- MOS gas sensor
- Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
- Standard calibration: R-404a
- Range: 0...1000 ppm HFC
- Resolution: 1 ppm HFC
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -30...+60 °C
- Supply: 11..30 VDC / 24 VAC arba 90...265 VAC
- Measurement range: -40...+150 °C
- Temperature measurement accuracy: ± 1,3 °C
- Operating temperature: -20...+50 °C
- Used with wireless manifold
- Cable of 2 m length
- 124 refrigerant gases
- Pressure measurement range: -1...60 bar
- Pressure measurement accuracy: ± 0,5 % of full scale
- Overload: 65 bar
- Operating temperature: -20...+50 °C
- Used with wireless manifold
- 124 refrigerant gases
Regulator RE22 is designed to control furnace, dryer, cast machine and other devices’ temperature.
Regulator RE55 is designed to control temperature in food and chemistry industry.
Temperature regulator RE71 is designed for fixed range and sensor. Input type is selected while ordering. Control: ON/OFF, PID, PID+Autotuning, Smart PID.
Temperature regulator RE72 for ladder control, designed for temperature stabilization in plastics and food industries.
- Universal measurement input
- Auxiliary measurement input 0/4...20 mA
- Binary input
- Ladder temperature control, 15 programs with 15 intervals
- Soft start
- ON/OFF, PID, PID step-by-step (step valve control) or PID heating – cooling
- 8 alarm types, alarm control
- Timer function
- Front panel protection class IP65
- Backside protection class IP20
Temperature regulator RE81 for fixed range and sensor, with 2 switch or SSR outputs, designed for control in heating, conditioning systems. Function for 3-position control. Control: ON/OFF, PID, PID+Autotuning, Smart PID and 3-position. Input type selected when ordering.
Process regulator RE82 is designed for temperature stabilization in plastics and food industry.
Relative humidity and temperature transducer P18D with display and RS-485 output, designed for temperature and humidity measurement.
- Ethernet connection
- Digital inputs: 2
- 1-Wire input (up to 2 sensors)
- Analog inputs: 2 (0...60 VDC)
- Relay outputs: 2 (NO/NC)
- Webserver
- HTTP and XML API commands
- E-mail alarms, SMTP, SNMP
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- TC Monitor is remote monitoring software that collects data and controls your TCG (GSM) and TCW (Ethernet) Teracom I/O modules
- User-friendly WEB interface for easy configuration and control
- Free version let monitor up to 10 items
- The monitored parameters can be sensors, digital and analog inputs and relay outputs
- Graphical and Data dashboards for better visualization
- TC Monitor allows flexible administration of user accounts
- Easy access to the raw data tables, export in .csv format
- Alarm notifications
- User activities log
- Ethernet connection
- Digital inputs: 2
- Relay outputs: 2 (NO/NC)
- Webserver
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- Molded epoxy resin protects against aggressive environmental factors
- Primary current: 60...160 A or 200...320 A
- Secondary current: 1 A or 5 A
- Hole diameter: 30 mm or 50 mm
- Hole depth: 50 mm or 40 mm
- Accuracy class: 1
Room thermostat, temperature switch with an electric socket RTBSB-001.401.
The RUVAC WH / WHU series pumps are high throughput, hermetically sealed, water-cooled roots blower pumps with high efficiency motors that provide optimum price-to-performance ratio. Both motors and oil reservoirs are water cooled thereby perfectly balancing the internal temperature management of the pumps.
RUVAC WHU pumps are equipped with a bypass line and may be operated at its maximum power from atmospheric pressure. The WHU is equipped with improved valve technology for maximum efficiency in short cycle operation. The integrated bypass line allows for the WHU pumps to be operated starting at atmospheric pressure while the unique control flap provides extreme contamination resistance.
