This website uses cookies in order to provide better service. By using this website further you accept with this policy.
Product groups

Temperature transducers

Temperature transducers
Show:
Sort By:

Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).

The transmitter is mounted into a B-type head. Programming can be done in our company.

  • Input (configurable): TC, RTD, mV, resistance and potentiometer
  • Output: Modbus RTU / ASCII Slave device over RS-485
  • 1500 Vac 3-ways Galvanic Isolation
  • High accuracy
  • Remotely configurable over RS-485
  • EMC compliance (CE mark)
  • Mounting in B-type head
  • Easy implementation in existing PLCs and SCADA systems
  • Operating temperature: -40...+85°C
  • Supply voltage: 18...30 VDC
  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.

Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.

  • Input: RTD: Pt100 (3-wire), TC: J, K N
  • Output: IO-Link
  • Configuration: via IO-Link
  • Operating temperature: -20...+80 °C
  • Supply 24 VDC

Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.

Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.

The sensor SVT200-T require to be used with Broadsens's wireless gateway and analysis software BroadVibra.

  • Temperature measurement range: -40…+105 °C
  • Accuracy / Resolution: ±0,3 °C / 0,01 °C
  • Measurement and transmission interval: 15 seconds (Selectable: 1…60 s)
  • Power supply: CR2450W Battery. Up to 10 years in continuous usage
  • Wireless data transmission (BLE): 2.4GHz; up to 100 m in line of sight
  • Certificates: FCC, IC, CE(EU), TELEC, KCC, NCC, WPC, RCM certified
  • Mounting: Glue / epoxy. Screw mounting option available for SVT200-T-F case
  • Protection class: IP68 waterproof
  • Size / Weight: 39 mm x 14 mm / 30 g

The sensor SVT300-V require to be used with Broadsens's wireless gateway and advanced vibration analysis software BroadVibra.

  • Alarm sent out in 0,5 second when accident detected
  • Acceleration range: 2g to 16g auto adjustment
  • Acceleration sampling rate: Low speed & 6.4kHz sampling rate dynamic adjustment based on vibration level
  • Acceleration resolution: 16 bit
  • -3dB bandwidth (Hz): x,y,z axis: 0.1Hz to 3.2kHz
  • Temperature measurement range: -40…+125 °C
  • Wireless data transmission (BLE): 2.4GHz; up to 300 m in open space. FCC / IC approved
  • Battery life: 3…4 (12-hour running machine a day); 14250 battery, 1200 mAh
  • Mounting: M6 screw hole or two screw-hole case
  • Working temperature: -55…+85 °C; IP68 (IP69K optional)
  • Explosive atmosphere: Intrinsic safe. ATEX & IECEx: Ex ia IIC T4 Ga; Ex ia IIIC T135 Da
  • Thermometer DT20 for temperature measurement in smokehouses, butcheries, etc.
  • Measuring range -50...20 °C, accuracy 0,1 °C
  • Sharp-tipped probe ST-03 (4x120 mm) made of stainless, acid-resistant steel (1H18N9T)
  • Cable length 3 m
  • Operating temperature 0...40 °C
  • Supply 230 V
  • Size 130x94x81 mm
  • Ergonomic ABS casing with indicator, IP65
Loading...