- 1-Wire protocol ambient pressure sensor TSP200
- Pressure measurement range: 300...1100 hPa
- Excellent long-term stability
- Warranty: 3 years
- Connection: RJ-11
- Maximal pressure measurement range: 0...1000/2000/5000/7000 Pa
- Air flow and velocity measurement
- Output: 0...10 V / 2...10 V or 4...20 mA
- Option: autozero function and LCD screen
- Allowed overpressure: 25 kPa
- Supply: 10...35 VDC
- Operating temperature: -40...+50°C (see datasheet)
- Protection class: IP54
- To measure air and neutral gases pressure in range -10 000...10 000 Pa
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -10 000...10 000 Pa
- Accuracy: ± 1.5 % of reading ± 3 mmH2O
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output (Optional):0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 69 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
- To measure air and neutral gases pressure in range -100...100 Pa
- Solenoid valve for auto-calibration: frequency 1…60 min
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -100...100 Pa
- Accuracy: ± 1 % of reading ± 2 Pa
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output: 0-10 V and 4-20 mA
- Overpressure tolerated: 21 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply: 24 V AC / V DC
- To measure air and neutral gases pressure in range -1000...1000 Pa
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -1000...1000 Pa
- Accuracy: ± 1.5 % of reading ± 3 Pa
- Resolution: 1 Pa; 0.1 mmH2O; 0.01 mbar; 0.01 inWG; 0.01 mmHG; 0.1 daPa; 0.001 kPa
- Measurement units: Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA: 4-20 mA
- Overpressure tolerated: 21 000 Pa
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
- To measure air and neutral gases pressure in range -2000...2000 mbar
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -2000...2000 mbar
- Accuracy: ± 1.5 % of reading ± 3 mbar
- Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
- Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 4100 mbar
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC: 16 / 30 V DC
- To measure air and neutral gases pressure in range -500...500 mbar
- Configuration with switches or software: measuring ranges, units, outputs settings
- Housing with simplified mounting system
- Optional with display or without display
- Range: -500...500 mbar
- Accuracy: ± 1.5 % of reading ± 3 mbar
- Resolution: 1 mbar; 0.1 inWG; 1 mmHG; 1 mmH2O; 1 hPa; 10 daPa; 0.1 kPa; 0.1 PSI
- Measurement units: mbar, inWG, mmHG, PSI, mmH2O, daPa, hPa, kPa
- Response time: 0.3 s
- Output (Optional): 0-10 V ir 4-20 mA; 4-20 mA
- Overpressure tolerated: 1400 mbar
- Conditions of use: 0…+50 °C. In non-condensing condition
- Communication to PC: USB-mini DIN cable
- Protection: IP65
- Power supply (Optional): 24 V AC / V DC; 16 / 30 V DC
- PID controller
- 2 set points (SP), chosen by binary input
- Pressure measurement range: -250...2500 Pa
- Output: 0...10 V
- Input: NTC10, NTC20, Pt1000, Ni1000
- LCD screen
- Temperature compensation
- Allowed overpressure: 25 kPa
- Supply: 24 VDC/VAC
- Operating temperature: -20...+50°C
- Protection class: IP54
- Maximal pressure measurement range: 0...2500 Pa
- 8 field selectable measurement ranges (via jumper)
- Output: 4...20 mA
- Option: LCD screen
- Allowed overpressure: 25 kPa
- Supply: 10...35 VDC
- Operating temperature: -10...+50°C
- Protection class: IP54
- Two pressure transmitters in one device
- Pressure measurement range: -250...2500 / -250...7000 Pa
- Option: DPT-DUAL-MOD-AHU – with air flow transmitter
- Output: Modbus RTU
- Allowed overpressure: 25 kPa
- Supply: 24 VDC/VAC
- Operating temperature: -20...+50°C
- Protection class: IP54
- Pressure measurement range: -250...2500 / -250...7000 Pa
- Input: 2 x 0...10 V, NTC10k, Pt1000, Ni1000, binary
- Output: Modbus RTU
- Temperature compensation in range of 0...50 °C
- Allowed overpressure: 25 kPa
- Supply: 24 VDC/VAC
- Operating temperature: -20...+50°C
- Protection class: IP54
- Pressure measurement range: from 0...1 bar to 0...6 bar
- Made to be used for air-conditioning, heating and water systems
- For neutral fluids and non-aggressive gases, compatible with refrigerants
- Output: 4...20 mA
- Supply: 24 VDC/VAC
- Operating temperature: -20...+80°C
- Protection class: IP65
- Input: differential pressure
- Typical areas of use are chemical industry and process engineering
- Measurement range: 75 mbar...70 bar
- Output: 4...20 mA HART
- Supply: 12...30 VDC
- Operating temperature: -40…+85 °C
- Protection class: IP65
- Process connection: 1/4-18NPT
- Pressure range: from 0...1 to 0...16 bar
- Output signal: 4 ... 20 mA (P1–P2)
- Process temperature: -25...+125 °C
- Process connection: G1/4" f
- Protection class: min. IP65
- PID controller
- Pressure measurement range: 0...2500 Pa / 0...7000 Pa
- Switchable between air flow and pressure measurement
- Output: 0...10 V / 4...20 mA
- Option: autozero function
- Allowed overpressure: 25 kPa
- Supply: 24 VDC
- Operating temperature: -20...+50°C
- Protection class: IP54
- PID controller
- Pressure measurement range: 0...2500 Pa
- Modbus RTU communication
- Control output: 0...10 V
- External input: 0...10 V / thermistor / binary
- LCD display
- Temperature compensation
- Allowed overpressure: 25 kPa
- Supply: 24 VDC
- Operating temperature: -20...+50°C
- Protection class: IP54
- Temperature measurement range: -35…+80 ºC
- Humidity measurement range: 0…100 % RH
- Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
- Output: Modbus RTU
- Allowed overpressure/ bellow: ± 50 kPa
- Operating temperature: 24 VAC / 15…35 VDC
- Protection class: IP 65
The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.
- Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
- Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Accuracy at 25°C typically: ± 0.5 % FS typ.
- Membrane in Duplex steel 1.4462
- Pressure connection: G1/2” male, flush membrane
- Media temperature –10... +125 °C
- Ambient temperature: –10...+125 °C
- Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
- Hydrogen pressure transmitter’s measuring principle: Thin-film-on-steel
- EC79 and ECER-134 certification pending (see product website for current situation)
- Applications: Fuel cells, fueling stations, hydrogen compressors, hydrogen tanks, vehicles with H drive
- Measuring range: 0…1050 bar / 0…15000 psi *(see product datasheet)
- Measuring accuracy at 25 °C typ.: ± 0.3 / 0.5 % FS typ.
- Output signal: 4...20 mA, 0.5...4.5 VDC, 0...5 VDC, 1...5 VDC, 1...6 VDC, 0...10 VDC, 0.1...10.1 VDC, 0.5...4.5 VDC ratiometric, Switching output: 1 or 2 PNP
- Pressure connections: G1/4" m, 1/4"NPT m, 7/16"-20UNF SAE4 m
- Ambient temperature: 40°C…+85°C
- Suitable for thick and viscous media
- Different materials for optimum media compatibility
- EMC protection class is IEC 61000 (lightning, electrical discharge)
- Range: 0...0,1 bar to 0...6 bar
- Accuracy: +/- 0.3 %
- Output: 4...20 mA
- Ambient temperature: -25°C...+70 °C
- Process temperature: -25°C...+70 °C
- Supply: 9...32 VDC
- Protection class: IP68
- Material: Stainless steel (1.4404 (316L) / 1.4462 (318LN))
- Sensor technology: Thick film on ceramic
- Sensor material: Ceramics, Al2O3 96%
- Cable insulation: PUR / Radox / PE
- Industrial pressure transmitter’s measuring principle: Thin-film-on-steel
- Applications: hydraulics, industrial applications, machine tools
- 5-fold overpressure resistance
- Measuring range: 0...2.5 / 0...700 bar // 0...30 / 0...10000 psi
- Measuring accuracy at 25 °C typ.: ± 0.5 % FS typ. ± 0.3 % FS typ
- Output signal: 4...20 mA, 0...5 VDC, 0.5...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Ambient temperature: -40°C…+125°C
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (in range: 0...100 m/s) and flow m3/h
- Sheathed thermocouple K probe integrated, with connection cable length 1,5 m (option)
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- Accuracy: Better than 1 % for an alignment in relation to the flow axis of the fluid of ± 10 °
- Coefficient: 1,0015 ± 0,01
- Max static pressure: 2 bar
- Temperature of use: 0…600 °C (up to 1000 °C in option)
PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T4611, T3611, T7611. Only to be used with external sensors.
Application:
- Storage rooms
- Greenhouses
- Telecommunication devices
- Servers
- A/C units
PoE (power over Ethernet) temperature, relative air humidity, atmospheric pressure meters T0610, T3610, T7610. Only to be used with internal sensors.
Application:
- Storage rooms
- Greenhouses
- Telecommunication devices
- Servers
- A/C units
- Measuring range: -1…100 bar (see datasheet)
- Basic accuracy 0,5% of range
- Output: 4…20 mA
- Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
- Operating temperature: -20…+85 / 200 °C (see datasheet)
- Stainless steel housing and diaphragm material
- Protection class: IP67 / IP68
DPC 8380 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.
