This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • Flexible spears for grain temperature measurement
  • Rigid construction
  • Diameter: Ø8 mm
  • Penetration depth: up to 12 m
  • Digital temperature sensor
  • Measurements are done using PC software or handheld reader GW-200
  • Temperature spears and cables can be integrated into single system

By means of three light barriers the SI-JET spray jet control systems check the density, symmetry, and cone angle of the spray jet. Choked or incorrectly set nozzles can thus be detected in time. Due to the integrated pressed air facility (at transmitter and receiver side of the fork) these systems are insensitive to dirt accumulation.

Stainless steel gauge cock, vent hole type. Technical specificationsProcess connection:  in case of 3 way gauge cock 1/2 (MxFxF), in case of 2 way gauge cock 1/4, 1/2, 3/8, (FxF), (MxF), (MxM); Operating temperature: up to 180 °C;Max pressure: up to 100 kg/cm²;Housing: stainless steel AISI 316 SS;  05-03 datasheet [EN] ..

Hydrostatic level meter HLM–25C is compact measuring device containing ceramic tensometric sensor and evaluation electronics in stainless steel probe. Ceramic sensor is resistant to lightly soiled, or sludge water. From the probe housing comes out 2-wire cable with capillary (for atmospheric pressure compensation). The front side of the sensor is open, therefore the level meter is resistant to capture gross (solid) impurities.

  • For continuous level measurement of clean, lightly soiled, or sludge water in non-pressure reservoirs, boreholes, tanks etc.
  • The measurement range up to 100 m (H2O)
  • The health certificate for contact with potable water available
  • Output: 4…20 mA or 0…10 V

Submersible level sensor CLS–23S is developed as reliable and low-cost solution for limit level sensing of water (or water solutions) with miniature outer dimensions without the needs of any adjustment. The connection is done by means of two wires directly to a circuit with relay or to binary input of control system.

  • For level detection of water in wells, boreholes or tanks
  • Two-wire connection directly to the relay circuit or PLC input (current switch)
  • Maximum immersion depth 100 m
  • Stainless steel protection basket avoids mechanical damages of electrode
  • Supply voltage: 6…30 VDC
  • Protection class: IP68
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution < 0,1 / 1,5 ppm SO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 2 / 5 ppm SO2
  • Attached or remote sensor
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution 0,1 / 1,5 ppm SO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...50 ppm SO2 / 0...2000 ppm SO2
  • Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265
  • Available versions with 2 to 8 primary windings
  • Nickel plated secondary terminals
  • Multiple mounting methods, including wall mounting and on DIN rail
  • Applicable standard: IEC 61869-1/2
  • Rated primary current: (2...8) x 5 A
  • Rated secondary current: 5 A
  • Rated burden: 5 / 10 / 15 / 20 / 25 A
  • Max system voltage: 720 V
  • Operating temperature: -25...+40 °C
  • Accuracy class: 0,5 / 1

RSP-E25-... is a Class I+II SPD for surge and lightning protection of low-voltage power supply systems, especially in high-risk exposure areas or building entrances in LPZ 0-2 (IEC 62305-4), protecting against damage caused by direct or nearby lightning strikes; suitable for use in main distribution boards.

