This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Search

Search Criteria

Products meeting the search criteria

Show:
Sort By:
  • Incremental encoder output: A, B   /   A, B, Z   /   A, /A, B, /B   /   A, B, Z, /A, /B, /Z
  • Resolution: 5 / 10 / 25 / 50 μm
  • Portable reference point
  • Stroke values up to 2000 mm
  • Vibration-resistant
  • Cable length: 3 / 5 / 8 / 10 m (optionally 5...50 m)
  • Supply: 10...30 VDC / 5 VDC
  • Operating temperature: -25...+85 °C
  • Protection class: IP65

Linear encoder MLS110. With cable connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS110. With spiral connection.

 

Technical specifications

  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS120.

Technical specifications

  • Casing integrated into slider
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS130. Very small size.

 

Technical specifications

  • Very small measuring head (in metal enclosure)
  • Wide range of available resolution (up to 1 µm)
  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection and slider joints.

 

Technical specifications

  • Protection class IP67
  • Twin sliders
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC

Linear encoder MLS210. With spiral connection.

 

Technical specifications

  • Protection class IP67
  • Resistant to humidity
  • Aluminum casing
  • Incremental outputs A, /A, B, /B and Z
  • Output “push-pull”, TTL or RS-422
  • Supply 5 VDC or 10...30 VDC
  • SpotScan is a linear scanning add-on for RAYTEK, IRCON noncontact IR thermometers ENDURANCE, Marathon MM, Modline 5 and Modline 7

  • SpotScan is designed to broaden the capabilities of noncontact IR thermometers while scanning measured surface linearly thus measuring wider than one dot target area

The enLink Status-VC transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • 0…20 mA, 0…10 V or resistance input
  • 12 bit resolution
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
  • Configuration via USB cable / downlink
  • Case IP40 protection (IP 67 on request)

The enLink IAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (0.1, 0.3, 0.5, 1.0, 2.5, 5.0 & 10), Barometric pressure, Sound*, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Distinguishes between vaping and smoke and counts the number of detections
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours or adaptive (triggered by vape or smoke)
  • Power suplly: 12…24V V DC, 0.15 Amp (max)
  • Configuration via USB cable / downlink
  • Operating Temp. / Humidity: 0…40 °C / 0…95 % RH

The enLink OAQ Vape transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • Sensed parameters: Temperature, Relative humidity, VOC, CO2, Particles PM (1.0, 2.5, 4.0 & 10), Barometric pressure, Ozone**, Arsine*, Formaldehyde*, Methyl Mercaptan*, Chlorine*, Carbon Monoxide*, Ethylene Oxide*, Hydrogen*, Hydrogen Sulphide*, Hydrogen Cyanide*, Ammonia*, Nitrogen Dioxide*, Oxygen*, Odorous gases*, Phosphine*, Sulphur Dioxide*
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours
  • Power supply: 12…24V V DC, 0.15 Amp (max) / 4 x Li-SOCl2 (3.6V) AA / external solar panel
  • Configuration via USB cable / downlink
  • IP rating: IP42 (conformally coated electronics), do not expose to direct sunlight
  • Operating Temp. / Humidity: -10…40 °C / 0…95 % RH (be kondensacijos)

The enLink Status-P transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • 3 channels pulse counter (S0 standard) and monitor of state (open / closed)
  • With the transmit on Change of State enabled the unit operates as a standard pulse counter and also transmits a message when the state of the input changes from closed to open or open to closed
  • The pulse counts for each channel are written to memory every 5 – 10 minutes
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours or adaptive (triggered by change of state)
  • 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
  • Configuration via USB cable / downlink
  • Case IP40 protection (IP 67 on request)

The enLink Status-T transmits data using long range LoRa wireless which easily integrates with cloud services or on-site Systems.

  • External sensor measurement range: -55…+125 °C
    • Accuracy: ± 0.5 °C (-10…+85 °C)
  • Up to two probes (cable length: 1 m, others on request)
  • Communication: LoRaWAN; frequency range: 863-870 MHz; up to 16 km range
  • Measurement sending interval: 30 s to 3 hours or adaptive (triggered by alarm)
  • 2 x Li-SOCl2 (3.6V) AA sized batteries ensure 3+ years of operation
  • Configuration via USB cable / downlink
  • Each sensor can be programmed individually for different alarm type: No alarming, High threshold alarm, Low threshold alarm, In band alarm, Out of band alarm
  • Each alarm type has an individual alarm status message with the following parameters: Alarm status, Total number of alarm activations, Alarm duration
  • Case IP40 protection (IP 67 on request)

The Wx9xx series of sensors from COMET SYSTEM enables accurate measurement of temperature, relative humidity, and atmospheric pressure, with data transmitted via the low-power LoRaWAN network. This technology allows data to be sent to a cloud storage, where users can easily view both current and historical values through a standard web browser. Each sensor has an LCD display showing the measured value and battery status.

