically isolated transducer and sensors power supply 24 V d.c. 25 mA
- Programmable digital filter
- Hardware and software security before changing settings
- Alarm for breaking the control loop
- Supply: 90…264 V a.c. or 11…26 V a.c. / d.c.
- Protection class: IP65
The RE12S Universal PID Controller is an advanced and versatile device designed for precise process control in various industrial applications. With adaptive, auto, and self-tuning PID as well as ON-OFF control capabilities, the RE12S ensures optimal performance in maintaining desired setpoints. It features a dual LED display, capacitive touch keypad, and supports up to 128-step profiling for complex control requirements. The unit's robust communication options, including RS485 MODBUS RTU, allow seamless integration into existing systems, enhancing both functionality and connectivity.
- Control algorithm: Adaptive, Auto, Self-tune PID, ON-OFF
- Input: Thermocouple (J, K, T, R, S, C, E, B, N, L, U, W, Platinel II), RTD (PT100), - 5…56mV, 0…10V, 0…20mA
- Alarm Outputs 3x: Multiple settings including deviation high/low, absolute high/low, band, sensor break
- Profile Controller: Up to 128 steps
- Special Modes: Heat-Cool PID, Auto/Manual, Single point ramp/soak, Soft start
- Communication: RS485 MODBUS RTU
- Power Supply: 90...270 VAC / DC (50/60Hz)
- Display: 4+4 digit, 7 segments
- Ambient temperature / humidity: 0…+50 °C / < 85%RH
- Dimensions: 52 x 52 x 76 mm