  • IEC / EN / VDE category: Class I+II / Type 1+2 / B+C
  • Application: main distribution boards (MB)
  • Power networks: TT, TN-S, TN-C
  • Protection modes: L-N, N-PE
  • Protective elements: MOV, MOV+GDT
  • Enclosure: modular (replaceable module)
  • Mechanical status indicator: green/red flag
  • Compliant with standards: IEC/EN 61643-11:2011, IEC 60364-4-53, IEC 62305, CE, RoHS
  • Destined to synchronize generator, wind, water turbine and similar devices connecting to the network
  • Eliminate voltage difference, frequency, and phase shift angle
  • Ethernet interface 10/100 base-t, RS-485 interface with Modbus RTU protocol
  • Web server, Modbus TCP / IP, DHCP server
  • Protection class from frontal side: IP65, terminal side: IP20
  • Electrical safety CAT III measurement category
  • Voltage range (resolution): 20...180 V (0,1 V), 60...480 V (0,1 V), ...1920 kV (0,01 kV)
  • Voltage difference (resolution): -20...0…20 % (0,1 %)
  • Frequency range (resolution): 45...65 Hz (0,001 Hz)
  • Frequency difference (resolution): -10...0...10 % (0,01 %)
  • Phase shift (resolution): 0...360 o (0,1 o)
  • Universal datalogger with 3 hardware MiniDIN inputs for connecting temperature and humidity probes and 1 for external CO2 sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • External CO2 sensor, 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Memory: up to 70 000 records
  • Up to 8 1-Wire and Modbus RTU sensors support
  • Temperature, humidity and dew point graphical representation
  • Modbus TCP/IP support
  • XML/JSON and HTTP API commands
  • Webserver
  • E-mail alarms (up to 5 recipients)
  • Operating temperature: -20...+55 °C
  • Warranty: 3 years
  • Supply: 10...32 VDC
  • Measures ambient temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+80 °C, 0...100 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures ambient temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+105 °C, 0...100 %RH
  • External sensor cable length: 1 / 2 / 4 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30 for device, IP40 for sensor
  • Calibration certificate included
  • Measures ambient air temperature and humidity
  • Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time
  • Temperature measurement range (depends on probe type): -30...+80 °C / -50...+125 °C / 0...+50 °C
  • Humidity measurement range: 0...100 %
  • 4 channels: 4 x external temperature probes or 4 x external temperature and humidity probes
  • Output: Ethernet
  • Measurement interval: 2 s
  • Communication protocols: WWW, Modbus TCP, SNMPv1, SOAP, XML
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Included calibration certificate
  • Supply: 5 VDC
  • Protection class: IP30
  • Selectable double set point
  • Selectable TC / Pt100 input (order option)
  • Output: relay (control or alarm) and SSR (control)
  • PID control
  • Self-tuning feature
  • Soft-start function
  • Offset feature for input
  • Heating/cooling control
  • Manual control feature
  • Two set points
  • Input: TC (J, K, T, R, S) / RTD (Pt100)
  • Control output: relay or SSR
  • Auxiliary output: relay
  • PID / ON-OFF control
  • Auto-Tuning / Self-Tuning
  • Alarm modes: deviation, absolute
  • Heating / cooling control
  • 4+4 digits high contrast LED display
  • Supply: 85…270V AC / DC
  • Ambient temperature: 0…50 °C
  • Temperature measurement range: -90...+260 °C
  • Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -30...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP67
  • Warranty: 3 years
  • Inputs: 4 x Pt1000
  • Temperature measurement range: -90...+260 °C
  • Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+60 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP67
  • Warranty: 3 years
  • Input: 4x external Pt100 sensors
    • Measuring range: -200…+260 °C
    • Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
    • Resolution: 0,1 °C
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: adjustable 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP20
  • Warranty: 3 years
  • Inputs: 4x external sensors + 1x internal temperature sensor
  • 3x Thermocouple type B, J, N, S, T external temperature sensor
    • Measuring range: according to the connected thermocouple
    • Accuracy: ± 0,4 °C
    • Resolution: 0,1 °C
  • 1x PT1000 external temperature sensor
    • Measurement range: -200...+260 °C
    • Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
    • Resolution: 0,1°C
  • Internal temperature sensor
    • Measuring range: -30…+70 °C
    • Accuracy: ± 0,4 °C
    • Resolution: 0,1 °C
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: adjustable 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP20
  • Warranty: 3 years
  • Temperature measurement range: -100…+300 °C
  • Accuracy: ±0.07 °C (-10…+100 °C); ±0.15 °C (+101…+150 °C); otherwise ±0.4 °C
  • Resolution: 0.01 °C
  • Memory: 32 000 readings
  • Power supply: battery 3.6V 1/2AA
  • Operating temperature: -30…+70°C
  • Protection class: IP65
  • Wall mount available as optional accessory
  • Temperature measurement range: -100…+300 °C
  • Accuracy: ±0.07 °C (-10…+100 °C); ±0.15 °C (+101…+150 °C); otherwise ±0.4 °C
  • Resolution: 0.01 °C
  • Memory: 32 000 readings
  • Power supply: battery 3.7V 1/2AA (Charging time: 1,5 h)
  • Operating temperature: -30…+70°C
  • Protection class: IP65
  • Wall mount available as optional accessory
  • Inputs: Pt100, thermocouples J, K
  • 4-digit 20 mm LED screen
  • Automatic or manual compensation
  • Programmable input, decimal point, averaging time
  • 24 VDC output for external transducers
  • Galvanic isolation
  • Supply: 230 VAC / 240 VAC / 20...40 VAC / 20...40 VDC
  • Protection class: IP65
  • Patented quality product (immersion sensor patent)
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: 0 – 10 V or 4...20 mA
  • Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
  • Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
  • Medium: in liquid or gaseous media
  • For aggressive media, stainless steel immersion sleeves must be used
  • Ambient temperature: -30…+70 ºC
  • Sensor for remote temperature monitoring over the Internet (Ethernet interface)
  • Webserver function
  • Ideal for server, air conditioning, HVAC, warehouse, museum and factory temperature monitoring
  • Remote alarm (meter sends an e-mail when the set temperature range is breached)
  • Archive in CSV format
  • MODBUS TCP protocol
  • Calibration certificate included
  • 3 year warranty