- Output relay: SPDT / 3A / 250VAC
- Application: level sensing for solids and powder
- Speed: 1 RPM
- Supply: 24 VDC or 220 VAC
- Operating temperature: - 10...+ 70 °C
- Operating pressure: - 0,6...+ 0,6 bar
- Protection class: IP66
- LW and LE series of current transformers with a round hole for a cable
- Ranges of primary current from 50A up to 5000A
- Maximum operating voltage 0,72 kV
- Secondary current: 1A or 5A
- Accuracy classes: 0.2S, 0.2, 0.5S, 0.5, 1; 3
- Terminals of the secondary circuit are protected by cover that protects them against accidental contact
- Operating temperature: -10…+55 °C
The PD9W is an industrial RS-232 / RS-485 to WiFi and Ethernet converter.
- Communication interfaces: 1x RS485, 1 x RS232, 1x Ethernet and WiFi (802.11b/g/n)
- Modes: AP, STA, AP + STA, AP + LAN, AP + WAN, Route and Bridge
- Work modes: transparent transmission mode, serial port command mode, HTTP Client mode, Modbus TCP<=>Modbus RTU mode and AT command mode
- Configuration the parameters via the WEB server
- RS232 port for RTS/CTS signals
- Hardware Watchdog, Heartbeat
- Electrostatic protection 15 / 8 kV
- Power supply: 5…36 V dc
PD9-Modbus RS485 to Ethernet converter can realize bidirectional transparent transmission between RS485 and Ethernet. It carries ARM processor, low power, fast speed, high stability. Via web-page or software, Rs-485 to Ethernet Converter can realize serial data and TCP/IP data package transparent transmission.
- Communication interfaces: 1x RS485, 1x Ethernet WAN/LAN
- Easy configuration the parameters via the webpage or set-up software
- Compact size, DIN rail mount
- Working mode: TCP server, TCP client, UDP server, UDP client
- Modbus RTU to TCP conversion, Modbus Polling
- DHCP support, IP dynamic or static
- Watchdog function
- Working temperature: -40…85°C
- Power supply: 5…36 V dc
- Connected to a liquid manometer, measure dynamic pressure in a pipe and determine its speed (0...85 m/s) and flow m3/h
- The Pitot tube S is more sensitive to alignment errors than the Pitot tube L.
- Introduced perpendicularly in the pipe
- Particularly adapted for measurement in warm air, charged with particles and for high speed
- With integrated K type thermocouple
- Accuracy: 1 %
- Coefficient: 0,84 ± 0,01
- Static pressure: Atmospheric
- Temperature of use: 0…1000 °C
- Digital input: 4 ch. pulse
- Independent modes: OPEN / CLOSED (“Dry contact”) and COUNTER (S0 standard)
- Output: RS-485 MODBUS RTU interface
- Non-volatile memory for counters storage and settings
- Galvanically isolated inputs
- DIN rail mounting
- Protection class: IP40 (connections IP20)
- Operating temperature range: -20…+60 °C
- Power supply: 5…28 VDC
- Designed to measure the moisture of wood, sawdust, shavings, chips, straws and hay
- Moisture measurement method: resistive
- Sawdust moisture range: 8...30 %
- Hay moisture range: 8...25 %
- Sample size: 120 cm3
- Sample compression pressure: 0,2 MPa
- Portable wood moisture meter WTR-1E (needle), designed for moisture measurement from 6 to 100 %
- Designed to measure the moisture of wood, sawdust, scobs, shavings, slivers
- Moisture measurement method: resistive
- Moisture measurement range: 8...50 %
- Step value: 0,1 %
- Sample size: 120 cm3
- Sample compression pressure: 0,2 MPa
- Display: LCD
- Supply: 12 V battery
- Modern SCADA system
- Free license allows to work with up to 50 objects (each having 10 variables / tags / atoms)
- Free license supports only one chosen driver (i.e. Modbus)
- Hardware-independent, communicates with all major industry-standard
- Mobile application (in full version)
