- For continuous level measurement of diesel in trucks, building machines, locomotives, etc.
- Output: 4...20 mA / 0...10 V / CAN
- Direct mounting into a tank through the 5-hole flange or G1” thread
- Arbitrary electrode length (up to 1 m)
- Setting by means of magnetic pen
- Ambient temperature: 9...30 VDC / 12...30 VDC / 9...30 VDC
- Protection class: IP68
- CLM-70 for continuous level measurement of liquids, bulk solids in all industrial branches
- Stainless steel design suitable for the food and pharmaceutical industries
- Output: 4...20 mA with two-way HART
- Process connection: G1”, G1 ½”, NPT 1" threads and Tri-Clamp (Ø 50.5 or 64 mm)
- Arbitrary electrode length (up to 20 m)
- Display of measured values on matrix OLED or LCD display
- Power supply: 18…36 V DC
- Protection class: IP67
- For continuous level measurement of liquid and bulk-solid materials
- Output: 4...20 mA / 0...10 V
- Universal usage, direct mounting into tanks, vessels, sumps or silos and hoppers
- Setting using a magnetic pen
- Possibility of linear measurement even in non-conductive or variously shaped vessels
- LED indication
- Versions with coated electrodes for aggressive or electrically conductive media
- Versions for explosive areas
- Ambient temperature: -40...85 °C
- Supply: 9...34 VDC / 12...34 VDC
- Protection class: IP67 / IP68
- Universal use for limit level sensing of liquids and bulk solids
- Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
- Output: NPN, PNP, NAMUR (for explosive areas)
- Sensitivity and hysteresis fluently adjustable
- Process coupling: thread M27x2; M30x1.5; G3/4“ or Triclamp
- Indication by LED
- Versions for explosive and flammable areas
- Supply: 7…36 VDC
- Protection class: IP67
- Universal use for limit level sensing of liquids and bulk solids.
- Direct mounting into tanks, vessels, sumps and tubes or silos and hoppers
- Output: NPN, PNP
- Setting using a magnetic pen
- High stability upon high sensitivity (possible to use for materials with εr ≥ 1.3)
- Indication by two LEDs
- Versions for explosive areas
- Supply: 8…9 VDC
- Protection class: IP67 / IP68
- Electrode level sensor AUREGIS LJ-B for level measurement
- Process temperature: From -30 to 180°C
- Electrode level sensor AUREGIS LJ-DSH-2R, LJ-DSH-3R for level measurement
- LJ-DSH-2R - 2 electrode level sensor; LJ-DSH-3R - 3 electrode level sensor
- Process temperature: -20...+80 °C
Electrode level sensor AUREGIS LJ-E3 with 3 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-E5 with 5 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-EB for liquids level measurement. By request sensor can be made with 2 to 5 electrodes with different lengths.
- Electrodes: Stainless steel DIN 1.4301 (AISI 304)
- Insulator: Teflon
- Electrode extension: Stainless steel DIN 1.4301 (AISI 304)
- Process connection: Stainless steel DIN 1.4301 (AISI 304)
- Connection head: Aluminum alloy
- Electrode length: Standard – 1000 mm or by request
- Process connection: R1 1/2“
- Process temperature: -30...+180 °C
Fluid level electrode probes SKC-201, designed to control conductive fluid level in open and pressure tanks. Electrodes – rod or flexible (rope with plastic coating). Probe head is made of acid-resistant steel. Maximal electrode count – 3. Insulation is made out of high quality plastic, enabling the probe to be used in food industry. Standard version probes are coated with plastic (FEP, PU, PVDF), lowering the residue collection (slime, carbonate, foam, etc.). Two modifications are available – with connection cable (P) and connector (G).
Fluid level electrode probes SKC-101, designed to control conductive fluid level in high temperature and high pressure medium. Modifications differ by permissible operating temperature. Recommended to use with Elcluwo 112...114 level alarms.
Interior protection from flooding sensor CZP-103R, designed for protection of various rooms (workshops, servers, communication modules, etc.) against flooding. The sensor activates when there is water between its electrodes. Can be used in drainages and rainfall wells for protection against basement flooding. LED indication.
- Flood protection
- Alarm and control
- Supply 12...24 VDC
- Isolated ~5 V electrode supply
- Low energy consumption
- Size 19 mm x 66 mm