  • Possibility to connect Pt1000 sensors
  • Covers up to 15 km in rural areas and 2…5 km in urban areas
  • Work with Comet System LoRaWAN gateway SP041
  • Battery life: from 1 to 10 years depending on transmission time and environment temperature
  • Unlimited space for data in cloud
  • Alarm: email and app notification
  • Mobile applications for Android and iOS
  • The battery or mains powered wireless M-Bus gateway B4 is highly configurable plug-and-play device used for collecting data from Wireless M-Bus meters / sensors and transmitting the data using LTE CAT-M1 and MQTT protocol
  • Long range and high sensitivity internal (or external mounted) antennas
  • To maximize the battery lifetime possible configuration to listen number of minutes, specific time during day, specific days and limit number of packets stored per meter / week / day / hour
  • The gateway firmware can be upgraded remotely using MQTT
  • B4 series gateway can be used with Lansen R4 series repeaters and transmit additional information (see datasheet)
  • Configuration can be done with: Lansen Wireless M-BUS programming dongle together with our program, Lansen Configurator, other wireless M-BUS transmitters or remotely using the MQTT protocol
  • Possible to activate 128 bit AES-key encryption
  • Gateway suited for harsh environments, operating temperature: -30…+85 °C, protection class: IP40, IP65 and IP67
  • IoT LTE M SIM card needed (acquired separately)
  • Long-lasting stainless steel screw electrodes
  • Measurement range: 7...20 % (-40...+125 °C)
  • Resolution: 0,1 %
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Electrode cable: FEP, -50...+200 °C, 5/10/15 m
  • Timber temperature compensation
  • Electrode length: 15 / 25 mm
  • Supply: 11...30 VDC
  • Protection class: IP68
  • Wide gap between the two parts of sensor
  • Protection class: IP65
  • Max switching voltage: 100 V
  • Max switching current: 0,5 A
  • Cable length: 0,45 m
  • Warranty: 3 years
  • Measurement range: -40...+150 °C, -1...60 bar
  • Temperature measurement accuracy: ± 1,3 °C
  • Pressure measurement accuracy: ±0,5 % of full scale
  • Operating temperature: -20...+50 °C
  • Overload: 65 bar
  • Two valve system
  • Android / iOS app for communication with the device (via Bluetooth Low Energy interface)
  • 124 refrigerant gases
Non-reversible temperature labels, 10 temperature ranges.  A °F°C 10440  10842 11144 11546 12049 12954 14060 14462 14965 16071  B °F°C  17177 18082 19088 19993 21099 ..
  • Display: 4 or 5-digit, 4.2mm
  • Reset function
  • The system is designed to monitor pressure and flow rate of medical gasses
  • Information is gathered from pressure and flow rate transmitters and conveyed into the controllers which transfer the data into a PC via RS-485 interface (MODBUS protocol)
  • SCADA software enables the visualization of the process
  • Data is logged annd represented on the computer screen
  • Values can also be represented in graphs

The device is designed to measure ambient air pollution by detecting concentration and distribution of particles.

  • Inputs: Pt100, Pt1000, 0…4000 Ω, TC (E, J, K, N, R, S), -75…310 mV, -10…10 V, -24…24 mA, potentiometer
  • Relay output: 1 x NO contact, load-carrying capacity 6A / 250 V AC.; 6A / 30V DC
  • Digital output: RS-485 / MODBUS RTU
  • Auxiliary supply: 24 V DC / 24 mA
  • Mathematical functions for converting the measured value
  • Two-line LCD display (1-row 6 digits, 2-row 5 digits)
  • Protection grade: frontal side – IP65 / from terminal side – IP10
  • Operating temperature: -20...23...60 °C
  • Power supply: 40… 253 VAC / 20…300 V D

Digital meters – bargraphs NA3, NA5, NA6,measurement of DC voltage, current, resistance and temperature measurement (with thermal sensors J, K, N, E, R, S, T, Pt100, Pt500, Pt1000).

  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...5 % vol) CH4
  • Resolution 0,1 % LEL (50 ppm) CH4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 / 50 % LEL CH4
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL CH4
  • Resolution 0,1 % LEL CH4
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 20 / 50 % LEL CH4
  • Visual and acoustic alarms
  • Stable long-life metal-oxide gas sensor
  • Range 0...100 % LEL (0...5 % vol) CH4
  • Resolution 0,1 % LEL (50 ppm) CH4
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Metal-oxide gas sensor
  • Range: 0...100% LEL (0...5 %) CH4
  • Resolution: 0,1 % LEL (50 ppm) CH4
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -40...+70 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Micro-manometer HP (differential, liquid) HP5, HP10, HP15.

Micro-manometer MG (differential, liquid) MG20, MG40, MG50, MG60, MG80, MG100.

Micro-manometer TJ (differential, liquid) TJ100, TJ150, TJ300, TJ600, TJ1000.

Micro-manometer TX (differential, liquid) TX25, TX50, TX75.

♦ Positive, negative and differential pressure measurement
♦ Air speed measurement
♦ Automatic zero find function
♦ Measured value hold
♦ Minimal and maximal value detection
♦ Measurement unit option

Micro-manometric fluid AWS10, for filling.

