This website uses cookies in order to provide better service. By using this website further you accept with this policy.

Поиск

Критерии поиска

Товары, соответствующие критериям поиска

Показать:
Сортировка:
  • Electrochemical gas sensor
  • Range: 0...250 ppm NO
  • Resolution: 1 ppm NO
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 3 / 6 ppm NO2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 / 0...200 ppm NO2
  • Resolution 0,02 / 0,1 ppm NO2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Electrochemical gas sensor
  • Range:
  • -- 0...20 ppm NO2
  • -- 0...200 ppm NO2
  • Resolution:
  • -- 0,1 ppm NO2 for 20 ppm range
  • -- 1 ppm NO2 for 200 ppm range
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -20...+50 °C
  • Supply: 11...30 VDC / 24 VAC or 90...265 VAC

Infrared temperature meter KIRAY 100 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Infrared temperature meter KIRAY 200 with double measuring laser. Main tool for temperature measurement in remote and dangerous areas.

Noncontact infrared thermometer KIRAY 300 is designed to diagnose, inspect and check the surface temperature of measured objects. Up to 100 values can be stored in the internal memory.

  • Noncontact infrared temperature meter 3i Plus (pyrometer), designed for metalworking industry where casting, hardening, heating take place. Also suitable for ceramics, semiconductor, chemical furnace temperature measurement
  • It is a new generation, small size IR device for high temperature measurement
  • Precise high-resolution optics guarantee high accuracy, resistant casing let the device survive falls from up to 1 meter height
  • That said, measurements can be done in various environments and from various distances
  • Noncontact stationary infrared temperature meter CM for temperature measurement
  • Range: -20...500 °C
  • Outputs: 0...5V, or TC K / J type (chosen while ordering)
  • Software “DataTemp Multidrop” for remote monitoring and configuration
  • Noncontact infrared thermal meter (pyrometer) ENDURANCE
  • for temperature measurement up to 3200 ºC with the resolution of 0,1 ºC
  • Outputs: Ethernet, profinet, 0/4...20mA (isolated), RS485, relay 48V and 300mA
  • Web server
  • Wider area can be measured when used with SpotScan
  • Noncontact infrared thermal meter Marathon MM, wide range of accessories for various applications
  • Range: -40...3000°C (in fixed ranges)
  • Outputs: 0/4...20mA, RS485, mechanical switch
  • Noncontact infrared thermal meter Thermalert TX, additional accessories for various applications
  • Can be used in an explosive area
  • Range: -18...2000 °C (in fixed ranges)
  • Outputs: 4...20mA, HART į RS232, mechanical switch (depends on version)
ORP electrode sensors (glass, epoxy body and submersible) Hовый

ORP electrode sensors (glass, epoxy body and submersible)

The CH52-E four-camera multisensor features four independent sensors, providing expansive coverage from a single install point. Each sensor includes a 1 / 2.8” progressive CMOS image sensor, varifocal lens with 2.08x optical zoom, and 30 meters of IR range to provide clear and consistent image quality in any lighting condition. The CH52-E includes four onboard CV25S Ambarella processors to support advanced analytics like AI-powered search, Occupancy Trends, line crossing, loitering, and Person of Interest (POI) alerts. The CH52-E excels at covering hallway intersections and exterior corners of buildings, providing comprehensive visibility and eliminating blind spots while only requiring a single PoE++ cable.

