This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • FX-2000 is designed for moisture measurement of hay, straw, windrow and bales
  • Moisture measurement range: 6...40 %
  • Bright, clear digital display
  • Can be used for on-the-go moisture monitoring or as a portable meter
  • In continuous mode:
    • Takes two readings every second
    • Displays the average and highest of eight accumulated readings
    • Readings updated every 4 seconds
    • Built-in backlight
    • Connects to tractor power supply
  • In portable mode:
    • Averages up to 100 accumulated readings
    • Displays average and highest of accumulated readings
  • Built-in calibration check
  • Audible, adjustable alarm
  • Operating temperature: 0...50 °C
  • Size: 200 x 80 x 40 mm
  • Weight: 285 g
  • Rugged construction ensures years of reliable use
  • Optional sturdy plastic carrying case
  • Supply: 9 V battery
  • 3-year warranty

The oxygen concentration meter MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 °C.

  • Panel electromagnetic devices are designed to measure the angle between phase voltage and current in one-phase and three-phase circuits
  • Measured value is represented in cosine (cos φ)

Power meters PA39. Panel power meters are designed to measure active and reactive power. Transducer signal is measured using magnetoelectricity. Can be used for 1 or 3-phase measurement. Special version available for two-way energy flow measurement. Tropical version is also available (TIII).

  • Voltage range: 100 √3...690 V
  • Current range: 1A (X/1A) or 5A (X/5A)
  • Accuracy class: 1,5
  • Consumed power: = <3,25 VA
  • Protection class: Frnt panel IP52, terminal IP00
  • Devices comform with EN61000-6-2, EN-61000-6-4 standards
  • Temperature range: -10...23...+55 °C
  • Input (single option): 100 V, 250 V, 400 V, 1 A, 5 A, 20...500 Hz
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40/60 VAC/VDC
  • Protection class: IP65
  • Input (single option): 0...100 V, ±100 V, 0...400 V, ±400 V
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65
  • Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
  • Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
  • Current measurement range: 0/4...20 mA; ±20 mA (DC)
  • Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Auxiliary 24 VDC output to supply transducers
  • Display: 3-color LED, 5-digit
  • Temperature compensation
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65
  • Digital, programmable power network parameter meter N30P with RS-485 interface
  • Measures voltage, current, frequency, active, reactive power, cosφ, tgφ, energy consumption
  • Programmable with keys or via computer
  • Power network parameter meter N14 is designed for measuring of three-phase network parameters and accounting of internal energy consumption. Can be used in 3- or 4-wire systems
  • Can be used in energetic monitoring systems (RS-485 port)
  • Active and reactive power measurement, active and reactive power counters, average power measurement
  • Phase, current and voltage effective value measurement
  • Network frequency measurement
  • Average active power (over set time) measurement
  • Changeable current and voltage transformer transfer coefficient values
  • Operating temperature: -30...+50 °C
  • Programmable switch output and RS-485 (MODBUS) port
  • Pulse output for remote energy accounting
  • Accuracy class: current, voltage 0,5/1,0; frequency 1,0; power 2,0; energy 1,0/2,0; tg φ 1,5
  • Designed for direct or indirect measurement of 1-phase network parameters
  • Measured values: U, I, f, P, Q, S, PF, tg fi, fi, Ep, Eq
  • Direct measurements up to 63 A
  • Universal input: 1/5 A 100/400 VAC or 32/63 A, 100/400 VAC
  • Outputs: RS-485 (MODBUS interface), 1x relay + 1x analog or 2x relay
  • OLED display
  • Programmable current and voltage transformer ratios
  • Programmable via buttons or free eCon software (through USB)
  • Size: 53 x 110 x 60 mm
  • Measures power network parameters in 3-phase network 3 or 4-wire symmetrical or asymmetrical systems
  • THD factor
  • Outputs: 3 relays and 1 analog output (ND10), 1 relay and 3 analog outputs (+/-) (ND10A)
  • Digital output: RS-485 MODBUS (option)
  • Protection class for front side: IP65
  • Supply: 85...253 VDC/VAC
  • Backlit LCD display
  • Dimensions: 96 x 96 x 77 mm
  • Power network meter ND20 is designed to measure 3-phase network parameters and to account internal energy consumption
  • Usable in 3- and 4-wire systems
  • Can be used in energetic monitoring systems (RS-485 port)
  • Front panel protection class IP65
  • Harmonic, THD, watthour measurement
  • 3,5” LCD indicator
  • Analog output of 0/4...20 mA (additionally ordered)
  • Measurement of power network parameters in 1-phase and 3-phase (3 or 4-wire) systems
  • Current inputs 0,1 A and 0,25 A (for dedicated transformers)
  • Quick and convenient ways to connect current transformers via RJ12 connector or screw terminals
  • Designed for usage with following transformers: LJ12, LJ25, LJ35, LJ45, LJ306, LJ307, LJ308
  • RS-485 (MODBUS RTU) interface
  • THD factor measurement
  • Backlighted LCD 3,5”
  • Protection grade from the frontal side: IP65
  • Power network parameter measurement in 1- and 3-phase network
  • THD factor calculation
  • High accuracy class
  • Backlit LCD 3,5” display
  • RS-485 Modbus slave interface
  • Frontal protection class: IP65
  • Measures 54 power network parameters (up to 63-rd harmonic, in 1- and 3-phase network)
  • Color LCD TFT 3,5” display
  • Display pages are fully configurable by user (10 pages. 8 parameters in each)
  • 2 configurable alarm outputs
  • Digital RS-485 Modbus output
  • Optional: 0/4...20 mA output and 2xPt100 inputs
  • Option: logging of 32 parameters into internal 8 GB memory
  • Modbus TCP/IP, HTTP, FTP server, WWW server, DHCP client
  • SF6 gas density monitor for high voltage switchgear
  • Three versions: 1 / 2 / 3 stages (8781 / 8782 / 8783)
  • Measurement range: 0...1,1 MPa (mechanical), 0...0,85 MPa (electronic)
  • Output signal: floating change-over contact (SPDT) / 6.5...20 mA current loop
  • Switch point: factory calibrated
  • Media temperature: -40...+80 °C
  • Ambient temperature: -40...+80 °C
  • Protection class: IP65
  • Measurement range of external sensor: -200...+600 °C
  • Operating temperature: -30...+80 °C
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Communication protocol: WWW, ModbusTCP, SNMPv1, SOAP, XML
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Temperature indicator TI-N20, TI-N24 for temperature measurement from -30 to +800 °C
  • Various temperature sensor construction types are available
  • Temperature indicator TI-N20/5, TI-N24/5 for temperature indication
  • Various temperature sensor constructions are available: Pt100, Pt1000; NTC, PTC, termopora K, J
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases

Digital programmable indicator N20 for temperature, DC voltage and current measurement. Measures J, K, Pt100 temperature sensors’ signals.

 

Programmable parameters:

  • LED indicator color, which changes depending on input signal value: green, yellow and red
  • Value limits
  • Measurement unit indication
  • Cold junction compensation (CJC)
  • Compensation for Pt100 sensors
  • Averaging time
  • Individual characteristic
  • 2 OC alarms in 6 modes
  • Carbon dioxide (CO2) range: 0… 2000 ppm or 0…4000 ppm (selectable)
  • Stable long-life optical NDIR sensor
  • Response time: < 2 min
  • Output: 0...10 V arba 4...20 mA
  • Ambient temperature: 0...+ 50 ºC
  • Supply: 24 VAC/ VDC
  • Protection class: IP 30
  • Dimensions: 98 x 98 x 33 mm
  • Application: offices, hotels, convention centers, apartments, shops, etc.
  • Meter N27D is designed to measure parameters of the single-phase power network
  • Direct measurements up to 63 A
  • The device measures voltage, current, frequency and active power
  • Measurements are represented in 4-digit display
  • Button enables the scrolling through available measurements
  • Mounted on standard 35 mm rail (LST-EN 62208)
  • For galvanic separation of current signal between explosive (Ex) and normal areas
  • Input: 0...20 mA, 4...20 mA
  • Output: 0...20 mA, 4...20 mA, version with 0...10 V
  • Version with support for HART signal
  • DIN rail-mounted
  • Supply: 24 VDC / 230 VAC
  • Operating temperature: -20...60 °C
  • Protection class: IP20
  • Universal input (for standard signals and temperature sensors)
  • Alarm output
  • OLED display
  • Configuration via miniUSB connector
  • Supply: 24 VDC or 230 VDC / VAC
  • IP65 protection class

2, 3 or 4 axes ADR10 series indicators for digital systems, linear displacement measurements, movement measurements, positioning detection. These indicators are used with optical and magnetic linear encoder scales ALS or MLS. Error compensation.

