  • Real-time thermal line-scanner system for continuous or discrete process measurements
  • Up to 1024 measurement points per line
  • Fast scan rates up to 150 lines per second (real-time 150 Hz thermal imaging)
  • Optical resolution up to 200:1
  • Built-in line laser for rapid alignment
  • On-board Ethernet TCP/IP communication
  • PC independent alarm output
  • PC independent 4...20 mA interfaces (3 outputs)
  • Wide choice of models and spectral responses
  • Rugged, waterproof IP65 enclosure
  • Water cooling for ambient temperature up to 180 °C
  • Noncontact infrared temperature meter 3i Plus (pyrometer), designed for metalworking industry where casting, hardening, heating take place. Also suitable for ceramics, semiconductor, chemical furnace temperature measurement
  • It is a new generation, small size IR device for high temperature measurement
  • Precise high-resolution optics guarantee high accuracy, resistant casing let the device survive falls from up to 1 meter height
  • That said, measurements can be done in various environments and from various distances
  • Noncontact stationary infrared temperature meter CM for temperature measurement
  • Range: -20...500 °C
  • Outputs: 0...5V, or TC K / J type (chosen while ordering)
  • Software “DataTemp Multidrop” for remote monitoring and configuration
  • Noncontact infrared thermal meter (pyrometer) ENDURANCE
  • for temperature measurement up to 3200 ºC with the resolution of 0,1 ºC
  • Outputs: Ethernet, profinet, 0/4...20mA (isolated), RS485, relay 48V and 300mA
  • Web server
  • Wider area can be measured when used with SpotScan
  • Noncontact infrared thermal meter Marathon MM, wide range of accessories for various applications
  • Range: -40...3000°C (in fixed ranges)
  • Outputs: 0/4...20mA, RS485, mechanical switch
  • Temperature measurement range: -40...+2250 °C (different versions)
  • Advanced signal processing
  • Wide choice of focus distances
  • Durable stainless steel IP64 enclosures designed to withstand ambient temperatures from -20 to 85 °C
  • Integrated laser sighting
  • Galvanic isolated outputs
  • Plastic lens option for food application
  • Analog input for ambient compensation and adjusting emissivity setting
  • USB for easy setup
  • Simple, two-wire or digital installation
  • Backward compatibility to old Raytek and Ircon in class sensors and accessories
  • Noncontact infrared thermal meter Thermalert TX, additional accessories for various applications
  • Can be used in an explosive area
  • Range: -18...2000 °C (in fixed ranges)
  • Outputs: 4...20mA, HART į RS232, mechanical switch (depends on version)
  • Grain temperature monitoring system software for PC
  • Collects data from temperature cables GWSL 1100 and GWSL 2100 and spear temperature sensors GWTL-R
  • Stores, visualizes data in charts
  • Alarms
  • Level indication
pH / ORP microprocessor transmitter, 4-20 mA - RS485 – Modbus, PH 3436 New

The instrument uses a pH/ORP sensor and RTD Pt100 temperature sensors. If the Pt100 is connected the transmitter makes automatic temperature compensation (pH only).

  • pH range: 0 ÷ 14.00 pH
  • ORP range: 0 ÷ 1000 / 0 ÷ -1000 / -1000 ÷1000 / 0 ÷ 2000 / 0 ÷ -2000 mV
  • Temperature range: -10.0 ÷ 110.0 °C / 14.0 ÷ 230.0 °F
  • Resolution: 0.01 pH, 1 mV, 0.1 °C
  • Digital output: RS-485 isolated
  • Analog output: 4-20 mA galvanically isolated, "current loop" two wires
  • Power supply: 9 / 36 Vdc
  • Dimensions: 71x95x58 mm. Rail Din (4 modules)
  • Operating temperature: 0…+50 °
  • EMC/RFI conformity: EN 61326

Instrument PH135 is designed for liquid pH, ORP and temperature measurement.

  • pH measuring range: -1.00/15.00 pH, accuracy 0.01 pH
  • ORP measuring range: -1200/+1200 mV, accuracy 1 mV
  • Temperature measuring ranges: -10.0/+110.0 °C ;  -14.0/+230.0 °F
  • Alphanumeric LCD display
  • Manual and automatic temperature compensation
  • Manual or automatic calibration
  • Automatic recognition of buffer solutions
  • Data logging up to 100 measures
  • Alcaline 9 V battery
  • Dimensions: 92 x 155 x 33 mm  -  Weight:  approx. 300 g 

PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T4611, T3611, T7611. Only to be used with external sensors.

Application:

  • Storage rooms
  • Greenhouses
  • Telecommunication devices
  • Servers
  • A/C units

PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T0610, T3610, T7610. Only to be used with internal sensors.

