- Designed to be weld-in into pipelines and boilers
- Instrument standard threads (F): G1/2", G1/4"
- Dimensions according to customer's needs
- Case production: solid or welded
- Available materials: 1.4301 (AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
- Dimension tolerances according to DIN ISO 2768
- Available other materials, threads, flanges and dimensions
- Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
- Standard instrument threads (F): G1/2", G1/4"
- Dimensions according to customer's needs
- Case production: welded or solid (flange welded)
- Available materials: 1.4301(AISI304), 1.4401 (AISI316), 1.4404 (AISI316L)
- Dimension tolerances according to DIN ISO 2768
- Available other materials, threads, flanges and dimensions
Solid drilled threaded thermowells, protective cases:
- Protect and extend the lifetime of temperature sensors and thermometers in processing applications
- Facilitate the replacement of sensors
- Allow sensor maintenance without process interruption
A and B connection threads:
G1/4, G1/2, M20x1,5, M10x1, M12x1,5, M20x1,5, G3/4, M16x1,5, M22x1,5,
Spec, G1/2L*
* - left-hand thread
Material: stainless steel-DIN 1.4301 (AISI 304)
Note: other ordering versions possible.
Thermowells protect and extend the lifetime of temperature sensors and thermometers in processing applications where the sensors are not mechanically or chemically compatible with the process environment. Moreover, thermowells facilitate the replacement of sensors and allow sensor maintenance without process interruption.
The mini-size multimeter has multiple functions, such as auto range, auto scan (SMART) and true RMS functions, which makes it more convenient and intelligent. Besides normal multimeter function, it also has the function of NCV test and LIVE wire test, which is convenient for field testing. Blacklight and Flashlight capabilities facilitate use in dark work environment.
- CAT III 600V
- TRMS
- AC/DC Voltage measurement: 400 mV…400 V
- AC/DC Current measurement 40 mA … 10 A
- Resistance measurement 400 mΩ … 40 MΩ
- Capacitance measurement 4 nF…4 mF
- Frequency measurement
- Temperature measurement -200…1200 °C
- Auto Scan function (SMART)
- HOLD function, Continuity test and Diode test
- Dimensions: 130 x 62 x 27 mm
- Measures ambient air pressure
- Measurement range: 600...1100 hPa
- Operating temperature: -30...80 °C
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Protection class: IP30
- Calibration certificate included
The high temperature base drum heater heats metal drums from the bottom, with a diameter of 555mm, compatible with all size metal drums up to 200 liters. It has a built-in thermostat ranging from 50 to 300°C and can be combined with a traditional drum heater for faster heating. It can be used to heat a variety of industrial liquids.
Technical description:
- Tubular heaters.
- 50mm. Rockwool isolation.
- 3-meter power cable.
- Thermostat: 50° to 300ºC.
- Weight: 15kg.
- Can easily be used in conjunction with other drum heaters or insulation jackets for faster heating.
- IP 54.
Ideal for heating up:
- Water.
- Oils and also diesel fuel.
- Resin.
- Vaseline.
- Wax, e.g. lanolin (wool wax or wool grease).
- Fats.
- Glue.
- Adhesives.
- Module is designed to protect battery if it discharges below 10,5 V mark, disconnecting it from load
- Battery is automatically reconnected to load if its voltage rises
- Suitable for work with heaters, lighting, travel refrigerators, etc.
- Operating voltage: 12 V ZBxx, 24 V ZBxx-24V, 48 V ZB-48V
- Maximal current: 40 A ZB40, 80 A ZB80, 140 A ZB140
- Operating temperature: -20...50 °C
- Dimensions: 65 x 89 x 70 mm
The BDX-30 and BDX-20 is the newest in the legendary “BD Series” pin meters for the building trades. This rugged meter has an ergonomic design with an easy grip handle and large tactile buttons for comfort and usability. Equipped with a custom, LCD display and intuitive user interface, users can quickly obtain accurate readings.
- Large, custom display with auto backlight - easy to read under all conditions
- On-screen statistics for up to 100 readings saved to the meter
- High, Low, Average, Standard Deviation
- Measuring Range:
- Wood (Douglas Fir) 6%-60%
- Drywall 0.1%-6%
- Reference 1-100
- Wood temperature correction (°F / °C)
- Select from 37 wood species and materials
- Bluetooth® connectivity to EDGE® app (BDX-30)
- Timestamp and geotag, Data export to .csv format, Save unlimited readings
- Color-coded LED’s – adjustable through EDGE® app (BDX-30)
- Alarm set point - alerts to user-selected MC level
- Internal calibration check
- "Low Batt" warning with audio
- Auto off timer. Set to 1m, 4m or 10m
- Compatible with all Delmhorst electrodes
- Power: 2x AA Alkaline batteries
- Temperature Correction Range: 0…255 °F (-18…+124°C)
Moisture measuring of sand, minerals, clay, grain, foodstuffs, sawdust, ores, sewage sludge. During operation, the sensor requires nothing but a power supply and a display or a controller that can receive the measurement signal. The BMMS sensor is designed for applications in which no multi-part systems are to be used but still the highest precision is required. Due to the in-process calibration, all potential interference from the sensor installation is directly compensated for.
