  • Flow monitoring with SIL1 certification according to IEC 62061 (corresponds to Performance Level c according to EN ISO 13849-1)
  • Can be used in ATEX zones 1 and 2 in conjunction with 2 Zener barriers supplied
  • Large measuring range from 0.1 to 30 m/s with media temperatures from 0°C to 60°C
  • With switching output suitable for control cabinet installation
  • Developed for demanding industrial applications, IP40
  • Example areas of application: Flow monitoring in paint shops, paper factories and research facilities
  • Air flow monitor for monitoring air flow in ATEX zones 1 and 2 (optionally additionally with SIL1 or SIL2 certification)
  • With switching output (1 NO/ 1 NC) for control cabinet installation
  • Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
  • Large measuring range (0.1...30 m / s), simple and fast commissioning
  • Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC, industrial furnaces, granulate dryers
  • Exd fire-resistant RTD temperature sensors are designed for temperature sensing in explosive atmospheres
  • Ranges: -200...+150°C; -200...+550°C; -200...+600°C
  • Outputs: RTD, 4..20 mA
  • Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
  • Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
  • Outputs: TC, 4...20 mA
Exi RTD sensors for explosive atmospheres with connection head. Technical specifications Example Model Range Diameter Output XI-TOPGB / XI-APTOPGB -200 .. +150°C Ø9, Ø10, Ø11, Ø12, Ø15 mm RTD, 4..20 mA XI-TOPG / XI-APTOPG -200 .. +550°C Ø11, Ø12, Ø14, Ø15 mm RTD, 4..20 mA XI-TOPT / XI-APTOPT -200 ...
  • Exi RTD sensors for explosive atmospheres with cable
  • Range: -50 .. +400°C
  • Cable insulation: PVC, silicone, teflon, glass fiber
Exi RTD sensors for explosive atmospheres with mineral insulation. Technical specifications Example Model Range Diameter XI-TOPI / XI-APTOPI -200 .. +600°C Ø3, Ø4.5, Ø6, Ø8 mm XI-TRP-BTW -50 .. +600°C Ø1.5, Ø2, Ø3 mm XI-TRP-WL -50 .. +600°C Ø1.5, Ø2, Ø3, Ø4.5, Ø6 mm XI-TRP-TKbW ..

Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.

  • Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
  • Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
  • CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
  • Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
  • Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
  • Air quality (VOC) measuring range: 0…100 %
  • Data output:  galvanically separated RS-485 Modbus RTU interface
  • Variants: with / without LCD display
  • One sensor covers about 30 m² of room area
  • Power supply: 24 V ac/dc (200 mA)
  • Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
  • Suitable for ATEX Zones 2 and 22
  • Electrochemical gas sensor
  • Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life pellistor (catalytic bead) sensor
  • Range: 0...15% vol. (0…100% LEL)
  • Resolution: 0.1% vol. or 1% LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -10...+50 °C
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
  • Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...300 or 0...1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detected gases: hydrogen, methane, acetylene, propane, butane
  • Default calibration: methane CH4
  • Stable long-life metal-oxide / pellistor sensor
  • Range: 0...100% LEL
  • Resolution: 0,1 / 1 % LEL
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...10 / 0...200 / 0...1500 ppm
  • Resolution: 0,1 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
  • Stable long-life metal-oxide sensor
  • Range: 0…1000 / 0…2500 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...100 ppm, 0...2000 ppm H2S
  • Resolution: 1 ppm H2S
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide / pellistor sensor
  • Range: 0...100% LEL CH4
  • Resolution: 0,1 / 1 % LEL CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0…250 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life optical NDIR sensor
  • Range: 0…1000 ppm
  • Resolution: 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical sensor
  • Range: 0...25 % vol O2
  • Resolution: 0,01 % vol O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector (PID) sensor
  • Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
  • Default calibration: Isobutylene
  • Range: 0…40 / 0…200 ppm isobutylene
  • Resolution: 0,01 / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Detectable gases: acetone, ethanol, toluene, xylene etc.
  • Default calibration: toluene
  • Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
  • Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST)
  • Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
  • Supply: 12...36 VDC (default), 24 VAC or 230 VAC

Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.