  • 30 - 365 days (1TB - 8TB) of onboard storage
  • Redundant cloud backup and unlimited cloud-based archiving of footage
  • Sensor Resolution: 4 x 5MP (2688 x 1944)
  • Protection class / Impact rating: IP66 / IK10
  • Operating temperature: -40…+50 °C
  • Warranty: 10 Years
  • Certifications: FCC, ICES, CE, UKCA, RCM, VCCI, KCC, NOM, CB, NTRA, ICASA, UL/cUL/IEC 62368-1, FY2019 NDAA compliant
  • Stable long-life electrochemical gas sensor
  • Range 0...20 % vol O2
  • Resolution 0,01 % vol O2
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • Default alarm set-points 19,5 / 18 % vol O2
  • Stable long-life electrochemical gas sensor
  • Range 0...20 % vol O2
  • Resolution 0,01 % vol O2
  • Outputs 2 x 4...20 mA / 0...10 V, RS-485
  • Attached or remote sensor options
  • Electrochemical gas sensor
  • Range: 0...25 % O2
  • Resolution: 0,01 % O2
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+50 °C
  • Supply: 12...36 VDC, 24 VAC or 230 VAC
  • Grain temperature monitoring system software for PC
  • Collects data from temperature cables GWSL 1100 and GWSL 2100 and spear temperature sensors GWTL-R
  • Stores, visualizes data in charts
  • Alarms
  • Level indication
pH / ORP microprocessor transmitter, 4-20 mA - RS485 – Modbus, PH 3436 Hовый

The instrument uses a pH/ORP sensor and RTD Pt100 temperature sensors. If the Pt100 is connected the transmitter makes automatic temperature compensation (pH only).

  • pH range: 0 ÷ 14.00 pH
  • ORP range: 0 ÷ 1000 / 0 ÷ -1000 / -1000 ÷1000 / 0 ÷ 2000 / 0 ÷ -2000 mV
  • Temperature range: -10.0 ÷ 110.0 °C / 14.0 ÷ 230.0 °F
  • Resolution: 0.01 pH, 1 mV, 0.1 °C
  • Digital output: RS-485 isolated
  • Analog output: 4-20 mA galvanically isolated, "current loop" two wires
  • Power supply: 9 / 36 Vdc
  • Dimensions: 71x95x58 mm. Rail Din (4 modules)
  • Operating temperature: 0…+50 °
  • EMC/RFI conformity: EN 61326
pH electrode sensors (glass, epoxy body and submersible) Hовый

pH electrode sensors (glass, epoxy body and submersible)

Phase voltage controller PKF-302. The device is designed for electric motor protection from asymmetric supply and grid voltage drop. The controller has two switch outputs of which one is used for protective shutdown and another for alarm. Simplified type 333 variant.

  • Channels: Shutdown and alarm
  • Supply: 3x (50...230...265)V. Max 2,5W
  • Frequency: 40...50...60 Hz
  • Indicator: 3 x LED 3 digits
  • Measuring mode: True RMS
  • Activation voltage: 185 V
  • Reset voltage: 195 V
  • Activation time: about 1s
  • Reset time: 1...999 s (optional 4 or 6 s)
  • Switch outputs: 2 x switching 2A, 250V AC
  • Ambient temperature: -15°C...55°C
  • Mounting: 35 mm rail
  • Protection class: panel IP40; connections IP20

Phase voltage controller PKF-333SZE. The device is designed for electric motor protection from asymmetric supply and grid voltage drop or overvoltage and automatic UPS activation. The controller monitors voltage phase angles and harmonic distortions due to generated high harmonics.

Phase voltage controller PKF-333SZR. The device is designed for electric motor protection from asymmetric supply and grid voltage drop or overvoltage and automatic UPS activation. The controller monitors voltage phase angles and harmonic distortions due to generated high harmonics.