The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Storage temperature: -40℃ to 60℃
- Operating temperature: -10℃ to 50℃
- Operating altitude: Up to 2000 meters
- Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- 35% up to 55℃
- Power requirements: 6 x AAA batteries
- Size: 204mm (L) x 99mm (W) x 46mm (H)
- Weight: 460g (including battery)
The VA700 Loop Calibrator is a versatile source and measurement tool. It is designed to measure or output a 0 to 24 mA DC current loop and 0 to 20 V DC voltage. The calibrator cannot measure and source simultaneously.
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Storage temperature: -40℃ to 60℃
- Operating temperature: -10℃ to 55℃
- Operating altitude: Up to 3000 meters
- Temperature coefficient: ±0.005% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- 35% up to 55℃
- Shock: Random 2g, 5Hz to 500Hz
- Safety: 1 meter drop test
- Power requirements: 6 x AAA batteries
- Size: 204mm (L) x 99mm (W) x 46mm (H)
- Weight: 460g (including battery)
The VA710 Thermocouple Calibrator is a high-accuracy handheld instrument for calibrating thermocouple instruments. It measures or simulates 8 types of thermocouples (°C or °F) and millivolts. It cannot measure and source simultaneously.
- Measure or simulate: Millivolt and 8 types of thermocouples (°C or °F)
- Display: Large 5-digit LCD with full-angle visibility
- Accuracy: Max. up to 0.3℃ and 0.025% for mV
- Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
- Temperature coefficient: ±0.02%/℃ (from 0℃ to 18℃ and 28℃ to 50℃)
- Storage temperature: -40℃ to 60℃
- Operating temperature: 0℃ to 50℃
- Operating altitude: Up to 3000 meters
- Relative humidity:
- 95% up to 30℃
- 75% up to 40℃
- 45% up to 50℃
- Shock: Random 2g, 5Hz to 500Hz
- Safety: 1 meter drop test
- Fuse: F 0.125A/250V
- Power supply: 6 x AAA 1.5V batteries or Standard jack for external power supply
- Size: 205mm (L) x 98mm (W) x 46mm (H)
- Weight: 472g (including battery)
- Voltage range: 0,2...1000 V
- Current range: 20 mA...20 A
- Frequency range: 40...5000 Hz
- DC voltage and currency accuracy: 0,02 %
- AC voltage and currency accuracy: 0,05 %
- Load capacity up to 40 VA
- USB, RS232 interfaces
- Ambient temperature: 23 °C ±5 °C
Portable calibrator for DC voltage and current.
Purpose:
- Calibration and verification of temperature measurement equipment
- Measurement and control equipment monitoring
- Current loop circuit monitoring
Portable calibrator for tuning of thermoelectrical sensors.
Purpose:
- Calibration and verification of temperature measurement equipment
- Calibration and verification of transducers
- Tuning of measurement and control systems
Portable calibrator for RTD sensors.
Purpose:
- Calibration and verification of temperature measurement equipment
- Measurement and transducer calibration and verification
- Control system tuning
Universal calibrator-meter Inmel 60 for automation tuning.
- For continuous level measurement of diesel in trucks, building machines, locomotives, etc.
- Output: 4...20 mA / 0...10 V / CAN
- Direct mounting into a tank through the 5-hole flange or G1” thread
- Arbitrary electrode length (up to 1 m)
- Setting by means of magnetic pen
- Ambient temperature: 9...30 VDC / 12...30 VDC / 9...30 VDC
- Protection class: IP68
- CLM-70 for continuous level measurement of liquids, bulk solids in all industrial branches
- Stainless steel design suitable for the food and pharmaceutical industries
- Output: 4...20 mA with two-way HART
- Process connection: G1”, G1 ½”, NPT 1" threads and Tri-Clamp (Ø 50.5 or 64 mm)
- Arbitrary electrode length (up to 20 m)
- Display of measured values on matrix OLED or LCD display
- Power supply: 18…36 V DC
- Protection class: IP67
- For continuous level measurement of liquid and bulk-solid materials
- Output: 4...20 mA / 0...10 V
- Universal usage, direct mounting into tanks, vessels, sumps or silos and hoppers
- Setting using a magnetic pen
- Possibility of linear measurement even in non-conductive or variously shaped vessels
- LED indication
- Versions with coated electrodes for aggressive or electrically conductive media
- Versions for explosive areas
- Ambient temperature: -40...85 °C
- Supply: 9...34 VDC / 12...34 VDC
- Protection class: IP67 / IP68
- Detection of various types electrical conductive or non-conductive liquids (water, water solution, cooling liquids, oil, ets.)