Application:

  • Storage rooms
  • Greenhouses
  • Telecommunication devices
  • Servers
  • A/C units
  • RS-485 protocol temperature and humidity sensor
  • Temperature measurement range: -20...+60 °C
  • Accuracy: ±0,13 °C
  • Resolution: 14 bits
  • Very low current consumption
  • Warranty: 3 years
  • Connection: RJ-45
  • Measurement range: -40...+150 °C
  • Temperature measurement accuracy: ± 1,3 °C
  • Operating temperature: -20...+50 °C
  • Used with wireless manifold
  • Cable of 2 m length
  • 124 refrigerant gases

Temperature regulator RE72 for ladder control, designed for temperature stabilization in plastics and food industries.

 

  • Universal measurement input
  • Auxiliary measurement input 0/4...20 mA
  • Binary input
  • Ladder temperature control, 15 programs with 15 intervals
  • Soft start
  • ON/OFF, PID, PID step-by-step (step valve control) or PID heating – cooling
  • 8 alarm types, alarm control
  • Timer function
  • Front panel protection class IP65
  • Backside protection class IP20

Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.

  • Ethernet connection
  • Digital inputs: 2
  • 1-Wire input (up to 2 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • Webserver
  • HTTP and XML API commands
  • E-mail alarms, SMTP, SNMP
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC

Room thermostat, temperature switch with an electric socket RTBSB-001.401.

RTD sensors TOPE with cable. Technical specifications Example Model Range Protective tube Cable insulation TOPE150 -50 .. +400°C Ø5, Ø6, Ø8, Ø9, Ø10 mm PVC, silicone, teflon, glass fiber TOPE3 -50 .. +400°C Ø5, Ø6, Ø8 mm TOPE4   TOPE310 -50 .. +400°C Ø5, Ø6, Ø8 mm ..
RTD sensors TOP with connection head. Technical specifications Example Model Range Accuracy Tube diameter TOPGB -50…+150°C A class (standard)orB  class according to EN 60751 various variants available TOPGN -200…+600°C TOPG -200…+600°C TOPI -200…+600°C ..
RTD sensors TRP with mineral insulation. Technical specifications Example Model Range Diameter TRP-NA -50 .. +600°C Ø1.5 .. Ø6.0 TRP-BTW -50 .. +600°C Ø1.5 .. Ø3.0 TRP-WL -50 .. +600°C Ø1.5 .. Ø6.0 TRP-TKbW -50 .. +600°C Ø1.5 .. Ø6.0 ..
  • Up to 60 logical channels for data logging (max. up to 8 analog channels)
  • Inputs:
    • Measuring programmable: 0, 4 or 8
    • Binary: 2 or 6
    • Modbus RTU Client: 10 devices, 10 registers each
  • Outputs:
    • Relay: 2, 6 or 8
    • Analog 0 / 4...20 mA: 0, 4 or 8
    • Supplying output for external devices: 24V d.c. / 30 mA
  • Communication interfaces:
    • RS-485 MODBUS (Client and Server)
    • Ethernet: MODBUS TCP/IP, Webserver (www), FTP
    • USB Host 2.0
  • Screen: Graphical color display LCD TFT 3.5”
  • Internal memory 8 GB for Archiving of measured parameters
  • Visualization of measurements in digital form, analog indicators, line charts, bargraphs
  • Advanced mathematical functions on measured values
  • Archiving and visualization of measuring data transmitted to KD6 from external devices via RS-485 MODBUS 
  • Settings secured with access password
  • PC software for easier setup
  • Protection class: IP65 (front)
  • Operating temperature: -10...55 °C
  • Supply: 85...253 V a.c., 90...300 V d.c. or 20...60 V d.c.
  • Measurement channels: up to 24
  • Analog inputs: 12
  • Relay outputs: 6 or 32
  • Analog outputs: 4 or 8
  • Digital outputs: RS-232, RS-485, USB
  • Screen: touchscreen LCD TFT 5.7”
  • Memory: CompactFlash memory card, up to 4 GB
  • Visualization of measurements in digital form, analog indicators, diagrams, bargraphs
  • Ethernet, Webserver, FTP server, Modbus Slave TCP/IP
  • Diversified users’ access rights
  • PC software
  • Protection class: IP65 (front)
  • Operating temperature: 0...55 °C
  • Supply: 230 VAC
  • Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
  • Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
  • 2000 VAC galvanic isolation
  • High accuracy
  • EMC compliance - CE symbol
  • Mounting on DIN rail - EN-50022 complience
  • Supply voltage: 10...30 VDC
  • Ambient temperature: -10...+60°C

The P17 transducer, supplied from a current loop, converts the signal from temperature sensors or a standard voltage signal into a 4...20 mA current.