 

Application:

  • Lathes
  • Milling machines
  • Plate metal processing mills
  • Grinding machines
  • Erosion machines
  • Mechanical processing centers
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø9,8 mm
  • Length: 1...35 m
  • Tensile strength: ≤ 2,5 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø17 mm
  • Length: 1...100 m
  • Tensile strength: ≤ 8 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C
  • The purpose of the test chamber is to measure the airtightness of doors which are in the frame of chamber at set pressure
  •  Air is driven into the chamber with a ventilator which is controlled by an AC drive
  • The intake flow rate is measured by CS Instruments VA420 flow rate meter (0-480 m3/4)
  • The pressure in chamber is measured with DPT series differential pressure transmitter
  • The temperature in chamber is measured in 11 points
  • All data is logged and visualized in logger and computer (via IGSS software)
  • Designed for the remote monitoring of measurements in industrial, domestic and environmental maintenance applications
  • Typical applications include oil separator alarms, tank surface level measurements, monitoring pumping stations and real estate, and surface and groundwater measurements
  • The device sends alarms and measurement results as text messages either directly to GSM phone or to the LabkoNet server
  • Settings can be easily modified with a GSM phone
  • Analog inputs: 4 units 4...20 mA (passive or active)
  • Digital inputs: 4 units
  • Relay outputs: 2 units
  • Communication: SMS, GPRS
  • Operating temperature: -20...+50 °C
  • Supply: 230 VAC / 12 VDC battery
  • Protection class: IP65
  • Thermocouple commutatotr TK with cold junction compensation for thermocouple measurement output (in turns) to one output
  • Connecting that output to measuring device or indicator enables the monitoring of thermocouples in turns
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from  -0,6...3,4 to 4...40 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C / -40...+125 °C
  • Ambient temperature: -25...+125 °C / -40...+125 °C
  • Protection: IP65
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: piston
  • Measured pressure from 1...10 to 40...400 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -25...+125 °C
  • Ambient temperature: -25...+85 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, EN60730-1 / EN60730-2-9: Typ 2.B.H
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: membrana
  • Measured pressure from 1...10 to 10...100 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: 0...+80 °C
  • Ambient temperature: 0...+80 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
  • Compact thermostat for shipbuilding
  • ISP version – with capillary tube, ISPT version – without capillary tube
  • Measured temperature from +5...95 °C to +20...150 °C
  • Switching differential: not adjustable
  • Output signal: floating change-over contact
  • Ambient temperature: -30...+70 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS, EN60730-1 / EN60730-2-9: Typ 2.B.H

Single-phase commutator – controller RP7. The device can be used or circuit commutations. Can be used for resistive and inductive loads and single-phase motor speed control. Possible control with standard analog signal.

 

Other functions:

  • Load current limiting
  • Soft start
  • Isolated inputs
  • Load current control
  • Fuse failure detection
  • Overload indication

Converter PD8 is designed for data transfer from devices with RS-485 port to Ethernet network. The device comes in two versions. First version is used with network service Real Port. In this case, the Master role is taken by PC with installed software, creating a parallel port. Software (i.e. Lumel Energy) ensures data transfer between devices with RS-485 port and one PC.

 

Second version (parallel bridge with UDP protocol) enables the sextension of data transfer system using additional PD8 converters and local Ethernet network. Variant with two converters or one with many (max. 65) converts is available.

Single-phase controller – commutator RP1. The device can be used or circuit commutations in heat element devices. Can be used for resistive and inductive loads. Possible control: pulse or standard (analog signal).

 

Other functions:

  • Load current limiting
  • Soft start
  • Initial load power setting
  • Control with an external signal
  • Load current control
  • Fuse failure detection
  • Overload indication
  • Master/slave output
  • Switch output

Linear encoder MLS210. With spiral connection.

 

Technical specifications

  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With cable connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With spiral connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS120.

Technical specifications

  • Casing integrated into slider
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS130. Very small size.

 

Technical specifications

  • Very small measuring head (in metal enclosure)
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection and slider joints.

 

Technical specifications

  • Protection class IP67
  • Twin sliders
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option

Loading...