- 25 year experience in the marketplace - developed by 7-Technologies which belongs to Schneider Electric
- Up to 60 logical channels for data logging (max. up to 8 analog channels)
- Inputs:
- Measuring programmable: 0, 4 or 8
- Binary: 2 or 6
- Modbus RTU Client: 10 devices, 10 registers each
- Outputs:
- Relay: 2, 6 or 8
- Analog 0 / 4...20 mA: 0, 4 or 8
- Supplying output for external devices: 24V d.c. / 30 mA
- Communication interfaces:
- RS-485 MODBUS (Client and Server)
- Ethernet: MODBUS TCP/IP, Webserver (www), FTP
- USB Host 2.0
- Screen: Graphical color display LCD TFT 3.5”
- Internal memory 8 GB for Archiving of measured parameters
- Visualization of measurements in digital form, analog indicators, line charts, bargraphs
- Advanced mathematical functions on measured values
- Archiving and visualization of measuring data transmitted to KD6 from external devices via RS-485 MODBUS
- Settings secured with access password
- PC software for easier setup
- Protection class: IP65 (front)
- Operating temperature: -10...55 °C
- Supply: 85...253 V a.c., 90...300 V d.c. or 20...60 V d.c.
- Measurement channels: up to 24
- Analog inputs: 12
- Relay outputs: 6 or 32
- Analog outputs: 4 or 8
- Digital outputs: RS-232, RS-485, USB
- Screen: touchscreen LCD TFT 5.7”
- Memory: CompactFlash memory card, up to 4 GB
- Visualization of measurements in digital form, analog indicators, diagrams, bargraphs
- Ethernet, Webserver, FTP server, Modbus Slave TCP/IP
- Diversified users’ access rights
- PC software
- Protection class: IP65 (front)
- Operating temperature: 0...55 °C
- Supply: 230 VAC
- SF6 gas monitor for high and medium voltage switchgear
- Measurement range: 0...60 kg SF6/m3
- Output signal: current pulses onto supply current, current loop
- Media temperature: -40...+70 °C
- Protection class: IP65
- Shock proof, suitable for outdoor usage, compact
- SF6 gas monitor for high voltage switchgear
- Four versions: 1 / 2 / 3 / 4 stages (8716 / 8726/ 8736 / 8746)
- Measurement range: 0...1.1 MPa
- Output signal: floating change-over contact (SPDT)
- Switch point: factory calibrated
- Media temperature: -40...+80 °C
- Protection class: IP67
- Independent, galvanically separated circuits
- Rated load: 20...10 000 kg (chosen from list)
- Output: 2 mV/V
- Connection: 3 / 6 m cable, 4-wire
- Operating temperature: -35...+65 °C
- Supply: 10 VDC
- Protection class: IP66 / IP67
- Used for measuring range extension and conform to EN 60051 standard
- Can be used in various measuring systems
- Shunts are selected by nominal current (1 – 15000 A)
- Input: 4x RTD (Pt100, Pt1000, Ni100, Ni1000), resistive and potentiometer configurable input
- Output: RS-485 Master/Slave and RS-232 (MODBUS RTU/ASCII protocol)
- 2000 VAC galvanic isolation
- High accuracy
- EMC compliance - CE symbol
- Mounting on DIN rail - EN-50022 complience
- Supply voltage: 10...30 VDC
- Ambient temperature: -10...+60°C
- Signal splitter DAT5022
- Configurable with switches on body
- 3-way galvanic isolation (2000 VAC)
- Input: 4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V
- Output: 2 X (4...20mA, 0...20mA, 0...10V, 0...5V, 2...10V, 1...5V)
- Power Supply: 18...32 VDC. Reverse polarity protection 60 VDC
- Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
- Environment: -20...+70 °C / (non-condensing) 0-90%
- Housing: Self-extinguishing material
- EMC
- Immunity: EN 61000-6-2
- Emission: EN 61000-6-4
The P17 transducer, supplied from a current loop, converts the signal from temperature sensors or a standard voltage signal into a 4...20 mA current.
