- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...100 ppm, 0...2000 ppm H2S
- Resolution: 1 ppm H2S
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL CH4
- Resolution: 0,1 / 1 % LEL CH4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0…250 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+50 °C; 15…90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life optical NDIR sensor
- Range: 0…1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...25 % vol O2
- Resolution: 0,01 % vol O2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 5…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Highly sensitive Photo Ionization Detector (PID) sensor
- Detectable gases: VOCs (acetone, ethanol, toluene, xylene etc.)
- Default calibration: Isobutylene
- Range: 0…40 / 0…200 ppm isobutylene
- Resolution: 0,01 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+65 °C; 0…95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life metal-oxide sensor
- Detectable gases: acetone, ethanol, toluene, xylene etc.
- Default calibration: toluene
- Range: 0...1000 ppm (toxic range) / 0...100% LEL (flammable range)
- Resolution: 1 ppm for toxic ranges / 0,1 % LEL for flammable range
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
You can use it for limit sensing of liquid levels in non-conductive tanks (through the non-conductive wall of a vessel or pipeline).
The sensor is equipped with a high-frequency technology, enabling reliable function even in case of adhering conductive media.
Miniature performance in a flexible housing, optional installation on slightly curving surfaces.
Attached using self-adhesive a layer or special fastening bands.
Configuration and setup using "programming" cable or magnetic pen.
LED status indication.
Vertical, stainless steel, float level sensor with float protection against mechanical impact, designed for level control.
- Material of float: stainless steel AISI 316 SS
- Max. temperature: -30...+105 °C
- Switch rating: 50 VA
- Switching voltage: 230 AC / DC
- Float level switch AUREGIS LJ-VT with extension and temperature for level and temperature measurement
- Float level switches have an integrated temperature sensor Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Measured temperature: Pt100, Pt1000, Ni100, Ni120, Ni1000, NTC or PTC
- Float level switches AUREGIS LJ-V with an extension for level control
- Operating temperature: -30...+130°C
- Protection class: IP65
Thermal mass flow sensor for compressed air and gases VA 500
- 4...20 mA, pulse and a Modbus RTU (RS 485) interface as standard
- Optional: Interfaces such as Modbus TCP (Ethernet), PoE, M-Bus
- Optional: Bi-directional measurement
- Pressure tight up to 50 bar
- Temperature range up to 110 °C
- Protection class IP65
- Suitable for gas velocities up to 224 Nm/s
- Integrated display for showing the measured values
- Can be used from 1/2" up to 40", larger diameters on request
- Easy installation under pressure
- Settings can be changed via the display
- Main counter reading can be reset via the display
- Flow monitor for liquid media in the range of 4…400 cm/s with analog (4…20 mA) and status output (PNP, NPN) for monitoring a flow threshold
- Ten LEDs indicate flow and contact closure
- Equipped with 2 control buttons for setting the switching point
- Available with 65 mm and 125 mm mounting depths
- Rugged design for industrial environments, IP67
- Calorimetric measuring principle
- Units freely selectable via keys at the display
- Display shows 2 values at the same time, twistable by 180 ° degree
- Integrated Modbus interface enables connection control systems, SCADA
- M-Bus (optional)
- Analog output 4...20 mA
- Pulse output (galvanic isolation)
- High measuring accuracy (ideal for leakage measurement)
- Flow sensor suitable for evaluation unit NLSW®45-6 and NLSW®45-6.1
- Thread: PG7, optional accessories available
- Material: stainless steel V4A
- Media temperature: optional up to 400°C
- Protection class sensor: IP50
- Insertion depth: 50 mm, 130 mm, 165 mm, 300 mm
- Compressive strength: 10 bar
- Applications of flue gas analyzer Si-Ca 130: for commercial and residential boilers and water heaters
- Detectable gases: O2, CO, CO2, NO, NOx
- Up to three gas sensors
- CO measurement up to 8000 ppm
- Other measurement parameters: flue temp., air temp., differential temp., pressure / draft, excess air, combustion efficiency, combustion efficiency (condensation)
- Color display screen with buttons
- Communication: Bluetooth (mobile App), remote printer
- Measurement storage: smartphone
- Predictive maintenance with estimated sensor life and calibration reminders
- Protection class: IP42
- Power supply: Rechargeable battery, Li-Ion 5100 mA/h 3.6 V (8 hours working time)
- Operating temperature: -5…+45 °C
- Sensor protection by pump stopping
Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.
Technical specifications
- One or more level control
- Switch output 2A, 250 VAC
- Probe supply from isolated ~12 V source
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.
Technical specifications
- One or more level control
- Switch outputs: switching + NO 2 A / 250 VAC
- Probe supply from isolated ~12 V source
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
- One or more level control
- Switch outputs: switching + 3 x NO 2 A / 250 VAC
- Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
- Supply: 230 VAC / 24 VAC
- One or two level control
- Switch outputs – switching + 5 x NO, 2A / 250 VAC
- Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
- Adjustable sensitivity
- Available modes – filling, draining, dry flow, overflow, two/three pump control and others
- Valve or gate control
- Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
- Mounted on standard rail (35 mm)
- Supply: 230 VAC / 24 VAC
The FPI 8237 IO-Link Flush Membrane pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel 1.4462. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.
