Linear encoder MLS110. With cable connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS110. With spiral connection.
Technical specifications
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS120.
Technical specifications
- Casing integrated into slider
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS130. Very small size.
Technical specifications
- Very small measuring head (in metal enclosure)
- Wide range of available resolution (up to 1 µm)
- Protection class IP67
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Linear encoder MLS210. With spiral connection and slider joints.
Technical specifications
- Protection class IP67
- Twin sliders
- Resistant to humidity
- Aluminum casing
- Incremental outputs A, /A, B, /B and Z
- Output “push-pull”, TTL or RS-422
- Supply 5 VDC or 10...30 VDC
Multifunctional professional current cramps NC14 with twistable clamp direction. The device is designed to measure AC current and AC/DC voltages, active, reactive, apparent power, inrush current, resistance, harmonics (up to 49th), phase angle, THD, power factor, DF, crest factor and power factor. Twistable clamp direction enables user to measure current in hard-reachable areas. Can be used in single- and three-phase (3 or 4 wire systems) networks. Two variants are available: NC14-400A (up to 400 A AC) and NC14-1000A (up to 1000 A AC).
- 4 analog inputs (standard signals, RTD, thermocouple)
- RS-485 Modbus output (Slave mode)
- 2 alarm outputs
- Galvanic isolation of inputs (2 from other 2)
- Programmable individual characteristics, mathematical functions
- Programmable time counters
- Rail-mounted
Data logger (recorder) AR207 is designed for temperature, standard DC voltage and current and pulse signal logging. 16/8 programmable channels. 4 programmable (NO or SSR) outputs for control and alarm. Color LCD TFT screen. Ethernet (web server function). Internal memory card which can be expanded using USB flash drive. Panel mounting. Multi-channel data presentation. Internal real time clock (RTC). Programming and data access protection.
- Fully functional data logger
- Two-line digital LCD display
- 4 control buttons
- 32 alarm LEDs
- Universal datalogger with 4 inputs, 2 for voltage, current, logic and pulse signals and 2 for connecting temperature and humidity probes.
- Measures carbon dioxide (CO2) using the integrated sensor.
- Multilogger can be installed permanently to Ethernet network or work as a portable device.
- Measured values can be viewed on a web browser, as well as stored and downloaded for later analysis.
- Calibration certificate included.
- 3 rechargeable AA batteries with a power adapter, wall holder and USB cable are included in the delivery.
- Temperature (Pt1000) and humidity probes are ordered separately. Cable length – 1, 2, 5, 10, 15 meters.
- Open collector transistor alarm output.
- To measure and data logging: carbon dioxide (0...5000 ppm), temperature (0...50 °C), atmospheric pressure (800...1100 hPa), humidity (0…100 % RH) in air and neutral gases
- Free software for configuration and data visualization
- Bluetooth communication for smartphones and tablets (Android and IOS)
- Safety lock magnetic mounting with inviolability system holder (accessories)
- Compatible with food industry environment
- Up to 4 recordable parameters simultaneously
- Optional calibration certificate
- PD51-A transducer/repeater, designed for conversion of RS232 interface to industrial RS485
- This enables to increase device number in the system and extend its range
- Long-life MOS or electrochemical gas sensor
- Range 0....1000 ppm NH3
- Resolution 1 ppm NH3
- Outputs 4...20 mA / 0...10 V, RS-485
- To measure carbon dioxide in air and neutral gases range 0…5000 ppm
- Configuration with switches or software: measuring ranges, outputs settings
- Optional with display or without display
- Ambient and duct models. Duct model available only without display
- To measure carbon dioxide and temperature in air and neutral gases ranges 0…5000 ppm, 0...50 °C
- Configuration with keypad or software: measuring ranges, units, outputs settings
- Optional with display or without display
- Galvanic isolation all the ways
- On request range increase up to 0...20 000 ppm
- For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
- Default calibration R-404a
- Long-life MOS sensor
- Range 0...1000 ppm
- Resolution 1 ppm
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Stable long-life metal-oxide gas sensor
- Range 0...100 % LEL (0...2,5 % vol.) C2H2
- Resolution 0,1 % LEL (25 ppm) C2H2
- Outputs 2 x 4...20 mA / 0...10 V, RS-485
- Attached or remote sensor
- The program is designed to represent and log measured values
- Representation tools: bar graphs, graphs, numbers
- Interfaces: RS-485 MODBUS RTU, ASCII, LUMBUS, MODBUS TCP/IP
- Number of MODBUS devices that can be represented (1 device – 1 address): 5, 10, 30 and 100 (selected while ordering)
- Data logging: tables and/or graphs in PC memory
- Meter to measurements electric quality parameters in 3 phase systems
- Programmable display pages
- 3 programmable alarm outputs and 1 pulse output
- Digital transmission to the master system through the RS-485 interface
- USB for configuration by using free eCon software
Fluid level alarm Elcluwo 111S, designed for usage with conductometric probes for fluid level alarm and control.
