Temperature transmitter DAT1010 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm) ir voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1015 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1066 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (4...20 mA). With galvanic isoliation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
Temperature transmitter DAT1135 is designed for RTD (Pt100, Pt1000, Ni100, Ni1000, Ohm), thermocouple (J, K, S, R, B, E, T, N) and voltage (mV) signal conversion to analog (0...10 V). With galvanic isolation (1500 VAC).
The transmitter is mounted into a B-type head. Programming can be done in our company.
- Input (configurable): TC, RTD, mV, resistance and potentiometer
- Output: Modbus RTU / ASCII Slave device over RS-485
- 1500 Vac 3-ways Galvanic Isolation
- High accuracy
- Remotely configurable over RS-485
- EMC compliance (CE mark)
- Mounting in B-type head
- Easy implementation in existing PLCs and SCADA systems
- Operating temperature: -40...+85°C
- Supply voltage: 18...30 VDC
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
Temperature transducer with 0...10 V output is built in a durable watertight case. Built-in precise temperature sensor. Output temperature range is user adjustable. Calibration certificate is included.
Temperature transducer with 0...10 V output is built in a durable watertight case. To be used with an external Pt1000 temperature probe. Output temperature range is user adjustable. Calibration certificate is included.
- Input: RTD: Pt100 (3-wire), TC: J, K N
- Output: IO-Link
- Configuration: via IO-Link
- Operating temperature: -20...+80 °C
- Supply 24 VDC
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
- Measures ambient temperature, humidity, pressure
- Calculates dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy
- Measuring ranges: -30...+80 °C, 0...100 %RH, 600...1100 hPa
- Output: Ethernet
- Optional connection to WiFi network via tiny wireless router TL-WIFI
- Webserver
- Measurement interval: 2 s
- Alarm protocols: E-mail, SNMP Trap, Syslog
- Supply: 9...30 VDC
- Calibration certificate included
- Protection class: IP30
- Temperature measurement range: -20...+60 °C
- Humidity measurement range: 0...100 %RH
- Pressure measurement range: 600...1100 hPa
- CO2 concentration measurement range: 0...5000 ppm
- Memory: up to 500,000 values in non-cyclic mode and 350 000 in cyclic mode
- Logging interval: 1 s...24 h
- Internal sensors
- Local alarms via LED indication, on LCD screen and acoustically by built-in beeper
- Data can be transferred to PC via USB-C interface
- Calibration certificate included
- Ambient temperature: -20...+60 °C
- Supply: 5200 mAh LiIon battery
- Protection class: IP20
- Warranty: 3 years
Temperature, humidity, pressure, CO2 regulators, 3 binary inputs, RS-485, RS-232 interfaces, Ethernet and 2 relay outputs.
Temperature, humidity, pressure, CO2 transducers Pxxxx, Txx1x. LCD display.
- Flow and temperature sensor for liquids in pipes
- Output: 1 x 4...20 mA, 1 x PNP / 2 x PNP
- Flow measurement range: 1...150 cm/s (water)
- Temperature measurement switching points: 15, 30, 45, 60, 75 °C
- Flow rate measurement is shown in a bar graph by five green LEDs
- Settings provided by magnetic pen
- Stainless steel case
- Supply: 12...34 VDC
- Ambient temperature: -20...+80 °C
- Protection class: IP67 / IP68
- Wide temperature range: -10...+1200 °C
- 320 x 240 and 640 x 480 infrared resolution
- 9 or 60 Hz models available
- Sighting: IR-Fusion technology (thermal and visible sighting) for easy alignment and added detail on blended images
- Remote motorized focus
- Multiple field interchangeable lens options available
- GigE Vision interface
- LAN/Ethernet with PoE for communication with the thermal imager provides access to Ethernet, Web server and ThermoView Software
- I/O alarming capabilities
- ThermoView software for industrial automation applications
- Ambient temperatures to 200 °C with high temperature enclosure
- Air purge and accessories available
- Rugged housing, IP67 rated
- Air velocity, airflow and temperature measurement
- Air flow measurement with a cone
- Automatic average
- Display of minimum and maximum values, hold function
- Adjustable auto shut-off
- Detection of flow direction
- Selection of units
- Supplied with calibration certificate
- Display of minimum and maximum values, hold function
- Adjustable auto shut-off
- Automatic average
- Selection of units
- Detection of flow direction (LV 110/LV 117)
- Supplied with calibration certificate
- Air flow measurement with a cone (LV 110/LV 117)
- Thermocouple commutatotr TK with cold junction compensation for thermocouple measurement output (in turns) to one output
- Connecting that output to measuring device or indicator enables the monitoring of thermocouples in turns
The sensor consists of a replaceable insert, a ceramic protective tube (thermowell) and an aluminium connection head (depends on model) where a programmable temperature transmitter with 4-20 mA output can be installed.