  • PID control function with accurate self-tuning
  • Input: Pt100 (-200…+600 °C ± 0,5 % of full scale ± 1 digit)
  • Relay output: 250 V AC (5, 8, 16 A) NO / NC
  • Control algorithm: On-Off / P, PI, PD, PID (configurable)
  • Soft start feature
  • Selectable heating / cooling control
  • In case of sensor failure, periodically, auto-periodically running or relay state can be selected
  • Mountable on DIN rail
  • Power supply: 230 V AC, 10…30 V DC - 8…24 V AC (selectable on order)
  • Operating temperature: 0…+50 °C
  • Oxygen concentration measuring in air and inert gas mixtures
  • Specially developed for use in composting plants
  • Measuring range of oxygen concentration: 0,1…25 % (0…100 % range on request)
  • Value indicator of measured oxygen concentration
  • Output: 4…20 mA analog or bidirectional digital signal (for calibration, operation diagnostic)
  • Length and diameter of the sensor protection tube to the handle: 1200 x 30 mm
  • Length of the protective tube part to be stuck in the compost heap: ~ 1000 mm
  • Material of protective tube: Stainless steel 1.4301
  • Housing ambient temperature: -10…+50 °C
  • Probe ambient temperature: -10…+100 °C
  • Protection class of housing electronic: IP65
  • Protection class of probe: IP40
  • Rechargeable battery with indication of voltage
  • It is possible to connect the sensor to a stationary data processing system
  • Power factor controller for reactive power compensation
  • Measures 73 power network parameters (40 visible on screen, all via Modbus RTU)
  • Relay outputs: 4 / 6 / 8
  • Programmable switch in time, switch off time and discharge time
  • Alarm message and relay output
  • Optional digital output: Modbus RTU (RS-485)
  • Optional real time clock (RTC)
  • LCD screen
  • Operating temperature: -10...+60 °C
  • Protection class (front): IP54
  • Measuring range: -1…100 bar (see datasheet)
  • Basic accuracy 0,5% of range
  • Output: 4…20 mA
  • Process connection: G 1/2“, G 1/2“, G 1/2“ Flush membrane, G 1/4“, G 1/4“, 1/2“ NPT, 1/4“ NPT, Tri-Clamp (Ø 50,5) Flush membrane
  • Operating temperature: -20…+85 / 200 °C (see datasheet)
  • Stainless steel housing and diaphragm material
  • Protection class: IP67 / IP68

The small sensor dimension combined with IO-Link, the pressure and temperature value of the media make the NAI 8273 the ideal choice in various applications.

  • Measuring range: -0.2...0.2 to 0...700 bar
  • Output signal: IO-Link 1.1, COM3, min. process cycle time 1 ms, Smart Sensor Profile ED2, 2 Switching outputs PNP / NPN
  • Accuracy at 25°C typically: ± 0.3 % FS typ., ± 0.5 % FS typ.
  • Measuring principle: Thin-film-on-steel
  • Media temperature –40... +125 °C
  • Ambient temperature: –40...+125 °C
  • Protection class: IP65, IP67
  • Applications: Hydraulics, Machine tools, Process technology
  • Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
  • Webserver
  • Functional Block programming software
  • LED signaling for Link/Act Ethernet, serial RX-TX, power supply
  • Configurable by the software DEV9K
  • Galvanic isolation on all the ways (1500 VAC)

 

  • Interface: Ethernet (Modbus TCP), RS485 (Modbus RTU Master / Slave), RS232 (Slave)
  • Webserver
  • Functional Block programming software
  • LED signaling for Link/Act Ethernet, serial RX-TX, power supply, digital inputs and digital outputs state
  • Configurable by the software DEV9K
  • Capable to connect the sensors to the analog inputs
  • Galvanic isolation on all the ways (1500 VAC)
  • Supports devices: NAT 8252, NAH 8254, NAR 8258, ECL 8439
  • Fast and easy operation via Android app “Sensor Master Communicator SMC”
  • Read out of sensor data
  • Parametrization of switich points on NAx pressure switches
  • Measuring range adjustment on submersible pressure transmitter ECL
  • Reset pressure measurement instruments to factory settings
  • Ambient temperature: 0...40 °C
  • Supply: 5 V (USB)
  • Communication: Bluetooth Low Energy
  • 2 analog outputs (operating simultaneously):
    1. Current 4...20 mA or 0...20 mA (active output, cannot be supplied in two-wire current loop);
    2. Voltage 0...10 V.
  • Soft start/stop (ramping) or a triangular wave generator triggered manually or automatically after switching power on
  • 7-segment LED display with adjustable brightness
  • Optional RS485/RS232 serial interface (galvanically isolated, MODBUS-RTU communication protocol)
  • Password protection
  • High accuracy and immunity to interference
  • Supply: 230 VAC or 24 VAC/VDC
  • Panel housing 96 x 48 x 79 mm
  • Protection: IP65 (front) / IP20 (back)
  • Thermosetting cabinet with double doors. The cabinet dimension: 600 x 500 mm (max 2x 5,5 kW) or 800 x 600 (max 2x 7,5 kW; ... max 2x 22 kW).
  • Plinth or foundation for fixing the cabinet.
  • PLC controller with a display that changes the backlight depending on operating mode.
  • Program saved in the controller and on the SD card, enabling transferring the program to another controller in the event of a failure.
  • Router equipped with a 2G / 3G / 4G / LTE modem, 1 LAN 10 / 100 Mb/s port and radio module in the 802.11 b/g/n standard, supporting MIMO 2x2.

