  • Thermostat ranges 0-40°C or 0-90°C
  • Digital thermostat
  • Standard variants for 25, 50, 105 and 200 liter capacity barrels
  • Blanket is made from polyester/teflon
  • Sewn heating insulation
  • Damage-resistant spring heating element
  • Regulated, easily removed buckles
  • 3 m supply cable
  • Protection class IP40
  • Can be used with electrical heating pad for barrels

These jacket heaters enable the comfortable and effective way to heat up IBC containers and other tanks. Low energy losses, even heat distribution. Can be used for various products: water, oils, diesel fuel, resin, Vaseline, wax, lanolin, fats, butters, Ghee, glue and adhesive. Can be used with insulation lid.

  • 1, 2, or 3 thermostats adjustable from 0…+90 °C
  • Teflon coated Polyester Material
  • Standard size IBC 1000L (4400 x 1000 mm)
  • Durable, lightweight design with quick release buckles
  • 3 m connection cable
  • Protection class IP40 (Optional IP54)
  • Warm-up duration approx. 48h (1000L drum with water starting from +15º C to +50º C with 2x1000 W heaters and isolation lid)
  • Warm-up duration approx. 48h (1000L drum with water starting from +15º C to +70º C with 3x1000 W heaters and isolation lid)

Fluid level electrode probes SKC-101, designed to control conductive fluid level in high temperature and high pressure medium. Modifications differ by permissible operating temperature. Recommended to use with Elcluwo 112...114 level alarms.

  • Electrode level sensor AUREGIS LJ-B for level measurement
  • Process temperature: From -30 to 180°C 
  • Electrode level sensor AUREGIS LJ-DSH-2R, LJ-DSH-3R for level measurement
  • LJ-DSH-2R - 2 electrode level sensor; LJ-DSH-3R - 3 electrode level sensor
  • Process temperature: -20...+80 °C

Electrode level sensor AUREGIS LJ-E3 with 3 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.

Electrode level sensor AUREGIS LJ-E5 with 5 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.

  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
  • Double water- and air-resistant sealant increases protection against infiltration even more
  • Weight: 1050 g; Buoy volume: 990 cm3; Maximum pressure: < 2 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached.
  • Weight: 163 g; Buoy volume: 280 cm3: Maximum pressure:< 1 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
  • Double water- and air-resistant sealant increases protection against infiltration even more
  • Weight: 250 g; Buoy volume: 430 cm3; Maximum pressure: < 1 bar
  • Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
  • Boasts for great reliability and small size
  • Weight: 111 g; Buoy volume: 225 cm3; Maximum pressure: < 2 bar / < 5 bar
  • Temperature range: -50...250 °C or -50...500 °C
  • Accuracy: ±0,03 °C
  • Resolution: 0,01 °C (switchable to 0,1 °C)
  • Display: LCD, 6 digits, backlight
  • MIN, MAX, hold functions
  • Sensor: Pt100
  • Protection class: IP65
  • Suitcase is ordered separately
  • Thermometer DT20 for temperature measurement in smokehouses, butcheries, etc.
  • Measuring range -50...20 °C, accuracy 0,1 °C
  • Sharp-tipped probe ST-03 (4x120 mm) made of stainless, acid-resistant steel (1H18N9T)
  • Cable length 3 m
  • Operating temperature 0...40 °C
  • Supply 230 V
  • Size 130x94x81 mm
  • Ergonomic ABS casing with indicator, IP65

Digital thermometer DT-34 is designed for fluid, gas and solid body temperature measurement in range of -50°C to 270°C. Casing is made out of mechanically resistant plastic (ABS) and contains special collars for dust, dirt and water protection.

The measurements are done with a Pt1000 sensor. Special sensor construction and small size ensure little thermal inertia and fast measurement. The results are shown in a 4-digit LCD display, of which the fourth digit shows the decimal part. Negative temperatures are shown with a minus sign. The device can be used in laboratories and manufacturing for technological measurements in various conditions.

Thermometer DT-34 can be shipped with a fitting temperature sensor made according to Your requirements.

Digital thermometer ST-90 for temperature measurement from -200 to 1200 °C.

ST-90 is designed for usage with various construction K-type thermocouple sensors. The sensor is connected via MiniTherm port on the top of ST-90. The device is supplied by 9V 6F22 battery (work time up to 500 h). Indication on LCD screen (3 1/2). Special collars protect the electronics from moisture, grease and dust.

Thermometer ST-90 can be shipped with a fitting temperature sensor made according to Your requirements.

  • Temperature range: -30...+70 °C
  • Humidity range: 0...100% RH
  • Resolution in range: 0.1 °C
  • Temperature accuracy: In range -20...+40 °C: ±0,5 °C; outside of range: ±1,0 °C
  • Humidity accuracy: ± 2 %RH
  • Supply: 3.6 V (Lithium battery)
  • Battery lifetime: up to 2 years
  • Protection class: IP65
  • Size: 45 x 100 x 19 mm

Digital thermometer DT-1 is designed to be used for temperature measurements in liquids, gasses and solids in range of -50...+200 °C. The casing is made out of mechanically resistant plastic (ABS) and has special collars, protecting the device from dust, dirt and water. The measurements are conducted using a Pt1000 sensor. Special sensor construction and small size guarantee little delay and fast measurement. The results are shown in 4-digit LCD (last digit represents the decimal part). The device can be used in laboratories and industry in any conditions.