- Temperature measuring range: 0… +1800 °C
- Usable areas: Blast furnaces, regenerating air heaters, industrial heating installations, heat generation
- Standard protection tube material: mullite C610 (Al2O3 60%), Ceramic C799 (99.7% Al2O3)
- Gastight process connection: (to 0.1 MPa / 1 bar)
- Optionally the head can be installed with a local temperature display (DANWdie-LED)
- ATEX and EAC Ex versions
- For specific model design please look picture below ↓: TT438, TT440, TT441, TT442, TT443, TT444
- Measurement range: -40…+180 °C
- Type: J / K / N / T / E
- Self-adhesive tape
- Thermocouple tolerance (accuracy), cable length and insulation can be chosen by demand (see datasheet)
- Optional: temperature transducer (4...20 mA / 0...10 V / HART / Profibus PA / Fieldbus)
- Optional: connector
- Thermocouple with small measurement tip AUREGIS TJ-K for temperature measurements from -75 °C to +250 °C, fast measurement
- Sensor type: thermocouple K (NiCr-NiAl), class 2
- Measurement range: -75 °C to +250 °C
- Connection: mini connector
Capillary thermometer TXC is designed for temperature measurement from -200 to +800 °C. Capillary parameters, diameter and length of measuring element, measurement dial range, process connection, contact type and other parameters must be chosen from the catalogue.
Stainless steel thermometer TXR is designed for temperature measurement from -200 to +800 °C. Diameter and length of measuring element, measurement dial range, process connection, contact type and other parameters must be chosen from the catalogue.
Temperature relay, mechanical thermostat ATR83 with pipe-mounting for temperature control.
Temperature relay, mechanical thermostat JTF-1 for frost protection.
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Versions according to PN-79/M-53857/05
- Threads for thermometer: metric M12x1.5, M14x1.5
- Lengths: according to customer's specification
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Bore diameters: Ø3.5 mm, Ø7 mm
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Optional designs per DIN 43772 ( form 4 )
- Other materials, threads and dimensions
- Process flanges according to: EN 1092-1, DIN 2527, ASME B 16.5
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT or other
- Immersion lengths: from 50 mm to 2500 mm (according to customer's specification)
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti )
- Dimension tolerance according to DIN ISO 2768
- Protection tube coated by layer of CrC to increase abrasion resistance
- Protection tube coated by teflon® PTFE to increase corrosion resistance
- Other materials, threads, flanges and dimensions
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Drilled (solid machined) thermowells, designed to be weld-in into pipelines and boilers
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Instrument threads (female thread): G1/2", M20x1.5, 1/2"NPT and other
- Process threads (male thread): G1/2", M20x1.5, 1/2"NPT and other
- Lengths: according to customer's specification
- Dimension tolerances according to DIN ISO 2768
- Maximal process pressure and temperature depends on thermowell dimension and its material
- Available materials: 1.4401 ( AISI316 ), 1.4404 ( AISI316L ), 1.4541 ( AISI321 ), 1.4571 ( AISI316Ti ), 1.5415 ( 16Mo3 ), 1.7335 ( 15HM ), 1.7380 ( 10H2M )
- Versions according to DIN 43772
- Other materials, threads and dimensions
- Designed to measure the thickness of non-magnetic layers
- Can be used for construction, ships, tanks, piping, boilers, vehicles protective layer quality control
- High accuracy in wide temperature (with compensation) range using the same probe
- Fit for work outside
- Certificate of calibration included
- Three-color numerical display DL21 is designed to indicate various parameters (temperature, humidity, etc.) from external devices via RS-485
- Can be used in offices, industrial and communal buildings
- Indicator color is programmable (green, red and yellow)
- Programming is done via RS-485 port
- Can work in master and slave modes
They are used to regulate the power delivered to the receiver, where this power is proportional to the input control signal. They are used in automation control systems where smooth control of receiver power is required for resistive or resistive-inductive loads. Typical applications for power controllers: heaters, industrial furnaces (annealing, quenching, drying, etc.), dryers, plastics processing equipment, industrial sealing machines, glass production industry, industrial heating systems (matting and lining of pipelines), load transformers.
- Three-phase power controller (phase angle load control)
- Control input: DC voltage 0...10 V DC or current 4...20 mA
- SCR output (thyristors)
- Load current 25...80 A
- Max. load voltage 530 V AC (three-phase)
- Dielectric strength 4 000 Vrms (opto-isolation)
- MOV protection (built-in varistor)
- Mounting on heatsinks
- Recognitions, certifications, directives: RoHS, REACH, CE, EAC
- Self-operating signal lamps (optic signaling of AC/DC voltage presence in 3-phase network – 3(N) 400 / 230 V via lighting of one non-replaceable LED)
- LED colors: green, red, (red, yellow, green)
- Cover - modular, width 17,5 mm
- Direct mounting on 35 mm rail mount acc. to EN 60715
- Applications: in low-voltage systems (400 / 230 V)
- Compliance with standards: EN 62094-1, EN 61000-4-2, 3, 4, 5, 6, 11
- Recognitions, certifications, directives: RoHS, CE, EAC, UKCA
- Wood moisture transmitter KP (0...20 mA), made by Tanel (Poland)
- Output signal 0...20 mA which corresponds to range 0...60 %; practically used range is 8...60 %
- Display: LCD 8 digits, 7 mm; LED 6 digits, 7 mm.
- Calculation frequency: Min. 30 Hz / 20 Hz (type 3), max. 7,5 kHz
Totalizing counter Type 634 – “MINI I”.
- Display 6 or 7 digit, 4mm
- Protection class IP65
- Transducer for AC current and voltage into DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- The construction of the transducer ensures accurate and fast signal transformation
- Fast and easy installation on rail, or onto a wall or in panel using holder
- Transducer for DC current and voltage into other DC signal (1 output)
- Input, output and supply of the transducer are galvanic insolated
- Solves grounding problem in meshed signal networks
- User selectable type and range of input