Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)
  • Temperature transducer TJ-DIN AV, designed to convert temperature measurement signal into 4...20 mA, 0...10 V
  • Mounted on 35 mm DIN rail
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Current (AC / DC) transducer T23CT with 4...20 mA output
  • AC/DC current input (single option): up to 50 / 100 / 150 / 200 / 300 A
  • Optional mounting on DIN rail
  • Galvanic isolation
  • Supply: 24 VDC
  • Ambient temperature: -25...+55 °C
  • Protection class: IP65, IP40 for terminals
  • To measure carbon dioxide in air and neutral gases range 0…5000 ppm
  • Configuration with switches or software: measuring ranges, outputs settings
  • Optional with display or without display
  • Ambient and duct models. Duct model available only without display
  • To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
  • Configuration with keypad or software: measuring ranges, units, outputs settings
  • Optional with display or without display
  • Galvanic isolation all the ways
  • On request range increase up to 0...20 000 ppm
  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Long-life MOS sensor
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...2,5 % vol.) C2H2
  • Resolution 0,1 % LEL (25 ppm) C2H2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor

DPC 8380 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

DPS 8381 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.

  • Range: 0...2,5 iki 0...600 bar / 0...30 iki 0...7500 psi
  • Sensor type: Thick film on steel
  • Accuracy:  ±0,5 %
  • Output (chosen): 4...20 mA / 0...5 VDC / 0...10 VDC / 1...6 VDC
  • Switching outputs: 2 x PNP
  • Shown measuring units: bar, psi, MPa, kPa, m WC, mm WC
  • Ambient temperature: -25...+85 °C
  • Media temperature: -25...+85 °C
  • Protection class: IP65
  • Process connection: G1/4" m, R1/4" m, 1/4"NPT m, 1/2"NPT m
  • Data logger memory: 3518 points

The unit is designed for determining dielectric loss tangent and permittivity of transformer oils and other dielectric fluids according to the IEC 60247.

It is a fully automatic device that allows testing according to the procedures defined in these standards, as well as according to the user procedures specified in the appropriate section of the setup menu.

  • Applied measuring voltage: 500…2000 V a.c. sinusoidal
  • Tan δ measurement range: 0,00001…1
  • Tan δ measurement resolution: 1х10-5
  • Tan δ measurement accuracy: ± 1 % of measurement + 0,00008
  • Measurement range of relative dielectric constant ε: 1,0…15,0
  • Accuracy of ε measurement: ± 1 %
  • Oil temperature measurement range: 20…110 ᴼС
  • Measuring cell volume: 42 cm³
  • Power supply: 85...264 V a.c. (48…63 Hz)
The constant speed actuators of the XI type for modulating duty are of modular design. The basic module (driving unit) is a multi-turn unit that incorporates a three-phase electric motor 3x400 V, the main gear, a manual operation, a drive transmission system, a control block and an industrial-type connector. The multi-turn unit represents a self-contained multi-turn actuator but when combined with a linear unit or a lever (part-turn) gearbox it makes up a linear or a lever (part-turn) actuator. The modulating duty XI actuators may differ in design of their control blocks as the control panel m..
The constant speed type XS actuators for open-close duty are of modular design. The basic module (driving unit) is a multi-turn unit that incorporates a three-phase electric motor 3x400 V, the main gear, a manual operation, a drive transmission system, a control block and an industrial-type connector. The multi-turn unit represents a self-contained multi-turn actuator but when combined with a linear unit or lever (part-turn) gearbox it makes up a linear or a lever (part-turn) actuator. The XS and X-MATIK actuators for open-close duty differ one from another with a control block as that block i..
The constant speed type XS actuators for open-close duty are of modular design. The basic module (driving unit) is a multi-turn unit that incorporates a three-phase electric motor 3x400 V, the main gear, a manual operation, a drive transmission system, a control block and an industrial-type connector. The multi-turn unit represents a self-contained multi-turn actuator but when combined with a linear unit or lever (part-turn) gearbox it makes up a linear or a lever (part-turn) actuator. The XS and X-MATIK actuators for open-close duty differ one from another with a control block as that block i..
Zpua actuators with ATEX certification. Spindle                       Nominal rotation speed from 20 to 240 NmLinear                         Nominal force value from 10 to 60 kNLever                          Torque from..
  • The program is designed to represent and log measured values
  • Representation tools: bar graphs, graphs, numbers
  • Interfaces: RS-485 MODBUS RTU, ASCII, LUMBUS, MODBUS TCP/IP
  • Number of MODBUS devices that can be represented (1 device – 1 address): 5, 10, 30 and 100 (selected while ordering)
  • Data logging: tables and/or graphs in PC memory

Programmable pulse counter P30O, designed to convert frequency, pulse, input period, time and revolution speed signals into standard voltage or current signals. The device is programmed via PC (RS-485 interface) or with buttons.