- Ethernet 10/100 Base-T Modbus TCP interface (RJ-45 connector)
- Configurable using webserver
- RS-485 (Modbus RTU Master)
- Distance up to 1200 m, up to 32 modules
- LED indication
- Galvanic isolation in all ways (1500 VAC)
- EMC compliance
- Mounting on DIN rail - EN-50022 compliance
- Modbus Slave over RS-485
- Modbus RTU / Modbus ASCII protocols
- Communication parameters configurable by dip-switches
- Watch-dog alarm
- Remotely configurable
- 3-way galvanic isolation (1500 VAC)
- High accuracy
- Mounting on DIN rail - EN-50022 compliance
- Ethernet 10/100 Base-T interface
- Modbus TCP server
- Webserver for configuration of device and representation of actual input values
- Galvanic isolation on all the ways (1500 VAC)
- Remotely configured
- LED indication
- EMC compliance
- DIN rail mounting
Tempmate-S1 data loggers are specially designed for temperature monitoring in any cold chain logistics. The automatically created PDF and CSV report, containing detailed information such as data curve, every single measurement as a table and statistical information.
Ex Tax: 24.70 €
They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.
- Single-phase power controller (phase angle load control)
- Control input: DC voltage 0...10 V DC (RSR92-..V..) or current 4...20 mA (RSR92-..I..)
- SCR output (thyristors)
- Load current 25...80 A
- Max. load voltage 280, 530 V AC (single-phase)
- Dielectric strength 4 000 Vrms (opto-isolation)
- MOV protection (built-in varistor)
- Mounting on panel or on heatsinks
- Recognitions, certifications, directives: RoHS, REACH, CE, EAC
- Self-operating signal lamps (optic signaling of AC/DC voltage presence in 1-phase network via lighting of one non-replaceable LED)
- LED colors: green, red, yellow
- Cover - modular, width 17,5 mm
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Applications: in low-voltage systems (130…260 V)
- Compliance with standards: EN 62094-1, EN 61000-4-2, 3, 4, 5, 6, 11
- Recognitions, certifications, directives: RoHS, CE, EAC, UKCA
Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.
- Temperature measurement range*: -200…+100 °C
- Relative humidity measurement range*: 0…100 %
- Ambient light measurement range*: 0…10000 lx
- Local storage capacity*: 24200 values for Temperature, Humidity and Light
- Shelf-Life:
- Lithium Battery devices: 12 months (possibility to charge)
- Non-Lithium Battery devices: 6 months (possibility to charge)
- External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
- Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
- Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
- Recording Duration:
- Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
- Certifications: CE, EN12830, EMC, RoHS, FCC
- Connectivity: LTE 4G cat 1 with 2G Fallback
- Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
- Location: LBS - GSM Localization
- Recommended Storage Temperature: -15…+25 °C
- Sludge and sand detection
- Oil on water surface detection
- Designed for usage in separators, basins and tanks
- Easy to install, does not need calibration
- Reliable long-term se in harshest conditions
- Acoustic and visual alarms
- 2 switch outputs
- ATEX certified
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz
- SandSet-1000 is designed for sludge and sand detection in separators, basins and tanks
- Easy to install, does not need calibration
- Reliable long-term se in harshest conditions
- Acoustic and visual alarms
- 2 switch outputs or output to LabkoNet remote monitoring system
- Ultrasonic sensor SET/S, 5 meter cable
- ATEX certified
- Wall-mounted, IP67
- Supply: 230 VAC, 50/60 Hz
- Relay output
- Smoke sensitivity complies with EN 54-7:2000+ A1:2002
- Digital signal processing
- Very low current consumption
- Excellent long-term stability
- LED indication
- Supply: 10...30 VDC
- Warranty: 3 years