  • Transducer for DC current and voltage into other DC signal (2 outputs)
  • Input, output and supply of the transducer are galvanic insolated
  • The construction of the transducer ensures accurate and fast signal transformation
  • Fast and easy installation on rail, or onto a wall or in panel using holder
  • PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
  • This enables to increase device number in the system and extend its range
  • Signal transducer P20Z is designed to convert AC current and voltage (without direct component) into DC voltage or current signal
  • Input is isolated from input and supply
  • Has fixed inputs and outputs – non-programmable
  • TOR-1 transformer oil tester is designed to detect the mass fraction of dissolved water in insulating mineral oils the viscosity of which does not exceed 70 mm2 / s (cSt) at the temperature of 50 °C
  • Operating range of relative value aw (active water): 0…1
  • Operating range of dissolved water content measurement: 0….500 ppm
  • Precision at 20 °C ± 0.02 aw (0…0.9 aw) ± 0.03 aw (0.9…1 aw)
  • Operating medium temperature: 0…55 °С
  • Measured temperature of oil displayed on screen
  • Measurement results can be printed out using an integrated printer
  • LCD-panels displays the moisture and temperature of tested oil
  • Power supply: 220 V a.c
  • Easy use for oil testing in the field near the transformer

Trigger light barriers are mainly used in the field of metal stamping. The TLB series comprises light barriers with infrared light beam (IR) or visible light beam (VIS), in split shape as well as in fork shape (with or without compressed air supply). Characteristic for all light barriers of TLB Series is the external electronics: Pulsating light or constant light amplifier with digital output or analog output (voltage output and current output).

  • Input: infrared sensor (850 nm)
  • Output: 4...20 mA current loop with HART interface, 2x PNP or NPN
  • Measurement range: 0...10 kNTU
  • Measurement rate: 10 measurements per second
  • Display, LED indication
  • Operating temperature: -40...+75 °C
  • Protection class: IP65
  • Supply: 24...30 VDC
  • Simultaneous detection of two gases (please ask for available gas combinations and possible limitations)
  • Switch output: 4 x SPDT (2 for each sensor)
  • Alarms: LED indicators and buzzers (85 dB)
  • Supply: 24 VDC/VAC / 90...265 VAC
  • Protection class: IP65

Traditional U-shaped with easily controlled zero point. For air and non-aggressive gasses.

  • Range: -500...500 Pa

 

Ultrasonic level meter ULM-53 is designed for continuous liquid (even if polluted), mash and paste materials level measurements in closed and open tanks, sumps, open channels, etc. Adjustments are made with two buttons. State indication by two LEDs. Current (4...20 mA, 20...4 mA) or voltage (0...10 V, 10...0 V) outputs. Xi version is for usage in explosive areas.

  • For continuous non-contact water level measurement in outdoor applications - rivers, canals, sumps, liquid and slurry, pastes and bulk materials
  • Remote installation and communication via HART® protocol
  • Output: 4…20 mA, HART®
  • Variable installation thanks to the possibility of connection via lower or upper thread
  • Intelligent numerical signal processing with the elimination of false reflections
  • Protection class: IP68
  • With the help of a directional funnel it is possible to increase the reception of the reflected echo and to measure problematic media (foaming levels, loose materials, etc.)
  • Operating temperature: -30…+60…+70 °C

ULM-70 is designed for continuous non-contact level measurements. Suitable for usage in various liquids and bulk-solid materials. OLED display. Fast measured values representation on display. Current (4...20 mA) output with HART protocol. Xi version for usage in explosive atmosphere.