 

Main properties:

  • 2 universal pulse inputs
  • Mathematical functions for every input
  • Individual output characteristic (up to 21 point)
  • Option – internal transducer supply source 24 VDC, 30 mA
  • RS-485 interface (protocols Modbus RTU Slave, Modbus TCP Slave)
  • Data logging function (internal 4 MB memory or SD/SDHC card (up to 8 GB))
  • Dedicated to following devices: N14, N27P, N30P, N43, N100, ND10, ND20, P41, P43
  • Monitors, archives, visualizes measured data, generates reports
  • Communication protocols: Modbus RTU, Modbus TCP
  • Reading interval: 1...60 s
  • Archiving interval: 1 s...1 h
  • License types: for up to 5 / 10 / 30 / 50 devices
  • Optional communication with other Modbus RTU/TCP devices
  • Multiple user access with varying levels of authorization
  • Remote access to PowerVis software through a web browser
  • Languages: English, German, French, Spanish and Polish
  • Silicone /  glass fiber coating
  • Thermostat 0-200º C
  • Glass fiber coating
  • Protection class IP54
  • Silicone insulation for heating element
  • Warm-up time of 24h (for 200 L water barrel from +15º C to +80º C  with 1200 W barrel heater)
  • Regulated fast-opening buckles
  • Barrel heating pads can be used simultaneously
  • Standard capacity 200 L
  • 3 meter connection cable
  • Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
  • Versions according to DIN 43763 and DIN 43772 (form 4)
  • Lengths: according to customer's specification
  • Bore diameters: Ø3.5 mm, Ø7 mm
  • Maximal process pressure and temperature depends on thermowell dimension and its material
  • Threads for thermometer: metric M14x1.5, M18x1.5
  • Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
  • Other materials, threads and dimensions
  • Radar level meter GRLM-70 for continuous level measurement in liquids, mush and bulk-solid materials
  • Outputs: 4...20 mA HART or RS-485 Modbus RTU
  • Measurement depth: up to 40 m
  • Universal usage, direct mounting into containers, silos, vessels, reservoirs, etc.
  • LCD or OLED screen
  • Linear measurement in non-conductive and in differently shaped containers
  • Versions with stainless steel rod or rope electrodes
  • Xi, Xit versions for usage in explosive areas
  • Xd, XdT versions for usage in flammable dusts areas
  • Supply: 18...30/33/36 VDC
  • Protection class: IP67
  • Designed to replace cable data transmission into aerial
  • Can be used in telemetric and information systems
  • Measurement channels: up to 24
  • Analog inputs: 12
  • Relay outputs: 6 or 32
  • Analog outputs: 4 or 8
  • Digital outputs: RS-232, RS-485, USB
  • Screen: touchscreen LCD TFT 5.7”
  • Memory: CompactFlash memory card, up to 4 GB
  • Visualization of measurements in digital form, analog indicators, diagrams, bargraphs
  • Ethernet, Webserver, FTP server, Modbus Slave TCP/IP
  • Diversified users’ access rights
  • PC software
  • Protection class: IP65 (front)
  • Operating temperature: 0...55 °C
  • Supply: 230 VAC
  • Digital data logger KD8 with a colored touchscreen LCD display
  • The device is designed for measurement and logging of parameters in industry, energy sector, control and monitoring systems
  • Software for data analysis in PC
  • 4-language menu, electronic signature for data protection

Regulator RE22 is designed to control furnace, dryer, cast machine and other devices’ temperature.

Temperature regulator RE72 for ladder control, designed for temperature stabilization in plastics and food industries.

 

  • Universal measurement input
  • Auxiliary measurement input 0/4...20 mA
  • Binary input
  • Ladder temperature control, 15 programs with 15 intervals
  • Soft start
  • ON/OFF, PID, PID step-by-step (step valve control) or PID heating – cooling
  • 8 alarm types, alarm control
  • Timer function
  • Front panel protection class IP65
  • Backside protection class IP20

Process regulator RE82 is designed for temperature stabilization in plastics and food industry.

Humidity and temperature regulator AR247 is designed for temperature and humidity control. The device is made with either integrated or cable-connected sensor. Protection class is IP65. Optionally can be ordered: RS-232 or RS-485 ports, analog output 0/4...20 mA or 0...10 VDC (for control or signal transmission).

  • Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
  • PID or ON/OFF control
  • Automatic selection of PID parameters
  • One relay output and one alarm relay
  • Manual control mode
  • One binary input
  • Operating temperature: 0...50 °C
  • Supply: 230 VAC
  • Protection class: front IP65, back IP20

Regulator RE55 is designed to control temperature in food and chemistry industry.