- Direct mounting into various containers, vessels, tanks, ets.
- Output: S, PNP, NAMUR (for explosive areas)
- Sensitivity setting by means of magnetic pen
- High temperature performance, pressure resistance up to 7 MPa
- Process coupling: thread M18, M20, G3/8“ or 1/2–14 NPT
- Versions for usage in explosive areas
- Supply: 6…30 VDC
- Protection class: IP68
- Universal use for limit level sensing of liquids and bulk solids
- Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
- Output: NPN, PNP, NAMUR (for explosive areas)
- Sensitivity and hysteresis fluently adjustable
- Process coupling: thread M27x2; M30x1.5; G3/4“ or Triclamp
- Indication by LED
- Versions for explosive and flammable areas
- Supply: 7…36 VDC
- Protection class: IP67
- Universal use for limit level sensing of liquids and bulk solids.
- Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
- Output: NPN, PNP
- Setting using a magnetic pen
- High stability upon high sensitivity (possible to use for materials with εr ≥ 1.3)
- Indication by two LEDs
- Versions for explosive areas
- Supply: 8…9 VDC
- Protection class: IP67 / IP68
- SET-1000 + SET/OSK2 is designed for oil detection on water surface
- Can be used in tanks where water level is alternating
- Control device SET-1000 is a one-channel level switch
- SET/OSK2 sensor detects more than 15 mm width hydrocarbon layer on water surface
- Polypropylene floats
- ATEX certified
- Wall-mounted, IP67
- Supply: 230 VAC, 50/60 Hz
Carbon dioxide (CO2) and temperature transmitter with a display CDT2000 Duct. The device is designed for measurement of air parameters in ventilation channels.
- CO2 range 400...2000 ppm
- Temperature range 0...50 °C
Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.
- Carbon dioxide (CO2) range: 400...2000 ppm
- Humidity range: 0...100 %
- Temperature range: 0...50 °C
Stable long-life optical NDIR gas sensor
Range 0...10 000/50 000 ppm CO2
Resolution 1/100 ppm for 10K/50K range CO2
Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
Remote probe option
- Stable long-life optical NDIR gas sensor
- Range 400...5 000/10 000/50 000 ppm CO2
- Resolution 10 ppm CO2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Remote probe option
- NDIR gas sensor
- Range: 0...10 000 ppm CO2
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: 0...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC as options
Carbon dioxide transmitter CMT is designed for CO concentration measurement. The transmitter is used to control interior ventilation systems.
- CO range 0...300 ppm
- Stable long-life electrochemical gas sensor
- Range 0....1000 ppm CO
- Resolution 1 ppm CO
- Default alarms at 25 ppm / 35 ppm CO
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range: standard 0....200 ppm CO, maximal 0...1000 ppm CO
- Resolution 1 ppm CO
- Default alarms at 25 ppm / 125 ppm CO
- Outputs 2 x relays with switch-over contacts
- Visual and acoustic alarms
- Long-life electrochemical cell
- Range 0....1000 ppm CO
- Resolution 1 ppm CO
- Outputs 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range 0....200 ppm CO
- Resolution 1 ppm CO
- Outputs 2 x relays with switch-over contacts
- UART digital interface
- Visual and acoustic alarms
- Magnetic key switching
- Electrochemical gas sensor
- Range:
- -- 0…300 ppm CO
- -- 0...1000 ppm CO
- Resolution: 1 ppm CO
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Addressable digital gas detection system (Sensor-Board SB) for combustible, toxic and refrigerant gases.
- Communication: RS-485 interface for stable and secure system networking
- Precise Detection: High accuracy thanks to digital signal processing
- Easy maintenance with X-Change: Plug & Play systems for fast, convenient service
- Robust Design: Reliable with IP65 even under extreme conditions
- The versatile Si 2052 is suitable for replacement of some market standards drain pumps used in cassette type air-conditioning units up to 20 kW
- Max discharge head: 0,9 m (flow rate = 24 l/h)
- The single level detection unit can be used as a safety contact (NC 50 VA resistive – 250 V) to cut off automatically the air conditioning system compressor or solenoid valve
- The centrifugal technology inside this pump is specifically designed for removing condensates continuously, in any kind of environment, with a very low sound level (≤ 30 dBA)
- Protection class: IPX4
- Operating conditions: 100 % - continuous duty
- Lokaset 20 is designed for high wastewater level detection in septic tanks
- Easy to install, does not need calibration
- Switch output
- Visual and acoustic alarms
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- Stable long-life electrochemical cell
- Range 0...20 ppm Cl2
- Resolution 0,02 ppm Cl2
- Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
- Default alarm set-points 0,5 ppm/1 ppm Cl2
- Remote probe option
- Stable long-life electrochemical cell
- Range 0...20 ppm Cl2
- Resolution 0,02 ppm Cl2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Remote probe option