This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Temperature transducers

Temperature transducers
Show:
Sort By:

The P17G passive separator in a housing of 6.2 mm width and supplied from a current loop, serves to the electric isolation and filtration of the 0(4)...20 mA standard signal value without an additional supply voltage.

  • The P20 programmable transducer is designed to convert temperature, resistance, voltage from a shunt and standard signals into a constant-current or constant-voltage standard signal
  • The output signal is galvanicaly isolated from the input signal and supply
  • The transducer is fully configurable through the PD14 programmer and free LPConfig software.
  • Input: Pt100 (2-, 3-, 4-wire)
  • Measurement range: -200...+850 °C
  • Resolution: 24 bits
  • Very low current consumption
  • No external power supply needed
  • Warranty: 3 years
  • Connection: RJ-11
  • Air velocity measurement range: 0...2 / 0...10 / 0...20 m/s (selectable via jumper)
  • Temperature measurement range: 0...50 °C
  • Output: 0...10 V / 4...20 mA
  • Option: LCD screen
  • Option: relay output
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...+50°C
  • Protection class: IP54
  • Temperature measurement range: -30...+80 °C
  • Humidity measurement range: 0...100 %
  • Output: RS-485 Modbus RTU
  • Calculates absolute humidity and dew-point temperature
  • Cable length: 2 m / 2 m with M8 connector / 5 m / 10 m
  • Operating temperature: -20...+60 °C
  • Supply: 9...28 VAC/VDC
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Integrated sensors
  • Calibration certificate is included
  • Economical
  • Ambient temperature and humidity transducer with 4...20 mA output
  • Stem length 700 mm
  • Calculated values: dew point temperature, absolute humidity, specific humidity, mixing ration, specific enthalpy
  • Display with two periodically changed shown values (can be switched off)
  • Integrated sensors
  • Calibration certificate is included
  • Programmable output
  • Low temperature inertia
  • For use in non-aggressive environment
  • 3 year warranty

Carbon dioxide (CO2) and temperature transmitter with a display CDT2000 Duct. The device is designed for measurement of air parameters in ventilation channels.

  • CO2 range 400...2000 ppm
  • Temperature range 0...50 °C
  • To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
  • Configuration with keypad or software: measuring ranges, units, outputs settings
  • Optional with display or without display
  • Galvanic isolation all the ways
  • On request range increase up to 0...20 000 ppm

 

Carbon dioxide (CO2), temperature and humidity transmitter with a display CDT2000.

  • Carbon dioxide (CO2) range: 400...2000 ppm
  • Humidity range: 0...100 % 
  • Temperature range: 0...50 °C

Temperature transducers P4141, P4121, P4151, P4131, P4161, P4171, P4191 with 4...20 mA output and Pt1000 input.

P4121 – P4171 class transducers are designed to convert RTD Pt1000 (3850ppm/°C) signal to current. These transducers have 4...20 mA output. RTD sensor Pt1000 is not included.

  • Input: potentiometer / 0...10 V / 4...20 mA / 3,33 mV/V / 2 mV/V / 2.5 mV/V / CANopen
  • Temperature input: none / Pt100 / Pt1000 / thermocouple
  • Analog output: none / 0...10 V / 0...5 V / 0,5...4,5 V / 0...20 mA / 4...20 mA
  • Relay output: 3 units
  • Communication interface: none / RS-232 / RS-485 / USB / CANopen
  • Invertible analogue output (10...0 V, 20...0 mA)
  • Fast and easy parameter configuration via USB
  • Optional tare function (scaling to zero)
  • Supply: 220 VAC / 24 VAC/DC
  • Operating temperature: 0...50 °C
  • Protection class: IP60 (front)
  • Pressure measurement range: -250...2500 / -250...7000 Pa
  • Input: 2 x  0...10 V, NTC10k, Pt1000, Ni1000, binary
  • Output: Modbus RTU
  • Temperature compensation in range of 0...50 °C
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC/VAC
  • Operating temperature: -20...+50°C
  • Protection class: IP54
  • PID controller
  • Pressure measurement range: 0...2500 Pa
  • Modbus RTU communication
  • Control output: 0...10 V
  • External input: 0...10 V / thermistor / binary
  • LCD display
  • Temperature compensation
  • Allowed overpressure: 25 kPa
  • Supply: 24 VDC
  • Operating temperature: -20...+50°C
  • Protection class: IP54

Duct temperature transducer with 4...20 mA output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Calibration certificate is included.

