Pressure peak damping element, designed to be used to protect measuring devices from sharp pressure changes in system. Made by Trafag (Switzerland).Environment: air, waterProcess connection: G1/4 male, G1/4 female (brass), G1/2 male, G1/4 male (stainless steel)Material: Stainless steel (model K5) or brass (model F5) Pressure peak damping element datasheet [EN, DE, FR] ..
  • Software to work with Comet devices Sxxxx, Rxxxx, UxxxxM, Dxxxx and Mxxxx
  • Device settings
  • Data download
  • Analysis of critical situations
  • Presentation of measured data
  • Reports
  • Database import/export
  • Free license
  • Dedicated to following devices: N14, N27P, N30P, N43, N100, ND10, ND20, P41, P43
  • Monitors, archives, visualizes measured data, generates reports
  • Communication protocols: Modbus RTU, Modbus TCP
  • Reading interval: 1...60 s
  • Archiving interval: 1 s...1 h
  • License types: for up to 5 / 10 / 30 / 50 devices
  • Optional communication with other Modbus RTU/TCP devices
  • Multiple user access with varying levels of authorization
  • Remote access to PowerVis software through a web browser
  • Languages: English, German, French, Spanish and Polish
  • Separator alarm system for applications where mains supply is not available
  • ATEX certified
  • Alarms:
    • high level detection
    • oil on water surface detection
    • sludge under water detection
  • SolarSet Beacon consists of:
    • housing containing and panel
    • battery
    • charger controller
    • flashing beacon for alarm
    • sludge and oil level sensor system LevelSet S
  • Separator alarm system for applications where mains supply is not available
  • ATEX certified
  • Alarms:

• high level detection

• oil on water surface detection

• sludge under water detection

  • SolarSet Beacon consists of:

• housing containing and panel

• battery

• charger controller

• GSM/GPRS modem

• flashing beacon for alarm

• sludge and oil level sensor system LevelSet S

  • Separator alarm system for applications where mains supply is not available
  • ATEX certified
  • Alarms:
    • high level detection
    • oil on water surface detection
    • sludge under water detection
  • SolarSet Beacon consists of:
    • housing containing and panel
    • battery
    • charger controller
    • GSM/GPRS modem
    • sludge and oil level sensor system LevelSet S

Solenoid valve SCG238 (Asco).

  • Normally closed, does not produce hydraulic shocks, pilot
  • Solenoid valve complies to all associated EC directives
  • For hot and cold water (on/off function)
  • Self-cleaning breather guarantees reliable function
Solid particle (dust) concentration meter Dust Trak DRX. Models 8533, 8834.DUSTTRAK DRX monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK DRX monitors measure aerosol contaminants such as dust, smoke, fumes and mists. ..
The new DUSTTRAK II Aerosol Monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK II monitors measure aerosol contaminants such as dust, smoke, fumes and mists.          &n..

For on-line measurements of air pollution or combustion gases flow in chimneys or flues.

  • Flexible spears for grain temperature measurement
  • Rigid construction
  • Diameter: Ø8 mm
  • Penetration depth: up to 12 m
  • Digital temperature sensor
  • Measurements are done using PC software or handheld reader GW-200
  • Temperature spears and cables can be integrated into single system

By means of three light barriers the SI-JET spray jet control systems check the density, symmetry, and cone angle of the spray jet. Choked or incorrectly set nozzles can thus be detected in time. Due to the integrated pressed air facility (at transmitter and receiver side of the fork) these systems are insensitive to dirt accumulation.

Stainless steel gauge cock, vent hole type. Technical specificationsProcess connection:  in case of 3 way gauge cock 1/2 (MxFxF), in case of 2 way gauge cock 1/4, 1/2, 3/8, (FxF), (MxF), (MxM); Operating temperature: up to 180 °C;Max pressure: up to 100 kg/cm²;Housing: stainless steel AISI 316 SS;  05-03 datasheet [EN] ..

Hydrostatic level meter HLM–25C is compact measuring device containing ceramic tensometric sensor and evaluation electronics in stainless steel probe. Ceramic sensor is resistant to lightly soiled, or sludge water. From the probe housing comes out 2-wire cable with capillary (for atmospheric pressure compensation). The front side of the sensor is open, therefore the level meter is resistant to capture gross (solid) impurities.

  • For continuous level measurement of clean, lightly soiled, or sludge water in non-pressure reservoirs, boreholes, tanks etc.
  • The measurement range up to 100 m (H2O)
  • The health certificate for contact with potable water available
  • Output: 4…20 mA or 0…10 V

Submersible level sensor CLS–23S is developed as reliable and low-cost solution for limit level sensing of water (or water solutions) with miniature outer dimensions without the needs of any adjustment. The connection is done by means of two wires directly to a circuit with relay or to binary input of control system.