  • Material of float: stainless steel AISI 316 SS
  • Max. temperature: -30...+105 °C
  • Switch rating: 50 VA
  • Switching voltage: 230 AC / DC

Thermal mass flow sensor for compressed air and gases VA 500

  • 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
  • Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
  • Optional: Bi-directional measurement
  • Pressure tight up to 50 bar
  • Temperature range up to 110 °C
  • Protection class IP65
  • Suitable for gas velocities up to 224 Nm/s
  • Integrated display for showing the measured values
  • Can be used from 1/2" up to 40", larger diameters on request
  • Easy installation under pressure
  • Settings can be changed via the display
  • Main counter reading can be reset via the display
  • Flow monitor for liquid media in the range of 4…400 cm/s with analog (4…20 mA) and status output (PNP, NPN) for monitoring a flow threshold
  • Ten LEDs indicate flow and contact closure
  • Equipped with 2 control buttons for setting the switching point
  • Available with 65 mm and 125 mm mounting depths
  • Rugged design for industrial environments, IP67
  • Calorimetric measuring principle
  • Units freely selectable via keys at the display
  • Display shows 2 values at the same time, twistable by 180 ° degree
  • Integrated Modbus interface enables connection control systems, SCADA
  • M-Bus (optional)
  • Analog output 4...20 mA
  • Pulse output (galvanic isolation)
  • High measuring accuracy (ideal for leakage measurement)
  • Flow sensor suitable for evaluation unit NLSW®45-6 and NLSW®45-6.1
  • Thread: PG7, optional accessories available
  • Material: stainless steel V4A
  • Media temperature: optional up to 400°C
  • Protection class sensor: IP50
  • Insertion depth: 50 mm, 130 mm, 165 mm, 300 mm
  • Compressive strength: 10 bar
  • Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
  • Detectable gases: O2, CO, CO2, NO, NOx
  • Up to three gas sensors
  • CO measurement up to 8000 ppm
  • Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
  • Color display screen with buttons
  • Communication: Bluetooth (mobile App), remote printer
  • Measurement storage: smartphone
  • Predictive maintenance with estimated sensor life and calibration reminders
  • Protection class: IP42
  • Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
  • Operating temperature: -5…+45 °C
  • Sensor protection by pump stopping
Fluid level electrode 11 SN1 for fluid level measurement.  Ambient temperature ≤ 60°C Electrode material Stainless steel (AISI 303) Casing material Plastic (PPOX) Connection PG7 collar (for cable from 2,5 to 6 mm2 ) More on electrode 11 SN1 on Lovato website [EN]11 SN1 datasheet [EN] ..
Fluid level electrode 31 CGL125 3 for fluid level measurement.  Ambient temperature ≤ 180°C Electrode length 300 mm Electrode material Stainless steel (AISI 303) Operating pressure ≤ 10bar Insulator Teflon Process connection G 3/8'' More on electrode 31 CGL125 3 on Lovato website [EN]31 CGL125 3 datasheet [EN] ..
Fluid level electrode 31 PS31 for fluid level measurement. Technical specifications Ambient temperature ≤ 70 °C Electrode length 300 mm Electrode material Stainless steel (AISI 303) Operating pressure ≤ 2 bar Insulator Teflon Process connection G 1/2''  More on electrode 31 PS31 on Lovato website [EN]31 PS31 datasheet [EN] ..
Fluid level electrode 31 SCM 04 for fluid level measurement. Electrode extension is available, M4 thread. Technical specifications Ambient temperature ≤ 100 °C Operating pressure ≤ 10 bar Electrode length 40 mm Electrode material Stainless steel (AISI 303) Casing material Plastic (PPOX) Insulator Ceramics Connection PG7 co..

The FPI 8237 IO-Link Flush Membrane pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel 1.4462. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: -0,5...0,5 to 0...100 bar
  • Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN / Push-Pull configurable
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Measuring principle: Thin-film-on-steel
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Protection class: IP65, IP67
  • Applications: Hydraulics, Machine tools, Process technology, Food industry, Water treatment

The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.

  • Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
  • Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
  • Accuracy at 25°C typically: ± 0.5 % FS typ.
  • Membrane in Duplex steel 1.4462
  • Pressure connection: G1/2” male, flush membrane
  • Media temperature –10... +125 °C
  • Ambient temperature: –10...+125 °C
  • Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics

The frame light barriers of FLB Series are used for the measurement of smallest unguided parts.