Technical specifications
- One or more level control
- Switch output 2A, 250 VAC
- Probe supply from isolated ~12 V source
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
Fluid level alarm Elcluwo 112S, designed for usage with conductometric probes for fluid level alarm and control, depth pump protection.
Technical specifications
- One or more level control
- Switch outputs: switching + NO 2 A / 250 VAC
- Probe supply from isolated ~12 V source
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
- One or more level control
- Switch outputs: switching + 3 x NO 2 A / 250 VAC
- Probes: galvanically isolated, max. 2mA, 5V~ 100 Hz
- Adjustable sensitivity
- Available modes – flooding, drainage, dry flow, overflooding
- Pump or valve control
- Designed for work with various probes: SKS 401, 201, 101, SW-01 and others
- Mounting on standard rail (35 mm)
- Supply: 230 VAC / 24 VAC
- One or two level control
- Switch outputs – switching + 5 x NO, 2A / 250 VAC
- Probes: galvanically isolated, max. 2uA, 5V~ 100 Hz
- Adjustable sensitivity
- Available modes – filling, draining, dry flow, overflow, two/three pump control and others
- Valve or gate control
- Adapted for work with various probes – SKS 401, 201, 101, SW-01 and others
- Mounted on standard rail (35 mm)
- Supply: 230 VAC / 24 VAC
- Measurement distance: 0,5…2 m
- Accuracy: ± 0,5 °C
- Measurement speed: 0,7…2 m
- Software: DERMALOG Fever Detection (PC required)
- Interface: USB 3.0
- SDK: .Net / C / C++ / (Java coming soon)
- Measurement speed: 0,6 s (up to 700 people per hour)
- Integrated sensors: 5
- IR thermal array, range: 0...100 °C (± 0,3 °C)
- Room temperature sensor, range: -40...+85 °C (± 0,5 °C)
- Relative humidity sensor, range: 0...100 % (± 3 %)
- Vibration sensor (for sabotage detection), range: 0,25...5 G
- Distance sensor, resolution: 1 mm
- Dew point calculation
- Relay inputs: 2
- Relay outputs: 2
- LED indication, buzzer (85 dB)
- Communication: Ethernet (10/100)
- Connector (RJ45) for connection of other Kentix devices
- Webserver
- Software: remote connection with AlarmManager-PRO
- E-mail, SNMP alarms, Rest API
- SD card slot (to save pictures, card up to 128 GB)
- PoE
- Optional: RFID reader
- Optional: wall bracket, cable
- The system is designed to monitor pressure and flow rate of medical gasses
- Information is gathered from pressure and flow rate transmitters and conveyed into the controllers which transfer the data into a PC via RS-485 interface (MODBUS protocol)
- SCADA software enables the visualization of the process
- Data is logged annd represented on the computer screen
- Values can also be represented in graphs
- The system is designed to contol ambient parameters (temprature, humidity,lighting time, CO2, O3 and O2 concentration)
- The data is gathered from various measuring devices and conveyed into a PLC
- PLC and SCADA interface is MODBUS TCP
- Manual and automatic control is available
- Marameters can be changed via SCADA (IGSS) software
- All data is logged
2-channel binary input converter SM3 with RS-485/232 interface. Modbus RTU and ASCII.
8 binary output converter SM4 with RS-485/232 interface. Modbus RTU and ASCII.
8-channel binary input converter SM5 with RS-485/232 interface. Modbus RTU and ASCII.
Counter ALC77-C for linear and rotary encoders (up/down).
Technical specifications
- 600 kHz input frequency
- Encoder input (A and B signals)
- 7-digit LED screen
- Range -999...9999
- 2 programmable set points (SPs)
- 2 switch outputs + RS-232
- Protection class IP65
- Supply 24 VAC/VDC or 230 VAC
- Sensor supply 5 VDC or 12 VDC
- Size 72 x 72 mm
Counter ALC77-T for linear and rotary encoders (for tachometers).
Technical specifications
- 5 kHz input frequency
- Encoder input (A and B signals)
- 7-digit LED screen
- Range -999...9999
- 2 programmable set points (SPs)
- 2 switch outputs
- Protection class IP65
- Supply 24 VAC/VDC or 230 VAC
- Sensor supply 5 VDC or 12 VDC
- Size 72 x 72 mm
Counter ALC77-B for linear and rotary encoders (batch).
Technical specifications
- 10 kHz input frequency
- Encoder input (A and B signals)
- 7-digit LED screen
- Range -999...9999
- 2 programmable set points (SPs)
- 2 switch outputs
- Protection class IP65
- Supply 24 VAC/VDC or 230 VAC
- Sensor supply 5 VDC or 12 VDC
- Size 72 x 72 mm
Counter ALC94UNI for linear and rotary encoders (up/down), universal.