DPS 8381 with display works as a data logger, a transducer with a display and as a pressure switch. Logged data is read using mobile phone via NFC interface. Parameters can be either set via integrated buttons or via NFC. Display and electrical connection are independently rotatable 335°/343°. These properties greatly increase the field of application.
- Range: 0...2,5 iki 0...600 bar / 0...30 iki 0...7500 psi
- Sensor type: Thick film on steel
- Accuracy: ±0,5 %
- Output (chosen): 4...20 mA / 0...5 VDC / 0...10 VDC / 1...6 VDC
- Switching outputs: 2 x PNP
- Shown measuring units: bar, psi, MPa, kPa, m WC, mm WC
- Ambient temperature: -25...+85 °C
- Media temperature: -25...+85 °C
- Protection class: IP65
- Process connection: G1/4" m, R1/4" m, 1/4"NPT m, 1/2"NPT m
- Data logger memory: 3518 points
- Pressure range: from 0...2,5 to 0...700 bar
- Process temperature: -40...+125 °C
- Process connection: G1/4" m, G1/4" m (Manometer), 1/4"NPT m, 1/8"NPT m, 7/16"-20UNF SAE J512 f, 7/16"-20UNF SAE4 m, 7/16"-20UNF m DIN3866, R1/4" m DIN3858, R1/4" m DIN2999, R1/8" m, M10x1 m, M12x1.5 m
- Protection class: IP65, IP67
- Pressure transmitter ATM (analog output)
- Pressure measurement range: from 0 to 0,1...1000 bar
- Accuracy: < ± 0,50 / 0,25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
- Process temperature: -40...150 °C
- Operating temperature: -25..85 °C
- Materials: stainless steel, titanium
- Pressure transmitter ATM.1ST/Ex (high precision, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...1000 bar
- Accuracy: ≤ ± 0.10 / 0.05 % FS
- Output: 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -40...125 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
- Pressure transmitter ATM/Ex (for explosive Ex environment)
- Various pressure measurement ranges: 0,1...1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, IECEx, EAC
- Pressure transmitter ATM/F (hygienic)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...100 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Pressure transmitter ATM/F/Ex (hygienic, for explosive Ex environment)
- Various pressure measurement ranges: 0,1...25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Output: 0...5 VDC / 0...10 VDC / 0...20 mA / 4...20 mA
- Process temperature: -25...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel
- Certificates: ATEX, EAC
Pressure transmitter CMP 8270 with CANopen output is designed for pressure measurement from 0...1 bar to 0...600 bar. Medium accuracy, small size, high temperature- and strong vibration-resistant.
- Output: CANopen, protocol DS301 / DS404
- Range: from 0...1 bar to 0...600 bar
- Accuracy: ±0,2%
- Process connection: G¼
- Supply: 8...32 VDC
- Temperature: -50...135ºC
- Ambient temperature: -40...125ºC
- Sensor material: stainless steel (1.4542)
- Protection class: IP67
- Pressure range: from 0...0,1 to 0...40 bar
- Output signal: 4...20 mA / 0...5 VDC / 1...6 VDC / 0...10 VDC / 0,5...4,5 VDC
- Process temperature: -25...+125 °C
- Process connection: G1/4" f, G1/4" m, G1/2" m DIN3852-A, G1/2" m DIN3852-E, 1/4"NPT m ANSI B1.20.1, 1/8"NPT m ANSI B1.20.1, 7/16"-20UNF m SAE4, R1/4" m DIN3858, G3/4" frontal membrane
- Applications: Machine tools, hydraulics, water treatment
- Protection class: IP65, IP67, IP68
- Pressure transmitter for shipbuilding, engine manufacturing
- Measured pressure from 0...1 bar to 0...250 bar
- Technology: thick film on ceramic
- Output signal: 4...20 mA
- Accuracy: 0,5 %
- Operating temperature: -25...+125 °C
- Ambient temperature: -25...+125 °C
- Conformity: DNV, GL, KRS, RINA
- Protection class: min. IP68
Pressure transmitter EPN/EPNCR 8298 is suited for ship industry (up to 2500 bar). Totally enclosed, stainless steel sensor system. Long-term reliability and stability, resistance to mechanical factors.