  • Up to 10 / 15 m level measurement with automatic temperature compensation
  • Calculation of filling in the tank or flow in open channels
  • Galvanically isolated 0/4...20 mA analog output
  • Digital RS-485 Modbus RTU interface
  • 2 alarm outputs
  • Internal data and setup memory
  • Two 32-points individual characteristics (for recalculation)
  • LCD screen
  • Housing protection grade: IP66
  • Sensor protection grade: IP66 / IP 68
  • Supply: 12...25...40 VDC
  • Operating temperature: -20...23...55 °C
  • Ultrasonic level sensor ULS-53 is designed for non-contact level sensing of various liquid and bulk-solid materials in closed or open tank, vessels, sumps, reservoirs etc.
  • Adjustment are made by two buttons or by magnetic pen
  • State indication by two LEDs
  • Output:
    • PNP transistor with an open collector (max. switch current 300 mA)
    • Two-state current switch 4…20 mA
  • Xi version for usage in explosive areas
  • Up to 10 / 15 m level measurement
  • Analog output: 4…20 mA
  • Digital output: RS-485 Modbus RTU
  • Resolution: 3 mm
  • Supply: 24 VDC / 300 mA
  • Operating temperature: -20...60 °C
  • Cable length: 1 m
  • Universal measuring inputs, it can be used for controlling of temperature (RTD, thermocouple) and other physical values
  • Colored TFT display presentation of measured values (numerical values, bar graph, meter, graph)
  • Control algorithms On-Off; PID; 12 segmental adjustment program
  • Interfaces: USB, RS485 (MODBUS-RTU) and Ethernet (100Base-T, TCP / IP protocols: Modbus-TCP, HTTP, SMTP)
  • Internal webserver, information about the active channel, measuring parameters and the status of the regulation, requires access
  • Available alarm sound and visual, status outputs and alarm notification e-mail
  • Write data in a standard text file located in the internal controller memory (4GB) FAT with the possibility of editing in spreadsheets such as Microsoft Excel
  • Selection of PID parameters for each output
  • The possibility of creating inter-channel type mathematical and logical operations: the difference, average, sum, bigger, smaller measurement
  • Function digital inputs (BIN) to changes modes associated outputs, retransmission of measurements
  • Free software for data processing and device programming
  • Controller is destined to control the temperature and other physical quantities like pressure, humidity, level
  • Three optional outputs (0/4...20 mA ± 0,2 %, 0...10 V ± 0,2 %, 0/5 V, relay voltage output)
  • Universal input for RTDs, thermocouples and analog signals
  • Configuration parameters via keys or an optional RS-485 Modbus and free eCon software
  • The controller has three alarms, which can be assigned to each output
  • The output signals are galvanic isolated from the input signals and power supply
  • Selection of PID parameters for any unit, or auto-tuning
  • Protection class from frontal side: IP30, from terminal side: IP20

The RE4X series controllers have a wide range of process control options and versions. Programmable inputs for standard signals, signal difference measurement between channels, control algorithms ON / OFF, PID, soft start and Fuzzy logic. Remote control with SCADA system through RS-485. The required output types can be selected during ordering (relays, SSR, analog).

Main features:

  • Sampling rate (5 times / second)
  • 1 input: TC and RTD sensors; standard signals 0 / 4…20 mA and 0…10 V
  • 2 input: 0 / 4…20 mA and 0…10 V
  • Binary input for changing the function of the controller and SP switching
  • Outputs: relays - NO, SSR; analog - 0 / 4…20 mA and 0…10 V
  • Galvanically isolated transducer and sensors power supply 24 V d.c. 25 mA
  • Programmable digital filter
  • Hardware and software security before changing settings
  • Alarm for breaking the control loop
  • Supply: 90…264 V a.c. or 11…26 V a.c. / d.c.
  • Protection class: IP65
  • Rated load: 1000 / 1500 / 3000 kg
  • Output: 4...20 mA HART / 10 VDC
  • Function: tension / compression / tension and compression
  • Vibration protection
  • Operating temperature: -25...+60 °C
  • Supply: out of current loop / 10 VDC
  • Protection class: IP54

The RE12S Universal PID Controller is an advanced and versatile device designed for precise process control in various industrial applications. With adaptive, auto, and self-tuning PID as well as ON-OFF control capabilities, the RE12S ensures optimal performance in maintaining desired setpoints. It features a dual LED display, capacitive touch keypad, and supports up to 128-step profiling for complex control requirements. The unit's robust communication options, including RS485 MODBUS RTU, allow seamless integration into existing systems, enhancing both functionality and connectivity.

