Electrode level sensor AUREGIS LJ-E3 with 3 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-E5 with 5 electrodes for level measurement. Sensor with other connection thread and electrode length can be made according to request.
Electrode level sensor AUREGIS LJ-EB for liquids level measurement. By request sensor can be made with 2 to 5 electrodes with different lengths.
- Electrodes: Stainless steel DIN 1.4301 (AISI 304)
- Insulator: Teflon
- Electrode extension: Stainless steel DIN 1.4301 (AISI 304)
- Process connection: Stainless steel DIN 1.4301 (AISI 304)
- Connection head: Aluminum alloy
- Electrode length: Standard – 1000 mm or by request
- Process connection: R1 1/2“
- Process temperature: -30...+180 °C
Fluid level electrode probes SKC-201, designed to control conductive fluid level in open and pressure tanks. Electrodes – rod or flexible (rope with plastic coating). Probe head is made of acid-resistant steel. Maximal electrode count – 3. Insulation is made out of high quality plastic, enabling the probe to be used in food industry. Standard version probes are coated with plastic (FEP, PU, PVDF), lowering the residue collection (slime, carbonate, foam, etc.). Two modifications are available – with connection cable (P) and connector (G).
Fluid level electrode probes SKC-101, designed to control conductive fluid level in high temperature and high pressure medium. Modifications differ by permissible operating temperature. Recommended to use with Elcluwo 112...114 level alarms.
Utilizing unique dual-sensing technology, the device combines electromagnetic induction with an integrated ultrasonic sensor to provide highly accurate detection of both liquid level and flow velocity. Specifically optimized for partially filled pipes, open channels, and gravity-fed systems, the unit achieves an outstanding accuracy of ±1–2% of the actual flow rate.
- Internal pipe diameter: DN80…DN600
- Flow velocity (min. / max.): 0,46…7,5 m/s
- Accuracy: ± 1…2 % of actual flow (depends on flow profile and level detection)
- Process Temperature: 0…+70 °C
- Coating materials: hard rubber
- Maximum working pressure: No pressure (gravity flow) or 10 bar if pipe is full
- Output signal: 2× pulse / flow switch (max. 400 Hz), 4 ... 20 mA, 1× RS485 interface (Modbus / M-Bus protocol), M-Bus, HART, Ethernet module (TCP/IP, integrated web server)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Data archiving on a micro-SD card
- Process connections: flange
- Maximum ambient temperature: 55 °C
- Power supply: 24 V AC / DC, 230 V AC
- Protection class: IP68 for sensor, IP65-IP68 for transmitter
FLOW 55 datasheet [EN]
FLOW 38 MID version with certification, allowing the flow meter to be used for utility metering. FLOW 38 MID is certified for use with drinking water. The FLOW 38 MID electromagnetic flow rate meter is a precise measuring device designed to measure the flow of electrically conductive liquids. The electronic unit (display) can be connected directly to the body (rotatable up to 350° for convenient viewing). Various process connection versions are available. A wide selection of materials for the internal surfaces in contact with the process medium allows the device to be adapted to various liquids.
- Internal pipe diameter: DN10…DN400
- Flow velocity (min./max.): 0,1…12 m/s (R40, R50)
- Accuracy: 0.2% in the 1:100 range, 0.5% in the 1:200 range
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber, teflon, ceramic
- Maximum working pressure: up to 16 bar
- Output signal: pulse, 4-20 mA, RS485 (Modbus RTU/ M-bus)
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Process connections: Flange, Thread
- Maximum ambient temperature: 50 °C
- Power supply: 24 VAC/VDC, 110... 230 VAC
- Protection class: IP65, IP67, IP68
The FLOW 38 electromagnetic, bidirectional flow and flow rate meter is a precise measuring device designed to measure the flow of electrically conductive liquids. Due to the wide range of configurations available, this device is used in many industries. The electronic unit (display) can be connected directly to the body (rotatable up to 350° for convenient viewing) or connected via a cable up to 30 meters long. Various process connection versions are available. A wide selection of materials for the internal surfaces in contact with the process medium allows the device to be adapted to various liquids. FLOW 38 is certified for use with drinking water. There is also a version of the Flow38 with MID certification, allowing the flow meter to be used for utility metering.