  • Fuel sawdust moisture meter WTR-2A is designed to measure moisture of sawdust, scobs, wood shavings, slivers and other finely crumbled wood waste used as fuel
  • Range: 35...85 %
  • Sample volume: 120 cm2
  • Measuring sample: 0,2 MPa
  • Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
  • Flexible control: 3 relays (SPDT, potential-free, 250 V)
  • Intelligent Communication: RS-485 interface with DGC and Modbus protocol
  • Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
  • Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
  • Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
  • Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
  • Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay

SKU: 5905309602212

  • Efento Gateway automatically transfers gathered data from Efento BLE (Bluetooth Low Energy) sensors to Efento Cloud or any other IoT platform over 4G LTE
  • Gateway stores 500,000 measurements in its buffer memory in case the connection to Efento Cloud is lost, it will send the measurements right after connection is restored
  • If Gateway used without Efento cloud it can store sensors data in its memory
  • In local mode you can check the current and historical measurements (table/chart) and export the data in a form of CSV report
  • Gateway communicates with sensors wirelessly over BLE. The maximum distance between Gateway and sensor is 100 m in the open space and 20 – 30 m in the buildings
  • One gateway supports up to 128 Efento sensors
  • Gateway can be integrated with any cloud platform or software that supports HTTP protocol (REST API)
  • Setup takes under 5 minutes and can be completed using a smartphone with a free mobile app
  • SIM card slot for LTE Cat 1 connection
  • Power supply: 5 V, 1 A (USB-C)
  • Backup battery: LI-Po, 1900 mAh (up to 12 hours backup power)
  • Operating temperature: 0…+40 °C

SKU: 5906660327066

  • Efento Gateway automatically transfers gathered data from Efento BLE (Bluetooth Low Energy) sensors to Efento Cloud or any other IoT platform
  • Gateway stores 500,000 measurements in its buffer memory in case the connection to Efento Cloud is lost, it will send the measurements right after connection is restored
  • If Gateway used without Efento cloud it can store sensors data in its memory
  • In local mode you can check the current and historical measurements (table/chart) and export the data in a form of CSV report
  • Gateway communicates with sensors wirelessly over BLE. The maximum distance between Gateway and sensor is 100 m in the open space and 20 – 30 m in the buildings
  • One gateway supports up to 128 Efento sensors
  • Gateway can be integrated with any cloud platform or software that supports HTTP protocol (REST API)
  • Configuration of Efento Gateway using any internet browser over LAN
  • Ethernet connection for data transfer
  • Power supply: 5 V, 1 A (mini USB)
  • Operating temperature: 0…+40 °C

Inline sensors of the GLAST series primarily are used for the inspection of highly reflecting surfaces (e.g. stainless steel panels, aluminum sheets, painted surfaces, plastic films) and transparent objects (films, glass plates, plexiglass plates).

GLOSS sensors prioritize narrower detection range, thus making it faster than similar devices.

Gloss sensors RLS-GD-15, R-LAS-GD-15-HP. The sensors are designed for plastic plate and ceramic parts gloss degree measurement. Two measurements are done at the same time – direct reflection direction and diffusion reflection direction.

  • Portable, small dimension grain moisture meter
  • The sample is ground, increasing the measurement accuracy
  • External probes can be connected
  • Temperature measurement accuracy: ±0,5 °C
  • Moisture measurement accuracy: ±0,5 %
  • Automatic temperature compensation
  • Calibrated for more than 400 grain species
  • 2” LCD screen
  • USB connection for software updates and data transfer
  • Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
  • Portable, small dimension grain moisture meter
  • Temperature measurement accuracy: ±0,5 °C
  • Moisture measurement accuracy: ±1 % (in range up to 10 %)
  • Calibrated for more than a hundred grain types (the list can be extended)
  • Automatic temperature compensation
  • 2” LCD screen
  • USB connection for software updates
  • Supply: 2xAA (1,5 V, LR6)
  • Portable, small dimension grain moisture meter
  • The sample is ground, increasing the measurement accuracy
  • Temperature measurement accuracy: ±0,5 °C
  • Moisture measurement accuracy: ±0,5 %
  • Calibrated for more than 400 grain types
  • Automatic temperature compensation
  • 2” LCD screen
  • USB connection for software updates
  • Supply: 1x6LF-22 (9 V)
Hay and straw moisture and temperature meter DRAMINSKI HMM works by measuring electrical conductivity variation. HMM measures hay/straw moisture and indicates it on the LCD screen. Measured value is shown in percentage. Device can measure temperature. Has internal memory which stores last 50 measurements. Shows maximal, minimal and average values.  Technical parameters Measuring range:       Moisture       Temperature 10...80% 1…100°C ..
Loading...