  • Control algorithm: Adaptive, Auto, Self-tune PID, ON-OFF
  • Input: Thermocouple (J, K, T, R, S, C, E, B, N, L, U, W, Platinel II), RTD (PT100), - 5…56mV, 0…10V, 0…20mA
  • Alarm Outputs 3x: Multiple settings including deviation high/low, absolute high/low, band, sensor break
  • Profile Controller: Up to 128 steps
  • Special Modes: Heat-Cool PID, Auto/Manual, Single point ramp/soak, Soft start
  • Communication: RS485 MODBUS RTU
  • Power Supply: 90...270 VAC / DC (50/60Hz)
  • Display: 4+4 digit, 7 segments
  • Ambient temperature / humidity: 0…+50 °C / < 85%RH
  • Dimensions: 52 x 52 x 76 mm

General purpose regulator AR630 is designed for usage in humid or dusty environment (IP65). RS-232, RS-485 or analog ports are optional. Two programmable inputs (for temperature sensors and DC). Settings are protected by password. Set point blocking. Manual output control. Modification AR632 has two indicators (for set point (SP) and process value (PV)).

General purpose regulator with one programmable input and 2 or 3 outputs. Variant with RS-485 is used for work in measuring systems. Programmable binary input for remote work mode modification. PID autotuning. Free software for configuration. Manual control feature.

  • RTKSA series thermostat have cooling or / and heating functions
  • Temperature control range: -10, 0, 20, 30, …50, 110, 120, 150 °C
  • Two-way switching contact
  • Number of outputs: up to 4
  • Number of control ranges: up to 2
  • Sensor element: capillary tube
  • Capillary tube length: up to 12 m
  • Maximum switching voltage: 230 V AC 50 / 60 Hz, 230 V DC
  • Maximum switching current: NC: 16 (2.5) A; NO: 6.3 (2.5) A, 0,25 ADC
  • Minimum switching voltage: 24 V AC / 50 Hz, 24 V DC
  • Universal mounting
  • Ambient temperature for head: up to 80 °C
  • Protection class: up to IP65
  • Safety and EMC: in accordance DIN EN 60730
  • Sensor AR434 compatible with Wireless data logger AR407
  • Input:
    • RTD: Pt100 / Ni100
    • TC: J / K / S / B / R / T / E / N
    • Analog: 0…20mA / 4…20mA / 0÷10V / 0…60mV
    • Resistance: 0…700Ω
  • Radio transmission in ISM 868MHz band, range up to 200 m in open space (400 m when retransmission activated requires supplying sensor via the mini-USB port)
  • Built-in measurement of ambient temperature (20…70 °C)
  • LCD display showing the measured values, messages and errors
  • Protection: IP20
  • Power supply: battery (3.6 V, AA type)
  • Battery lifetime: up to 2 years, at room temperature, with measurement period > 40 min and uninterrupted radio transmission
  • Parameter configuration via USB serial interface
  • Variation of device without LCD screen (AR433)
  • In PD24 converter are used 2 interfaces (USB, RS232) - galvanically isolated
  • USB interface (type A) – destined for the device communication with the computer
  • RS-232 interface - destined for the communication with devices from the object side
  • PD24 is programmer of LUMEL products to configure settings using eCon software
  • Compliance with the standard USB 1.1 and USB 2.0
  • Data transmission rate up to 115.2 kbps
  • Support virtual serial port (COM)
  • Device supplied from USB port and from the RS-232 (TTL) side
  • Set includes 1,5 m data transmission cable with RJ12 plugs to configure LUMEL products
  • External dimension: 62 x 25 x 20 mm
  • In PD20 converter are used 2 interfaces (USB, RS485) - galvanically isolated
  • USB interface (type A) – destined for the device communication with the computer
  • RS-485 interface - destined for the communication with devices from the object side
  • Compliance with the standard USB 1.1 and USB 2.0
  • Data transmission rate up to 115.2 kbps
  • Support virtual serial port (COM)
  • Bi-directional data transmission (half duplex)
  • Device supplied from USB port
  • External dimension: 76 x 25 x 20mm
  • Converter does not interfere into the structure of data transmission and is compatible with many industrial communication protocols
  • Pressure measurement range: 5...25000 μm
  • Operating temperature: -10...+50 °C
  • Overload: 610 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases

SV23 Sensor help customers monitor spaces where cameras cannot be deployed and get insight into environmental conditions that cameras cannot detect. From protecting school bathrooms against bullying and vaping to gathering real-time insight into air quality conditions like carbon dioxide levels.