Data recorder with printer T-PRINT G0221E, G0241, designed for transportation temperature measurement.

 

Models:

T-PRINT G0221E – with printer,

T-PRINT G0241 – with printer and RS-232 output.

 

Complies with EN 12830, Class 1 and EN 13486, Class 1 standards for food transporation.

 

Appliance: food, pharmacy, flower, animal and other goods transportation temperature measurement. Designed to be mounted in driver’s cabin.

Temperature recorder with printer T-PRINT G0841, designed for transportation temperature measurement.

 

Models:

T-PRINT G0841 – with printer

T-PRINT G0841M – with integrated GSM modem

T-PRINT G0841MW – with integrated GSM modem and wireless output

T-PRINT G0841W – with wireless output

 

Complies with EN 12830, Class 1 and EN 13486, Class 1 standards for food transporation.

 

Appliance: food, pharmacy, flower, animal and other goods transportation temperature measurement. Designed to be mounted in driver’s cabin.

  • Penetration temperature sensor TJ-ST
  • Sensor type: Pt100, Pt1000
  • Accuracy: A or B
  • Measuring range: -30 °C...+180 °C
  • Measuring part diameter: Ø 4 mm
  • Measuring part length: 100 mm
  • Material: stainless steel
  • Various sizes are available depending on customer requirements and drawings
  • Temperature sensor AUREGIS TJ-H with hygienic – food process connection and special welded slot, designed for temperature measurement from -50 to +400 °C
  • Temperature sensor construction specially designed for usage in food, pharmaceutical, water extraction and water purification, biotechnology and other industries
  • Temperature sensor and slot are made of stainless steel
  • Measuring range: from -50°C to 250°C, 400 °C
  • Temperature sensor AUREGIS TJ-H with hygienic – food process connection and M12x1 4 pin connector
  • Sensor type: RTD (Pt100, Pt1000), TC (K, J)
  • Accuracy: A or B
  • Measuring range: from -50°C to 400°C
  • Sensor tube:
    • Length: 100, 180, 200 mm
    • Diameter: Ø6/8/10 mm
    • Material: stainless steel
  • Process connection tread: G1/2
  • Transmitter output type: 4...20 mA, 4...20 +HART, 0-10 V, RS-485 other parameters acc. to requirement
  • Cable connector: M12x1 4 pin
  • Various sizes are available depending on customer requirements and drawings
  • Sensor type: Pt100, PT1000, K, J, PTC, NTC, Ni120, Ni1000
  • Measurement range: -30...180 °C
  • Cable: 2, 3, 4-wire
  • Magnetic mounting ring

TJ-1V sensor is convenient for installation on pipes with staples. For HVAC systems.

  • Measurement range: -30...+105 °C
  • Sensor type: PT100, PT1000, PTC, NTC, Ni1000, TC K
  • Sensor measurement material: brass
  • Cable of two or three wires with PVC isolation. Cable length: on request

Temperature sensor AUREGIS TJ-PL6 is integrally connected to the cable. Protection from UV

Purpose: solar panels and other surfaces.