- Range: nuo 0...2,5 iki 0...2500 bar
- Accuracy: ± 0,3%
- Output: 4...20mA / 0.5...4.5V DC
- Process connection: G1/4“, R1/4“, G1/2“, M14x1.5, M18x1.5
- Process temperature: -40°C...+125°C
- Supply: 9...32 VDC / 5 VDC ±0.25 VDC
- Protection class: IP67
- Sensor material: nerūdijantis plienas 1.4548 (AISI630)
- Certification: GL, ABS, BV, DNV, RINA, LRS, KRS, NKK, RMRS
- Certificates Ex ATEX and IECEx
- Ex-zones 0, 1, 2 (gas), 20, 21, 22 (dust) and mining
- High reliability and safety
- Extraordinary long-term parameter stability
- Range:
- from 0...0.4 bar to 0...2000 bar
- standard 0...0.4 bar to 0...250 bar
- accuracy: ± 0.2% of range
- Process connection: G1/4"
- Output: 4...20 mA
- Process temperature: -40°C...+120°C
- Ambient temperature: -40°C...+120°C
- Supply: 10...30 VDC
- Protection class: IP65
- Casing material: stainless steel 1.4452 (AISI630)/ 1.4301 (AISI304)
- Pressure transmitter is suited for ship industry, has extended temperature range and increased accuracy, M12 connection and IP67 protection class
- Small size
- Totally enclosed, stainless steel sensor system
- Long-term reliability and stability, resistance to mechanical factors
- Range: from 0...2,5 to 0...700 bar
- Accuracy: ± 0,2%
- Output: 4...20 mA
- Process connection: G1/4" m; G1/4" m (Manometer EN 837); G1/8" a, DIN3852-E; 1/4"NPT m; M10x1 m
- Process temperature: -25°C...+125°C
- Ambient temperature: -40°C...+125°C
- Supply: 9...32 VDC
- Protection class: IP67
- Sensor material: Stainless steel (1.4542)
- Certification: ABS, BV, DNV, GL, KRS, LRS, RINA, for shipbuilding
- Pressure range: from 0...6 to 0...600 bar
- Output signal: 4...20 mA / 1 x PNP / 2 x PNP
- Process temperature: -40...+125 °C
- Accuracy: 0,3 %
- Dielectric strength: 710 V
- Measurement principle: thin film on steel
- Protection class: IP65, IP67
- Conformity: EN 50155, EN 45545-2, EN 61373, EN 50121-3-2
- Parametrization by SMI programmer (not included) via Bluetooth connection from smartphone (Android)
- Pressure transmitter for shipbuilding, engine manufacturing, railways, machine tools, hydraulics
- Measured pressure from 0...2,5 bar to 0...250 bar
- Technology: thick film on steel
- Output signal: 4...20 mA
- Accuracy: 0,5 %, 0,3 %
- Operating temperature: -40...+100 °C
- Ambient temperature: -40...+100 °C
- Conformity: ABS, BV, CCS, DNV, GL, KRS, LRS, NKK, RINA, RMRS
- Increased vibration resistance
- Totally enclosed, stainless steel sensor system
- Long-term reliability and stability, resistance to mechanical factors
- Measurement range: from 0…2 to 0…2.5 bar
- Accuracy: 0,15...0,8 % (at 25 °C
- Output: 4...20 mA, 0...5 V, 0...10 V
- Process connection: G1/4 (optional G1/2 with additional adapter), 1/4” NPT
- Process temperature: -40°C...+125 °C
- Ambient temperature: -40°C...+125 °C
- Supply: 9/15...32 VDC
- Protection class: IP65 / IP67
- Sensor material: stainless steel (1.4542)
- Pressure transmitter PTM (programmable)
- Various pressure measurement ranges: 0,1...1000 bar
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Various pressure measurement ranges: 0,1...1000 bar
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 4...20 mA
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Certificates: ATEX, EAC
- Various pressure measurement ranges: 0,1...1000 bar
- Temperature measurement range: -25...85 °C
- Adjustable 1:4 of the nominal range within -5 % to +105 %
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Output: 2 x 4...20 mA
- Digital output: RS-485
- Process temperature: -40... 150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Various pressure measurement ranges: 0,1...1000 bar
- Relay output: 2 units
- Output: 0...20 mA / 4...20 mA
- Process temperature: -40...150 °C
- Operating temperature: -25...85 °C
- Materials: stainless steel, titanium
- Measuring function: differential pressure, volume flow
- Measuring ranges: multi-range switching with 8 switchable measuring ranges
- Output: switchable 0-10 V/ 4 ... 20 mA (via DIP switches)
- Allowed overpressure: 50 kPA
- Supply: 24 VAC
- Medium: clear air, non-aggressive, non-combustible gases
- Protection class: IP 54
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
- The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- With integrated K type thermocouple
- Accuracy: 1 %
- Coefficient: 0,84 ± 0,01
- Static pressure: Atmospheric
- Temperature of use: 0…1000 °C
Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.
Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.