- Internal pipe diameter: DN4-DN600
- Flow velocity - bidirectional (min./max.): 0.2…12 m/s
- Accuracy: 0.2% in the 1:100 range, 0.5% in the 1:200 range
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber, Rilsan, Teflon, ceramic
- Maximum working pressure: up to 100 bar
- Output signal: pulse, 4-20 mA, RS485 (Modbus RTU/ M-bus), Modbus TCP/ IP, HART
- An optional IoT module allows measured values to be transmitted wirelessly via NB-IoT to the cloud
- Process connections: Flange, Sandwich, Food grade fittings (clamp), Thread
- Maximum ambient temperature: 55 °C
- Power supply: 24 VAC/VDC, 110... 230 VAC
- Protection class: IP65, IP67, IP68
The FLOW45 electromagnetic flowmeter is equipped with a lithium battery, so it does not require an external power supply. The device has high accuracy in terms of full flow rate. Before each measurement, automatic diagnostics of all functions and parts necessary for proper measurement are performed. The device has a built-in empty pipe test and if there is no full flow, it will invalidate the entire measurement, as well as assess the flow direction and record the appropriate data.
- Internal pipe diameter: DN10…DN200
- Flow velocity (min. / max.), bidirectional: 0,2…12 m/s (1/60)
- Accuracy: 1 % for 1…10 m/s
- Maximum medium temperature depending on the inner coating: 150 ℃
- Coating materials: rubber (hard, soft, drinking water certified), Teflon, ceramic, Rilsan
- Maximum working pressure: up to 100 bar
- Output signal: pulse, RS485
- GSM data transmission module
- Data archiving on a micro SD card
- Process connections: flange, thread, sandwich, food grade
- Maximum ambient temperature: 5…55 °C
- Power supply: replaceable lithium battery (last up to 5 years) / external (12 V DC, max. 500 mA)
- Protection class: IP65, IP67, IP68
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached.
- Weight: 163 g; Buoy volume: 280 cm3: Maximum pressure:< 1 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
- Double water- and air-resistant sealant increases protection against infiltration even more
- Weight: 250 g; Buoy volume: 430 cm3; Maximum pressure: < 1 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Due to great reliability, sleek shape, heavy mass and filled interior, it is best suited for usage in wastewater
- Double water- and air-resistant sealant increases protection against infiltration even more
- Weight: 1050 g; Buoy volume: 990 cm3; Maximum pressure: < 2 bar
- Universal level regulators (level relays) are designed to be used for water and wastewater level control by turning off the water pump when desired level is reached
- Boasts for great reliability and small size
- Weight: 111 g; Buoy volume: 225 cm3; Maximum pressure: < 2 bar / < 5 bar
Absolute encoder AC58. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø58, axis - Ø10mm
Incremental encoder RI36. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø36.6 mm, axis - Ø4/6/8/10 mm
Incremental encoder RI38. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø39 mm, axis - Ø6 mm
Incremental encoder RI42. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø40 mm, axis - Ø6 mm
Incremental encoder RI76. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø76 mm, ašis - Ø15...42 mm
Incremental encoder RX70. Vibration- and overload-resistant. Wide range of appliance.
- Size Ø69mm, axis - Ø10mm
- Certified for ATEX zone
- Complies to category II 2 gas and dust
- IP65/IP66 protection class
- Certified: II 2 G/D E Ex d II T4/T6 IP65/IP66 135 °C bz. 85 °C
- Universal industrial rotary encoders
- Up to 40,000 steps
- High degree of signal accuracy
- Ingress protection up to IP67
- Fits most applications due to many flange and connection options
- Suitable for high shock loads
- Typical fields of application are machine tools, CNC axes, Packaging machines, Motors/ drives, Injection molding machines, Sawing machines
- Operating temperature up to 100°C (RI 58-T)
- Measurement of 85 power network parameters, including current and voltage harmonics up to 31st in 1-phase 2-wire or 3-phase 3 or 4-wire.
- Accuracy of active energy measurement 0.5S or 0.2S
- RS-485 (Modbus RTU) interface for remote monitoring of measured parameters
- The dual-tariff function for energy billing applications
- 2 relay outputs
- Pulse output: SO output as pulse or alarm
- 2 digital inputs as energy consumption, pulse counting and contact status
- Measured values displayed in 10 configurable screens
- Possibility programming of current and voltage ratio without restrictions as in MID-certified products
- Measurement inputs dedicated for x/1A and x/5A current transformers
- Power supply: 100…550 V a.c. / d.c.