  • Range: -250...2550 Pa
  • Maximal overpressure: 30 kPa
  • Accuracy: ±1,4 %
  • Pressure and air flow measurements from air diffusers and valves
  • Data can be uploaded on your computer for visualization and further analysis
  • Over 700 programmed valve types
  • Mediums: air and non-aggressive gases
  • Operating temperature: -10... +50 °C
  • Connection: ø 5 mm pressure hoses
  • Can be used with Pitot tube
  • 5 year warranty
  • Included: calibration certificate, 2 x 2 m PVC hoses
  • Temperature sensor AUREGIS TJ-2 with mineral insulation is inextricably connected to the cable
  • It is designed for temperature measurement from -50°C to 550°C for RTD sensors Pt100, Pt1000 and from -50°C to 1150°C - for thermocouples
  • Various sizes are available depending on customer requirements and drawings

TSM400-4-CP is a multi parameters sensor that supports MODBUS RTU protocol over the RS-485 interface. The sensor measures barometric pressure and CO2 concentration.. Suitable for environmental quality monitoring, indoor air, smart ventilation systems, restaurants and breweries CO2 level and CO2 leakage control.

  • Changeable bitrate and other communication parameters
  • Non-volatile memory for all setting
  • CO2 measurements range: 400…5000 ppm
  • Accuracy: ± (40 ppm + 5 %)
  • Resolution: 1 ppm
  • Calibration: Automatic, if the sensor is exposed to fresh air for more than 30 minutes
  • Pressure measurements range: 10…1200 hPa
  • Accuracy (min): ±1.5 (25°C, 750 hPa)
  • Accuracy (max): ±2.5 (-20 °C to + 85 °C, 300…1100 hPa)
  • Resolution: 1 hPa
  • Operating temperature range: -20…+60°C
  • Operating relative humidity range: 5…95% (non-condensing)
  • Ingress protection: IP20
  • Operating voltage range: 4,5…26 VDC
  • Input: Modbus RTU – RS-485
  • Output: 4-channel SPST relay contacts
  • Rated relay load: 3 A at 250 Vac; 3 A at 30 Vdc
  • Non-volatile memory to retain and restore relay states following power outages
  • Watchdog functionality for communication loss
  • Operating temperature / humidity: -20…+60 °C / 10…90 % (non-condensing)
  • DIN rail mounting
  • Power supply: 5…28 Vdc
  • Warranty: 3 years
  • The module setting can be done through USB or one of the RS-485 (master/slave) interface using the available for free eCon program
  • Possibility of connection via internal RS-485 port in order to increase no of analog outputs in network
  • Master Modbus function dedicated to read out data from other RS-485 devices and to scale analog value.
  • Slave Modbus function to set the signal on analog outputs
  • Possibility of configuration through USB without power supply
  • 4 analog inputs (standard signals, RTD, thermocouple)
  • RS-485 Modbus output (Slave mode)
  • 2 alarm outputs
  • Galvanic isolation of inputs (2 from other 2)
  • Programmable individual characteristics, mathematical functions
  • Programmable time counters
  • Rail-mounted

2-channel binary input converter SM3 with RS-485/232 interface. Modbus RTU and ASCII.

8 binary output converter SM4 with RS-485/232 interface. Modbus RTU and ASCII.

8-channel binary input converter SM5 with RS-485/232 interface. Modbus RTU and ASCII.

  • Moisture reading range:
    • 4…18 % for Lint cotton
    • 6…20 % for Seed cotton
    • 12…30 % for Wool
    • 6…25 % Viscose / Rayon
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app. timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 20,40 x 7.24 x 4.06 cm
  • Weight: meter only: 218 gr
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
  • Moisture reading range:
    • Hay: 6…40 %
    • Hops: 8…23 % (FX-30)
    • Hemp: 7…34 % (FX-30)
    • Tobacco: 8…37 % (FX-30)
    • Brazil Nuts: 6…25 % (FX-30)
    • Dates: 6…25 % (FX-30)
  • Large, custom display with auto backlight and modern light case for comfort use
  • On-screen statistics for up to 100 readings saved to the meter (High, Low, Average, Standard Deviation)
  • Bluetooth® connectivity to EDGE® app (FX-30). timestamp and geotag, data export to .csv format, save unlimited readings, customize LED ranges
  • Alarm set point - alerts to user-selected moisture level (Color-coded LEDs alerts – adjustable through EDGE® app FX-30)
  • Internal calibration check
  • “Low Batt” warning with audio
  • Auto off timer.  Set to 1m, 4m, or 10m
  • Compatible with existing Delmhorst prods and electrodes
  • Power: 2x AA Alkaline battery (Working hours: 125…150)
  • Temperature Correction Range: -18…+124 °C
  • QR code on meter for easy access to support materials and meter registration
  • Size: meter only 20,40 x 7,24 x 4,06 cm
  • Weight: meter only: 218 gm
  • 2-year warranty on manufacturer’s defects. Bonus warranty with on-line registration
Loading...