Technical specifications
- 600 kHz input frequency
- Encoder input
- 6-digit LED screen
- Range -99999...999999
- 2 programmable set points (SPs)
- 2 switch outputs OR RS-232
- Protection class IP65
- Supply 24 VAC/VDC or 230 VAC
- Sensor supply 5 VDC or 12 VDC
- Size 96 x 48 mm
- Wide temperature range: -10...+1200 °C
- 320 x 240 and 640 x 480 infrared resolution
- 9 or 60 Hz models available
- Sighting: IR-Fusion technology (thermal and visible sighting) for easy alignment and added detail on blended images
- Remote motorized focus
- Multiple field interchangeable lens options available
- GigE Vision interface
- LAN/Ethernet with PoE for communication with the thermal imager provides access to Ethernet, Web server and ThermoView Software
- I/O alarming capabilities
- ThermoView software for industrial automation applications
- Ambient temperatures to 200 °C with high temperature enclosure
- Air purge and accessories available
- Rugged housing, IP67 rated
- Indoor temperature controller of TR series (S+S Regeltechnik, Germany)
- TR-040 (external setting): 0...40 °C
- TR-040U (internal setting): 0...40 °C
- TR-060 (external setting): 0...60 °C
- TR-060U (internal setting): 0...60 °C
- Output: Relay
- Switching capacity: 24...250 VAC (16 A)
- Ambient temperature: -35...65 °C
- Protection class: IP65
Ultrasonic level meter ULM-53 is designed for continuous liquid (even if polluted), mash and paste materials level measurements in closed and open tanks, sumps, open channels, etc. Adjustments are made with two buttons. State indication by two LEDs. Current (4...20 mA, 20...4 mA) or voltage (0...10 V, 10...0 V) outputs. Xi version is for usage in explosive areas.
ULM-70 is designed for continuous non-contact level measurements. Suitable for usage in various liquids and bulk-solid materials. OLED display. Fast measured values representation on display. Current (4...20 mA) output with HART protocol. Xi version for usage in explosive atmosphere.
- Modern, simple and user-friendly service
- Communication interfaces: RS-485 Modbus Slave, Modbus TCP Slave and optionally Ethernet
- FTP server (available in controller versions with Ethernet interface)
- Selection of PID parameters for any unit
- For easy programming and devices configuration, LUMEL offers one common LPCon software
- Parameter logging on SD card
- Universal measuring inputs, it can be used for controlling of temperature (RTD, thermocouple) and other physical values
- Colored TFT display presentation of measured values (numerical values, bar graph, meter, graph)
- Control algorithms On-Off; PID; 12 segmental adjustment program
- Interfaces: USB, RS485 (MODBUS-RTU) and Ethernet (100Base-T, TCP / IP protocols: Modbus-TCP, HTTP, SMTP)
- Internal webserver, information about the active channel, measuring parameters and the status of the regulation, requires access
- Available alarm sound and visual, status outputs and alarm notification e-mail
- Write data in a standard text file located in the internal controller memory (4GB) FAT with the possibility of editing in spreadsheets such as Microsoft Excel
- Selection of PID parameters for each output
- The possibility of creating inter-channel type mathematical and logical operations: the difference, average, sum, bigger, smaller measurement
- Function digital inputs (BIN) to changes modes associated outputs, retransmission of measurements
- Free software for data processing and device programming
- Controller is destined to control the temperature and other physical quantities like pressure, humidity, level
- Three optional outputs (0/4...20 mA ± 0,2 %, 0...10 V ± 0,2 %, 0/5 V, relay voltage output)
- Universal input for RTDs, thermocouples and analog signals
- Configuration parameters via keys or an optional RS-485 Modbus and free eCon software
- The controller has three alarms, which can be assigned to each output
- The output signals are galvanic isolated from the input signals and power supply
- Selection of PID parameters for any unit, or auto-tuning
- Protection class from frontal side: IP30, from terminal side: IP20
These jacket heaters enable the comfortable and effective way to heat up IBC containers and other tanks. Low energy losses, even heat distribution. Can be used for various products: water, oils, diesel fuel, resin, Vaseline, wax, lanolin, fats, butters, Ghee, glue and adhesive. Can be used with insulation lid.
- 1, 2, or 3 thermostats adjustable from 0…+90 °C
- Teflon coated Polyester Material
- Standard size IBC 1000L (4400 x 1000 mm)
- Durable, lightweight design with quick release buckles
- 3 m connection cable
- Protection class IP40 (Optional IP54)
- Warm-up duration approx. 48h (1000L drum with water starting from +15º C to +50º C with 2x1000 W heaters and isolation lid)
- Warm-up duration approx. 48h (1000L drum with water starting from +15º C to +70º C with 3x1000 W heaters and isolation lid)
Fluid level electrode probes SKC-101, designed to control conductive fluid level in high temperature and high pressure medium. Modifications differ by permissible operating temperature. Recommended to use with Elcluwo 112...114 level alarms.