  • For level detection of water in wells, boreholes or tanks
  • Two-wire connection directly to the relay circuit or PLC input (current switch)
  • Maximum immersion depth 100 m
  • Stainless steel protection basket avoids mechanical damages of electrode
  • Supply voltage: 6…30 VDC
  • Protection class: IP68
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution < 0,1 / 1,5 ppm SO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 2 / 5 ppm SO2
  • Attached or remote sensor
  • Stable long-life electrochemical cell
  • Range 0...50 / 0...2000 ppm SO2
  • Resolution 0,1 / 1,5 ppm SO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor
  • Electrochemical gas sensor
  • Range: 0...50 ppm SO2 / 0...2000 ppm SO2
  • Resolution: 0,1 ppm SO2 / 1,5 ppm SO2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11..30 VDC / 24 VAC or 90...265
  • Available versions with 2 to 8 primary windings
  • Nickel plated secondary terminals
  • Multiple mounting methods, including wall mounting and on DIN rail
  • Applicable standard: IEC 61869-1/2
  • Rated primary current: (2...8) x 5 A
  • Rated secondary current: 5 A
  • Rated burden: 5 / 10 / 15 / 20 / 25 A
  • Max system voltage: 720 V
  • Operating temperature: -25...+40 °C
  • Accuracy class: 0,5 / 1

RSP-E25-... is a Class I+II SPD for surge and lightning protection of low-voltage power supply systems, especially in high-risk exposure areas or building entrances in LPZ 0-2 (IEC 62305-4), protecting against damage caused by direct or nearby lightning strikes; suitable for use in main distribution boards.

  • IEC / EN / VDE category: Class I+II / Type 1+2 / B+C
  • Application: main distribution boards (MB)
  • Power networks: TT, TN-S, TN-C
  • Protection modes: L-N, N-PE
  • Protective elements: MOV, MOV+GDT
  • Enclosure: modular (replaceable module)
  • Mechanical status indicator: green/red flag
  • Compliant with standards: IEC/EN 61643-11:2011, IEC 60364-4-53, IEC 62305, CE, RoHS
  • Destined to synchronize generator, wind, water turbine and similar devices connecting to the network
  • Eliminate voltage difference, frequency, and phase shift angle
  • Ethernet interface 10/100 base-t, RS-485 interface with Modbus RTU protocol
  • Web server, Modbus TCP / IP, DHCP server
  • Protection class from frontal side: IP65, terminal side: IP20
  • Electrical safety CAT III measurement category
  • Voltage range (resolution): 20...180 V (0,1 V), 60...480 V (0,1 V), ...1920 kV (0,01 kV)
  • Voltage difference (resolution): -20...0…20 % (0,1 %)
  • Frequency range (resolution): 45...65 Hz (0,001 Hz)
  • Frequency difference (resolution): -10...0...10 % (0,01 %)
  • Phase shift (resolution): 0...360 o (0,1 o)
  • Universal datalogger with 4 hardware MiniDIN inputs for connecting temperature and humidity probes.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 3 hardware MiniDIN inputs for connecting temperature and humidity probes and 1 for external CO2 sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • External CO2 sensor, 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures carbon dioxide (CO2) using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Measures barometric pressure using the integrated sensor.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 hardware MiniDIN inputs, 2 for thermocouples K, J, S, B, T, N and 2 for connecting temperature and humidity probes.
  • Cold junction compensation (CJC).
  • Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
  • Open collector transistor alarm output.
  • Universal datalogger with 4 hardware MiniDIN inputs for thermocouples K, J, S, B, T, N.
  • Cold junction compensation (CJC).
  • Sensors of physical quantities with bipolar voltage output can also be connected. Two voltage ranges: -18...+18 mV and -60...+140 mV.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Thermocouples are ordered separately.
  • Open collector transistor alarm output.
  • Memory: up to 70 000 records
  • Up to 8 1-Wire and Modbus RTU sensors support
  • Temperature, humidity and dew point graphical representation
  • Modbus TCP/IP support
  • XML/JSON and HTTP API commands
  • Webserver
  • E-mail alarms (up to 5 recipients)
  • Operating temperature: -20...+55 °C
  • Warranty: 3 years
  • Supply: 10...32 VDC
  • Measures ambient temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+80 °C, 0...100 %RH
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30
  • Calibration certificate included
  • Measures ambient temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measuring ranges: -30...+105 °C, 0...100 %RH
  • External sensor cable length: 1 / 2 / 4 m
  • Output: Ethernet
  • Optional connection to WiFi network via tiny wireless router TL-WIFI
  • Webserver
  • Measurement interval: 2 s
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Supply: 9...30 VDC
  • Protection class: IP30 for device, IP40 for sensor
  • Calibration certificate included
  • Measures ambient air temperature and humidity
  • Integrates seamlessly into GrainWatch PC Software and displays the ambient weather conditions in real-time
  • Temperature measurement range (depends on probe type): -30...+80 °C / -50...+125 °C / 0...+50 °C
  • Humidity measurement range: 0...100 %
  • 4 channels: 4 x external temperature probes or 4 x external temperature and humidity probes
  • Output: Ethernet
  • Measurement interval: 2 s
  • Communication protocols: WWW, Modbus TCP, SNMPv1, SOAP, XML
  • Alarm protocols: E-mail, SNMP Trap, Syslog
  • Included calibration certificate
  • Supply: 5 VDC
  • Protection class: IP30

