- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- Pressure measurement range: 600...1100 hPa
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- GSM modem (GPRS)
- SMS and JSON messages can be sent via GPRS data connection
- Messages can be sent on alarms and periodically
- Data can be transferred to PC via USB-C interface
- Calibration certificate of manufacturer included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Universal air and environment quality sensor E2-CO2-series measures CO2 (carbon dioxide) level, temperature, humidity, pressure, sound level, ambient light (LUX). Transmits instant values, average hourly values, and average 24-hour values
- Communication: wM-BUS EN13757-3/4:2013, complies OMS 4.0.2
- Modes: C1-A/B, T1 or S1 (selectable on order)
- Measurement ranges
- Temperature: -40…85 °C
- Humidity: 0…100 % RH (non-condensing)
- CO2: 0…5000 ppm (0…55 °C)
- LUX: 0,01…83000 LUX at same frequency as the human eye
- Absolute pressure: 20…100 kPa
- Sound level: 53…90 dBa at 850 Hz
- Measurement accuracy
- Temperature: ± 0,2 at +5…+60 °C; ± 0,5 at -20…+85 °C
- Humidity: ± 2 % RH at 20…80 % RH; ± 3 % RH at 10…90 % RH; ± 3,5 % RH at 0…100 % RH
- CO2: ± (50 ppm + 3%)
- LUX: 4 %
- Pressure: 0,4 kPa
- CO2 sensor calibrates every 20 days
- Warnings about low battery, CO2 sensor malfunction, calibration not performed yet
- Transmission interval: every 90 seconds
- Measured values sample interval: every 6 minutes
- LED and sound indication about CO2 exceeded limit
- Device has 2 antennas for maximum range in both vertical and horizontal directions
- Power supply: 2 x ER18505 3.6 V Li-SOCI2 battery pack (8200 mAh)
- Up to 14 years battery lifetime, standard configuration and operating temperature
- Датчик температуры AUREGIS ТJ-1 с соединительным кабелем
- Предназначен для измерения температуры в диапазоне -50°C до 400°C
- Возможны исполнения по требованиям заказчика
- Тип сенсора: PT100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
- Датчик температуры AUREGIS ТJ-4 с соединительным кабелем. Предназначен для измерения температуры в диапазоне -50°C до 400°C
- Возможны исполнения по требованиям заказчика
- Тип сенсора: PT100, PT1000, K, J, Ni120, Ni1000
- Sensor type: RTD (Pt100, Pt1000), TC (K, J)
- Output: RTD (Pt100, Pt1000), TC (K, J), 4...20 mA, 4...20 mA +HART, 0...10 V, RS-485, IO-LINK
- Measuring range: -30 °C ... 250 °C, 550 °C
- Accuracy: Class A or B /cl.2
- Sensor tube:
- Material: Stainless steel AISI304 (1.4301)
- Diameter: Ø6/8/10mm
- Length: 100, 200, 500, 700, 1000mm or on request
- Connection head type: B
- Protection class: IP65
- Electrical connection: 2-wire, 3-wire or on request
- Process connection: G¼”; M20x1,5; G½” or on request
- Various sizes are available depending on customer requirements and drawings
- The temperature sensor TJ-M is designed for measuring the temperature in the capacity ranging from -30°C to 550°C
- The design could be changed according the requirements and drawings of the customer
- Sensor type: Pt100, Pt1000, K, J
- Connection head type: M
- Protection class: IP65
- Связь сети RS-485 с компьютером через USB порт.
- Максимальная скорость связи 1 Mb /s (зависит от длины линии RS-485).
- Гальваническое разделение портов входа и выхода.
- Преобразователь типа P20H предназначен для преобразования сигнала высокого напряжения или тока с однополярных или двуролярных в стандартные сигналы постоянного тока и напряжения или в цыфровой формат МODBUS.
- Вход гальванически отделен от выхода и источника питания.
- Программирование прибора выполняется с помощью программатора PD14 и бесплатной программой LPConfig, с помощью которой можно конфигурировать, контролировать сигналы, изменять настройки преобразователя.
Пассивный сепаратор сигналов, стандартного 0/4…20мA тока, питаемый от токовой петли.
- Устройство предназначено для преобразования сопротивления, стандартного напряжения и тока термодатчика на сигналы постоянного напряжения и тока
- Ввод гальванически изолирован от выхода и питания
- С помощью программатором PD14 можно запрограммировать тип выхода, период усреднения, настроить индивидуальную характеристику выхода и измеряемый сигнал
- Прибор предназначен для преобразования и галванического разделения стандартных сигналов постоянного тока и напряжения и установления индивидуальной характерисики выходного сигнала.