Duct temperature transducer with 0...10 V output is built in a durable watertight case. The length of stainless steel stem is 120 mm. Output temperature range is user adjustable. Calibration certificate is included.

  • Temperature measurement range: -35…+80 ºC
  • Humidity measurement range: 0…100 % RH
  • Differential pressure measurement range: -500…+500 Pa / -7000… +7000 Pa
  • Output: Modbus RTU
  • Allowed overpressure/ bellow: ± 50 kPa
  • Operating temperature: 24 VAC / 15…35 VDC
  • Protection class: IP 65
  • Ethernet connection
  • Analog inputs: 2 (0...10 VDC)
  • Digital inputs: 2
  • Relay outputs: 2 (NO/NC)
  • 1-Wire input (up to 8 sensors)
  • Memory: 70 000 values
  • Modbus TCP/IP support
  • Webserver
  • XML/JSON, HTTP API commands
  • SNMP alarms (up to 5 recipients)
  • E-mail alarms (up to 5 recipients)
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...28 VDC
  • Calorimetric measuring principle
  • Units freely selectable via keys at the display
  • Display shows 2 values at the same time, twistable by 180 ° degree
  • Integrated Modbus interface enables connection control systems, SCADA
  • M-Bus (optional)
  • Analog output 4...20 mA
  • Pulse output (galvanic isolation)
  • High measuring accuracy (ideal for leakage measurement)
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø9,8 mm
  • Length: 1...35 m
  • Tensile strength: ≤ 2,5 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C
  • Grain temperature monitoring system for steel and concrete bins
  • Digital sensors with 2-wire bus
  • Sensor spacing: 2 or 3 m
  • Diameter: Ø17 mm
  • Length: 1...100 m
  • Tensile strength: ≤ 8 t
  • Operating temperature -20...50 °C
  • Maximal surface temperature 85 °C
  • System is ATEX-, IECEx- and GOST-R approved
  • ATEX approval code: Ex II 1D Ex ia IIIC T85°C

At extra cost: 2 analog outputs (0...10V, 4...20mA), membranous filter, teflon filter, bronze filter.

The sensor changes measured parameters to an analog or a digital signal.

  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0...10 V / 2...10 V / 4...20 mA
  • Option: LCD display
  • Option: relay output
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP20
  • Temperature measurement range: 0...50 °C
  • Humidity measurement range: 0...100 %
  • Output: 2 x 0/2...5/10 VDC
  • Option: LCD display
  • Option: Modbus RTU
  • Supply: 24 VDC/VAC
  • Operating temperature: 0...50 °C
  • Protection class: IP54
  • Temperature measurement range:
    a) Ambient model: -20...+80 °C
    b) Remote model with polycarbonate probe: -20...+80 °C
    c) Remote model with stainless steel probe: -40...180 °C
  • Relative humidity measurement range: 0...100 %
  • Calculates dew point, absolute humidity, enthalpy and combination ratio
  • 4-wire analog output: 0...5/10 V or 0/4...20 mA
  • 2 relay outputs
  • Versions with or without display
  • Protection class: IP65 (ABS V0 housing)

The P18L transducer is a device destined for the continuous measurement and conversion of relative humidity and ambient temperature into a standard analog signal 4...20mA.

 

  • P18L transducer is supplied from a current loop.
  • Applied sensor shields enable the application of the P18L transducer to operate in various ambient conditions.
  • Universal input (for standard signals and temperature sensors)
  • Alarm output
  • OLED display
  • Configuration via miniUSB connector
  • Supply: 24 VDC or 230 VDC / VAC
  • IP65 protection class
  • Ethernet connection
  • Digital inputs: 2
  • 1-Wire input (up to 2 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • IP watchdog function
  • Webserver
  • SNMP alarms
  • VLAN and MAC address filtering
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC
  • 4 analog inputs (standard signals, RTD, thermocouple)
  • RS-485 Modbus output (Slave mode)
  • 2 alarm outputs
  • Galvanic isolation of inputs (2 from other 2)
  • Programmable individual characteristics, mathematical functions
  • Programmable time counters
  • Rail-mounted
  • Designed for air temperature and humidity sensors / transmitters
  • Transmitter entirely protected inside the shield
  • Prevention of condensation by downward sensor orientation
  • Advanced weather protection by maximized top cover area (Ø 250 mm)
  • Passively ventilated, requires no power
  • Plate system permits air flow through the sensor
  • ASA plastic is resistant to mechanical damage and UV radiation. It is anti-static and very stable over time.