Temperature and air humidity transducer P19 with RS-485 output, designed for room humidity ant temperature contro. Can be used in various control and monitoring systems. Output signal is digital (RS-485, MODBUS). Transducer parameters are programmed via PC. Wall-mounted. Can work in condensation-free environment.

 

  • Integrated temperature and humidity sensor
  • Calculated values – dew point temperature, absolute humidity
  • Minimal and maximal value memory
  • Isolated RS-485 port
  • Measures air temperature, humidity
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...+80 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...105 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • External sensor cable length: 1 / 2 / 4 m
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included
  • Measures air temperature, humidity in ducts
  • Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
  • Measurement ranges: -30...125 °C / 0...100 %RH
  • Operating temperature: -30...+60 °C
  • Ex marking: EX II 3G Ex ic IIC T6 Gc
  • Output: 4...20 mA, galvanically isolated
  • Adjustable by PC
  • Supply: 9...30 VDC
  • Calibration certificate included

Temperature and standard signal transducer P30U.

 

  • Programmable input
  • Mathematical functions
  • Individual channel characteristic
  • 1 or 2 outputs
  • Variant with internal transducer 24 VDC power supply
  • RS-485 interface
  • Adjustable dimension
  • Data logging into internal memory (4 MB) or SD/SDHC card (4 GB)
  • Transducer programming with buttons or via PC (“LPConfig” software)
  • Selectable double set point
  • Selectable TC / Pt100 input (order option)
  • Output: relay (control or alarm) and SSR (control)
  • PID control
  • Self-tuning feature
  • Soft-start function
  • Offset feature for input
  • Heating/cooling control
  • Manual control feature
  • Two set points
  • Input: TC (J, K, T, R, S) / RTD (Pt100)
  • Control output: relay or SSR
  • Auxiliary output: relay
  • PID / ON-OFF control
  • Auto-Tuning / Self-Tuning
  • Alarm modes: deviation, absolute
  • Heating / cooling control
  • 4+4 digits high contrast LED display
  • Supply: 85…270V AC / DC
  • Ambient temperature: 0…50 °C
  • Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
  • TR-040 (external setting): 0...40 °C
  • TR-040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Relay
  • Switching capacity: 24...250 VAC (16 A)
  • Ambient temperature: -35...65 °C
  • Protection class: IP65
  • TR series indoor thermostat with two temperature settings.TR-04040 (external setting)
  • TR-04040 (external setting): 0...40 °C/0...40 °C
  • TR-04040U (internal setting): 0...40 °C
  • TR-060 (external setting): 0...60 °C
  • TR-060U (internal setting): 0...60 °C
  • Output: Switch
  • Switching voltage / current: 24...250 V, 16 A AC
  • Ambient temperature: -35...65 °C 
  • Protection class: IP65
  • Temperature measurement range: -90...+260 °C
  • Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -30...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP67
  • Warranty: 3 years
  • Inputs: 4 x Pt1000
  • Temperature measurement range: -90...+260 °C
  • Accuracy: ±0.2 °C (±0,2 %, when temperature is in range of +100...+260 °C)
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+60 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP67
  • Warranty: 3 years
  • Input: 4x external Pt100 sensors
  • Measuring range: -200…+260 °C
  • Accuracy: ± 0.2 °C (± 0,2 %, when temperature is in range of +100...+260 °C)
  • Resolution: 0,1 °C
  • Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
  • Logging interval: adjustable 1 s...24 h
  • Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
  • Data can be transferred to PC via USB-C interface
  • Calibration certificate included
  • Ambient temperature: -20...+70 °C
  • Supply: lithium ion 3,6 V AA battery
  • Protection class: IP20
  • Warranty: 3 years