  • Sensor type: PT100, PT1000, PTC, NTC, Ni1000
  • Sensor working temperature range*: -40...+90 °C
  • Cable wires*: 3-wire
  • Sensor material: aluminum
  • Plate diameter / thick: Ø30 mm / 10 mm
  • Cable length: according to order

* - we produce according to individual orders

  • Temperature sensor with penetration probe, “T” type handle and cable connection head
  • Various sizes are available depending on customer requirements and drawings
  • Sensor type: Pt100, Pt1000, K, J
    • Accuracy class: A or B / cl. 1 or 2
    • Measuring range: -30...180 °C or -30...260 °C on request
  • Sensor’s tube:
    • Material: Stainless steel AISI304 (1.4301)
    • Diameter: Ø 6 / 8 / 10 mm
    • Length: 100, 200, 500, 700, 1000 mm on request
  • The total length of the sensor handle is 220 mm
  • Connection head:
    • Type: M, B (transducer on request)
    • Protection class: IP65
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-1 is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
  • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
  • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-4 is selected according to the individual order
  • Mounting box:
  • Material: Polystyrene
  • Dimensions: 64,4x 88,4x 42,2mm
  • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer
  • Sensor type: Pt100, Pt1000, Ni100, Ni1000, others
  • Electrical connection:
    • A transmitter with output: 4…20 mA, 4...20 mA +HART, 0…10 V, RS-485 or IO-LINK
    • 2-wire, 3-wire, a contact terminal
  • Measuring range: -40…180 °C (depends on probe)
  • Operating temperature (case with transmitter): -40…80 °C
  • The sensor TJ-S is selected according to the individual order
  • Mounting box:
    • Material: Polystyrene
    • Dimensions: 64,4x 88,4x 42,2mm
    • Protection class: IP65
  • The design could be changed according the requirements and drawings of the customer

The TJ-S temperature sensor is permanently connected to a cable and designed for measuring temperatures from -50°C to 400°C.

Various cable lengths are available.

  • Sensor type: PT100, PT1000, NTC, Thermocouples K, J
  • Measuring range: -50…+400 °C
  • Operating temperature:
    • -30...+70 °C (PVC isolation)
    • -50...+180 °C (Silicone isolation)
    • -50...+400 °C, kabelio -50...+250 °C (Teflon isolation)
    • -50...+400 °C, kabelio -50...+400 °C (Fiberglass isolation)
  • Cable and connection: 2, 3, 4 wire
  • Sensor tube:
    • Material: Stainless steel 316 (1.4401)
    • Diameter: Ø4 mm
    • Length: 120 mm
  • Temperature sensor TJ1TE – NTC10k3B HVAC developed for air conditioning devices and heating, ventilation, (HVAC) systems
  • Measurement range: -30…+105 °C
  • Sensor: NTC; Rnom = 10 kΩ at +25 °C; steepness β = 3977 (+25...+85 °C)
  • Accuracy: enhanced accuracy ± 0.2 % in range 0...+75 °C, in the rest ± 1 %
  • Measuring part housing: PVC; dimensions 4,5 x 90 mm
  • Cable of two wire with PVC insulation: standard lengths - 0,1 m; 1,5 m; 3 m; 6 m
  • Protection class: IP54
  • Fastening with rubber sleeve and / or flange holder according to the drawing (see drawing above)

RTD sensors with TOPGDM, TOPGDS connectors. With threaded process connector, designed to measure temperature in pipes, tanks and canals. Measuring range is -50...+400 ºC. Can be fit with a LED display.

  • Temperature range: from +20...+110 °C iki +40...+300 °C
  • Output signal: 1 floating change-over contact
  • Process temperature: +20...+300 °C
  • Approval: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, RMRS, EN60730-1/ EN60730-2-9: Typ 2.B.H
  • Protection class: IP65
  • Input: RTD: Pt100 (2-wire) / TC: K
  • Output: relay (NC/NO)
  • Configuration: via HART (switching point, hysteresis, switching delay, damping), with magnet (switching point)
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC
  • Operates as a temperature switch (thermostat), transducer, data logger
  • Accumulated temperature data is read using a mobile phone with NFC interface
  • Parametrization via NFC interface
  • Display and electrical connection are independently rotatable 335°/343°
  • Temperature measurement range: -50...+150 °C
  • Analog output: 4...20 mA / 0...5 VDC /1...6 VDC / 0...10 VDC / switchable between mA and V
  • Switch output: 2 x PNP
  • Sensor: Pt1000 A
  • Data logger memory: 3518 measurement points
  • Measurement interval: 0,1...999,9 s
  • Operating temperature: -25...+85 °C
  • Supply: 15...30 VDC
  • Temperature transmitter 5331A with 4...20 mA output, designed for TC, RTD, mV signal conversion to analog
  • To be mounted into B-type electric head
  • Temperature transmitter 5333A with 4...20 mA output, designed for RTD signal conversion to analog
  • To be mounted into B-type electric head
Loading...