Temperature regulator RE72 for ladder control, designed for temperature stabilization in plastics and food industries.

 

  • Universal measurement input
  • Auxiliary measurement input 0/4...20 mA
  • Binary input
  • Ladder temperature control, 15 programs with 15 intervals
  • Soft start
  • ON/OFF, PID, PID step-by-step (step valve control) or PID heating – cooling
  • 8 alarm types, alarm control
  • Timer function
  • Front panel protection class IP65
  • Backside protection class IP20

Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.

  • Ethernet connection
  • Digital inputs: 2
  • 1-Wire input (up to 2 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • Webserver
  • HTTP and XML API commands
  • E-mail alarms, SMTP, SNMP
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC
  • Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
  • Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
  • 2000 VAC galvanic isolation
  • High accuracy
  • EMC compliance - CE symbol
  • Mounting on DIN rail - EN-50022 complience
  • Supply voltage: 10...30 VDC
  • Ambient temperature: -10...+60°C

The P17 transducer, supplied from a current loop, converts the signal from temperature sensors or a standard voltage signal into a 4...20 mA current.

  • Modbus Slave over RS-485
  • Modbus RTU / Modbus ASCII protocols
  • Communication parameters configurable by dip-switches
  • Watch-dog alarm
  • Remotely configurable
  • 3-way galvanic isolation (1500 VAC)
  • High accuracy
  • Mounting on DIN rail - EN-50022 compliance
  • Ethernet 10/100 Base-T interface
  • Modbus TCP server
  • Webserver for configuration of device and representation of actual input values
  • Galvanic isolation on all the ways (1500 VAC)
  • Remotely configured
  • LED indication
  • EMC compliance
  • DIN rail mounting
  • Flexible spears for grain temperature measurement
  • Rigid construction
  • Diameter: Ø8 mm
  • Penetration depth: up to 12 m
  • Digital temperature sensor
  • Measurements are done using PC software or handheld reader GW-200
  • Temperature spears and cables can be integrated into single system
  • Measures ambient air temperature and humidity
  • Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time

Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.

 

  • Integrated temperature and humidity sensor
  • Calculated values – dew point temperature, absolute humidity
  • Minimal and maximal value memory
  • Isolated RS-485 port
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)
  • Patented quality product (immersion sensor patent)
  • Measuring ranges: multi-range switching with 8 switchable measuring ranges
  • Output: 0 – 10 V or 4...20 mA
  • Sleeve length: 50, 100, 150, 200, 250, 300, 400 mm
  • Supply 24 VAC/ VDC – U var. or 15...36 VDC I var.
  • Medium: in liquid or gaseous media
  • For aggressive media, stainless steel immersion sleeves must be used
  • Ambient temperature: -30…+70 ºC
  • Temperature regulator for usage with Pt100, Pt1000 or NTC sensors
  • PID or ON/OFF control
  • Automatic selection of PID parameters
  • One relay output and one alarm relay
  • Manual control mode
  • One binary input
  • Operating temperature: 0...50 °C
  • Supply: 230 VAC
  • Protection class: front IP65, back IP20
  • Sensor: Pt100 / Pt1000 / 2x Pt100 / 2x Pt1000, 2 / 3 / 4-wire
  • Output: 4..20 mA HART / RTD / CANopen
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Fitting length: 50...1000 mm
  • Process connection: G1/2”, hygienic
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Supply: 12...40 VDC (HART), 8...40 VDC (CANopen)
  • Protection class: IP65
  • Sensor: Pt100 (3-wire) / TC: K (with display / without display)
  • Output: HART / sensor output
  • Measurement range: -50...+400 °C
  • Configuration: via HART
  • Operating temperature: -20...+80 °C / -30...+100 °C
  • Various connection options
  • Supply: 12...40 VDC (HART), CR2032 (for screen)
  • Protection class: IP65
Loading...