- Вход гальванически изолирован от выхода и источника питания.
- Программирование прибора выполняется с помощью программатора PD14 и бесплатной программой LPConfig.
- Measurement range: -40...+150 °C
- Temperature measurement accuracy: ± 1,3 °C
- Operating temperature: -20...+50 °C
- Used with wireless manifold
- Cable of 2 m length
- 124 refrigerant gases
TSV202-60 ideal for monitoring battery banks, solar panels, industrial control circuits, and other high-voltage applications.
- Dual channel input: 0…60 V
- Communication interface: 1-Wire protocol
- Accuracy: ±1%
- Resolution: 0.001V
- Galvanic isolation between the voltage circuit and 1-Wire bus
- Operating environment: -20…+60 °C / 10…90 %RH
- Warranty: 3 years
- 1-Wire protocol ambient light sensor
- Light measurement range: 0...83000 lux
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
- Dual channel input: 0…24 mA or 0…10 V
- Communication interface: 1-Wire protocol
- Accuracy: ±1 %
- Resolution: 0.001mA / 0.001 V
- Galvanic isolation between the current circuit and 1-Wire bus
- Detection of special states such as sensor errors or calibration values
- Operating environment: -20…+60 °C / 10…90 %RH
- Warranty: 3 years
- 1-Wire protocol ambient pressure sensor TSP200
- Pressure measurement range: 300...1100 hPa
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
TSM400-1-CP is a multi-parameters sensor that supports the 1-Wire protocol. The sensor measures the concentration of carbon dioxide and atmospheric pressure.
- CO2 measurements range: 400…5000 ppm
- Accuracy: ± (40 ppm + 5 %)
- Resolution: 1 ppm
- Calibration: manual
- Pressure measurements range: 10…1200 hPa
- Accuracy (min): ±1.5 (25°C, 750 hPa)
- Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
- Resolution: 1 hPa
- Operating temperature range: -20…+60°C
- Operating relative humidity range: 5…95% (non-condensing)
- Ingress protection: IP20
- Operating voltage range: 4,5…26 VDC
- 1-Wire protocol current transmitter
- Current measurement range: 0,3...15 A (AC / DC, set by jumper)
- Resolution: 10 bits
- Galvanic isolation between the current circuit and 1-Wire bus
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
TSC201 is a compact current sensor with a 1-Wire interface and an input range up to 10 A, designed for AC and DC current monitoring. Its range allows direct measurement of low currents or connection to current transformers (CTs) with 10 A secondary output for accurate indirect monitoring of higher currents.
- 1-Wire protocol current transmitter
- Current measurement range: 0,1...10 A (AC / DC)
- Measuring accuracy: ± 1 %
- Resolution: 0,01 A
- Galvanic isolation between the current circuit and 1-Wire bus
- Power supply: 4,0…5,5 V
- Excellent long-term stability
- Warranty: 3 years
- Input: Pt100 (2-, 3-, 4-wire)
- Measurement range: -200...+850 °C
- Resolution: 24 bits
- Very low current consumption
- No external power supply needed
- Warranty: 3 years
- Connection: RJ-11
TSM400-1-TH is a digital temperature and humidity sensor with a 1-Wire interface. Suitable for monitoring air quality of server rooms, data centers, offices and stores.
- Temperature measurement range: -20…+60°C
- Accuracy (min): ± 0,4 °C (in -10…+60°C range)
- Accuracy (max): ± 0,6 °C (in -20…+60°C range)
- Resolution: 0,1 °C
- Relative humidity measurement range: 10 to 90% (non-condensing)
- Accuracy (min): ± 3.0 % RH (in 20…80 % RH range)
- Accuracy (max): ± 5.0 % RH (in 10…90 % RH range)
- Resolution: 0,1 %RH
- Excellent long-term stability
- The unique 64-Bit serial number for multi-sensors support
- Ingress protection: IP20
- Operating voltage range: 4,5…26 VDC
SPECTRO-2 has 2 contrast sensors, allowing it to calculate other parameters.