- DIN rail mounted
- Analog inputs: 6 (0...10 VDC / 4...20 mA, configurable, isolated)
- Digital inputs: 4 (isolated)
- RS-485 input (up to 24 Modbus RTU registers)
- Memory: 70 000 values
- Ethernet connection
- Modbus RTU to Modbus TCP conversion
- Webserver
- Periodical upload of data logger file to a remote HTTP server
- HTTP Post, HTTP API
- SNMP alarms (up to 5 recipients)
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Ethernet connection
- Analog inputs: 2 (0...10 VDC)
- Digital inputs: 2
- Relay outputs: 2 (NO/NC)
- 1-Wire input (up to 8 sensors)
- Memory: 70 000 values
- Modbus TCP/IP support
- Webserver
- XML/JSON, HTTP API commands
- SNMP alarms (up to 5 recipients)
- E-mail alarms (up to 5 recipients)
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Ethernet connection
- Digital inputs: 1
- Relay outputs: 8 (NO/NC)
- Webserver
- XML and HTTP API commands
- E-mail alarms (up to 5 recipients), SMTP with TLS support
- SNMP alarms
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...14 VDC
- Ethernet connection
- Modbus TCP/IP
- Digital inputs: 4
- 1-Wire input (up to 8 sensors)
- Analog inputs: 4 (0...60 VDC)
- Relay outputs: 4 (NO/NC)
- Configurable inputs
- Webserver
- HTTP Post, HTTP API
- E-mail alarms (up to 5 recipients), SMT with TLS support
- Operating temperature: -20...55 °C
- Warranty: 3 years
- Supply: 10...28 VDC
- Stable long-life electrochemical gas sensor
- Range 0...10 / 0...200 / 0...1500 ppm C2H4
- Resolution 0,1 / 1 / 5 ppm C2H4
- Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life electrochemical gas sensor
- Range 0...10 / 0...200 / 0...1500 ppm C2H4
- Resolution 0,1 / 1 / 5 ppm C2H4
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- Electrochemical gas sensor
- Range: 0...10 / 0...200 / 0...1500 ppm C2H4
- Resolution: 0,1 / 1 / 1 ppm C2H4
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Electrochemical gas sensor
- Range: 0...20 / 0...100 ppm C2H4O
- Resolution: 0,1 / 1 / 5 ppm C2H4O
- Analog output: 2 x 4...20 mA / 0a...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST) / LCD indicator
- Option: remote sensor (default cable length is 3 m)
- Operating temperature: -20...+50 °C
- Supply: 11...30 VDC / 24 VAC or 90...265 VAC
- Air flow monitor with switching output for control cabinet installation
- Safely and reliably monitor hot air flows up to 400°C
- Sensitive response behaviour
- Large measuring range (0.1...30 m/s), simple and fast commissioning
- Areas of application: Monitoring of heating coils, drying plants, industrial ovens, granulate dryers, surface technology plants, thermoprocess technology
- Flow monitoring with SIL1 certification according to IEC 62061 (corresponds to Performance Level c according to EN ISO 13849-1)
- Can be used in ATEX zones 1 and 2 in conjunction with 2 Zener barriers supplied
- Large measuring range from 0.1 to 30 m/s with media temperatures from 0°C to 60°C
- With switching output suitable for control cabinet installation
- Developed for demanding industrial applications, IP40
- Example areas of application: Flow monitoring in paint shops, paper factories and research facilities
- Air flow monitor for monitoring air flow in ATEX zones 1 and 2 (optionally additionally with SIL1 or SIL2 certification)
- With switching output (1 NO/ 1 NC) for control cabinet installation
- Type tested by TÜV NORD according to DIN EN 61010-1: 2011-07
- Large measuring range (0.1...30 m / s), simple and fast commissioning
- Example areas of application: Monitoring heating registers, air curtain systems, dampers, fans, DDC, industrial furnaces, granulate dryers
- Exd fire-resistant RTD temperature sensors are designed for temperature sensing in explosive atmospheres
- Ranges: -200...+150°C; -200...+550°C; -200...+600°C
- Outputs: RTD, 4..20 mA
- Exd fire-resistant thermocouple temperature sensors are designed for temperature sensing in explosive atmospheres.
