This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Calibrators

Calibrators
Show:
Sort By:

Precise AC/DC current, voltage and resistance calibrator Inmel 7000.

The VA702 is a Volt/mA/TC Calibrator, designed as a source and measurement tool. It measures or outputs a 0 to 24 mA DC current loop, 0 to 20 V DC voltage, and supports thermocouple temperature measurements (model dependent). Note: The calibrator cannot measure and source simultaneously.

  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: -10℃ to 50℃
  • Operating altitude: Up to 2000 meters
  • Temperature coefficient: ±0.01% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
    • 35% up to 55℃
  • Power requirements: 6 x AAA batteries
  • Size: 204mm (L) x 99mm (W) x 46mm (H)
  • Weight: 460g (including battery)

The VA700 Loop Calibrator is a versatile source and measurement tool. It is designed to measure or output a 0 to 24 mA DC current loop and 0 to 20 V DC voltage. The calibrator cannot measure and source simultaneously.

  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: -10℃ to 55℃
  • Operating altitude: Up to 3000 meters
  • Temperature coefficient: ±0.005% of range per ℃ (for temperatures -10℃ to 18℃ and 28℃ to 55℃)
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
    • 35% up to 55℃
  • Shock: Random 2g, 5Hz to 500Hz
  • Safety: 1 meter drop test
  • Power requirements: 6 x AAA batteries
  • Size: 204mm (L) x 99mm (W) x 46mm (H)
  • Weight: 460g (including battery)

The VA710 Thermocouple Calibrator is a high-accuracy handheld instrument for calibrating thermocouple instruments. It measures or simulates 8 types of thermocouples (°C or °F) and millivolts. It cannot measure and source simultaneously.

  • Measure or simulate: Millivolt and 8 types of thermocouples (°C or °F)
  • Display: Large 5-digit LCD with full-angle visibility
  • Accuracy: Max. up to 0.3℃ and 0.025% for mV
  • Maximum voltage: 30V (between any jack and earth ground or between any two jacks)
  • Temperature coefficient: ±0.02%/℃ (from 0℃ to 18℃ and 28℃ to 50℃)
  • Storage temperature: -40℃ to 60℃
  • Operating temperature: 0℃ to 50℃
  • Operating altitude: Up to 3000 meters
  • Relative humidity:
    • 95% up to 30℃
    • 75% up to 40℃
    • 45% up to 50℃
  • Shock: Random 2g, 5Hz to 500Hz
  • Safety: 1 meter drop test
  • Fuse: F 0.125A/250V
  • Power supply: 6 x AAA 1.5V batteries or Standard jack for external power supply
  • Size: 205mm (L) x 98mm (W) x 46mm (H)
  • Weight: 472g (including battery)
  • Voltage range: 0,2...1000 V
  • Current range: 20 mA...20 A
  • Frequency range: 40...5000 Hz
  • DC voltage and currency accuracy: 0,02 %
  • AC voltage and currency accuracy: 0,05 %
  • Load capacity up to 40 VA
  • USB, RS232 interfaces
  • Ambient temperature: 23 °C ±5 °C

Portable calibrator for DC voltage and current.

 

Purpose:

  • Calibration and verification of temperature measurement equipment
  • Measurement and control equipment monitoring
  • Current loop circuit monitoring

Portable calibrator for tuning of thermoelectrical sensors.

 

Purpose:

  • Calibration and verification of temperature measurement equipment
  • Calibration and verification of transducers
  • Tuning of measurement and control systems

Portable calibrator for RTD sensors.

 

Purpose:

  • Calibration and verification of temperature measurement equipment
  • Measurement and transducer calibration and verification
  • Control system tuning
Portable temperature calibrator for dry air Pyros 650. These innovative calibrators have been designed for on-site applications and for the severe conditions of the naval and marine sectors. Their ease of use, compact and practical design make them unbeatable in industrial processes where the verification of the temperature measurement systems is a key issue for the control of the process and the quality of the final product. Special attention was paid to reduce the weight, to the small size and sound design obtained by using an aluminum body and aluminum and stainless steel for m..