- Input: 2x thermocouples - J, K, T, N, E, B, R, and S
- Output: Modbus RTU – RS-485
- Resolution: 24 bits with DSP processing
- Working isolation voltage: 1500 Vrms
- Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
- DIN rail mounting
- Power supply: 5…30 Vdc
- Warranty: 3 years
- Sturdy
- Hanging hook
- 3 'Y' ¼” 'MFL connectors including one with a Schrader valve
- Digital inputs: 2
- 1-Wire input (up to 8 sensors)
- RS-485 input (up to 8 sensors)
- Analog inputs: 4 (2 x 0...10 VDC, 2 x 0...10 VDC / 4...20 mA, WEB control)
- Relay outputs: 4 (NO/NC)
- Setup via USB or SMS
- Data logger for up to 52 000 records
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- Communication: 4G-LTE, 3G-WCDMA
- SMS alarms (up to 5 numbers)
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- 4G LTE supported frequency bands:
- B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28/ B66/B34/B38/B39/B40/B41
- 3G supported frequency bands:
- B1/B2/B4/B5/B6/B8/B19
- 2G supported frequency bands:
- B2/B3/B5/B8
- M2M communication protocols: MQTT, HTTP API (XML or JSON)
- Setup via WEB interface through the USB or remote setup with HTTP API or SMS commands
- Digital inputs: 2 “dry contacts”
- 1-Wire input (up to 4 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- E-mail alarms (up to 5 recipients), SMTP with TLS support
- SMS alarms (up to 5 recipients)
- GSM Geolocation (optional)
- Firmware update over the air (FOTA)
- Operating temperature: -20...+55 °C
- Supply: 10…28 VDC
TCG210-4 is a battery-powered 4G parcel temperature and humidity logger with fallback support for 2G communication. The device is compatible with HTTP/HTTPS API protocols, making it suitable for modern IoT applications. It periodically sends HTTP/HTTPS POST requests to a remote server, containing a status file in JSON format and the most recent logged data in CSV format.
- Global connectivity - Quad-band 4G LTE Cat.1 with 2G fallback ensures reliable operation worldwide.
- Battery-powered autonomy - Operates for months without external power, ideal for parcel monitoring and remote applications.
- Intelligent power management - Advanced sleep mode significantly extends battery life.
- Flexible configuration - Easy setup via Wi-Fi, SMS, or HTTP API.
- Real-time alerts - Instant SMS alarm notifications to up to five phone numbers.
- Integrated sensing - High-accuracy temperature and humidity sensor for critical parcel monitoring.
- Large data storage - Onboard memory for up to 70,000 logged records.
- Seamless IoT integration - Periodic HTTP/HTTPS POST with current status in JSON format.
- Data export - Automatic upload of logged data in CSV format to a remote server.
- Remote management - Full device control through HTTP API commands.
- Future-proof - Firmware update over Wi-Fi or 4G LTE keeps the device always up to date.
- Compact and lightweight - Designed for easy deployment in parcel logistics, cold chain transport, and warehousing.
- Safe for air transport - Powered by a compliant Li-SOCl₂ battery (IATA DGR, UN 3091, PI970 Section II), suitable for air shipment.
- Input voltage range: 0…264 Vac or 0…370 Vdc
- Input frequency: 0…60 Hz
- Input resistance: >2.4 MOhm
- Output: Modbus RTU – RS-485
- Resolution: 24 bits with DSP processing
- True RMS measurement
- Working isolation voltage: 1500 Vrms
- Operating temperature / humidity: -20…+60 °C / 10…90% (non-condensing)
- DIN rail mounting
- Power supply: 5…28 Vdc
- Warranty: 3 years
- T22CT can be used for network analysis, monitoring and measuring of non -sinusoidal and distorted networks AC current
- Variations of measuring current range (A): 0...50 / 100 / 150 / 200 / 250 / 300 / 400 / 500 / 600 / 750
- Output: 4…20 mA or 0…20 mA (Proportional change to input current)
- Frequency range of Measuring current: 50…60 Hz
- High electric isolation between primary conductor and output
- Mounting onto 35 mm DIN rail by means of optional supply of snap on mounting
- Auxiliary power supply: 24 V DC, ± 15%
- Protection class: IP20
- Operating temperature and Humidity: 0…+70 °C, 0...95% RH without condensation
- Voltage being detected in one of two ranges: 85...250 VAC or 170...250 VAC (settable by jumper)
- Galvanic isolation between the input voltage and output (OC)
- Low temperature drift
- Supplied by detected voltage
- Warranty: 3 years
Precise AC/DC current, voltage and resistance calibrator Inmel 7000.
- The Si-83 tank pump is perfect for residential A/C (up to 20 kW) and heating units (up to 40 kW)
- Max discharge head: 5,4 m
- Max pressure: 5,7 m
- Tank volume: 2 L
- Automatic turn on specific level in tank
- Overdraft level safety switch
- Stainless steel motor shaft
- Protection class: IP44
- Max condensate temperature: 55 °C
- Max condensate acidity: pH > 2,5 (Gas condensing boilers)
- Quick installation with mobile app
Adding preset counter Type 886.