Reactive power controller RMB-10S. The device is designed for reactive power compensation battery control. Version with 6 switch outputs is available.

  • For R-12, R-123, R-125, R134a, R143, R-22, R404a, R-407c, R-410a, etc.
  • Default calibration R-404a
  • Range 0...1000 ppm
  • Resolution 1 ppm
  • Outputs 2 switches, 2 x 4...20 mA / 0...10 V, RS-485
  • MOS gas sensor
  • Detected gases: R-12, R-123, R-125, R-134a, R-143, R-22, R-404a, R-407c, R-410a, R1234yf, etc.
  • Standard calibration: R-404a
  • Range: 0...1000 ppm HFC
  • Resolution: 1 ppm HFC
  • Analog output: 2 x 4...20 mA / 0...10 V (user-settable)
  • Digital output: RS-485 (Modbus RTU protocol)
  • Option: relay output (2 x SPST) / LCD indicator
  • Option: remote sensor (default cable length is 3 m)
  • Operating temperature: -30...+60 °C
  • Supply: 11..30 VDC / 24 VAC arba 90...265 VAC
  • Ethernet connection
  • Digital inputs: 2
  • 1-Wire input (up to 2 sensors)
  • Analog inputs: 2 (0...60 VDC)
  • Relay outputs: 2 (NO/NC)
  • Webserver
  • HTTP and XML API commands
  • E-mail alarms, SMTP, SNMP
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC
  • TC Monitor is remote monitoring software that collects data and controls your TCG (GSM) and TCW (Ethernet) Teracom I/O modules
  • User-friendly WEB interface for easy configuration and control
  • Free version let monitor up to 10 items
  • The monitored parameters can be sensors, digital and analog inputs and relay outputs
  • Graphical and Data dashboards for better visualization
  • TC Monitor allows flexible administration of user accounts
  • Easy access to the raw data tables, export in .csv format
  • Alarm notifications
  • User activities log
  • Ethernet connection
  • Digital inputs: 2
  • Relay outputs: 2 (NO/NC)
  • Webserver
  • Operating temperature: -20...55 °C
  • Warranty: 3 years
  • Supply: 10...14 VDC

The PD9W is an industrial RS-232 / RS-485 to WiFi and Ethernet converter.

  • Communication interfaces: 1x RS485, 1 x RS232, 1x Ethernet and WiFi (802.11b/g/n)
  • Modes: AP, STA, AP + STA, AP + LAN, AP + WAN, Route and Bridge
  • Work modes: transparent transmission mode, serial port command mode, HTTP Client mode, Modbus TCP<=>Modbus RTU mode and AT command mode
  • Configuration the parameters via the WEB server
  • RS232 port for RTS/CTS signals
  • Hardware Watchdog, Heartbeat
  • Electrostatic protection 15 / 8 kV
  • Power supply: 5…36 V dc

PD9-Modbus RS485 to Ethernet converter can realize bidirectional transparent transmission between RS485 and Ethernet. It carries ARM processor, low power, fast speed, high stability. Via web-page or software, Rs-485 to Ethernet Converter can realize serial data and TCP/IP data package transparent transmission.