- Ranges: -40...+800°C; -40...+1200°C; -40...+700°C
- Outputs: TC, 4...20 mA
- Exi RTD sensors for explosive atmospheres with cable
- Range: -50 .. +400°C
- Cable insulation: PVC, silicone, teflon, glass fiber
- Exi thermocouple sensors for explosive atmospheres
- Range: -40...+1200°C
- Exi thermocouple sensors for explosive atmospheres with cable
- Range: -40...+400°C
- Exi thermocouple sensors for explosive atmospheres with connection head
- Outputs: TC, 4..20 mA
- Measurement distance: 0,5…2 m
- Accuracy: ± 0,5 °C
- Measurement speed: 0,7…2 m
- Software: DERMALOG Fever Detection (PC required)
- Interface: USB 3.0
- SDK: .Net / C / C++ / (Java coming soon)
- Measurement speed: 0,6 s (up to 700 people per hour)
- Integrated sensors: 5
- IR thermal array, range: 0...100 °C (± 0,3 °C)
- Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
- Relative humidity sensor, range: 0...100 % (± 3 %)
- Vibration sensor (for sabotage detection), range: 0,25...5 G
- Distance sensor, resolution: 1 mm
- Dew point calculation
- Relay inputs: 2
- Relay outputs: 2
- LED indication, buzzer (85 dB)
- Communication: Ethernet (10/100)
- Connector (RJ45) for connection of other Kentix devices
- Webserver
- Software: remote connection with AlarmManager-PRO
- E-mail, SNMP alarms, Rest API
- SD card slot (to save pictures, card up to 128 GB)
- PoE
- Optional: RFID reader
- Optional: wall bracket, cable
Multifunctional indoor climate sensor AERASGARD RFTM - LQ - PS - CO2 - Modbus with with LCD display.
- Temperature measuring range / deviation: 0…+50 °C / ± 0,2 °C at +25 °C
- Humidity measuring range / deviation: 0…100 % RH / ± 2 % RH (20…80 % RH), at 25 °C, otherwise ± 3 %
- CO2 Measuring range / accuracy: 0…5000 ppm / ± 30 ppm ± 3 % of measured value
- Particulate matter (PM) measuring range / accuracy: 0…50 μg/m³ 0…100 μg/m³ 0…300 μg/m³ 0…500 μg/m³
- Particulate matter (PM) accuracy ± 10 μg/m3 (± 10 % of measured value) at PM 2.5, ± 25 μg/m3 (± 25 % of measured value) at PM 10
- Air quality (VOC) measuring range: 0…100 %
- Data output: galvanically separated RS-485 Modbus RTU interface
- Variants: with / without LCD display
- One sensor covers about 30 m² of room area
- Power supply: 24 V ac/dc (200 mA)
- Standards: CE, EN 61 326, EMC Directive 2014/ 30/ EU, 2014/ 35/ EU
- Suitable for ATEX Zones 2 and 22
- Electrochemical gas sensor
- Range: 0...100, 0...300, 0...1000, 0...5000 ppm NH3
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life pellistor (catalytic bead) sensor
- Range: 0...15% vol. (0…100% LEL)
- Resolution: 0.1% vol. or 1% LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -10...+50 °C
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life photoacoustic or optical NDIR sensor
- Range: 0...10 000 ppm / 0...40 000 ppm / 0...5 % vol (0...100 % on request)
- Resolution: 1 ppm / 10 ppm / 0.01 % vol. CO2
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+60 °C; 0….100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...300 or 0...1000 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -20...+50 °C; 0….90 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detected gases: hydrogen, methane, acetylene, propane, butane
- Default calibration: methane CH4
- Stable long-life metal-oxide / pellistor sensor
- Range: 0...100% LEL
- Resolution: 0,1 / 1 % LEL
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+70 °C; ≤ 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Stable long-life electrochemical sensor
- Range: 0...10 / 0...200 / 0...1500 ppm
- Resolution: 0,1 / 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -40...+50 °C; up to 100 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC
- Suitable for ATEX Zones 2 and 22
- Detectable gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R-507, R-514a, R-1234ze and similar
- Stable long-life metal-oxide sensor
- Range: 0…1000 / 0…2500 ppm
- Resolution: 1 ppm
- Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
- Digital output: RS-485 (Modbus RTU protocol)
- Option: relay output (2 x SPST)
- Operating temperature: -30...+60 °C; < 95 % RH; 0,9…1,1 atm.
- Supply: 12...36 VDC (default), 24 VAC or 230 VAC