Temperature regulator RE71 is designed for fixed range and sensor. Input type is selected while ordering. Control: ON/OFF, PID, PID+Autotuning, Smart PID.

Temperature regulator RE81 for fixed range and sensor, with 2 switch or SSR outputs, designed for control in heating, conditioning systems. Function for 3-position control. Control: ON/OFF, PID, PID+Autotuning, Smart PID and 3-position. Input type selected when ordering.

Differential pressure switch EXPD 920/924/932. Technical specifications Range -1...18 bar Accuracy  ±2 % Output Switch Switching voltage, current 250 VDC, 0,25 A 250 VAC, 5 A 30 VDC, 5 A Ambient temperature -30...+65 °C Process temperature < 150 °C  Protection class IP65 Process connection ..
  • Used for controlling pumps in traditional boosting systems, with expansion tank
  • Possible ranges: 1,5...6 bar, 4...10 bar (programmable)
  • 1- or 3-phase
  • Mounting on pipe
  • Operating temperature: 0...50 °C
  • Supply: 117/230/400 VAC
  • Protection class: IP44
  • Compact pressure switch for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
  • Measuring principle: bellow
  • Measured pressure from -0,9...1,5 to 10...100 bar
  • Output signal: floating change-over contact (SPDT)
  • Switching differential: not adjustable
  • Media temperature: -40...+150 °C
  • Ambient temperature: -25...+70 °C
  • Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, RINA, EN60730-1 / EN60730-2-6: Typ 2.B.H
Pressure switch PSTD 9D0 for differential pressure measurement with variable differential. Technical specifications Range -1...8 bar Accuracy ±1% Output switch Switching voltage, current 250 VAC, 10 A 250 VDC, 0,1 A 220 VDC, 0,25 A 110 VDC, 0,5 A 24 VDC, 2 A Ambient temperature -25...85 °C Process temperature < 120 °C  Protec..
  • Meter to measurements electric quality parameters in 3 phase systems
  • Programmable display pages
  • 3 programmable alarm outputs and 1 pulse output
  • Digital transmission to the master system through the RS-485 interface
  • USB for configuration by using free eCon software

Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.

 

Technical specifications

  • One or more level control
  • Switch output 2A, 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)

Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.

 

Technical specifications

  • One or more level control
  • Switch outputs: switching + NO 2 A / 250 VAC
  • Probe supply from isolated ~12 V source
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • One or more level control
  • Switch outputs: switching + 3 x NO 2 A / 250 VAC
  • Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – flooding, drainage, dry flow, overflooding
  • Pump or valve control
  • Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
  • Mounting on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC
  • One or two level control
  • Switch outputs – switching + 5 x NO, 2A / 250 VAC
  • Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
  • Adjustable sensitivity
  • Available modes – filling, draining, dry flow, overflow, two/three pump control and others
  • Valve or gate control
  • Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
  • Mounted on standard rail (35 mm)
  • Supply: 230 VAC / 24 VAC
  • Measurement distance: 0,5…2 m
  • Accuracy: ± 0,5 °C
  • Measurement speed: 0,7…2 m
  • Software: DERMALOG Fever Detection (PC required)
  • Interface: USB 3.0
  • SDK: .Net / C / C++ / (Java coming soon)
  • Measurement speed: 0,6 s (up to 700 people per hour)
  • Integrated sensors: 5
  • IR thermal array, range: 0...100 °C (± 0,3 °C)
  • Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
  • Relative humidity sensor, range: 0...100 % (± 3 %)
  • Vibration sensor (for sabotage detection), range: 0,25...5 G
  • Distance sensor, resolution: 1 mm
  • Dew point calculation
  • Relay inputs: 2
  • Relay outputs: 2
  • LED indication, buzzer (85 dB)
  • Communication: Ethernet (10/100)
  • Connector (RJ45) for connection of other Kentix devices
  • Webserver
  • Software: remote connection with AlarmManager-PRO
  • E-mail, SNMP alarms, Rest API
  • SD card slot (to save pictures, card up to 128 GB)
  • PoE
  • Optional: RFID reader
  • Optional: wall bracket, cable
  • System consists of alarm device SET-1000 and fixed level vibration sensor SET/V
  • For usage separators, basins and tanks
  • Alarm device SET-1000 is a single-channel level switch
  • When used with SET/V, SET-1000 alarms when set high level in tank is exceeded
  • ATEX certified
  • Wall-mounted
  • Supply: 230 VAC, 50/60 Hz
  • The system is designed to monitor pressure and flow rate of medical gasses
  • Information is gathered from pressure and flow rate transmitters and conveyed into the controllers which transfer the data into a PC via RS-485 interface (MODBUS protocol)
  • SCADA software enables the visualization of the process
  • Data is logged annd represented on the computer screen
  • Values can also be represented in graphs