  • Communication interfaces: 1x RS485, 1x Ethernet WAN/LAN
  • Easy configuration the parameters via the webpage or set-up software
  • Compact size, DIN rail mount
  • Working mode: TCP server, TCP client, UDP server, UDP client
  • Modbus RTU to TCP conversion, Modbus Polling
  • DHCP support, IP dynamic or static
  • Watchdog function
  • Working temperature: -40…85°C
  • Power supply: 5…36 V dc
  • Digital input: 4 ch. pulse
  • Independent modes: OPEN / CLOSED (“Dry contact”) and COUNTER (S0 standard)
  • Output: RS-485 MODBUS RTU interface
  • Non-volatile memory for counters storage and settings
  • Galvanically isolated inputs
  • DIN rail mounting
  • Protection class: IP40 (connections IP20)
  • Operating temperature range: -20…+60 °C
  • Power supply: 5…28 VDC
  • Modern SCADA system
  • Free license allows to work with up to 50 objects (each having 10 variables / tags / atoms)
  • Free license supports only one chosen driver (i.e. Modbus)
  • Hardware-independent, communicates with all major industry-standard
  • Mobile application (in full version)
  • 25 year experience in the marketplace  - developed by 7-Technologies which belongs to Schneider Electric
Fluid level electrode ASTA 460 MM4.  Electrode length 460 mm Electrode material Stainless steel (AISI 304) Thread M4  More information on electrode extension ASTA 460 MM4 on Lovato website [EN] ..
SF6 gas concentration meter SF6-Air Sensor for indoor air control. The device measures small SF6 gas concentration and shows actual values. SF6-Air sensor does not use radioactive materials, so no special safety measures must be taken. Ambient humidity and other gasses do not affect the measurements. No calibration needed in all device lifespan. Reliable measurement. Alarm levels can be set according to demand. Technical specifications Sensor:  NDIR, 2 Measuring range: 0 ... 1000 ppm ..

Single-use data logger for real-time measurement of temperature, humidity and light. GSM tracking and LTE 4G connectivity for smart logistics worldwide. Free usability of tempmate.®-Cloud for information viewing, reports generation and devices setup. Tempmate-GS2 have 3 models: T, TH and TE, for more information see datasheet.

  • Temperature measurement range*: -200…+100 °C
  • Relative humidity measurement range*: 0…100 %
  • Ambient light measurement range*: 0…10000 lx
  • Local storage capacity*: 24200 values for Temperature, Humidity and Light
  • Shelf-Life:
    • Lithium Battery devices: 12 months (possibility to charge)
    • Non-Lithium Battery devices: 6 months (possibility to charge)
  • External sensor*: PT100 (cable length: 1m, length of probe is 6cm length, 4 mm in diameter, sensor tip: stainless steel)
  • Log interval: User defined: 1 min. to 60 min. (10 min. as standard setting preconfigured)
  • Transmission Interval: User defined: 10 min. to 1440 min. (60 min. as standard setting preconfigured)
  • Recording Duration:
    • Lithium Battery: 90 days (with standard log interval of 10 min. and transmission interval of 240 min.)
    • Non Lithium Battery: 60 days (with standard log interval of 10 min. and transmission interval of 240 min.)
  • Certifications: CE, EN12830, EMC, RoHS, FCC
  • Connectivity: LTE 4G cat 1 with 2G Fallback
  • Report Generation: Readable in the Cloud and locally in the device through the USB 2.0 interface
  • Location: LBS - GSM Localization
  • Recommended Storage Temperature: -15…+25 °C
  • Software to work with Comet devices Sxxxx, Rxxxx, UxxxxM, Dxxxx and Mxxxx
  • Device settings
  • Data download
  • Analysis of critical situations
  • Presentation of measured data
  • Reports
  • Database import/export
  • Free license
Solid particle (dust) concentration meter Dust Trak DRX. Models 8533, 8834.DUSTTRAK DRX monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK DRX monitors measure aerosol contaminants such as dust, smoke, fumes and mists. ..
The new DUSTTRAK II Aerosol Monitors are battery-operated, data-logging, light-scattering laser photometers that give you real-time aerosol mass readings. They use a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance. Suitable for clean office settings as well as harsh industrial workplaces, construction and environmental sites and other outdoor applications. DUSTTRAK II monitors measure aerosol contaminants such as dust, smoke, fumes and mists.          &n..
  • Flexible spears for grain temperature measurement
  • Rigid construction
  • Diameter: Ø8 mm
  • Penetration depth: up to 12 m
  • Digital temperature sensor
  • Measurements are done using PC software or handheld reader GW-200
  • Temperature spears and cables can be integrated into single system
Loading...