  • Measurement objects:
    • Vape index – for vape smoke detection, range: 0…100
    • PM2.5 - concentration of particulate matter, range: 0…10000 μg/m3
    • TVOC index, range: 0…500
    • Motion detection – FoV (field of view): 120 °
    • Noise – range 20…120 dB
    • CO2 (carbon dioxide) – range: 0…40000 ppm
    • AQI (Air quality Index) - range: 0…500
    • Temperature – range: -5…+45 °C
    • Humidity – range: 0…95 % (non-condensing)
  • Cloud Storage: up to 365 days
  • Connectivity: RJ-45 cable connector for Network / PoE powering IEEE 802.3af
  • Receive alerts for offline sensor and device tampering
  • Operating temperature range: -5…+45 °C
  • The Vape Detector FD-VAPE-WALL operates using the TUYA Smart App
  • Connection via WiFi
  • Possibility to pair with TUYA camera and create scene to record when vape alarm triggered
  • Sensors: PM2.5 Laser Scattering, Temperature and Humidity
    • PM2.5 Detection Range: 0-999 µg/m3
    • PM2.5 Response Time: 5 seconds
    • Temperature Detection Range: 0…60 °C
    • Temperature Response Time: 5 seconds
    • Humidity Detection Range: 0 - 100% RH
    • Humidity Response Time: 5 seconds
  • Working Environment: 0…60 °C < 99% RH
  • Power Supply: 5V DC USB (micro USB)
  • Pressure range: from -0,9...1,5 to 4...40 bar
  • Output signal: 1 Floating change-over contact (SPDT)
  • Process temperature: -40...+150 °C
  • Process connection: G1/4" f, G1/2" m, 1/4" NPT f
  • Protection class: IP65
Vertical float level sensor LV for fluid tank monitoring, automation, testing, measuring and control devices. Technical specifications Switching power ≤ 10 W Switching voltage ≤ 200 V Switching current ≤ 0,5 A Ambient temperature -20...90 ºC Casing material PP (polypropylene) for water and weak acid devices  LV datasheet [LT] ..
Vertical stainless steel float level sensor LB-3. Technical specificationsHousing: top;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..
Vertical stainless steel float level sensor LB-4. Technical specificationsHousing: side, 90° angle;Material of float: stainless steel AISI 316 SS;Process connection:  1/4 BSP (M);Max. temperature: 100°C;Max. pressure: 10 bar;Switch rating: 0,5 A;Switching voltage: 230 V AC;  LB datasheet [EN] ..

Fluid manometer for air and non-aggressive gasses – high quality pressure meter for narrow temperature ranges.

  • Range: 0…10 kPa
  • The program is designed to represent and log measured values
  • Representation tools: bar graphs, graphs, numbers
  • Interfaces: RS-485 MODBUS RTU, ASCII, LUMBUS, MODBUS TCP/IP
  • Number of MODBUS devices that can be represented (1 device – 1 address): 5, 10, 30 and 100 (selected while ordering)
  • Data logging: tables and/or graphs in PC memory
  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm LEL
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Remote probe option
  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 0,1 % LEL
  • Outputs 2 relays with switch-over contacts
  • Default alarm set-points 10 % / 25 % LEL
  • Visual and acoustic alarms
  • For toluene, xylene and ethanol
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL (0...1 % vol) toluene
  • Resolution 3 ppm toluene
  • Outputs 2 relays, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 % / 50 % LEL
  • Acoustic alarm
  • For toluene, xylene, ethanol, etc.
  • Default calibration toluene
  • Long-life metal-oxide sensor
  • Range 0...100 % LEL
  • Resolution 3 ppm toluene
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Remote probe option
  • For toluene, xylene, ethanol and 2-propanol
  • Default calibration toluene
  • Stable long-life metal-oxide sensor
  • Range: 0...100 % LEL or 0…500 ppm
  • Resolution 0,1 % LEL or 1 ppm
  • Outputs: 2 relays with switch-over contacts
  • Acoustic and visual alarms
  • Photo ionization detector
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: isobutylene
  • Range: 0...40 / 0...200 ppm (isobutylene)
  • Resolution: 1 / 1 ppb
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+65 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Metal-oxide gas sensor
  • Detected vapors: acetone, ethanol, toluene, xylene, etc.
  • Standard calibration: toluene
  • Range: 0...100 % LEL (flammable range) / 0...1000 ppm (toxic range)
  • Resolution: 0,1 % LEL / 1 ppm
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Input (single option): 100 V, 250 V, 400 V, 1 A, 5 A, 20...500 Hz
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40/60 VAC/VDC
  • Protection class: IP65
  • Input (single option): 0...100 V, ±100 V, 0...400 V, ±400 V
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Display: 3-color LED, 5-digit
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65
  • Input (single option): Pt100, J, K, 0...20 mA, 4...20 mA, ±20 mA, 0...75 mV, 0...10 V, ±10 V, 0...150 mV, ±75 mV, V150 mV
  • Voltage measurement range: 0...75 mV; 0...150 mV; 0...10 V (DC)
  • Current measurement range: 0/4...20 mA; ±20 mA (DC)
  • Temperature measurement range: -50...400 °C (Pt100); -50...1200 °C (J) / -50...1370 °C (K)
  • Digital output: RS-485 (Modbus RTU)
  • Relay outputs: 2x OC
  • Auxiliary 24 VDC output to supply transducers
  • Display: 3-color LED, 5-digit
  • Temperature compensation
  • Galvanic isolation
  • Supply: 85...253 VAC/VDC / 20...40 VAC/VDC
  • Protection class: IP65
  • EDP2041 is standard signals generator (digital potentiometer) with outputs:
    • 0…10 V; Resolution: 1 mV; Fluctuation: max 30 mA; Rise time from 0 to 10V is max. 300ms
    • 0 / 4…20 mA; Accuracy: 0.1 %; Resolution: 2 µA; Fluctuation: max. 60 µA
  • Preset value can be adjusted from external buttons
  • Communication via RS-485 Modbus protocol or synchronous running between two or more potentiometers
  • Display scale can be adjusted between -1999 and 9999
  • Soft on and soft off properties can be selected
  • 4 digits display
  • Parameter access protection on 3 levels
  • Supply: 230 V AC; 24 V AC; 9…30 V DC
  • Ambient temperature: 0…50 °C