- Display 3- or 5-digit, 4mm
- Protection class IP30
- Portable, small dimension temperature meter with a probe
- The probe can be 1,5 m, 3 m or of specified length
- Temperature measurement accuracy: ±1 °C
- Temperature measurement range: -50...+150 °C
- LCD screen
- 2 year warranty
- Supply: 1x6LF-22 (9 V)
The SV600 Fixed Acoustic Imager enables users to continuously detect, locate and visualize unheard and unseen air and gas leaks or changes in sound signatures before they become costly problems.
- 64 MEMS digital microphones for image of leaks
- Powerful processor for onboard real time processing: Sound classification, Frequency filtering, dB values and sound intensity mapping, Event triggering
- Measuring distance: 3…15 m
- Integrated visual light camera
- The SV600 can be mounted on moving applications – including as a Boston Dynamics Spot
- Can be mounted close to any equipment or asset, to any area of the production line, or where human access is restricted or dangerous
- Option for IO support through fieldbus coupler
- Integration: HTTP REST API, Modbus
- Operating temperature: -20…+50 °C
- Protection class: IP54
- Communication and power supply: Ethernet RJ45, POE IEEE 802.3at
- Air flow monitor with automatic reset function (alternatively available with error memory)
- Switching point continuously adjustable, switching output 2 NO/ 2 NC
- Robust sensor design, high sensor protection class IP67, sensitive and fast air flow detection
- Examples of areas of application: Monitoring of heating registers, humidifiers, air curtain systems, dampers, fans, DDC
- Operating on the Pitot tube principle
- Insensitive to airflow direction
- Accuracy: 2 %
- Pairs well with HK Instruments DPT-FLOW transducers
- Connection: 1/4” OD tubing
- Operating temperature: 5...95 °C
- Round or rectangular duct
- Various duct size options (up to 1200 mm)
- Air velocity measurement range: 0...2 / 0...10 / 0...20 m/s (selectable via jumper)
- Temperature measurement range: 0...50 °C
- Output: 0...10 V / 4...20 mA
- Option: LCD screen
- Option: relay output
- Supply: 24 VDC/VAC
- Operating temperature: 0...+50°C
- Protection class: IP54
- Maximal pressure measurement range: 0...7000 Pa
- Air flow and velocity measurement
- LCD screen
- Allowed overpressure: 25 kPa
- Supply: 9 V battery
- Operating temperature: 10...+50°C
- Protection class: IP54
- Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
- Air flow and velocity measurement
- Output: 0...10 V / 2...10 V or 4...20 mA
- Option: autozero function and LCD screen
- Allowed overpressure: 25 kPa
- Supply: 10...35 VDC
- Operating temperature: -40...+50°C (see datasheet)
- Protection class: IP54
- Universal airflow monitor with Safety Integrity Level 1 (SIL1) according to IEC 61508/IEC61511 (alternatively device with SIL2 certification available)
- With switching output suitable for control cabinet installation
- Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
- Large measuring range from 0.1 ... 30 m/s, quick and easy commissioning
- Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC
- Temperature measurement range: -30...+80 °C
- Humidity measurement range: 0...100 %
- Output: RS-485 Modbus RTU
- Calculates absolute humidity and dew-point temperature
- Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
- Operating temperature: -20...+60 °C
- Supply: 9...28 VAC/VDC
Ambient humidity and temperature logger TERMIOPLUS-S with external sensor is designed for logging of ambient humidity and temperature in its internal memory.
- Temperature range: -30...+70°C
- Temperature accuracy: In range -30...+70 °C: ± 0,3 °C
- Resolution: 0.1
- Humidity range: 0...100 % RH
- Humidity accuracy: ±2 %RH at 25 °C (30…70 %RH); ±3 %RH at 25 °C (10…90 %RH); ±4 %RH at 25 °C (0…100 %RH)
- Memory: 32000 (16000 temperature and 16000 humidity)
- USB interface for data download
- Logging interval: 15 s...10000 min
- Supply: 2xAA battery, 3.6 V
- Battery lifetime: 1 one year with 30 min. interval recording at +10 °C
- Size: 45 x 100 x 19 mm
- Analog gas detector MC for connection to DGC, MSC, WSB or any compatible gas detector
- Reliable self-monitoring: Integrated watchdog
- Precise signal: 4–20 mA (2–10 V) output for easy system integration
- Ethernet connection
- Analog outputs: 2 (0...20 mA / 4...20 mA / 0...24 mA / 0...5 V / 0...10 V)
- Digital outputs: 4 (PWM / ON/OFF)
- Relay outputs: 2 (NO/NC)
- Modbus TCP/IP support
- Webserver
- XML/JSON, HTTP API commands
- SNMP alarms (up to 5 recipients)
- Operating temperature: -10...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
Antenna radar level meter ARLM-54 designed for reliable level measurement of various liquids and pasty.
- Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
- Intelligent numerical signal processing with false reflection elimination
- Measuring range up to 8 m or up to 20 m
- Current output - 4...20 mA, HART communication
- Measurement independent of temperature and pressure of the atmosphere above the surface
- Possibility to measure even in aggressive vapors
- Operating temperature: -30…+70 °C
- Protection class: IP68
- Antenna radar level meter ARLM-70 "AMANDA" designed for reliable level measurement of various liquids
- Antenna radar level meter, works on the FMCW (Frequency Modulated Continuous Wave) principle with a frequency of 25 GHz
- FMCW antenna radar level gauge with a range of up to 20 m
- Teaching function to suppress false reflections
- Display of measured values on matrix OLED or LCD display
- Current output - 4...20 mA, HART communication
- Manual or remote adjustment
- Measurement independent of temperature and pressure of the atmosphere above the surface
- Possibility to measure even in aggressive vapours or vacuum
- Operating temperature: -30…+70 °C
Astronomical digital clocks RAT-TPA1B are applied for switching on and off the lightning or other electrical receivers in accordance to sunset and sunrise with an option to program a night break, which means a temporary switching off of the receivers for savings purposes
- 52 programs, holiday mode
- Automatic summer/winter digital clockover
- Automatic transfer of weekdays
- Sealable cover of the front panel, easy setting by 4 buttons
- Backlighted LCD display (can be turned off)
- 10-year power reserve (internal lithium battery which can protect real time clock and all the settings when the electric power supply is off)
- Number and type of contacts: 1 CO
- Rated load: 16 A / 250 V AC
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Compliance with standards EN 60730-1, EN 60730-2-7, Directive RoHS
The ATEX IBC Heater series is a safe, efficient, and customizable heating solution for IBC containers located in hazardous areas. IBC heaters are used for protection against frost, temperature maintenance and process heating in a wide range of industries.
Technical Specifications:
- Heats IBCs from -40°C to +200°C for steel, +80°C for plastic, ideal for industries like oil, gas, and pharmaceuticals.
- Fits standard 1000-liter IBCs, optional insulating lid, for indoor/outdoor use, IP65/I dust and water jet protection.
- Ready to use, fully configured with EC-type certificate, no additional acceptance needed.
- Variable voltage, power, and size options, for temperature classes T6 to T3.
- Compatible with optional ATEX controller for temperature management.
- Nominal voltage: 230 VAC*
- Nominal power: 2400 W (container heater) (insulation lid) without heating
- Max. operating temperature: +180°C / +200°C (steel IBC-Container), +80°C (plastic IBC-Container)
- Temperature class: T6, T5, T4, T3 (depending on temperature setting limiter)
- Electrical connection terminal boxes for network (EX-e) / sensor (EX-i)
- Protection class: IP65/I
- Zones 1/2 (gas); 21/22 (dust)
- Sensors: 2xPt100 (EX-i, EX-e)
- Weight: 30kg (container heater), 5kg (insulation lid)
The ATEX LB Series Drum Heater is engineered for safe and efficient heating in explosion-proof environments. Designed for drums in Zones 1, 2, 21, and 22, it delivers reliable performance with self-limiting heating technology. Ideal for maintaining low-temperature processes and frost protection, it features robust, anti-static PVC fabric and a user-friendly ATEX-certified junction box. Perfect for industries handling volatile chemicals or requiring stringent safety standards.
Technical Specifications
- Certification: CETS 23 ATEX 030 X; CETS 23 ATEX 031 U
- Zones: Suitable for Zones 1, 2, 21, and 22
- T-Class: T6, T5, T4, T3, T2, T1
- IP Rating: IP65 for dust and water resistance
- Operating Temperature: 65°C (energized) / 85°C (de-energized)
- Ambient Temperature: -20°C to +55°C
- Power Output: Self-limiting heating cable, adjustable to drum size
- Materials: Anti-static, water-repellent PVC fabric (B2 Flame Retardant)
- Connection Cable: 5m, 3G1.5mm² with ATEX-certified junction box
- Available Sizes: For 200/220L drums
- Applications: Frost protection, temperature maintenance, chemical processing