  • Modbus Slave over RS-485
  • Modbus RTU / Modbus ASCII protocols
  • Communication parameters configurable by dip-switches
  • Watch-dog alarm
  • Remotely configurable
  • 3-way galvanic isolation (1500 VAC)
  • High accuracy
  • Mounting on DIN rail - EN-50022 compliance
  • Ethernet 10/100 Base-T interface
  • Modbus TCP server
  • Webserver for configuration of device and representation of actual input values
  • Galvanic isolation on all the ways (1500 VAC)
  • Remotely configured
  • LED indication
  • EMC compliance
  • DIN rail mounting

Tempmate-S1 data loggers are specially designed for temperature monitoring in any cold chain logistics. The automatically created PDF and CSV report, containing detailed information such as data curve, every single measurement as a table and statistical information.

29.89 € Ex Tax: 24.70 €

Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.

  • Temperature measurement range*: -200…+100 °C
  • Relative humidity measurement range*: 0…100 %
  • Ambient light measurement range*: 0…10000 lx
  • Local storage capacity*: 24200 values for Temperature, Humidity and Light
  • Shelf-Life:
    • Lithium Battery devices: 12 months (possibility to charge)
    • Non-Lithium Battery devices: 6 months (possibility to charge)
  • External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
  • Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
  • Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
  • Recording Duration:
    • Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
    • Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
  • Certifications: CE, EN12830, EMC, RoHS, FCC
  • Connectivity: LTE 4G cat 1 with 2G Fallback
  • Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
  • Location: LBS - GSM Localization
  • Recommended Storage Temperature: -15…+25 °C
  • Flexible spears for grain temperature measurement
  • Rigid construction
  • Diameter: Ø8 mm
  • Penetration depth: up to 12 m
  • Digital temperature sensor
  • Measurements are done using PC software or handheld reader GW-200
  • Temperature spears and cables can be integrated into single system
  • Measures ambient temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+80 °C, 0...100 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures ambient temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+105 °C, 0...100 %RH
  • External sensor cable length: 1 / 2 / 4 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30 for device, IP40 for sensor
  • Calibration certificate included
  • Measures ambient air temperature and humidity
  • Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time
  • Temperature measurement range (depends on probe type): -30...+80 °C / -50...+125 °C / 0...+50 °C
  • Humidity measurement range: 0...100 %
  • 4 channels: 4 x external temperature probes or 4 x external temperature and humidity probes
  • Output: Ethernet
  • Measurement interval: 2 s
  • Communication protocols: WWW, Modbus TCP, SNMPv1, SOAP, XML
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Included calibration certificate
  • Supply: 5 VDC
  • Protection class: IP30

Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.

 

  • Integrated temperature and humidity sensor
  • Calculated values – dew point temperature, absolute humidity
  • Minimal and maximal value memory
  • Isolated RS-485 port
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)
  • Selectable double set point
  • Selectable TC / Pt100 input (order option)
  • Output: relay (control or alarm) and SSR (control)
  • PID control
  • Self-tuning feature
  • Soft-start function
  • Offset feature for input
  • Heating/cooling control
  • Manual control feature
  • Two set points
  • Input: TC (J, K, T, R, S) / RTD (Pt100)
  • Control output: relay or SSR
  • Auxiliary output: relay
  • PID / ON-OFF control
  • Auto-Tuning / Self-Tuning
  • Alarm modes: deviation, absolute
  • Heating / cooling control
  • 4+4 digits high contrast LED display
  • Supply: 85…270V AC / DC
  • Ambient temperature: 0…50 °C
  • Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
  • TR-040 (external setting): 0...40 °C
  • TR-040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Relay
  • Switching capacity: 24...250 VAC (16 A)
  • Ambient temperature: -35...65 °C
  • Protection class: IP65
  • TR series indoor thermostat with two temperature settings.TR-04040 (external setting)
  • TR-04040 (external setting): 0...40 °C/0...40 °C
  • TR-04040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Switch
  • Switching voltage / current: 24...250 V, 16 A AC
  • Ambient temperature: -35...65 °C 
  • Protection class: IP65
  • Temperature measurement range: -90...+260 °C
  • Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -30...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP67
  • Warranty: 3 years
  • Inputs: 4 x Pt1000
  • Temperature measurement range: -90...+260 °C
  • Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+60 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP67
  • Warranty: 3 years
  • Input: 4x external Pt100 sensors
  • Measuring range: -200…+260 °C
  • Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
  • Resolution: 0,1 °C
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: adjustable 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP20
  • Warranty: 3 years
  • Inputs: 4x external sensors + 1x internal temperature sensor
  • 3x Thermocouple type B, J, N, S, T external temperature sensor
    • Measuring range: according to the connected thermocouple
    • Accuracy: ± 0,4 °C
    • Resolution: 0,1 °C
  • 1x PT1000 external temperature sensor
    • Measurement range: -200...+260 °C
    • Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
    • Resolution: 0,1°C
  • Internal temperature sensor
    • Measuring range: -30…+70 °C
    • Accuracy: ± 0,4 °C
    • Resolution: 0,1 °C
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: adjustable 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP20
  • Warranty: 3 years