- Measuring range: -0,5...0,5 to 0...100 bar
- Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN / Push-Pull configurable
- Accuracy at 25°C typically: ± 0.5 % FS typ.
- Measuring principle: Thin-film-on-steel
- Media temperature –10... +125 °C
- Ambient temperature: –10...+125 °C
- Protection class: IP65, IP67
- Applications: Hydraulics, Machine tools, Process technology, Food industry, Water treatment
The FPT 8236 pressure transmitter impresses with an absolutely smooth and robust flush-mounted measuring diaphragm made of corrosion-resistant duplex steel. Trafag’s proprietary thin-film-on-steel sensor technology ensures a wide temperature range and excellent long-term stability.
- Measuring range: 0.5...0.5 to 0...100 bar (-5...10 to 0...1500 psi)
- Output signal: 4...20 mA, 0...5 VDC, 1...6 VDC, 0...10 VDC, 0.5…4.5 VDC ratiometric
- Accuracy at 25°C typically: ± 0.5 % FS typ.
- Membrane in Duplex steel 1.4462
- Pressure connection: G1/2” male, flush membrane
- Media temperature –10... +125 °C
- Ambient temperature: –10...+125 °C
- Applications: Machine tools, Food Industry, Process technology, Water treatment, Hydraulics
The frame light barriers of FLB Series are used for the measurement of smallest unguided parts.
Frequency meters CA32, CA36, CA37, CA39, CA39L are designed for frequency measurement in electrical grid. Transducer signal is measured using magnetoelectric effect. Tropical version available.
- Frequency range: 45...55, 45...65, 48...52, 55...65, 360...440, 380...420 Hz
- Voltage range: 60,100, 110, 230, 240, 400, 415, 440, 500 ± 20%
- Accuracy class: 0,5
- Consumed power: =< 7 VA
- Protection class: IP52 or IP65
- Standards conformed: EN61000-6-2, EN-61000-6-4, EN-61010-1
- Temperature range: 5...23...40 °C
- Fuel sawdust moisture meter WTR-2A is designed to measure moisture of sawdust, scobs, wood shavings, slivers and other finely crumbled wood waste used as fuel
- Range: 35...85 %
- Sample volume: 120 cm2
- Measuring sample: 0,2 MPa
- Gas measuring, monitoring and warning controller (Multi-Sensor-Controller MSC) for reliable detection of combustible, toxic and refrigerant gases
- Flexible control: 3 relays (SPDT, potential-free, 250 V)
- Intelligent Communication: RS-485 interface with DGC and Modbus protocol
- Precise signal transmission: 4–20 mA input and output for seamless system integration, up to 3 sensors including remote
- Stationary gas detection device PX for continuous monitoring of ambient air for use in potentially explosive atmospheres in zones 1 and 2
- Certified safety: ATEX, IECEx and SIL2 certified for worldwide use in hazardous areas
- Flexible communication: 4–20 mA, RS-485 interface, DGC and Modbus for versatile integration
- Extended operating range: Operation from -40 °C to +60 °C with alarm and fault signal relay
SKU: 5905309602212
- Efento Gateway automatically transfers gathered data from Efento BLE (Bluetooth Low Energy) sensors to Efento Cloud or any other IoT platform over 4G LTE
- Gateway stores 500,000 measurements in its buffer memory in case the connection to Efento Cloud is lost, it will send the measurements right after connection is restored
- If Gateway used without Efento cloud it can store sensors data in its memory
- In local mode you can check the current and historical measurements (table/chart) and export the data in a form of CSV report
- Gateway communicates with sensors wirelessly over BLE. The maximum distance between Gateway and sensor is 100 m in the open space and 20 – 30 m in the buildings
- One gateway supports up to 128 Efento sensors
- Gateway can be integrated with any cloud platform or software that supports HTTP protocol (REST API)
- Setup takes under 5 minutes and can be completed using a smartphone with a free mobile app
- SIM card slot for LTE Cat 1 connection
- Power supply: 5 V, 1 A (USB-C)
- Backup battery: LI-Po, 1900 mAh (up to 12 hours backup power)
- Operating temperature: 0…+40 °C
SKU: 5906660327066
- Efento Gateway automatically transfers gathered data from Efento BLE (Bluetooth Low Energy) sensors to Efento Cloud or any other IoT platform
- Gateway stores 500,000 measurements in its buffer memory in case the connection to Efento Cloud is lost, it will send the measurements right after connection is restored
- If Gateway used without Efento cloud it can store sensors data in its memory
- In local mode you can check the current and historical measurements (table/chart) and export the data in a form of CSV report
- Gateway communicates with sensors wirelessly over BLE. The maximum distance between Gateway and sensor is 100 m in the open space and 20 – 30 m in the buildings
- One gateway supports up to 128 Efento sensors
- Gateway can be integrated with any cloud platform or software that supports HTTP protocol (REST API)
- Configuration of Efento Gateway using any internet browser over LAN
- Ethernet connection for data transfer
- Power supply: 5 V, 1 A (mini USB)
- Operating temperature: 0…+40 °C
Inline sensors of the GLAST series primarily are used for the inspection of highly reflecting surfaces (e.g. stainless steel panels, aluminum sheets, painted surfaces, plastic films) and transparent objects (films, glass plates, plexiglass plates).
