This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • Thermocouple with small measurement tip TJ-K for temperature measurements from -75 °C to +250 °C, fast measurement
  • Sensor type: thermocouple K (NiCr-NiAl), class 2
  • Measurement range: -75 °C to +250 °C
  • Connection: mini connector
  • Multipoint float level switches AUREGIS LJ-VD for fluid level measurement and control
  • Multipoint level switch LJ-VD main difference from LJ-V is that LJ-VD uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Multipoint float level switches LJ-VDT for fluid level measurement and control
  • Multipoint level switch LJ-VDT main difference from LJ-VT is that LJ-VDT uses up to 3 floats instead of one, that ensures control and measuring in more than one level
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Multipoint temperature sensor AUREGIS TJ-D is designed for temperature measurement in different levels of measured environment
  • Temperature sensors can be put in one casing or in separate casings
  • When they are put in separate casings, measurement points can be spread in various places vertically and horizontally

Multifunctional professional current cramps NC12 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, frequency, temperature (with Pt100 and Pt1000 sensors), electric resistance and capacitance. Twistable clamp direction enables user to measure current in hard-reachable areas. Two variants are available: NC12-300A (up to 300 A AC) and NC12-1000A (up to 1000 A AC).

Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).

  • 4 analog inputs (standard signals, RTD, thermocouple)
  • RS-485 Modbus output (Slave mode)
  • 2 alarm outputs
  • Galvanic isolation of inputs (2 from other 2)
  • Programmable individual characteristics, mathematical functions
  • Programmable time counters
  • Rail-mounted
  • Temperature measurement range: -20...+60 °C
  • Humidity measurement range: 0...100 %RH
  • Pressure measurement range: 600...1100 hPa
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensors
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years

Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.

  • Fully functional data logger
  • Two-line digital LCD display
  • 4 control buttons
  • 32 alarm LEDs

System of data logging MS6D, MS6R (Comet System, Czech Republic). For mounting to 19" rack - one rack unit 1U. The device can be integrated into the MP033, MP034 waterproof housing. With backlight display, 4 control buttons (for configuration), 32 LED for alarm. 

  • Universal datalogger with 4 hardware MiniDIN inputs for connecting temperature and humidity probes.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 hardware MiniDIN inputs for thermocouples K, J, S, B, T, N.
  • Cold junction compensation (CJC).
  • Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Thermocouples are ordered separately.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 hardware MiniDIN inputs, 2 for thermocouples K, J, S, B, T, N and 2 for connecting temperature and humidity probes.
  • Cold junction compensation (CJC).
  • Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.

Data logger PD22. The device is designed for usage in telemetric systems, to be located between a controller and slave devices. PD22 increases the data transfer speed and enables the system to contain more devices. Slave devices are connected to the RS-485 port (Port.1, MODBUS). System controller is connected to RS-485 or RS-232 (Port.2). Data logger has a real time clock and is mounted on 35 mm rail.

  • Temperature measurement range: -20...+60 °C
  • Humidity measurement range: 0...100 %RH
  • CO2 concentration measurement range: 0...5000 ppm
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Internal sensors
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+60 °C
  • Supply: 5200 mAh LiIon battery
  • Protection class: IP20
  • Warranty: 3 years
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Stem length 700 mm
  • Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
  • Display with two periodically changed shown values (can be switched off)
  • Integrated sensors
  • Calibration certificate is included
  • Programmable output
  • Low temperature inertia
  • For use in non-aggressive environment
  • 3 year warranty
  • To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
  • Free software for configuration and data visualization
  • Bluetooth communication for smartphones and tablets (Android and IOS)
  • Safety lock magnetic mounting with inviolability system holder (accessories)
  • Compatible with food industry environment
  • Up to 4 recordable parameters simultaneously
  • Optional calibration certificate
  • Data visualization in WWW server
  • Convenient login from various devices (PC, tablet, phone)
  • Readout of up to 2500 values of slave devices (up to 100 devices, 25 registers each)
  • 1 GB Flash memory
  • E-mail messages in case of alarm occurrence
  • 2 alarm outputs or 2 binary inputs
  • RS-232, RS-485, USB, Ethernet, RTC
  • 6-range lighting meter AHKF
  • Supply: 15...36 VDC (24 VAC for AHKF-U too)
  • Sensor: Photodiode in glass casing
  • Ranges: 0...500 Lux / 1 kLux / 2 kLux / 5 kLux / 20 kLux / 60 kLux
  • Output: 4...20 mA / 0...10 V
  • Ambient temperature: -35...70 °C
  • Accuracy: < ±10 %
  • Temperature accuracy: < ±5 %
  • Size: 72 x 64 x 37,8 mm
  • Protection type: III (EN 60730)
  • Protection class: IP 65 (EN 60529)

The barrel heater is designed to be used for heating the fluids and oil products stored in barrels. Heater is typically used with thermostat (30-110 °C), thermal cut-off (160 °C), cable (3 m) and plug for connection to an earth contact.