The LP10-V monitors the AC voltage of the system / equipment and protects it against overvoltage, undervoltage and phase failure problems. It also indicates faults with LED indicators.

Applications: Motor protection, Server rooms, Control system

Features:

  • Compact size 17.5 mm
  • True RMS measurement
  • Under voltage protection
  • Over voltage protection
  • Phase unbalance protection
  • Phase failure protection
  • Phase incorrect sequence protection
  • Neutral failure protection
  • Adjustable Nominal voltage, Trip point, Trip time delay
  • Onsite selection of VLL / VLN value-based tripping
  • Self-powered
  • 1CO, 1CO+1CO relay configuration
  • LED indication for faults
  • Disabling of Over & Under Voltage fault on site is possible
  • Universal datalogger with 4 inputs for voltage, current, logic and pulse signals.
  • Multilogger can be installed permanently to Ethernet network or work as a portable device.
  • Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
  • Calibration certificate included.
  • 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
  • Open collector transistor alarm output.
  • Voltmeters for AC voltage measurement EP27, EP29 with a change-over switch
  • Panel electromagnetic devices, designed for effective voltage measurement
  • Change-over switch, when activated, enable the measurement of linear and phase voltage (6 measurement points)
  • Tropical version is available (TIII)
  • Voltmeters for usage with voltage transformers (X/100 V and X/110 V) are also available
  • Volumetric flow and air velocity meter with linear analogue output in control quality (0...10 V & 4...20 mA) and switch
  • Suitable for media temperatures up to 350°C
  • Measured value display by means of LCD and LED
  • Freely scalable measuring range m/s, m³/h, l/min
  • Sensitive and fast airflow detection up to 30 m/s
  • Exemplary areas of application: Measurement and control of air flows, building services, PLC, filter monitoring, extraction and extrusion systems, exhaust gases and test benches
  • Pressure measurement range: 0...1000 Pa, 0...5000 Pa
  • Volume flow, differential pressure measurement, filter monitoring and liquid level detection
  • Volume flow: 10...100% [m3/s][m3/min][m3/h]l/s][l/min][l/h]
  • Filter monitoring: 10...100%
  • Liquid level detection: 0 – 8...14 cm or 0 – 39...72 cm (depends on pressure range)
  • Output: 0 – 10 V, 1 x changeover contact
  • Measurement element: piezoresistive sensor
  • Application: in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spay booths, in large scale catering facilities, for filter monitoring and level measurement or for triggering frequency converters.
  • Medium: clean air, non-aggressive, non-combustible gasses