GLOSS sensors prioritize narrower detection range, thus making it faster than similar devices.
Gloss sensors RLS-GD-15, R-LAS-GD-15-HP. The sensors are designed for plastic plate and ceramic parts gloss degree measurement. Two measurements are done at the same time – direct reflection direction and diffusion reflection direction.
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- External probes can be connected
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±0,5 %
- Automatic temperature compensation
- Calibrated for more than 400 grain species
- 2” LCD screen
- USB connection for software updates and data transfer
- Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
- Portable, small dimension grain moisture meter
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±1 % (in range up to 10 %)
- Calibrated for more than a hundred grain types (the list can be extended)
- Automatic temperature compensation
- 2” LCD screen
- USB connection for software updates
- Supply: 2xAA (1,5 V, LR6)
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- Temperature measurement accuracy: ±0,5 °C
- Moisture measurement accuracy: ±0,5 %
- Calibrated for more than 400 grain types
- Automatic temperature compensation
- 2” LCD screen
- USB connection for software updates
- Supply: 1x6LF-22 (9 V)
- Portable, small dimension grain moisture meter
- The sample is ground, increasing the measurement accuracy
- Temperature measurement accuracy: ±1 °C
- Moisture measurement accuracy: ±0,5 %
- Automatic temperature compensation
- LCD screen
- Supply: 4xAA (1,5 V), 1xCR2032 (3 V)
- G-7 is designed for moisture measurement of grain
- Moisture measurement range: 9...30 %, depends on grain type
- Built-in calibrations for barley, coffee, corn, flax, hay, oats, pasta, rapeseed, rough rice, rye, sorghum, soybeans and wheat
- Built-in temperature correction over the range of 0...70 °C
- Programmable offset to match elevator
- Stores up to 150 accumulated readings in user-defined batches by grain
- Displays the average and highest readings, standard deviation, co-efficient of variance oh stored readings
- Built-in connector accepts any Delmhorst electrode
- Built-in calibration check
- Audible, adjustable alarm
- Size: 180 x 150 x 140 mm
- Weight: 1800 g
- Rugged construction ensures years of reliable use
- Supply: 9 V battery
- 1-year warranty
- Data converter which connects reader in safe zone with network switches and temperature cables/spears in dangerous zone
- Input: 4 x temperature cables (from switches GWNET11 and cables GWSL 1100 or GWSL 2100)
- Output: Modbus RTU, RS-485
- Reads data from 68 individual temperature cables and spears
- Supply: 230 VAC / 115 VAC
- Protection class: IP66
- Certificates: IECEx, ATEX
- Works as a multiplexer, enabling 4 additional temperature cables or spears to be connected to GWAB11 converter
- Another GWNET11 can be connected in parallel, further expanding inputs of GWAB11 by 4
- Operating temperature: -20...+50 °C
- Protection class: IP66
- Certificates: IECEx, ATEX
- Data logger (4 MB, up to 1 year of backup)
- Sample rate: 60 s...18 h
- Communication: GSM/3G/HSPA/Telstra arba GSM/2G/GPRS arba CDMA/Verizon
- Certificates: FCC, ETSI, C-TICK
- Option: GPS
- 1 input: for sensors with SDI-12 interface
- 2 input: double analog/digital/counter input or I2C interface
- USB connection: for charging and RanchMgr communication
- LCD screen
- Remote control
- Solar panel
- Supply: battery (typical run time without sunlight is 1 month)
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø9,8 mm
- Length: 1...35 m
- Tensile strength: ≤ 2,5 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
- Grain temperature monitoring system for steel and concrete bins
- Digital sensors with 2-wire bus
- Sensor spacing: 2 or 3 m
- Diameter: Ø17 mm
- Length: 1...100 m
- Tensile strength: ≤ 8 t
- Operating temperature -20...50 °C
- Maximal surface temperature 85 °C
- System is ATEX-, IECEx- and GOST-R approved
- ATEX approval code: Ex II 1D Ex ia IIIC T85°C
Automatic portable solid state particle (dust) meter EMIOTEST 3114 is designed for periodic solid state particle concentration measurement in closed channels, i.e. flue gas, and perform other functions:
- Periodic measurement of solid state particle concentration in stationary sources of emission
- Solid state particle concentration measurement in gasses
- Testing of dust removal equipment
- Gas flow rate measurement
- Calibration and periodic control of automatic systems (AMS) by measuring the emission and mass stream of dust
- Dioxins, furans, PAH, mercury concentration measurement
- Heavy meal, HCL, HF concentration measurement
- GA-1 is designed for grease detection in separators, basins and tanks
- Easy to install, does not need calibration
- Switch output
- Remote monitoring capability
- Wall-mounted
- Supply: 230 VAC, 50/60 Hz