  • Deactivation of the control system in the case of excessive temperature, or in the case of sensor error
  • Universal input for thermocouples and resistance thermometers
  • Relay output for disconnecting the temperature control system
  • Supply: 230 VAC
  • Operating temperature: 0...50 °C

Cartridge electric heating elements are designed to emit large amount of heat in a small area. The heaters are made from heat-resistant steel or brass, with kanthal wire embedded in ceramics and supplemented with magnesium oxide (MgO).

Pneumatic valve 290 (Asco).

  • Great permeability due to angular construction
  • Does not produce hydraulic shocks
  • Can operate in vacuum (up to 10-2 mbar)
  • Reliable and lasting stem seal

Special versions and additional equipment:

  • Valve completely made out of stainless steel AISI 3156L
  • Valve with welded ends or ISO 2852 connection for food industry
  • Back contacts, process limiters
  • Solenoid distributors
  • Special versions for oxygen, Ex zone
  • Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
  • Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
  • Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC 
  • Float level switches AUREGIS LJ-V with an extension for level control
  • Operating temperature: -30...+130°C
  • Protection class: IP65 
  • Portable analyzer NP40 is designed for power network quality parameter analysis
  • Analyses voltage and current harmonics up to 51-st, THD
  • Real-time waveform display (4 voltage / 4 current)
  • Measurement of TRMS currents up to 3000 A (with standard sensor)
  • Half cycle RMS measurement (voltage and current)
  • Measurement in 1-phase and 3-phase systems (3- and 4-wire)
  • Voltage, current, harmonics, power, energy and other parameter measurement
  • Graphical representation of data in a waveform and vector diagram
  • Record of events: dips, swells, overvoltages
  • Built-in 8 GB memory card
  • Ethernet interface for remote monitoring
  • USB interface for data transfer
  • Color 5,6” TFT display, 320 x 240 px

LTC potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTC has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTM potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

Movement of up to 1000 mm. High resolution (0,01 mm). No additional parts such as gears are needed, because transducer construction enables the direct connection into mechanical system.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines

LTP potentiometric linear transducers are designed for usage in linear displacement, movement measurement and position detection.

The main difference from LTM transducers is that LTP has self-tuning mounting with two bearings with which the non-linear twist of up to ±30 ° is possible. Movement of up to 1000 mm.

 

Application:

  • Press Brake Machines
  • Marble Machines
  • Tension Control
  • Horizontal Band Saw Machines
  • Transfer Machines
  • Hydraulic Machines
  • Sheet Metal Working Machines
  • Bending Presses
  • Textile Machines
  • Transducer for AC current and voltage into DC signal (1 output)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Transducer for DC current and voltage into other DC signal (2 outputs)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
  • Input is isolated from input and supply
  • Has fixed inputs and outputs – non-programmable
  • PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
  • This enables to increase device number in the system and extend its range
  • Long-life MOS or electrochemical gas sensor
  • Range 0....1000 ppm NH3
  • Resolution 1 ppm NH3
  • Outputs 4...20 mA / 0...10 V, RS-485
  • Suitable for thick and viscous media
  • Different materials for optimum media compatibility
  • EMC protection class is IEC 61000 (lightning, electrical discharge)
  • Range: 0...0,1 bar to 0...6 bar
  • Accuracy: +/- 0.3 %
  • Output: 4...20 mA
  • Ambient temperature: -25°C...+70 °C
  • Process temperature: -25°C...+70 °C
  • Supply: 9...32 VDC
  • Protection class: IP68
  • Material: Stainless steel (1.4404 (316L) / 1.4462 (318LN))
  • Sensor technology: Thick film on ceramic
  • Sensor material: Ceramics, Al2O3 96%
  • Cable insulation: PUR / Radox / PE

Pressure transmitter CMP 8270 with CANopen output is designed for pressure measurement from 0...1 bar to 0...600 bar. Medium accuracy, small size, high temperature- and strong vibration-resistant.

  • Output: CANopen, protocol DS301 / DS404 
  • Range: from 0...1 bar to 0...600 bar 
  • Accuracy: ±0,2%
  • Process connection: G¼ 
  • Supply: 8...32 VDC
  • Temperature: -50...135ºC
  • Ambient temperature: -40...125ºC
  • Sensor material: stainless steel (1.4542)
  • Protection class: IP67
  • Pressure transmitter for shipbuilding, engine manufacturing
  • Measured pressure from 0...1 bar to 0...250 bar
  • Technology: thick film on ceramic
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %
  • Operating temperature: -25...+125 °C
  • Ambient temperature: -25...+125 °C
  • Conformity: DNV, GL, KRS, RINA
  • Protection class: min. IP68

Pressure transmitter EPN/EPNCR 8298 is suited for ship industry (up to 2500 bar). Totally enclosed, stainless steel sensor system. Long-term reliability and stability, resistance to mechanical factors.

  • Range: nuo 0...2,5 iki 0...2500 bar
  • Accuracy: ± 0,3%
  • Output: 4...20mA / 0.5...4.5V DC
  • Process connection: G1/4“, R1/4“, G1/2“, M14x1.5, M18x1.5
  • Process temperature: -40°C...+125°C
  • Supply: 9...32 VDC / 5 VDC ±0.25 VDC
  • Protection class: IP67
  • Sensor material: nerūdijantis plienas 1.4548 (AISI630)     
  • Certification: GL, ABS, BV, DNV, RINA, LRS, KRS, NKK, RMRS
  • Pressure transmitter is suited for ship industry, has extended temperature range and increased accuracy, M12 connection and IP67 protection class
  • Small size
  • Totally enclosed, stainless steel sensor system
  • Long-term reliability and stability, resistance to mechanical factors
  • Range: from 0...2,5 to 0...700 bar
  • Accuracy: ± 0,2%
  • Output: 4...20 mA
  • Process connection: G1/4" m; G1/4" m (Manometer EN 837); G1/8" a, DIN3852-E; 1/4"NPT m; M10x1 m
  • Process temperature: -25°C...+125°C
  • Ambient temperature: -40°C...+125°C
  • Supply: 9...32 VDC
  • Protection class: IP67
  • Sensor material: Stainless steel (1.4542)
  • Certification: ABS, BV, DNV, GL, KRS, LRS, RINA, for shipbuilding
  • Pressure transmitter for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measured pressure from 0...2,5 bar to 0...250 bar
  • Technology: thick film on steel
  • Output signal: 4...20 mA
  • Accuracy: 0,5 %, 0,3 %
  • Operating temperature: -40...+100 °C
  • Ambient temperature: -40...+100 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS
  • Increased vibration resistance
  • Totally enclosed, stainless steel sensor system
  • Long-term reliability and stability, resistance to mechanical factors
  • Measurement range: from 0…2 to 0…2.5 bar
  • Accuracy: 0,15...0,8 % (at 25 °C
  • Output: 4...20 mA, 0...5 V, 0...10 V
  • Process connection: G1/4 (optional G1/2 with additional adapter), 1/4” NPT
  • Process temperature: -40°C...+125 °C
  • Ambient temperature: -40°C...+125 °C
  • Supply: 9/15...32 VDC
  • Protection class: IP65 / IP67
  • Sensor material: stainless steel (1.4542)
  • To measure air and neutral gases pressure in range -10 000...10 000 Pa
  • Configuration with switches or software: measuring ranges, units, outputs settings
  • Housing with simplified mounting system
  • Optional with display or without display
  • Range: -10 000...10 000 Pa
  • Accuracy: ± 1.5 % of reading ± 3 mmH2O
  • Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
  • Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
  • Response time: 0.3 s
  • Output (Optional):0-10 V ir 4-20 mA; 4-20 mA
  • Overpressure tolerated: 69 000 Pa
  • Conditions of use: 0…+50 °C. In non-condensing condition
  • Communication to PC: USB-mini DIN cable
  • Protection: IP65
  • Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC

Power network transducer P41 is designed to convert 1-phase power network parameters into analog or digital signal. Measured parameters: voltage (U), current (I), frequency (f), active power (P), reactive power (Q), apparent power (S), power factor (PF), reactive power coefficient (tgφ), phase angle difference (φ), active energy (Ep), reactive energy (Eq).

  • universal inputs (1 A or 5 A, 100 V or 400 V)
  • programmable analog output ( -20 mA...+20 mA)
  • parameter transfer via RS-485 interface (Modbus RTU protocol)
  • chosen values memory (9000 records)
  • programmable current and voltage transformer coefficients
  • transducer settings are changed via „LPConfig“ software (USB)

Power network transducer P43 is designed to measure 3-phase (three or four-wire systems) power network parameters. Two parameter values are converted into analog output signal -20...+20 mA. Other parameter values are sent over RS-485 or USB ports. All parameter min and max values are measured. Data refresh interval is less than 1 s. Output signals are isolated from input and supply. Two programmable alarm outputs. Pulse (passive) output OC can be used for energy accounting. Mounted on 35 mm rail.

  • Measuring ranges:
    • current 1/5 A L1...L3: 0,02...6 A
    • voltage L-N/L-L: 2,9...276/ 10...480 V
    • frequency: 45,00...66 Hz
    • active power: -1,65 kW...1,4 W...1,65 kW
    • reactive power: -1,65 kvar...1,4 var...1,65 kvar
    • apparent power: 1,4 VA...1,65 kVA
    • power factor: -1...0...1
    • active energy: 0...99 999 999,9 kWh
    • sum energy: 0...99 999 999,9 kvarh
  • Consumed power: ≤ 6 VA
  • Transformation coefficients: Ku = 1...4000, Ki = 1...10000
  • Supply: 85...253 VDC or AC 40...400 Hz
  • Ambient temperature: -10...23...+55 °C

Преобразователь питаемый от токовой петли P17.

Loading...